• Title/Summary/Keyword: Monocusp reconstruction

Search Result 12, Processing Time 0.019 seconds

Surgical Results of Monocusp Implantation with Transannular Patch Angioplasty in Tetralogy of Fallot Repair

  • Jang, Woo Sung;Cho, Joon Yong;Lee, Jong Uk;Lee, Youngok
    • Journal of Chest Surgery
    • /
    • v.49 no.5
    • /
    • pp.344-349
    • /
    • 2016
  • Background: Monocusp reconstruction with a transannular patch (TAP) results in early improvement because it relieves residual volume hypertension during the immediate postoperative period. However, few reports have assessed the long-term surgical outcomes of this procedure. The purpose of the present study was to evaluate the mid-term surgical outcomes of tetralogy of Fallot (TOF) repair using monocusp reconstruction with a TAP. Methods: Between March 2000 and March 2009, 36 patients with a TOF received a TAP. A TAP with monocusp reconstruction (group I) was used in 25 patients and a TAP without monocusp reconstruction (group II) was used in 11 patients. We evaluated hemodynamic parameters using echocardiography during the follow-up period in both groups. Results: At the most recent follow-up echocardiography (mean follow-up, 8.2 years), the mean pulmonary valve velocities of the patients in group I and group II were $2.1{\pm}1.0m/sec$ and $0.9{\pm}0.9m/sec$, respectively (p=0.001). Although the incidence of grade 3-4 pulmonary regurgitation (PR) was not significantly different between the two groups (group I: 16 patients, 64.0%; group II: 7 patients, 70.0%; p=0.735) during the follow-up period, the interval between the treatment and the incidence of PR aggravation was longer in group I than in group II (group I: $6.5{\pm}3.4years$; group II: $3.8{\pm}2.2years$; p=0.037). Conclusion: Monocusp reconstruction with a TAP prolonged the interval between the initial treatment and grade 3-4 PR aggravation. Patients who received a TAP with monocusp reconstruction to repair TOF were not to progress to pulmonary stenosis during the follow-up period as those who received a TAP without monocusp reconstruction.

Total correction of TOF using monocusp bearing outflow patch (단일판첨을 내재한 우심실유출로 Patch 를 이용한 활로 4 징증의 교정수)

  • 박이태
    • Journal of Chest Surgery
    • /
    • v.17 no.4
    • /
    • pp.636-643
    • /
    • 1984
  • For the purpose of avoiding postoperative massive pulmonary insufficiency after transannular outflow tract reconstruction in patients with tetralogy of Fallot, we have used monocusp bearing outflow patch since June 1983. Right heart catheterization and pulmonary arteriography were performed in 7 patients among the total 11 patients corrected with monocusp bearing outflow patch during postoperative 14th day to 22nd day. Particular attention was paid to the evaluation of the pulmonary valve competence, and the results were; 1.One patient died of acute renal failure secondary to low cardiac output and the operative mortality was 9.1%. 2.The average PRV/FA ratio was 0.491 and the average systolic pressure gradient between right ventricle and pulmonary artery was 17.7mmHg. The average Qp/Qs was 1.13. 3.Inspite of using monocusp bearing outflow patch, the hemodynamic and pulmonary arteriographic results were unsatisfactory in respect to pulmonary valve competence.

  • PDF

Early and mid-term results of pulmonary valve reconstruction in surgical repair of tetralogy of Fallot; comparison with other techniques of right ventricular outflow reconstruction (활로사징 완전교정술에서 폐동맥 판막 재건술의 조기 및 중기 결과; 우심실 유출로 재건 방법에 따른 비교)

  • Wang, Sheng Wen;Lee, Young Seok;Kim, Si Ho;Kim, Tae Hong;Ban, Ji Eun;Lee, Hyoung Doo;Chang, Yun Hee;Sung, Si Chan
    • Clinical and Experimental Pediatrics
    • /
    • v.49 no.6
    • /
    • pp.635-642
    • /
    • 2006
  • Purpose : The purpose of this study is to determine whether the new pulmonary valve reconstruction technique prevents short-term postoperative pulmonary regurgitation and improves early and mid-term clinical outcome. Methods : We reviewed postoperative echocardiographic variables and chest X-ray films from 31 patients who had undergone valve reconstruction(pulmonary valve reconstruction group : PVR) for the repair of TOF between April 2000 and August 2004. We compared the clinical data of these patients with those from 47 patients who had right ventricular outflow tract reconstruction with a monocusp valve(monocusp ventricular outflow patch group : MVOP) and 22 patients who had a transannular patch repair without a monocusp valve(transannular patch group : TAP). Results : In the PVR group, 25 patients(81 percent) had trivial or mild pulmonary regurgitation in their early post operative echocardiogram. Only 12 patients(26 percent) in the MVOP group had mild pulmonary regurgitation; and no patient in the TAP group had it. Pulmonary valve function was good in 96 percent of the PVR group, 36 percent of the MVOP group, and none in the TAP group in early post-operative echocardiogram. Follow-up echocardiogram(1, 2, 3, 4 years later) of the MVOP and TAP groups showed moderate pulmonary regurgitation and severely decreased valve function in almost all cases. However, in the PVR group 54 percent(16/28), 50 percent(14/28), 37 percent(9/24), and 31 percent(5/16) of the patients had trivial or mild pulmonary regurgitation 1, 2, 3 and 4 years after operation, respectively. The valve function remained good in 80 percent(24/30), 64 percent(18/28), 57 percent(12/21), and 31 percent(5/16) of the patients 1, 2, 3 and 4 years after operation respectively. Conclusion : Pulmonary valve reconstruction is effective in reducing pulmonary regurgitation and right ventricular dilatation in the repair of TOF, even though regurgitation increases with time. Further study is needed to determine long-term results.

Investigation of Bovine Pericardial Heterograft (II0) : Clinical applications of glutaraldehyde-preserved bovine pericardium (우심낭을 이용한 이종이식 보철편의 개발 (II) - 0.625% Glutaraldehyde 에 보존한 우심낭의 임상 적용 -)

  • 김기봉
    • Journal of Chest Surgery
    • /
    • v.23 no.3
    • /
    • pp.465-473
    • /
    • 1990
  • Glutaraldehyde have been used as the most effective cross-linking agent for stabilizing collagen fibers and preventing biodegradation. We processed bovine pericardium in a solution containing 0.625% glutaraldehyde,0.05M HEPES buffer and 0.26% magnesium chloride in saline. The glutaraldehyde-preserved bovine pericardium was implanted in 36 patients at Seoul National University Hospital during a 11-month period between May 1989 and March 1990. 24 were males and 12 females, with ages ranging from 6 months to 168 months [mean age of 43 months]. In 12 patients, the glutaraldehyde-preserved bovine pericardium was used for orthotopic reconstruction of the pericardial sac. In 24 patients. the glutaraldehyde-preserved bovine pericardium was heterotopically implanted.; pulmonary monocusp implant and RVQT [right ventricular outflow tract] patch widening were performed in 10 patients, pulmonary monocusp implant in 6, RVOT patch widening in 4, valved conduit in 2, conduit and pulmonary angioplasty in 1, and ventricular septation in l. With vascular suture techniques, the anastomoses were immediately tight. There was no bleeding from the needle holes and no oozing through bovine pericardium itself. During the follow-up period of up to 10 months, no infections of the glutaraldehyde-preserved bovine pericardium occurred and no bovine pericardium-related complications were observed in this series.

  • PDF

Aortic Valve Replacement with Pulmonary Autograft in Patient with Congenital Aortic Stenosis : Ross Procedure without Homograft -one case report - (선천성 대동맥판 협착증에서 폐동맥판 자가이식편을 이용한 대동맥판 교체술:동종판막을 쓰지 않는 Ross술식)

  • 이은상;윤태진;서동만
    • Journal of Chest Surgery
    • /
    • v.32 no.3
    • /
    • pp.303-306
    • /
    • 1999
  • This is a genuine case report of the Ross operation without the use of homografts or heterografts in reconstruction of the right ventricular outflow tract. A 8-year-old boy with congenital aortic stenosis underwent aortic valve replacement with a pulmonary autograft and right ventricular outflow tract reconstruction with a pericardial conduit bearing autologous aortic monocusp. The postoperative echocardiography and cardiac angiography revealed good ventricular function and competent neoaortic valve. He has been followed up for 19 months.

  • PDF

Surgical Repair of Type II Truncus Arteriosus Without a Extra-cardiac Conduct -A Case Report- (제2형 동맥간의 심장외 도관을 사용하지 않는 완전교정술 -1례 보고-)

  • 조은희
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.619-622
    • /
    • 1995
  • We report a successful surgical correction of type II truncus arteriosus without using a extra-cardiac conduit in an 2 month-old infant. The truncal root is transected, and the confluence of branch pulmonary arteries is brought anterior to the aorta by using Lecompte`s maneuver. The aorta is then reconstructed directly with an end-to-end anastomosis. The right ventricular outflow tract is reconstructed by anastomosing the posterior wall of the confluence directly to the upper part of the vertical right ventriculotomy. A monocusp ventricular outflow patch is then placed anteriorly to complete reconstruction of the right ventricular outflow tract. The patient had an uncomplicated postoperative course and was discharged on the 9th postoperative day.

  • PDF

Surgical Treatment of Complete Atrioventricular Septal Defect with Tetralogy of Fallot - one case - (활로씨 4징증을 동반한 완전방실중격결손의 수술치험;1례 보고)

  • Kim, Keun;Chang, Bong-Hyun;Lee, Jong-Tae;Kim, Kyu-Tae
    • Journal of Chest Surgery
    • /
    • v.25 no.8
    • /
    • pp.832-836
    • /
    • 1992
  • A 25-month-old patient with complete atrioventricular septal defect and Tetralogy of Fallot underwent repair of both anomalies. The diagnosis was established preoperatively by 2D-echocardiography, cardiac catheterization and cardioangiogram, Repair was accomplished using cardiopulmonary bypass and profound hypothermia to 18C, Closing of the atrioventricular septal defect was achieved with the use of two Dacron patchs by an atrial approach alone. Infundibulectomy and outflow tract reconstruction with the transannular pericadial patch containing a monocusp were performed. Upon the postoperative evaluation by 2D-echocardiography, mitral regurgitation was absent, but a tiny dehiscence of ventricular patch and minimal tricuspid regurgitation were noticed.

  • PDF

Pulmonary Autograft with Right Ventricular Outflow Tract Reconstruction in Swine model -1, Feasibility of REV operation- (돼지를 이용한 대동맥 판막에서 자가 폐동맥 판막 이식 및 우심실 유출로 형성술의 신술식 개발 -제1보 REV술식의 적합성 연구-)

  • 안재호;노윤우
    • Journal of Chest Surgery
    • /
    • v.29 no.8
    • /
    • pp.822-827
    • /
    • 1996
  • Ross procedure is an ideal operative modality for diseased aortic valve especially in children, but homogrart for right ventricular outflow tract(RVOT) reconstruction is not easily available in Korea. We tried to perform REV procedure for RVOT reconstruction in 10 young piglets(15.3 $\pm$ 1.3 kg) In an attempt to e clude the use of homograft in Ross operation. 3 of them survived after operation and raised till adult pig(about 70 kg), then examined their pulmonary arteries and hearts. Without any stenotic residues in the great arteries, we only found the deformed monocusp patch with severe calcification, which deprived the adequate valve function, but kept the pig growing normally We are sure that this operative modality (REV + Ross procedure) could be extendedly applied to the diseased human aortic valve, but we need to develope the anti-calcification method for the heterograft patch.

  • PDF

A Review of the Total Correction of Tetralogy of Fallot (Fallot 사징증에 대한 근치수술)

  • 최세영
    • Journal of Chest Surgery
    • /
    • v.18 no.2
    • /
    • pp.258-264
    • /
    • 1985
  • The experience with operative treatment for total correction of Fallot at the department of Thoracic and Cardiovascular Surgery, Keimyung University Dong San Medical Center from July 1980 to July 1984 was reviewed. There were 37 males and 12 females and their ages ranged from 3 years to 30 years, with the average age of 12.2 years. Sixty nine point four percent of patients were younger than 15 years of age. The most frequent type of right ventricular outflow stenosis was the combined type [pulmonary valvular and infundibular stenosis] containing 41 patients [83.7%] and there were 9 deaths in this group. The major associated lesions included Patent foramen ovale in 20 patients [40.8%], Atrial septal defect in 7 patients [14.3%], Left superior vena cava in 4 patients [8.2%], Right sided aortic arch in 2 patients [4.1%] and Patent ductus arteriosus in 11 patient [2.0%]. The pulmonary valvotomy was performed in 41 patients and patch graft reconstruction of the right ventricular outflow tract was performed in 23 patients. In 11 patients the monocusp patches were used. Thirty-five patients [71.4%] had the right bundle branch block postoperatively. There were 11 postoperative deaths with hospital mortality rate of 22.4% and the leading causes of death were low output syndrome, bleeding, and cerebral embolism.

  • PDF

Surgical treatment of pulmonary atresia -2 cases- (폐동맥 폐쇄증 (Pulmonary atresia)의 외과적 치료 -2예 보고-)

  • 강경훈
    • Journal of Chest Surgery
    • /
    • v.19 no.3
    • /
    • pp.464-469
    • /
    • 1986
  • Pulmonary atresia with intact ventricular septum, and with VSD were uncommon congenital anomalies with high mortality in the neonatal period. Those survivals depend on an adequate interatrial communication or interventricular communication and pulmonary flow via large aortopulmonary collateral including PDA. Recently we experienced surgical correction of 2 cases pulmonary atresia with intact ventricular septum and with VSD. On case 1, 10-years old male patient was confirmed as pulmonary valvular membranous atresia with intact ventricular septum combined with large functioning PFO and mild tricuspid incompetence. So we performed total correction under the E.C.C, that was PDA ligation, RVOT reconstruction with monocusp valved outflow patch [16mm], repair of tricuspid insufficiency and closure of PFO. Post-operative hemodynamic result was good and there was no event during hospital course. On case 2, 16-years old female patient was diagnosed as pulmonary atresia with VSD and PDA. MPA was absent, remained fibrous cord like remnant and type of VSD was subaortic defect [3cm by 3cm in the size]. PDA was located at the usual site. Under the E.C.C. VSD patch closure through the right ventriculotomy, anastomosis between the right ventricular outflow tract and the pulmonary bifurcated site with the extra-cardiac Hancock valved conduit [22cm] and PDA ligation were performed.

  • PDF