• Title/Summary/Keyword: Monitor

Search Result 7,367, Processing Time 0.031 seconds

A study on the development of standard-time receiving device for process computer (공정용 컴퓨터를 위한 표준시각 수신장치 개발에 관한 연구)

  • 홍용표;손창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.592-596
    • /
    • 1988
  • PCS(Process Computer System) is installed to monitor various kinds of process parameters in Power Plant and networked for synthetic monitor and event analysis in all site. But when an event is occured sequentially or simultaneously among the plants, it is difficult to analyze it because of different Standard-Time in each Plant. Standard-Time Receiving Device is developed to solve this problem and development procedure is descried here.

  • PDF

A study on the development of standard-time receiving device for process computer (공정용 컴퓨터를 위한 표준시각 수신장치 개발에 관한 연구)

  • 홍용표;손창호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.385-389
    • /
    • 1988
  • PCS(Process Computer System) is installed to monitor various kinds of process parameters in Power Plant and networked for synthetic monitor and event analysis in all site. But when an event is occured sequentially or simultaneously among the plants, it is difficult to analyze it because of different Stardard-Time in each plant. Standard-Time Receiving Device is developed to solve this problem and development procedure is described here.

  • PDF

Relationship between Take-off Behavior of Hard-disk Slider and AE Signal (하드디스크 슬라이더의 부상 특성과 AE신호의 관계)

  • 이상민;문재택;김대은
    • Tribology and Lubricants
    • /
    • v.17 no.1
    • /
    • pp.40-55
    • /
    • 2001
  • Acoustic emission(AE) signal has been widely utilized to monitor the interaction at the head/disk interface. In this work the relationship between the AE signal and the state of contact between the slider and the disk is presented. Results of the FFT(Fast Fourier Transform) analyses of the AE signal could be used to better understand the interfacial interaction. Also, it was found that wear particles affect the AE signal. Therefore, the signal can be used to monitor the wear particle presence at the interface.

Design and Implementation UPS Management System in HFC Network (HFC 전송망을 이용한 UPS 원격관리 시스템의 설계와 구현)

  • 김영화;강준우
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.75-78
    • /
    • 2002
  • Since power failures in high-speed communication network, especially in HFC(Hybrid Fiber Coaxial cable) network are critical, microcontroller-based UPS(Uninterrupted Power Supply) are commonly used in the network. Hardware and software of UPS management system is designed and implemented to monitor and control UPS status to supply electric power to ONU and TBA in the HFC network. The result of laboratory tests and field tess of this system shows the scan rate to be 1 to 10 minutes to sufficiently monitor the status of UPS in the network.

  • PDF

Development of Respiration Monitor using Impedance Pneumograph (Impedance Pneumograph법을 이용한 호흡 감시장치의 개발)

  • 고한우;이건기
    • Journal of Biomedical Engineering Research
    • /
    • v.5 no.1
    • /
    • pp.15-18
    • /
    • 1984
  • In this paper we developed a respiration monitor by an impedane pneumography. This technique, measuring the electrical impedance change of the lungs due to breath, provides the accurate data for the respiration trend and rates. To measure the small impedance difference we designed a special current source which was considered the electrical safety and the interference with the ECG signal.

  • PDF

Relationship between Take-off Behavior of Hard-disk Slider and AE Signal (하드디스크 슬라이더의 부상 특성과 AE신호의 관계)

  • 이상민;문재택;김대은
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 1999.11a
    • /
    • pp.310-317
    • /
    • 1999
  • Acoustic emission(AE) signal has been widely utilized to monitor the interaction at the head/disk interface. In this work the relationship between the AE signal and the state of contact between the slider and the disk is presented. Results of the FFT analyses of the AE signal could be used to better understand the interfacial interaction. Also, it was found that wear particles affect the AE signal. Therefore, the signal can be used to monitor the wear particle presence at the interface.

  • PDF

A Study for Selecting Optimum Injection Point of the Monitor Cover (모니터 커버 설계를 위한 최적의 사출 위치 선정에 관한 연구)

  • 이태홍;이성수
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 2000.10a
    • /
    • pp.157-162
    • /
    • 2000
  • The object is design an optimal injection position on the Monitor Cover. In this paper, the defined injection position are three types, which simulate in melting temperature, molding temperature and weld line in variation. We obtained a result from simulation and descried the result related injection pressure with injection position.

  • PDF

Evaluation of IMG level 2 data using GTS

  • Tokunaga, Mitsuharu
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.242-245
    • /
    • 1998
  • Interferometric Monitor for Greenhouse Gases (IMG) is a sensor to monitor the earth's radiation balance, the temperature profile of the atmosphere, the temperature of the earth's surface, and physical properties of clouds, and was loaded on ADEOS satellite. In this paper, we estimated IMG level 2 data by comparing with a Clobal Telecommunications System data (GTS). The IMG level 2 data over sea without cloud cover gave good agreement with the value that had been obtained by buoy and sonde.

  • PDF

Application of On-line System for Monitoring and Forecasting Surface Changes for Korean Peninsula

  • Lee, Sang-Hoon
    • Proceedings of the KSRS Conference
    • /
    • 1998.09a
    • /
    • pp.268-273
    • /
    • 1998
  • This study applies an on-line system, which employes an adaptive reconstruction technique to monitor and forecast ocean surface changes. The system adaptively generates an appropriate synthetic time series with recovering missing measurements for sequential images. The reconstruction method incorporates temporal variation according to physical properties of targets and anisotropic spatial optical properties into image processing techniques. This adaptive approach allows successive refinement of the structure of objects that are barely detectable in the observed series. The system sequentially collects the estimated results from the adaptive reconstruction and then statistically analyzes them to monitor and forecast the change in surface characteristics.

  • PDF

A Novel WV-TN with Wide Viewing Angle and Fast Response Time for Multi-Functional Monitor

  • Jeong, J.K.;Lee, D.J.;Jung, T.B.;Ko, T.W.;Choi, H.C.;Lee, S.W.
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 2005.07a
    • /
    • pp.294-296
    • /
    • 2005
  • We developed new WV-TN panel which has 170/170 viewing angle and 8ms response time. This viewing characteristics almost catch up with those of VA. To extend the viewing angle we optimized the cell design and LC parameters. This new technology strongly increase the demand of TN monitors especially for the monitor market larger than 19"

  • PDF