• 제목/요약/키워드: Monolithic column

검색결과 37건 처리시간 0.023초

Experimental Cyclic Behavior of Precast Hybrid Beam-Column Connections with Welded Components

  • Girgin, Sadik Can;Misir, Ibrahim Serkan;Kahraman, Serap
    • International Journal of Concrete Structures and Materials
    • /
    • 제11권2호
    • /
    • pp.229-245
    • /
    • 2017
  • Post-earthquake observations revealed that seismic performance of beam-column connections in precast concrete structures affect the overall response extensively. Seismic design of precast reinforced concrete structures requires improved beam-column connections to transfer reversed load effects between structural elements. In Turkey, hybrid beam-column connections with welded components have been applied extensively in precast concrete industry for decades. Beam bottom longitudinal rebars are welded to beam end plates while top longitudinal rebars are placed to designated gaps in joint panels before casting of topping concrete in this type of connections. The paper presents the major findings of an experimental test programme including one monolithic and five precast hybrid half scale specimens representing interior beam-column connections of a moment frame of high ductility level. The required welding area between beam bottom longitudinal rebars and beam-end plates were calculated based on welding coefficients considered as a test parameter. It is observed that the maximum strain developed in the beam bottom flexural reinforcement plays an important role in the overall behavior of the connections. Two additional specimens which include unbonded lengths on the longitudinal rebars to reduce that strain demands were also tested. Strength, stiffness and energy dissipation characteristics of test specimens were investigated with respect to test variables. Seismic performances of test specimens were evaluated by obtaining damage indices.

반복하중을 받는 하이브리드 프리캐스트 보-기둥 접합부의 성능평가 (Structural Capacity Evaluation of Hybrid Precast Concrete Beam-Column Connections Subjected to Cyclic Loading)

  • 최현기;유창희;최윤철;최창식
    • 콘크리트학회논문집
    • /
    • 제22권3호
    • /
    • pp.325-333
    • /
    • 2010
  • 이 연구에서는 시공성과 경제성이 향상되고 중진 지역에서 사용할 수 있는 새로운 프리캐스트 콘크리트 보-기둥 접합부 상세를 복합구조로 개발하고 실험을 통하여 이를 검증하였다. 이 상세는 기둥 속에 매립된 각형강관과 보U형 단부를 갖는 보 단부에 매립된 플레이트를 볼트로 결합시킬 수 있는 구조로 되어있다. 하이브리드 스틸-콘크리트 접합합부에 앞서 콘크리트가 조기에 파괴되는 것을 막기 위하여 접합부 부분에 ECC(engineered cementitious composite)를 사용하였다. 개발된 접합부 상세에 대한 성능을 검증하기 위하여 보-기둥 접합부 실험체를 계획하여 이에 대한 내진성능 실험을 실시하였다. 내부 접합부에 있어서는 접합부 횡보강근 유무와 현장타성 범위를 변수로 3개의 실험체를 제작하였다. 실험은 기둥에 일정 축력을 가한 상태에서 PC기둥 단부에 액츄에이터를 설치하여 변위제어로써 반복가력 하여 실시하였다. 실험에서 얻은 자료를 접합부 내력, 강성, 에너지 소산능력 등에 대하여 분석하였으며, 그 결과 이 연구에서 제시한 새로운 보-기둥 접합부 상세는 강재와 콘크리트 그리고 ECC 사이에서의 다른 부착 특성 때문에 구조거동에서 차이점이 관찰되었으며, 기준 실험체를 제외한 두 실험체의 경우 ECC 및 철골연결재에 의해 소성힌지를 유도할 수 있는 것으로 나타났다. 그리고 프리캐스트 접합부는 높은 일체성과 모멘트 저항 능력을 보이며 중진 지역에서 사용가능함을 보였다.

프리캐스트 콘크리트 보-기둥 접합부의 이력거동 및 내진성능 (Hysteretic Behavior and Seismic Resistant Capacity of Precast Concrete Beam-to-Column Connections)

  • 최현기;최윤철;최창식
    • 한국지진공학회논문집
    • /
    • 제14권4호
    • /
    • pp.61-71
    • /
    • 2010
  • 프리캐스트 콘크리트 골조에서 실물크기의 보-기둥 접합부 실험체 5개를 대상으로 반복가력 실험을 수행하였다. 지진하중을 받는 골조를 대상으로 1개의 일체식 실험체와 4개의 프리캐스트 실험체를 포함하여 5개의 1/2스케일의 내부 보-기둥 접합부를 대상으로 하였다.주요 변수는 보의 구조적 연속성을 확보하기 위한 접합부의 형태와 접합부의 특별한 보강형태(섬유콘크리트와 횡보강근)로 하였다. 실험체는 강기둥-약보 개념에 따라 설계하였다. 보 철근은 접합부에 큰 비탄성 전단력이 작용할 경우 보에 소성힌지가 발생하도록 계획하였다. 접합부의 성능평가는 접합부의 강도, 강성, 에너지 소산능력과 층간변위비로 평가하였다. 실험결과 실험체의 파괴는 보의 소성힌지부에서 파괴되었다. 보-기둥 접합부의 성능은 대체적으로 우수한 것으로 나타났다. 접합부의 강도는 일체식 RC 구조의 비해 1.15배 정도 향상되었다. 층간변위 3.5%때의 강도에서 실험체는 ECC의 인장변형능력과 철골연결재의 항복에 의해 연성거동 하였다.

An experimental study on different socket base connections under cyclic loading

  • Pul, Selim;Husem, Metin;Arslan, Mehmet Emin;Hamzacebi, Sertac
    • Computers and Concrete
    • /
    • 제13권3호
    • /
    • pp.377-387
    • /
    • 2014
  • This paper presents an experimental study on socket base connections of precast reinforced concrete columns. The main purpose of this study is to determine socket base connection which has the closest behavior to monolithic casted column-base joints. For this purpose, six specimens having different column-socket base connection details were tested under cyclic loading. For each test, strength, stiffness, ductility and drift ratios of the specimens were determined. Test results indicated that a suggested connection type is 10%-30% stronger than the other type of connections under lateral loading. The welded connection (PC-5) had better lateral load carrying capacity and ductility. On the other hand, performance of standard connection (PC-1) which is commonly used in construction was weaker than other connections. Thus, decision of connection type should be referred not only performance but also applicability.

2400MPa 긴장재가 적용된 포스트텐션 프리캐스트 콘크리트 보-기둥 접합부의 반복가력실험 (Reversed Cyclic Loading Test of Post-Tensioned Precast Concrete Beam-Column Connections with 2400MPa Prestressing Strands)

  • 황진하;최승호;이득행;김강수;우운택
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.45-52
    • /
    • 2017
  • The precast concrete (PC) method has many advantages in fast construction, quality control, etc. In domestic construction market, however, its application has been quite limited because of the concerns about structural integrity and seismic performances due to the discrete connections between precast concrete members. By applying the post-tensioning method, the precast beam-column connection can be well tightened, allowing improved structural integrity, and proper seismic performances can be also achieved. In this study, reversed cyclic tests have been conducted on the beam-column connection specimens, where the test variables included the compressive strength of grouting mortar and the tensile strengths of prestressing strands, based on which their seismic performances have been examined in detail. The post-tensioned PC beam-column connections showed good seismic performances comparable to that of the monolithic reinforced concrete connection specimen. When 2400 MPa prestressing strands are applied to the beam-column connection, it is preferable to adjust the prestress level similar to that applied for the 1860 MPa prestressing strands to avoid premature local crushing failures at the beam-column connections.

반복 횡하중을 받는 유공 PC 기둥 접합부의 구조성능 평가 (Evaluation of Structural Performance the Hollow PC Column Joint Subjected to Cyclic Lateral Load)

  • 서수연;윤승조;이우진
    • 콘크리트학회논문집
    • /
    • 제20권3호
    • /
    • pp.335-343
    • /
    • 2008
  • 본 연구는 프리캐스트 콘크리트 모멘트 골조 시스템의 시공 성능 향상과 접합부 내진성능 향상을 위하여 새로운 개념의 PC 기둥 부재와 시공 공정을 개발하였다. 이 PC 기둥은 원심력으로 제조되어 내부에 공간이 비워있는 중공관 PC 부재로서, 이 기둥을 활용할 경우, 중공관을 통하여 현장타설 콘크리트와 동일한 일체성을 확보할 수 있다. 본 연구는 제안된 PC 기둥 접합부의 내진성능을 평가하기 위하여 반복가력 시험을 수행하였다. 실험체는 기둥 주철근의 연속성을 확보하기 위하여 기계적 이음과 겹침이음을 활용한 2가지 이음 방법을 적용하였으며, PC 기둥의 띠철근 배근 형태를 고려하여 실물 크기의 4개 실험체를 계획 실험하였다. 반복 횡력 시험 결과, 제안된 HPCC 기둥을 활용할 경우, 현장타설 RC 시스템의 접합부 내진성능을 충분히 확보할 수 있는 것으로 나타났다.

Analysis-oriented model for seismic assessment of RC jacket retrofitted columns

  • Shayanfar, Javad;Omidalizadeh, Meysam;Nematzadeh, Mahdi
    • Steel and Composite Structures
    • /
    • 제37권3호
    • /
    • pp.371-390
    • /
    • 2020
  • One of the most common strategies for retrofitting as-built reinforced concrete (RC) columns is to enlarge the existing section through the application of a new concrete layer reinforced by both steel transverse and longitudinal reinforcements. The present study was dedicated to developing a comprehensive model to predict the seismic behavior of as-built RC jacketed columns. For this purpose, a new sectional model was developed to perform moment-curvature analysis coupled by the plastic hinge method. In this analysis-oriented model, new methodologies were suggested to address the impacts of axial, flexural and shear mechanisms, variable confining pressure, eccentric loading, longitudinal bar buckling, and varying axial load. To consider the effective interaction between core and jacket, the monolithic factor approach was adopted to extent the response of the monolithic columns to that of a respective RC jacket strengthened column. Next, parametric studies were implemented to examine the effectiveness of the main parameters of the RC jacket strategy in retrofitting as-built RC columns. Ultimately, the reliability of the developed analytical model was validated against a series of experimental results of as-built and retrofitted RC columns.

Rapid HPLC Method for the Simultaneous Determination of Eight Urinary Metabolites of Toluene, Xylene and Styrene

  • Lee, Cheol-Woo;Lee, Jeong-Mi;Lee, Jae-Hyun;Eom, Han-Young;Kim, Min-Kyung;Suh, Joon-Hyuk;Yeom, Hye-Sun;Kim, Un-Yong;Youm, Jeong-Rok;Han, Sang-Beom
    • Bulletin of the Korean Chemical Society
    • /
    • 제30권9호
    • /
    • pp.2021-2026
    • /
    • 2009
  • Toluene, xylene and styrene are volatile organic solvents that are commonly used in mixtures in many industries. Because these solvents are metabolized and then excreted in urine, their urinary metabolites are thought to be biomarkers of occupational exposure to these solvents. Therefore, a simple, rapid, and yet reliable analytical method for determining the metabolites is required for accurate biological monitoring. In the present study, a simple and rapid HPLC-UV method was developed for the simultaneous determination of eight major metabolites of toluene, xylene and styrene: hippuric acid (HA), mandelic acid (MA), o-, m- and p-methylhippuric acids (o-, m- and p-MHAs), and o-, m- and p-cresols. A monolithic column was employed as the stationary phase and several conditions, including flow rate, composition of mobile phase and column temperature, were variables for the optimization of the chromatographic resolution. All eight metabolites were successfully resolved within 5 minutes in 10% aqueous ethanol containing 0.3% acetic acid and 1.6% $\beta$-cyclodextrin, using a flow rate gradient of 1.0 - 5.0 mL/min at 25 ${^{\circ}C}$. The performance of this method was validated by linearity, intra- and inter-day accuracy, and precision. The linearity was observed with correlation coefficients of 0.9998 for HA, 0.9999 for MA, 0.9989 for o-MHA, 0.9998 for m-MHA, 0.9991 for p-MHA, 0.9997 for o-cresol, 0.9998 for m-cresol, and 0.9986 for p-cresol. The intra- and inter-day precision of the method were less than 5.89% (CV) and the accuracy ranged from 92.95 to 106.62%. The validity was further confirmed by analysis of reference samples that were prepared by the inter-laboratory quality assurance program of the Korea Occupational Safety and Health Agency (KOSHA, Seoul, Korea). All measured concentrations of the analytes agreed with the certified values.

특수모멘트골조 상세를 갖는 건식 프리캐스트 콘크리트 보-기둥 접합부의 내진성능평가 (Seismic Performance Evaluation of Dry Precast Concrete Beam-Column Connections with Special Moment Frame Details)

  • 김선훈;이득행;김용겸;이상원;여운용;박정은
    • 한국지진공학회논문집
    • /
    • 제27권5호
    • /
    • pp.203-211
    • /
    • 2023
  • For fast-built and safe precast concrete (PC) construction, the dry mechanical splicing method is a critical technique that enables a self-sustaining system (SSS) during construction with no temporary support and minimizes onsite jobs. However, due to limited experimental evidence, traditional wet splicing methods are still dominantly adopted in the domestic precast industry. For PC beam-column connections, the current design code requires achieving emulative connection performances and corresponding structural integrity to be comparable with typical reinforced concrete (RC) systems with monolithic connections. To this end, this study conducted the standard material tests on mechanical splices to check their satisfactory performance as the Type 2 mechanical splice specified in the ACI 318 code. Two PC beam-column connection specimens with dry mechanical splices and an RC control specimen as the special moment frame were subsequently fabricated and tested under lateral reversed cyclic loadings. Test results showed that the seismic performances of all the PC specimens were fully comparable to the RC specimen in terms of strength, stiffness, energy dissipation, drift capacity, and failure mode, and their hysteresis responses showed a mitigated pinching effect compared to the control RC specimen. The seismic performances of the PC and RC specimens were evaluated quantitatively based on the ACI 374 report, and it appeared that all the test specimens fully satisfied the seismic performance criteria as a code-compliant special moment frame system.

Capillary Electrochromatography with Liquid Crystal Crown Ether Modified Hybrid Silica Monolith for Analysis of Imidacloprid and Carbendazim in Tomatoes

  • Wang, Mingming;Feng, Rui;Shen, Jing;Chen, Hao;Zeng, Zhaorui
    • Bulletin of the Korean Chemical Society
    • /
    • 제33권7호
    • /
    • pp.2224-2228
    • /
    • 2012
  • This study describes the ability of capillary electrochromatography (CEC) for the determination of imidacloprid and carbendazim in tomato samples. A novel liquid crystal crown ether modified hybrid silica monolithic column was synthesized, characterized and developed as separation column for the first time. Baseline separation of imidacloprid and carbendazim could be achieved using a mobile phase containing 90% (v/v) 20 mmol/L phosphate buffer (pH 7.0) and 10% (v/v) acetonitrile. The matrix matched calibration curves were linear with correlation coefficient $r^2$ > 0.9998 in the range of 0.20-10.00 mg/L. The limits of detection for imidacloprid and carbendazim were 0.061 and 0.15 mg/kg, respectively, which were below the maximum residue limits established by the European Union as well as Codex Alimentarius. Average recoveries for imidacloprid and carbendazim varied from 101.6-108.0% with relative standard deviations lower than 6.3%. This method was applied to the analysis of tomatoes collected from local markets.