• Title/Summary/Keyword: Monitoring Data

Search Result 8,964, Processing Time 0.041 seconds

Cointegration based modeling and anomaly detection approaches using monitoring data of a suspension bridge

  • Ziyuan Fan;Qiao Huang;Yuan Ren;Qiaowei Ye;Weijie Chang;Yichao Wang
    • Smart Structures and Systems
    • /
    • v.31 no.2
    • /
    • pp.183-197
    • /
    • 2023
  • For long-span bridges with a structural health monitoring (SHM) system, environmental temperature-driven responses are proved to be a main component in measurements. However, anomalous structural behavior may be hidden incomplicated recorded data. In order to receive reliable assessment of structural performance, it is important to study therelationship between temperature and monitoring data. This paper presents an application of the cointegration based methodology to detect anomalies that may be masked by temperature effects and then forecast the temperature-induced deflection (TID) of long-span suspension bridges. Firstly, temperature effects on girder deflection are analyzed with fieldmeasured data of a suspension bridge. Subsequently, the cointegration testing procedure is conducted. A threshold-based anomaly detection framework that eliminates the influence of environmental temperature is also proposed. The cointegrated residual series is extracted as the index to monitor anomaly events in bridges. Then, wavelet separation method is used to obtain TIDs from recorded data. Combining cointegration theory with autoregressive moving average (ARMA) model, TIDs for longspan bridges are modeled and forecasted. Finally, in-situ measurements of Xihoumen Bridge are adopted as an example to demonstrate the effectiveness of the cointegration based approach. In conclusion, the proposed method is practical for actual structures which ensures the efficient management and maintenance based on monitoring data.

Ubiquitous Based Monitoring System for Efficient Data Management (효율적인 데이터관리를 위한 유비쿼터스 기반 모니터링 시스템)

  • Kim, Gui-Jung
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2006.11a
    • /
    • pp.516-519
    • /
    • 2006
  • In this paper, we designed data monitoring system using RFID for efficient data management of cinder reuse process, and for construction of unified system utilizing exact data. We constructed database, thesarus retrieval model to manage this database, and designed RFID model for monitoring system. The construction of data monitoring system for stable cinder reuse is the efficient method to develop realtime and automatic process.

  • PDF

Power Quality Monitoring Algorithm Using the Protective Relay (보호계전기를 이용한 전기 품질 감시 기법 연구)

  • Choi In. S.;Lee Kang. S.;Choi Myeon. S.;Lim Seong. I.;Lee Seung. J.
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.11
    • /
    • pp.581-588
    • /
    • 2004
  • Power qualify monitoring system is devoted to more concern than before, because the innovation of industrial technology needs more accurate instruments and more advanced power quality. This paper was studied on using data of the protective relay by Power Quality Monitor. This paper was proposed the wave storage condition and monitoring clauses of the protective relay as a power quality monitoring device. The protective relay will have problem to save data for PQM analysis because the protective relay memory is limited. Therefore this paper was proposed new a data compression of data got from the protective relay. This method is wave compression comparison algorithm using the DFT. The compression rate is higher than any other established method. This method can be real time storage. This algorithm is verified using the comparison among other compression rate and proved by Real Time Digital Simulator (RTDS).

The Development of Seismic Monitoring for a Base-Isolated Building System (지진격리 구조물의 지진모니터링 시스템 개발)

  • 김성훈;조대승;박해동;김두훈
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11a
    • /
    • pp.247-251
    • /
    • 2001
  • Nowadays, base isolation systems such as lead-rubber bearing, elastomer bearing and sliding bearing have been installed to the various structures to prevent the disaster from seismic. The performance of base isolation system have been well proved by model-scale experiments and numerical analysis. However. the seismic response data measured at real large base-isolated structures is still insufficient. This paper presents a seismic monitoring system, acquiring real-time acceleration signals up to 32 channels, displaying time history and spectrum of the signals, storing the acquired data at a PC hard disk, and replaying the saved data. Moreover, the system can be operated without any limitation for monitoring period by automatic management of stored data file. The developed system has been installed at a real base-isolated building using lead-rubber bearings and we expect its seismic response data with ground motion signal can be well licquired in case of earthquake occurrence.

  • PDF

Anomaly Test for Ozone Concentration Data from National Air Monitoring Stations (오존 자동측정망 자료 중의 이상치 점검)

  • 김영성
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.15 no.2
    • /
    • pp.139-150
    • /
    • 1999
  • The ozone concentrations measured at the National Air Monitoring Stations between 1990 and 1995 were reviewed to detect any anomalies in the measurements. By screening the cases, in which variation of the ozone concentration from the previous measured value is greater than 75ppb, 125 station-days were identified as the test cases for the anomaly test. Historical and parallel consistencies of the measured concentrations were examined by plotting data for each test case. The detected anomalies can be classified into four categories; single outliers, anomalous variations during the startup period, baseline rises, and fluctuations in th diurnal variations. Anomalies were detected in as many as 80 cases among 125 test cases. Because of these anomalies, the number of hours exceeding 100ppb in the areas other than the Greater Seoul Area(GSA) could decrease from 157 to 107. Further studies for developing the methodology for eliminating the abnormal monitoring data are warranted for the data from the National Air Monitoring Stations are official to the both inside and outside of the country.

  • PDF

Design of Management Structure Measuring Integrated Monitoring System Based on Linked Open Data

  • Min, Byung-Won;Okazaki, Yasuhisa;Oh, Yong-Sun
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2016.05a
    • /
    • pp.255-256
    • /
    • 2016
  • In this paper, we analyze the operations and/or status of our structure which builds the management structure measuring integrated monitoring system based on linked open data in a short term or long term bases. We have applied a novel analyzing method of linked open data to expect what movements can be occurred in the structure, and we improve the monitoring system using an integrated design to solve the drawbacks of conventional types of monitoring. And collecting data through cloud and their reliability can be proved by evaluation of soundness of data amount and their confidence.

  • PDF

Case Study of Design and Implementation for Hadoop-Based Integrated Facility Monitoring System (하둡 기반의 통합설비 모니터링시스템 설계 및 구현 사례 연구)

  • Kim, Sangrak;Jang, Gilsang;Cho, Chiwoon
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.40 no.1
    • /
    • pp.34-42
    • /
    • 2014
  • SCADA and DCS that have performed automatic control and monitoring activities increase the productivity of enterprise in industries. In such systems, although their performance had been improved, there are still many deficiencies in predictive maintenance which can foresee the risk of any kinds of accidents. Because the data acquisition systems of main facilities are being distributed throughout the whole plant and therefore, integration of data obtained from the systems is very difficult. Accordingly, techniques that acquire meaningful information from the gathered data through realtime analysis still need to be improved. This paper introduces a developed facility monitoring system which can predict equipment failure and diagnose facility status through big data analysis to improve equipment efficiency and prevent safety accidents.

Regional sea water chlorophyll distribution derived from MODIS for near-real time monitoring

  • Liew, S.C.;Heng, A.W.C.
    • Proceedings of the KSRS Conference
    • /
    • 2003.11a
    • /
    • pp.1039-1041
    • /
    • 2003
  • Ocean color products derived from remote sensing satellite data are useful for monitoring the sea water quality such as the concentrations of chlorophyll, sediments and dissolved organic matter. Currently, ocean color products derived from MODIS data can be requested from NASA over the internet. However, due to the bandwidth limitation of most users in this region, and the time delay in data delivery, the products cannot be use for near-real time monitoring of sea water chlorophyll. CRISP operates a MODIS data receiving station for environmental monitoring purposes. MODIS data have been routinely received and processed to level 1B. We have adapted the higher level processing algorithms from the Institutional Algorithms provided by NASA to run in a standalone environment. The implemented algorithms include the MODIS ocean color algorithms. Seasonal chlorophyll concentration composite can be compiled for the region. By comparing the near-real time chlorophyll product with the seasonal composite, anomaly in chlorophyll concentration can be detected.

  • PDF

Research on Railway Safety Common Data Model and DDS Topic for Real-time Railway Safety Data Transmission

  • Park, Yunjung;Kim, Sang Ahm
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.5
    • /
    • pp.57-64
    • /
    • 2016
  • In this paper, we propose the design of railway safety common data model to provide common transformation method for collecting data from railway facility fields to Real-time railway safety monitoring and control system. This common data model is divided into five abstract sub-models according to the characteristics of data such as 'StateInfoMessage', 'ControlMessage', 'RequestMessage', 'ResponseMessage' and 'ExtendedXXXMessage'. This kind of model structure allows diverse heterogeneous data acquisitions and its common conversion method to DDS (Data Distribution Service) format to share data to the sub-systems of Real-time railway safety monitoring and control system. This paper contains the design of common data model and its DDS Topic expression for DDS communication, and presents two kinds of data transformation case studied for verification of the model design.

A Study of Developing the On-line Data Aquisition System for Monitoring the Distribution Transformer (배전용 변압기 감시를 위한 온라인 데이터 취득 장치 개발)

  • Moon, Jong-Fil;Kim, Jae-Chul;Choi, Joon-Ho;Kim, Oun-Seok
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.464-466
    • /
    • 2001
  • In this paper, we developed the on-line Data Aquisition System(DAS) of distribution transformers using the hardware and monitoring program. The DAS consists of the top oil temperature sensing part, ambient temperature sensing part, load current sensing part, acoustic emission peak-value sensing part, acoustic emission pulse counter part, micro-processor part and wireless communication part. The Monitoring System consists of the communication setting, online monitoring and database construction part. The DAS send the data acquired from the some sensors of the distribution transformers to the host PC. The monitoring program of the host PC stores the data to database. And the monitoring system estimates the loss of life time for distribution transformer from the DB. Thus, it could be managed the career and the functional lifetime of the transformer more efficiently than existing methodologies.

  • PDF