• 제목/요약/키워드: Monochromator

검색결과 85건 처리시간 0.03초

Nondestructive Prediction of Fatty Acid Composition in Sesame Seeds by Near Infrared Reflectance Spectroscopy

  • Kim, Kwan-Su;Park, Si-Hyung;Choung, Myoung-Gun;Kim, Sun-Lim
    • 한국작물학회지
    • /
    • 제51권spc1호
    • /
    • pp.304-309
    • /
    • 2006
  • Near infrared reflectance spectroscopy (NIRS) was used to develop a rapid and nondestructive method for the determination of fatty acid composition in sesame (Sesamum indicum L.) seed oil. A total of ninety-three samples of intact seeds were scanned in the reflectance mode of a scanning monochromator, and reference values for fatty acid composition were measured by gas-liquid chromatography. Calibration equations were developed using modified partial least square regression with internal cross validation (n=63). The equations obtained had low standard errors of cross-validation and moderate $R^2$ (coefficient of determination in calibration). Prediction of an external validation set (n=30) showed significant correlation between reference values and NIRS estimated values based on the SEP (standard error of prediction), $r^2$ (coefficient of determination in prediction) and the ratio of standard deviation (SD) of reference data to SEP. The models developed in this study had relatively higher values (more than 2.0) of SD/SEP(C) for oleic and linoleic acid, having good correlation between reference and NIRS estimate. The results indicated that NIRS, a nondestructive screening method could be used to rapidly determine fatty acid composition in sesame seeds in the breeding programs for high quality sesame oil.

NEW DEVELOPED PORTABLE NEAR INFRARED (NIR) SYSTEM USING MICROSPECTROMETER

  • Woo, Young-Ah;Ha, Tae-Kyu;Kim, Jae-Min;Kim, Hyo-Jin
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.1123-1123
    • /
    • 2001
  • In recent years, a miniature spectrometer has been extensively developed due to the marriage of fiber optics and semiconductor detector array. This type of miniature spectrometer has advantages of low price and robustness due to the capability of mass production and no moving parts are required such as lenses, mirrors and scanning monochromator. These systems are ideal for use in teaching labs, process monitoring and field analyses. A portable near infrared (NIR) system has been developed for qualitative and quantitative analysis. This system includes a tungsten halogen lamp for light source, a fiber optics connected a light source, and a sample module to the microspectrometer, The size of spectrometer can be as small as 2.5 cm x 1.5 cm x 0.1 cm. Wavelength ranges can be chosen as 360-800 nm, 800-1100 nm and 1100-1900 nm depending on the type of detector. The software consists of various tools for multivariate analysis and pattern recognition techniques. To evaluate the system, long and short-term stability, wavelength accuracy, and stray light have been investigated and compared with conventional scanning type NIR spectrometer. This developed system can be sufficiently used for quantitative and qualitative analysis for various samples such as agricultural product, herbal medicine, food, petroleum, and pharmaceuticals, etc.

  • PDF

분광복사조도 측정 장치 개발 (Development of Spectral Irradiance Measurement System)

  • 서정철
    • 조명전기설비학회논문지
    • /
    • 제18권5호
    • /
    • pp.48-53
    • /
    • 2004
  • 광원의 분광복사조도를 250∼1600[nm] 파장 영역에서 정확하게 측정하기 위한 분광복사조도 측정 장치를 개발하였다. 분광복사조도 측정 장치는 광원 장치, 광학계, 분광장치, 광검출장치, 신호 처리 장치 등으로 이루어져 있다. 광검출 장치는 PMT, Si, InGaAs 및 IR enhanced InGaAs 광검출기를 이용함으로써 자외선, 가시광선, 적외선을 포함하는 넓은 파장 범위에서 광원의 스펙트럼을 측정할 수 있다. 개발된 측정 장치를 이용하여 1[kW] quartz-halogen 텅스텐 전구의 분광복사조도를 측정하여 비교하였는데, 측정 결과와 NIST에서 측정된 결과와는 차이는 450∼700[nm] 파장 영역에서 3[%] 이하이며, 700∼1600[m] 파장영역에서는 3.5[%] 이하이며, 250∼400[nm] 파장영역에서는 5[%] 이하로 측정되었다.

펄스형 방전플라스마에서 발생하는 가시광선의 분광특성 연구 (Spectroscopy of Visible Light Emitted from Plasma Occurred by Pulse Discharge)

  • 최운상
    • 한국안광학회지
    • /
    • 제3권1호
    • /
    • pp.27-31
    • /
    • 1998
  • 펄스형 방전플라즈마 발생장치인 플라스마 포커스장치에서 발생하는 가시광선영역의 빛을 시간분해분석법과 시간적분분석법으로 분광분석하였다. 플라스마포커스장치는 전극이 동축형으로 사용되었고, 시간 용해분석법은 고정된 파장의 광펄스를 오실로스코프로 분석하였으며, 시간 적분법을 일정한 범위의 파장대를 필림에 현상하여 densitometer로 분석하였다. 가시광선발생은 방전전압과 기체압력을 변수로 측정하여 방전전압은 17 kV이고 기체압력은 아르곤기체일 경우 0.5 torr가 최적조건이었다.

  • PDF

근적외 분석법에 의한 참깨의 원산지 판별 (Identification of geographical origin of sesame seeds by near infrared spectroscopy)

  • 권영길;조래광
    • Applied Biological Chemistry
    • /
    • 제41권3호
    • /
    • pp.240-246
    • /
    • 1998
  • 근적외 분석법을 응용하여 참깨의 원산지 판별 가능성을 조사한 결과, 한국산, 중국산 및 일본산 참깨를 판별할 수 있었으며, 필터형 근적외 분석장치로도 연구용 장치와 비슷한 정확도로 참깨의 원산지를 판별할 수 있었다. 중국산 참깨가 혼합된 경우 혼입율은 10% 오차 범위에서 측정할 수 있었다. 근적외 분광분석법에 의해 참깨의 원산지가 판별되는 근거는 참깨의 기름성분 보다는 참깨박 성분에 그 요인이 있는 것으로 판단되었다.

  • PDF

보현산천문대 2K CCD 카메라의 특성 (CHARACTERISTICS OF THE BOAO 2K CCD CAMERA)

  • 박병곤;천무영;육인수;성현철
    • 천문학논총
    • /
    • 제16권1호
    • /
    • pp.31-36
    • /
    • 2001
  • We present the characteristics of the 2K CCD camera at the Bohyunsan Optical Astronomy Observatory of the Korea Astronomy Observatory at the time of its development. The purpose of this paper is to support the observers who may need detailed information on the characteristics of the camera and to provide helpful information on the optimization' of a CCD camera for those who try to develop their own camera. The 2K CCD camera was optimized to have a gain of $1.8e^-/ADU$ and a read out noise of $7e^-$ from an experiment using radioactive $^{55}Fe$ X-ray source. The charge transfer efficiency was measured as 0.9999976 for serial and 0.9999942 for parallel direction, which means $0.5\%$ charge loss along the serial direction and $1.2\%$ along the parallel direction across the chip. The quantum efficiency of the camera was measured from an experiment using a homogeneous light source consisting of a halogen lamp and an integrating sphere with a monochromator. The resulting quantum efficiency of the camera peaked at the wavelength range 600-700 nm with the value of $\~0.89$.

  • PDF

Determination of Protein Content in Pea by Near Infrared Spectroscopy

  • Lee, Jin-Hwan;Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • 제18권1호
    • /
    • pp.60-65
    • /
    • 2009
  • Near infrared reflectance spectroscopy (NIRS) was used as a rapid and non-destructive method to determine the protein content in intact and ground seeds of pea (Pisum sativum L.) germplasms grown in Korea. A total of 115 samples were scanned in the reflectance mode of a scanning monochromator at intact seed and flour condition, and the reference values for the protein content was measured by auto-Kjeldahl system. In the developed ground and intact NIRS equations for analysis of protein, the most accurate equation were obtained at 2, 8, 6, 1 math treatment conditions with standard normal variate and detrend scatter correction method and entire spectrum (400-2,500 nm) by using modified partial least squares regression (n=78). External validation (n=34) of these NIRS equations showed significant correlation between reference values and NIRS estimated values based on the standard error of prediction (SEP), $R^2$, and the ratio of standard deviation of reference data to SEP. Therefore, these ground and intact NIRS equations can be applicable and reliable for determination of protein content in pea seeds, and non-destructive NIRS method could be used as a mass analysis technique for selection of high protein pea in breeding program and for quality control in food industry.

액체 속에서의 고전압 펄스 플라즈마 발생 및 분광학적 플라즈마 특성연구

  • 박지훈;김용희;전수남;박봉상;최은하
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2013년도 제44회 동계 정기학술대회 초록집
    • /
    • pp.549-549
    • /
    • 2013
  • 고전압 펄스 플라즈마를 액체 속에서 발생시켜 수소 스펙트럼의 광학적 특성을 연구하였다. 고전압 펄스 발생 장치인 막스 제네레이터는 용량이 $0.5{\mu}F$인 축전기 5개로 이루어져 있다. 각각의 축전기는 전원 장치를 이용하여 저항을 통해 병렬로 충전되며, 방전 시에는 불꽃 방전 스위치에 의해 동시에 직렬로 연결되어 고전압을 발생시킨다. 따라서, 출력 전압과 전류는 40kV, 3 kA이며 총 에너지는 약 125 J이다. 직육면체 모양의 폴리카보네이트 용기 내부의 양쪽면에는 탐침 모양의 전극이 구성되어 있으며 전극 사이에서 고전압을 가진 플라즈마가 형성된다. 실험에서 액체로는 증류수를 사용하였다. 액체 방전 시 발생하는 수소 스펙트럼을 관측하기 위해 초점거리 30 cm의 monochromator를 이용하였고, 수소 알파선의 656.3 nm와 수소 베타선의 434.1 nm를 관측하였다. 전자 밀도의 측정법으로는 Stark broadening법을 이용하여 측정하였으며, 전자 온도는 Stark profile의 상대적인 전자 밀도의 비를 이용하여 계산하였다. 전자밀도는 실험조건에서 약 $3{\times}10^{15}cm^{-3}$, 전자온도는 약 2.5 eV가 측정되었다.

  • PDF

펄스형 방전플라스마에서 발생하는 가시광선의 분광(II) (Spectroscopy of visible light emitted from plasma occurred by pulse discharge(II))

  • 최운상;정수자;김용훈;장준규;정정복;신장철
    • 한국안광학회지
    • /
    • 제5권2호
    • /
    • pp.163-165
    • /
    • 2000
  • 펄스형 방전플라즈마 발생장치인 플라스마 포커스장치에서 발생하는 가시광선영역의 빛을 시간적분 분석법으로 분광 분석하였다. 플라스마 포커스장치는 펄스방전에 의해 전기에너지를 빛에너지로 발생시킬 수 있는 장치이다. 분광분석기는 초점거리가 0.5 m인 모노크로메터를 사용하였다. 시간적분 분석법은 분광된 일정한 범위의 가시광선영역의 파장대를 필름에 현상하여 densitometer로 분석하는 방법이다. 가시광선 발생은 방전전압과 기체압력의 최적조건에서 발생되었는데 방전전압은 13kV이고 아르곤과 헬륨기체가 가시광선영역의 빛을 발생시키는데 사용되었다.

  • PDF

EPD 신호궤적을 이용한 플라즈마 식각공정의 실시간 이상검출 (Real-time malfunction detection of plasma etching process using EPD signal traces)

  • 차상엽;이석주;고택범;우광방
    • 제어로봇시스템학회논문지
    • /
    • 제4권2호
    • /
    • pp.246-255
    • /
    • 1998
  • This paper presents a novel method for real-time malfunction detection of plasma etching process using EPD signal traces. First, many reference EPD signal traces are collected using monochromator and data acquisition system in normal etching processes. Critical points are defined by applying differentiation and zero-crossing method to the collected reference signal traces. Critical parameters such as intensity, slope, time, peak, overshoot, etc., determined by critical points, and frame attributes transformed signal-to symbol of reference signal traces are saved. Also, UCL(Upper Control Limit) and LCL(Lower Control Limit) are obtained by mean and standard deviation of critical parameters. Then, test EPD signal traces are collected in the actual processes, and frame attributes and critical parameters are obtained using the above mentioned method. Process malfunctions are detected in real-time by applying SPC(Statistical Process Control) method to critical parameters. the Real-time malfunction detection method presented in this paper was applied to actual processes and the results indicated that it was proved to be able to supplement disadvantages of existing quality control check inspecting or testing random-selected devices and detect process malfunctions correctly in real-time.

  • PDF