• 제목/요약/키워드: Mortar block

검색결과 64건 처리시간 0.023초

폴리머 모르터를 이용한 사면보호재의 개발 (Development of Polymer Mortar Defensive Block for Erosion Control Works)

  • 유능환;연규석;김기성;지경용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.107-112
    • /
    • 1998
  • The objective of this study was to develop a polymer mortar defensive block with high strength and durability using unsaturated polyester resin to complement defects of conventional cement mortar defensive block. Physical and mechanical properties of the polymer mortar defensive block were also investigated. Low absorptivity, high impact strength, and great bending strength of the polymer mortar defensive block was compared with those of the conventional cement defensive block. In conclusion, the polymer mortar defensive block is excellent and useful as industrial products for erosion control works.

  • PDF

폴리머 복합재료를 이용한 유도 블럭의 개발 (Development of Polymer Mortar Guide Block for the Blind Handicapped People)

  • 이기원;연규석;이윤수;지경용
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1999년도 Proceedings of the 1999 Annual Conference The Korean Society of Agricutural Engineers
    • /
    • pp.330-335
    • /
    • 1999
  • The objective of this stu요 was to develop a polymer mortar guide block for the blind handicapped people. A high strength and a long durability polymer concrete using unsaturated polyester resin was used to developed the block and to improve the exiting cement mortar guide bloc. Physical and mechanical properties of the polymer mortar guide block were investigated with respect to absorptivity, impact strength, bending strength compared to those of the conventional cement guide block. The polymer mortar guide block was proven to have properties , indication that the block have better industrial applications.

  • PDF

접지전극을 고려한 모형블록의 저항률 분석 (Resistivity Analysis of Model Block for Grounding Electrodes)

  • 고희석;김성삼;최종규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.437-439
    • /
    • 2007
  • This paper was analyzed the resistivity change characteristic of mortar model block and concrete that was made earth electrode that's used concrete or basic concrete of building for 1 year. The early resistivity measurement value of concrete model block is higher than mortar model block. But after 1 year the resistivity measurement value of mortar model block is significantly higher than concrete model block. Because depends on time elapsed complete dryness factor of mortar model block that has not gravel is higher than concrete model block. And absorptance and function of mortar mode block was by far outstanding than concrete model block in the data for verification of the amount of contained water and the amount of dryness of mortar model block and concrete model block.

  • PDF

폴리머 모르터를 이용한 사면보호재의 개발 (Development of Polymer Mortar Protection Block for Erosion Control Works)

  • 유능환;연규석;김기성;이윤수
    • 한국농공학회지
    • /
    • 제40권5호
    • /
    • pp.52-58
    • /
    • 1998
  • The objective of this study was to develop a polymer mortar protection block with high strength and durability using unsaturated polyester resin to complement defects of conventional cement mortar protection block. Physical and mechanical properties of the polymer mortar protection block were also investigated. Low absorptivity, high impact strength, and great bending strength of the polymer mortar protection block was compared with those of the conventional cement protection block. In conclusion, the polymer mortar protection block is excellent and useful as industrial products for erosion control works.

  • PDF

굴 패각 분말을 골재로 사용한 인터로킹 블록에 관한 연구 (A Study on the Interlocking Block Using Oyster Shell Powder as Aggregate)

  • 신종현;김해나;홍상훈;정의인;김봉주
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.25-26
    • /
    • 2020
  • During the molding process of the existing interlocking block, the pigment is firstly laid, and cement is poured on the pigment secondly to give vibration. Interlocking blocks made of conventional cement are entirely dark where the pigment area is removed. On the other hand, when looking at the mortar with oyster shells added, the color is closer to that of the existing cement mortar. Therefore, if an interlocking block is produced by adding a pigment to a mortar with an oyster shell added, it is considered that the amount of pigment is less than that of the existing interlocking block. This study is a basic study of interlocking blocks. To investigate the strength characteristics of mortar using oyster shell powder as aggregate, W/C is 25%, 50%, oyster shell replacement rate is 0%, 25%, 50%, 75%, 100% was substituted to make a mortar and its strength change was studied.

  • PDF

Compressive strength behaviour of low-strength hollow concrete block masonry prisms

  • Syiemiong, Hopeful;Marthong, Comingstarful
    • Structural Engineering and Mechanics
    • /
    • 제80권6호
    • /
    • pp.689-699
    • /
    • 2021
  • The present study aims to understand the behaviour of low-strength masonry prisms constructed with locally-produced low-strength hollow concrete blocks. Compression tests were conducted on masonry prisms constructed with three different mortar grades of cement-sand ratios of 1:3, 1:4.5 and 1:6 representing strong, moderately strong and weak mortar. Stress-strain curves were generated from the test results for the masonry prisms. The hollow concrete masonry units employed in this study are some of the weakest as compared to other masonry units employed by other researchers. The compressive strengths for masonry prisms with mortar grades 1:3, 1:4.5 and 1:6 are 2.21 MPa, 2.19 MPa and 2.25 MPa respectively. The results indicate that the masonry compressive strength of such low-strength hollow concrete block masonry prisms is not influenced by the mortar strength. Simple relationships to estimate the modulus of elasticity and compressive strength of masonry prisms is also proposed.

건축물기초 접지극의 비교 분석에 관한 연구 (Research for a comparison an analysis of grounding electrode in the Foundation of building)

  • 김성삼;김주찬;이충식;고희석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.271-273
    • /
    • 2005
  • In this paper, The experiment is performed for using reinforced building of foundation as a down conductor and a substitutional earth electrode. It is shown that earth resistance is influenced by mortar block resistance and concrete resistance more than the change of the resistance which is about steel reinforcing volume in all of the mortar block model and concrete block model.

  • PDF

STUDY OF NEW CAST-IN-PLACE MORTAR WALL FOR HOUSE CONSTRUCTION COMPARED TO BRICK AND MORTAR-BLOCK SYSTEM (A SIMULATION IN DIFFERENT AREAS)

  • Arief Setiawan Budi Nugroho;Shin-ei Takano
    • 국제학술발표논문집
    • /
    • The 3th International Conference on Construction Engineering and Project Management
    • /
    • pp.196-202
    • /
    • 2009
  • Study from Yogyakarta earthquake reconstruction program, cast-in-place wall using fix-size formwork system (Old-CIP) has offered a good alternative for house construction. A simulation has also confirmed that this system using mortar as the main material can provide cheapest cost and lowest total man power compared to conventional wall construction technique: brick or mortar-block wall. This paper presents the new wall construction technique: full size cast-in-place wall (New-CIP). The detail of how this new technique implemented is described. In addition, considering that material and labor cost in one area is different to others, cost analysis for different resources prices and wages of three cities are taken into a simulation. The analysis is aimed to distinguish the implementation feasibility of New-CIP system compared to the four common wall systems. Finally, its implementation resistance is also discussed.

  • PDF

Compression Behavior of Form Block Walls Corresponding to the Strength of Block and Grout Concrete

  • Seo, S.Y.;Jeon, S.M.;Kim, K.T.;Kuroki, M.;Kikuchi, K.
    • International Journal of Concrete Structures and Materials
    • /
    • 제9권1호
    • /
    • pp.21-33
    • /
    • 2015
  • This study aimed to present a reinforced concrete block system that reduces the flange thickness of the existing form block used in new buildings and optimizes the web form, and can thus capable of being used in the seismic retrofit of new and existing buildings. By conducting a compression test and finite element analysis based on the block and grouted concrete strength, it attempted to determine the compression capacity of the form block that can be used in new construction and seismic retrofit. As a result, the comparison of the strength equation from Architectural Institute of Japan to the prism compression test showed that the mortar coefficient of 0.55 was suitable instead of 0.75 recommended in the equation. The stress-strain relation of the block was proposed as a bi-linear model based on the compression test result of the single form block. Using the proposed model, finite element analysis was conducted on the prism specimens, and it was shown that the proposed model predicted the compression behavior of the form block appropriately.

폐CNT와 전도촉진재를 혼입한 시멘트 모르타르 블록의 발열 전도 특성 (Heating Transferring Charcteristics of Cement Mortar Block with Waste CNT and Conduction Activator)

  • 구현철;김운학;오홍섭
    • 한국건설순환자원학회논문집
    • /
    • 제10권2호
    • /
    • pp.176-183
    • /
    • 2022
  • 저전력 사용이 가능한 발열콘크리트를 제작하기 위하여 시멘트 모르타르에 고순도 폐CNT를 혼입하였으며, 모르타르의 전도율을 향상시키기 위하여 압축강도를 제어하는 수준에서 탄소섬유와 폐음극재를 활용하고자 하였다. 사용된 폐CNT는 다중벽 CNT의 함유량이 많은 것으로 분석되었고, 모르타르 배합시 분산성을 높이기 위하여 액상형으로 치환하여 사용하였다. 모르타르 발열시 태양광 등에 의한 소형 자가발전 설비를 활용하고 전자파를 최소화하기 위하여 DC 24 V이하의 전력 사용시의 모르타르의 온도 변화를 평가하였다. 액상형 폐CNT를 적용하고, DC 24 V의 전압을 도입한 경우 200 × 100 × 50 mm 블럭 시험편에서 60 ℃까지 상승하였으며, 액상형 폐CNT와 탄소섬유, 폐음극재를 모두 사용한 경우에는 DC 12 V에서도 55 ℃이상까지 온도가 상승하여 현장 적용성이 충분한 것으로 판단되었다. 특히 발열에너지 변화량에 있어서도 다른 변수들과 비교하여 효과적인 것으로 나타났다.