• Title/Summary/Keyword: Monitering Control

Search Result 44, Processing Time 0.027 seconds

Development of Power Management System for Efficient Energy Usage of Small Generator (소형 발전기의 에너지 절약을 위한 전력관리 시스템 개발)

  • Jeon, Min-Ho;Oh, Chang-Hyun
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.12
    • /
    • pp.2601-2606
    • /
    • 2012
  • In this paper, an electricity management system, which saves energy by utilizing electricity consumption of load from an environment that uses at least two compact generators, is proposed and developed. A hardware is constructed by using TMS320C6713 DSP chip made by TI that is capable of high speed hardware floating point processing while serial communication is used for communication with a monitoring PC. Manual control is made possible from the monitoring PC and automatic on/off is enabled in the generator by using data collected by CT/PT sensor from the DSP mainboard. Test results confirm that the electricity management system proposed in this study functions without abnormality. The application of an algorithm that saves energy by using electricity consumption of load also allows for a longer supply of electricity compared to continuously using two compact generators.

Design of Algorithms for Unnecessary Sensor Barrier in IoT Environment (IoT 환경에서 불필요한 센서 차단 알고리즘 설계)

  • Lim, Hyeok;Shin, Yun-Ho;Yu, Dong-Gyun;Ryu, Seung-Han;Jung, Hoe-Kyung
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.607-608
    • /
    • 2016
  • Recently using a variety of sensors sensing the virtual(Virtual Sensing) technology that extracts specific data has been applied to IoT service interface. The utilization of such sensors while increasing IoT (Internet of Things) environmental sensor is an essential element. However, used in the IoT to the environment, while the increase in utilization of a specific sensor utilization falling sensors is generated. In this paper, we design unnecessary sensors removal algorithm as a way to solve this problem. Through the utilization of poor power to block the sensor can reduce the power consumption and user sensor control service through the monitoring by blocking the use of the sensor is considered that there can be provided a more effective and convenient.

  • PDF

Radiology Department Infection Control According to Radiography Frequency and Disinfection Period (촬영 빈도수 및 소독 주기에 따른 영상의학과 감염 관리)

  • Lee, Jae-Seung;Jeong, Kyu-Hwan;Kim, Gyoung-Hee;Im, In-Chul;Kweon, Dae-Cheol;Goo, Eun-Hoe;Dong, Kyung-Rae;Chung, Woon-Kwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.2
    • /
    • pp.73-80
    • /
    • 2011
  • Questionnaires were distributed to Radiology departments at hospitals with 300 sickbeds throughout the Pohang region of North Gyeongsang Province concerning awareness and performance levels of infection control. The investigation included measurements of the pollution levels of imaging equipment and assistive apparatuses in order to prepare a plan for the activation of prevention and management of hospital infections. The survey was designed to question respondents in regards to personal data, infection management prevention education, and infection management guidelines. The ATP Public Heath Monitering System was used to measure seven items for pollution levels of imaging equipment and assistive apparatuses in the Radiology Department. Data was analysed using SPSS version 12.0 for paired t-test and Pearson coefficient with a statistically significant level of 0.05. The results of the survey showed a total awareness level of infection management prevention education averaged at $3.73{\pm}0.64$ and performance levels resulted at $3.39{\pm}0.83$ which were statistically significant (p = 0.01). Also the measurements of pollution levels for equipment with high patient contact showed a Pearson Coefficient of over 0.5 implying a focus on pathogenic bacterium. There was no statistical significance with the frequency of imaging (p < 0.05). Therefore for general hospitals with high patient contact, there is a need to supply analyzing equipment for real time monitoring and the implementation of disinfection management that uses a Ministry of Health and Welfare approved antiseptic solution twice every minute.

A Indoor Management System using Raspberry Pi (라즈베리 파이를 이용한 실내관리 시스템)

  • Jeong, Soo;Lee, Jong Jin;Jung, Won Ki
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.9
    • /
    • pp.745-752
    • /
    • 2016
  • In the era of the Internet of Things, where all physical objects are connected to the Internet, we suggest a remote control system using a Raspberry Pi single-board computer with ZigBee, which can turn an indoor light-emitting diode (LED) and a multiple-tap on and off, and with a smart phone can control the brightness of the LED as well as an electronic door lock. By connecting an infrared (IR) transmitter module to the Raspberry Pi, we can control home appliances, such as an air conditioner, and we can also monitor indoor images, indoor temperatures, and illumination by using a smart phone app. We developed a method of finding out IR transmission codes required for remote-controllable appliances with an AVR micro-controller. We suggest a method to remotely open and shut an office door by novating the door lock. The brightness level of an LED (between 0 and 10) can be controlled through a PWM signal generated by an ATmega88 microcontroller. A mutiple-tap is controlled using an ATmega32, a photo-coupler, and a TRIAC. The signals for measured temperature and illumination are converted from analog to digital by using the ATtiny44A microcontroller transmitting to a Raspberry Pi through SPI communication. Then, we connect a camera to the CSI head of the Raspberry Pi. We can turn on the smart multiple-tap for a certain period of time, or we can schedule the multi-tap to turn on at a specific time. To reduce standby power, people usually pull out a power code from multiple-taps or turn off a switch. Our method helps people do the same thing with a smart phone, if they are away from home.

Implementation of Sensor Controller and Monitering System Using Film Type (필름형 센서를 이용한 센서 제어기 및 모니터링 시스템 구현)

  • Park, No-Jin;Lee, Ho-Woong;Yu, Hong-Kyeun
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.12 no.1
    • /
    • pp.51-57
    • /
    • 2013
  • Leak detection, the system is controlled by humanity's precious water resources, prepare for natural disasters and prevent damage to buildings and various industrial facilities. Especially because it causes serious environmental pollution, chemicals or oil spills, leak detection of various liquid(oil, water), the point at which the liquid leak is detected early on, and minimize environmental pollution, prevent damage of the equipment due to the leak, and the country's precious water resources to be used safely. In this paper, we solve these problems by using specialized film sensor, any person who is not a skilled technician, equipment or walls anywhere can be easily installed. also reduce unnecessary circuit, If film sensor is connected to operate, have a big competitive price, the detection of liquid and the surrounding environment according to, the sensor film that can set the sensitivity control, and monitoring system was implemented.

Monitoring of Brominated Flame Retardants (BFRs) for the management of Their Contamination in Environments (브롬화 난연제의 환경오염도 관리 방안)

  • Kim, Yong-Bum;Lee, Sang-Hoon;Chung, Yong
    • Journal of Environmental Impact Assessment
    • /
    • v.14 no.2
    • /
    • pp.83-96
    • /
    • 2005
  • Brominated flame retardants have the market share of 40%, comparing others because of their low cost and highly effective retardation against the flame. However, their toxic effects in human and properties of the accumulation in the environments have been issued among the international organization such as EU, OECD and etc. It, therefore, was surveyed the classification, toxic effects, and the usage of Brominated flame retardants, the trends for their managements in the world and Korea, and their contaminated levels in Korean Peninsula. In addition, the management directions for them were proposed. Penta, octa, and deca-BDE among brominated retardants will seem to be prohibited by the regulation as a flame retardants for plastics in Europe because of their toxic effects. Although Penta and Octa BDEs was used marginally in Korea, deca-BDE was 27% of brominated flame retardants (49,050 ton) which had been used in 2002. However, risk assessment for brominated retardants might not launched in Korea, yet. These reports demonstrate that toxic brominated retardants such as PBDEs will be assessed for their usage and the level of contamination in the environment in the area of the point sources like the industrial areas, incinerators and etc. However, the law to regulate the hazardous chemicals seems not to be dictated the monitoring of their contamination in the environment. We, therefore, suggest how to evaluate and to monitor the toxic contaminants with EIA (Environmental Impact Assessment) and LCA (Life Cycle Assessment) system. Further, to establish the management system of BFRs (such as the monitering of contamination levels in environments, life cycle assessment, and risk assessment for the toxic chemicals), It can be recommended the law to deal with the method analyzing chemicals will be established, which contains QA/QC (Quality Assurance and Quality Control) to evaluate the analytic capability of the companies to prepare EIS (Environment Impact Statement) or other institutes for analyzing chemicals.

Development of a Prototype System for Active Emergency Call Services (능동적 응급 호출 서비스 시스템 프로토타입 개발)

  • Han, Won-Hee;Song, Eun-Ha;Han, Sung-Kook;Jeong, Young-Sik
    • Journal of Korea Multimedia Society
    • /
    • v.11 no.7
    • /
    • pp.1016-1024
    • /
    • 2008
  • In this paper, we designed and implemented the ACE(ACtive Emergency call service system) system for emergency call service actively. ACE system has two physical components; E-Device(Emergency Mobile Device) and E-Server(Emergency Server). The role of E-Device is the mobile device in order to call emergency by using mild handi-capped, the elderly and children who are able to communicate theirs intention to another. E-Server is the server for management E-devices with realtime monitering. E-Device will be developed to the portable size for easily mild handi-capped, the elderly and children. When they need the service of emergency call, the button of E-device can be used and the call signal is transmitted to the emergency office and the guardian through Internet and CDMA. E-server should be developed the integrated control system for management of E-Devices basically. And it also supported to realtime monitoring of E-devices with respect to high quality of emergency call service for rise the efficiency.

  • PDF

Status of Ready-Mixed Concrete Plants and Raw Materials in Pusan (부산지역 레미콘 플랜트 및 원재료 현황)

  • Yoo, Seung-Yeup;Koo, Ja-Sul;Lee, Yang-Soo;Moon, Hyung-Jae;Kim, Jung-Jin;Park, Soon-Jeon
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.641-644
    • /
    • 2008
  • This paper investigated the plant and raw material of the ready-mixed concrete company which could supply to the second Lotte World on Pusan. the results were summarized as following. Almost plants were mainly using Twin shaft mixer which was 210m$^3$/hr and horizontal type. There was different the number of admixture silos at each plants, and they were separated by types. The mixtures mainly consisted of the ordinary portland cement, fly ash and blast furnace slag. For favorable quality control, each materials had to carry from same factories, and the monitering standard for quality control should be prepared. The coarse aggregates were used with many different producing districts, so they were only used from Y caused by exclusion of quality difference. The crushed, washed and river sands were generally used as fine aggregates, so the fine aggregates which could be possible to supply stable quality were chosen. This study used Poly Carbonic Acid Admixture which was developed to satisfy maintenance of performance till 2 hours and 10MPa at 15 hours.

  • PDF

Comparison of Intraoperative Somatosensory Evoked Potential(SSEP) Monitoring During Aneurysm Surgery : ACA Aneurysms vs MCA Aneurysms (전대뇌동맥과 중대뇌동맥 동맥류 수술시 체성감각유발전위의 모니터링의 비교, 분석)

  • Choi, Kwang Yeong;Kim, Gook Ki;Lim, Young Jin;Kim, Tae Sung;Leem, Won;Rhee, Bong Arm
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.sup2
    • /
    • pp.281-288
    • /
    • 2001
  • Objectives : The purpose of this study is to evaluate the usefulness of SSEP monitoring during intracranial aneurysm surgery and compare the characteristics of wave change in relation to neurologic changes between ACA aneurysms and MCA aneurysms. Methods : During recent three years(between January 1997 and November 1999), intraoperative SSEP monitoring had been done in 63 operations for intracranial aneurysms. We had monitored the median nerve SSEP during surgery for aneurysms of MCA and the posterior tibial nerve SSEP for aneurysms of ACoA or ACA. A more than 50% reduction of any cortical SEP response was considered to be a significant SEP change, compared to its baseline value before the start of surgery. Changes in the SEPs were categorized as follows : Type IA, no significant amplitude changes without temporary clipping ; Type IB, no significant amplitude changes with temporary clipping ; Type II, significant changes with temporary clipping and complete return to control amplitude ; Type III, significant changes with temporary clipping and incomplete return to control amplitude ; Type IV, significant changes with temporary clipping and more decreased amplitude changes. Results : Among the 63 intraoperative monitoring, there were 37 cases of ACA aneurysms(An), and 26 of MCA An. The temporary proximal arterial occlusion during surgery were performed in 31(83.8%)cases of ACA An, 22(84.6%) of MCA An. Seven of the 31 ACA An(22.6%) and ten of the 22 MCA An(45.5%) had significant changes. The type were as follows : 4 patients with type II and 3 with type III in the ACA An ; 3 patients with type II and 3 with type III and 4 with type IV in the MCA An. In both group type II changes had no new postoperative neurological deficit. All 6 patients with type III had new neurological deficits ; However, One case in the ACA An and two cases in the MCA An. had transient neurologic deficit and improved markedly over the next two months. All 4 type IV changes in the MCA An. had permanant neurologic deficits. Two out of 30 cases(6.7%) in the ACA An. and one out of 16 cases(6.3%) in the MCA An. without significant amplitude change had new neurologic deficit postoperatively. Conclusion : Based on this study, Intraoperative SSEP monitoring during aneurysm surgery would provide useful information for detecting cerebral ischemia. SSEP response during surgery for MCA An. is more sensitive than ACA An. Otherwise, there were no meaningful difference in rate of false negativity.

  • PDF

Design and Implementation of Bio-data Monitering System Based on ISO/IEEE 11073 DIM/REST for IoT Healthcare Service (IoT 헬스케어 서비스를 위한 ISO/IEEE 11073 DIM/REST 기반 생체정보 모니터링 시스템 설계 및 구현)

  • Choi, Ju-Hyun;Chun, Seung-Man;Jang, Dong-Hyun;Park, Jong-Tae
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.3
    • /
    • pp.3-12
    • /
    • 2015
  • Recently, various studies have been attempted to provide a biological information monitoring service through integrating with the web service. The medical information transmission standard ISO/IEEE 11073 PHD defines the optimized exchange protocol ISO/IEEE 11073-20601 based on the No-IP to exchange the biometric information between the ISO/IEEE 11073 agent and the manager. It's system structure based on the No-IP using ISO/IEEE 11073-20601 is not suitable for providing a remote biological information monitoring services. That is because it is difficult to provide to control and manage the biological information measurement devices, which have installed IP protocol stack at the remote. Furthermore, ACSE and CMDISE in ISO/IEEE 11073-20601 are not suitable to provide U-healthcare services based on IoT because they are complicated and difficult to implement it caused by the structural complexity. In order to solve the problems, in this paper, we propose the biological information monitoring architecture based on ISO/IEEE 11073 DIM/REST of IoT environment to provide the biological information monitoring service based on IoT. To do this, we designed biological information monitoring system architecture based on IoT and the message exchange protocol of ISO/IEEE 11073 DIM/REST between the ISO/IEEE 11073 agent and the ISO/IEEE 11073 manager. In order to verify the realistic possibility of the proposed system architecture, we developed the service prototype.