• 제목/요약/키워드: Monitoring Criteria

Search Result 582, Processing Time 0.027 seconds

Factors Affecting Metabolic Syndrome in a Rural Community (한 농촌지역 주민들의 대사증후군 관련요인)

  • Kim, Jong-Im
    • Korean Journal of Health Education and Promotion
    • /
    • v.26 no.1
    • /
    • pp.81-92
    • /
    • 2009
  • Objectives: This study set out to investigate the relationship among the factors of metabolic syndrome diagnosis criteria, their risk factors including general characteristics, and the distribution of the diagnosis criteria and risk among the adult residents of a rural community. Methods: Among 1,968 residents, those who had three or more of the risk factors of metabolic syndrome, which include blood pressure, blood glucose, triglyceride, abdominal obesity, and HDL-C, were categorized as the metabolic syndrome group. And their correlations were analyzed. Results: As for the risk ratio with five factors of the metabolic syndrome diagnosis criteria, it was high according to age and smoking. In addition, the results show that body fat percentage, hs-CRP, insulin, BMI, PP2, total cholesterol, and W/Ht also had much impact on increasing the risk ratio of the metabolic syndrome diagnosis criteria. It turned out that metabolic syndrome was affected by the body mass index(BMI), insulin, waist to height ratio(W/Ht), and hs-CRP. It was 2.51 times crude odds ratio that BMI over the 25kg/m2 in the ratio of the fact of metabolic syndrome and adjusted for sex odds ratio 2.50times and W/Ht was 3.31times, adjusted for sex odds ratio 3.25 times. Conclusion: BMI, W/Ht and smoking of the general characteristics seem to have close relationships with high correlations between the metabolic syndrome diagnosis criteria and the risk factors. Thus there is an urgent need to evaluate them and take interventions and monitoring measures for the clustering of risk factors.

Assessment of Tumor Response to Therapy in Lymphoma Using $^{18}F$-FDG PET: Diagnostic Performance of $^{18}F$-FDG PET and Interval Likelihood Ratio PET and Interval Likelihood Ratio ($^{18}F$-FDG PET을 이용한 림프종 치료 반응 평가: $^{18}F$-FDG PET의 진단 성능 특성과 구간 우도비)

  • Kim, Chang-Guhn;Kim, Dae-Weung;Park, Moo-Rim
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.43 no.5
    • /
    • pp.369-385
    • /
    • 2009
  • In this paper, the authors intended to summarize briefly the features of lymphoma with regard to $^{18}F$-FDG PET for assessment of tumor response to therapy, to describe why assessment of treatment response should be performed, to review what method so far has been used in monitoring treatment response, to discuss what limitations of morphologic imaging criteria for assessing tumor response are, in compared with $^{18}F$-FDG PET, and to introduce recently proposed criteria for assessing tumor response in malignant lymphoma. And also the authors emphasize the need to understand the characteristics of diagnostic performance of $^{18}F$-FDG PET in several clinical settings in order to interpret $^{18}F$-FDG PET results appropriately, and to encourage the use of interval likelihood ratio to enhance clinical implications of test results which, in turns, allows referring physicians to understand the meaning of interpretation with easy. Until recently, treatment response has been assessed according to the morphologic criteria. Metabolic imaging with $^{18}F$-FDG PET was adopted to have important role for treatment assessment in IWC+PET criteria proposed recently by IHP. To accomplish this role, we should perform and interpret $^{18}F$-FDG PET according to IWC+PET criteria. It is important for referring physicians to understand the various limitations of $^{18}F$-FDG PET and pitfalls in PET interpretation, and to understand that clinical information are needed by nuclear medicine physicians to optimize the interpretation of $^{18}F$-FDG PET.

Overseas Design Introduction of Road Rehabilitation Project in Keshim~Faizabad, Afghanistan (아프가니스탄 케심-파이자베드간 도로복구사업 해외설계 사례)

  • Jeong, Dong-Ho;Kim, Woo-Sun;Kim, Gee-Baek;Jeong, Won-Joon;Lee, Seung-Woo
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2008.10a
    • /
    • pp.569-580
    • /
    • 2008
  • If slope height was more than 20 meters, we conducted an analysis of stereographic projection and limit equilibrium at this slope. We proposed reduction of slope face angle and reinforcement of rock bolt depending on analysis. Blasting design : Standard pattern based on result of local test blasting was made for blasting design. Vibration criterion was set for less than 3.0mm/s because of outworn buildings and inhabitants opinions. Production blasting and Controlled blasting has been done as Construction standard pattern. After Vibration Monitoring has been done, so that we can control of complement. "Bidding Document" and AASHTO 2001 "A Policy on Geometric Design of Highways and Streets" were so for design criteria of earthwork but they were different actual design criteria and left something to be desired in Afghanistan. Therefore, although "Bidding Document" and "AASHTO 2001" were basic design criteria, domestic design criteria was reflected in this design criteria for complement by discussion with supervisor. Drainage design : For stability ratio, ditch of arch block and stonework was designed by rainfall data for the 13 years and discussion with supervisor. Pavement was designed as flexible pavement. Because these days in Afghanistan postwar repair works, especially urgent repairing of roads and newly making of roads, are very highly in progress, I think that Afghanistan is the region about which our construction technical experts should have great concerns.

  • PDF

Improvement of Drought Operation Criteria in Agricultural Reservoirs (농업용 저수지 이수관리를 위한 저수율 가뭄단계기준 개선)

  • Mun, Young-Sik;Nam, Won-Ho;Woo, Seung-Beom;Lee, Hee-Jin;Yang, Mi-Hye;Lee, Jong-Seo;Ha, Tae-Hyun
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.64 no.4
    • /
    • pp.11-20
    • /
    • 2022
  • Currently, the operation rule of agricultural reservoirs in case of drought events follows the drought forecast warning standard of agricultural water supply. However, it is difficult to preemptively manage drought in individual reservoirs because drought forecasting standards are set according to average reservoir storage ratio such as 70%, 60%, 50%, and 40%. The equal standards based on average water level across the country could not reflect the actual drought situation in the region. In this study, we proposed the improvement of drought operation rule for agricultural reservoirs based on the percentile approach using past water level of each reservoir. The percentile approach is applied to monitor drought conditions and determine drought criteria in the U.S. Drought Monitoring (USDM). We applied the drought operation rule to reservoir storage rate in extreme 2017 spring drought year, the one of the most climatologically driest spring seasons over the 1961-2021 period of record. We counted frequency of each drought criteria which are existing and developed operation rules to compare drought operation rule determining the actual drought conditions during 2016-2017. As a result of comparing the current standard and the percentile standard with SPI6, the percentile standard showed severe-level when SPI6 showed severe drought condition, but the current standard fell short of the results. Results can be used to improve the drought operation criteria of drought events that better reflects the actual drought conditions in agricultural reservoirs.

Building capacity for ecological assessment using diatoms in UK rivers

  • Kelly, Martyn
    • Journal of Ecology and Environment
    • /
    • v.36 no.1
    • /
    • pp.89-94
    • /
    • 2013
  • Diatoms have become an integral part of the UK's freshwater monitoring strategy over the past two decades, mostly in response to increasingly stringent European Union (EU) legislation. The use of diatoms is based on strong correlations between diatom assemblages and environmental variables, and from knowledge of the "expected" (= "reference") state of each river. The nationwide overview of the ecological health of rivers this gives allows those stretches of rivers which fail to meet EU criteria to be identified. This, in turn, allows appropriate remediation measures to be planned. Because diatom assemblages vary in space and time, even within a single water body, effective use of diatoms requires a consistent approach in order to minimise uncertainty. This includes the use of methods which comply with European Standards, a training and accreditation scheme for analysts, and a suite of quality assurance methods. Those aspects of uncertainty that cannot be readily controlled have been quantified and all estimates of ecological status are accompanied by the appropriate "confidence of class" and "risk of misclassification". This, in turn, helps planners prioritise those locations which are most likely to benefit from remediation.

The intermediate Effects of Control System on the Relationship between Quality Strategy and Performance (품질전략과 경영성과간의 관계에서 통제시스템의 매개효과)

  • 김달곤
    • Journal of Korean Society for Quality Management
    • /
    • v.30 no.3
    • /
    • pp.150-167
    • /
    • 2002
  • Normative theory suggests that control systems should be designed to complement management's objectives and strategies. However, few empirical studies have focused on how control systems have been modified to complement new manufacturing techniques, such as zero-defect strategy. The major purpose of this study is to examine the effects of the attributes of quality strategy and control system on performance. The previous studies have subdivided quality strategy into the ECL(economic conformance level) and ZD(zero-defect) strategy. To accomplish the purpose, this study empirically analysed the data based on the questionnaires from manufacturing department personnel of 67 Korean companies. The major results are as follows. The companies that had implemented the ZD strategy and its control system outperformed the companies that had implemented ECL strategy. Also, the ZD strategy differs from ECL strategy in control system, the criteria of performance evaluation and feedback frequence variable. There is no difference in quality performance monitoring and communication variable. From this results, although many companies have strived for continuous improvement of quality, it was restricted in improvement activities that dont's required much investment cost, quality performance monitoring and communication.

Review on the Relationship of Dissolved Gas Analysis and Internal Inspection of Transformer (변압기 절연재료 분석과 내부점검 결과와의 상관성 연구)

  • Park, Hyun-Joo;Nam, Chang-Hyun;Jung, Nyun-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.10
    • /
    • pp.1869-1873
    • /
    • 2010
  • For reliable operation of oil-filled electrical equipment, monitoring and maintenance of insulating oil is essential. Dissolved gas analysis(DGA) is widely used for monitoring faults in high voltage electrical equipment in service. Therefore, oil analysis should be monitored regularly during its service life. KEPCO has investigated thousands of dissolved gas analysis data since 1985, and conducted studies on the relationship of gas in oil analysis and internal inspection results of transformer. As the results, KEPCO revised criteria for transformer diagnosis and has applied it since 2008. Almost of 100 cases of internal inspection results since 2001 have been investigated. This paper presents the correlation of the fault-identifying gases with faults found in actual transformers and how should we approach to internal inspection of transformer by dissolved gas analysis.

Towards an Effective Assessment of Safety Culture (안전문화 평가방안 연구)

  • Hong, In-gie;Baek, Jong-bae
    • Journal of the Korean Society of Safety
    • /
    • v.31 no.1
    • /
    • pp.118-125
    • /
    • 2016
  • The purpose of this study is to identify issues for an effective safety culture assessment by conducting a case study of an electronics manufacturing plant in Korea. Cooper's safety culture model was used as the assessment method, and Fleming and Hudson's safety culture maturity models were applied as assessment criteria. The results of the safety culture assessment showed that there needs to be a design optimized for study purposes. For example, the correlation between the questionnaire survey and in-depth interview needs to be analyzed. The result of the behavior monitoring should show the relationships with other dimensions. A safety culture maturity model has to be developed to customize the study factors and questions.

Compaction Management Criteria for Fill Materials of Concrete Faced Rockfill Dam (CFRD 축조재료의 다짐관리 기준)

  • Kim, Yong-Seong;Park, Han-Gyu;Lim, Heui-Dae
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.343-348
    • /
    • 2005
  • In this study, construction modulus, void ratio and settlement characteristics of 38 CFRD in domestic and foreign countries was investigated from monitoring data and the effect of field dry density and void ratio to dam body was analyzed. The standard void ratio of CFRD that can be easily used for dam designer and field engineer was proposed from the monitoring data. It was conformed that we can get the degree of compaction needed for reasonable compaction of dam body by calculating the field dry density from inverse operation of the standard void ratio. It was thought that the standard void ratio of CFRD is 0.2 as shape factor is under 4 and is 0.28 as shape factor is over 4.

  • PDF

The Development of the Slope Monitoring System(SMS) of the Tower Crane (타워크레인의 기울어짐 측정 시스템 개발)

  • Shin, Woon-Chul;Hong, Yong-Soo
    • Journal of the Korean Society of Safety
    • /
    • v.25 no.6
    • /
    • pp.60-64
    • /
    • 2010
  • The purpose of this study if to prevent dangerous accident of the overthrow of the tower crane in summer's hurricane. We develop the SMS in order to give automatic alarm system to operator within the dangerous range and to give a information of the exactly slope in the real time. The slope value of the tower crane is compose of direction, pitch by the front and rear, roll by the right and left and synthesis by the its pitch and roll. Especially, the synthesis eliminate the effect of the wall tie or wire bracing. So, this value should correctly indicate the actual slope. In this study, more applying field test should be applied with the SMS. In the future, a more measurement device can be applied to, and be able to feed more alarm criteria for the review of the risk in the field.