• 제목/요약/키워드: Moment capacity

검색결과 931건 처리시간 0.029초

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

Evaluation of ductility capacity of steel-timber hybrid buildings for seismic design in Taiwan

  • Chen, Pei-Ching;Su, I-Ping
    • Earthquakes and Structures
    • /
    • 제23권2호
    • /
    • pp.197-206
    • /
    • 2022
  • Recently, steel-timber hybrid buildings have become prevalent worldwide because several advantages of both steel and timber structures are maintained in the hybrid system. In Taiwan, seismic design specification related to steel-timber hybrid buildings remains void. In this study, the ductility capacity of steel-timber hybrid buildings in Taiwanese seismic design specification is first proposed and evaluated using nonlinear incremental dynamic analysis (IDA). Three non-linear structural models, 12-story, 8-story, and 6-story steel-timer hybrid buildings were constructed using OpenSees. In each model, Douglas-fir was adopted to assemble the upper 4 stories as a timber structure while a conventional steel moment-resisting frame was designated in the lower part of the model. FEMA P-695 methodology was employed to perform IDAs considering 44 earthquakes to assess if the ductility capacity of steel-timber hybrid building is appropriate. The analytical results indicate that the current ductility capacity of steel moment-resisting frames can be directly applied to steel-timber hybrid buildings if the drift ratio of each story under the seismic design force for buildings in Taiwan is less than 0.3%. As a result, engineers are able to design a steel-timber hybrid building straightforwardly by following current design specification. Otherwise, the ductility capacity of steel-timber hybrid buildings must be modified which depends on further studies in the future.

비대칭 슬림플로어 합성보의 내화성능 산정에 관한 해석적 방법 연구 (A Study on the Analytical Method for Fire Resistance Calculation of Asymmetric Slimfloor Beam)

  • 박수영;박원섭;김흥열;홍갑표
    • 한국화재소방학회논문지
    • /
    • 제24권2호
    • /
    • pp.31-37
    • /
    • 2010
  • 비대칭 슬림플로어 합성보(Asymmetric Slimfloor Beam, 이하 ASB)는 비대칭 형강의 일부를 콘크리트 슬래브에 삽입한 합성보로서, 유럽에서 개발되었다. 근래 국내에서도 건축물의 층고저감, 물량감소, 내화 성능 증대 등의 목적으로 ASB의 연구가 진행되고 있다. 본 연구에서는 실험을 통하여 ASB의 내화성능을 확인하고, 열전달해석을 통하여 내화성능 시간에서의 모멘트 내력(Moment capacity)을 산정하였다. 그 결과를 바탕으로 방화석고보드와 ASB로 구성된 3시간 내화구조를 선정하고, 내화 성능을 검토하였다.

A Modified Shooting Method Technique for the Analysis of the Limited Slip Capacity of UHPFRC-NC Composite Structure

  • Han, Sang-Mook;Wu, Xiangguo;Kim, Sung-Wook;Kang, Su-Tae
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.1061-1064
    • /
    • 2008
  • Shear connectors have a finite slip capacity because of the mechanism by which they transfer the shear between UHPFRC and NC elements. At high degree of shear connection, non-linear analysis techniques are required to allow for compressive plasticity and tensile cracking behaviour of the elements. As with all non-linear problems, a closed form solution is difficult to find. A Modified Shooting Method Technique is developed here for non-linear analysis of UHPFRC/concrete composite. The initial effective moment is derived according to the prestressing force. The composite structure is divided into small segments which length is much less than the length of the structure and it can be assumed that the forces and displacements within each segment are constant. An equivalent analysis in composite girders would be to fix the slip strain in each segment and develop a moment curvature relationship for this slip strain in each segment. Additive forces and moment analysis on each section of the segments are analyzed by MSMT. Finally the ultimate slippage of the interface can be evaluated by the MSMT model. This paper presents a nonlinear analysis method for limited slip capacity of UHPFRC-NC interface.

  • PDF

Initial stiffness and moment capacity assessment of stainless steel composite bolted joints with concrete-filled circular tubular columns

  • Wang, Jia;Uy, Brian;Li, Dongxu
    • Steel and Composite Structures
    • /
    • 제33권5호
    • /
    • pp.681-697
    • /
    • 2019
  • This paper numerically assesses the initial stiffness and moment capacity of stainless steel composite bolted joints with concrete-filled circular tubular (CFCT) columns. By comparing with existing design codes including EN 1993-1-8 and AS/NZS 2327, a modified component method was proposed to better predict the flexural performance of joints involving circular columns and curved endplates. The modification was verified with independent experimental results. A wide range of finite element models were then developed to investigate the elastic deformations of column face in bending which contribute to the corresponding stiffness coefficient. A new design formula defining the stiffness coefficient of circular column face in bending was proposed through regression analysis. Results suggest that a factor for the stiffness coefficient of endplate in bending should be reduced to 0.68, and more contribution of prying forces needs to be considered. The modified component method and proposed formula are able to estimate the structural behaviour with reasonable accuracy. They are expected to be incorporated into the current design provisions as supplementary for beam-to-CFCT column joints.

프리스트레스를 받는 중공형 콘크리트 충전 강관말뚝의 휨거동 해석 (Analysis on Flexural Behavior of Hollow Prestressed Concrete Filled Steel Tube Piles)

  • 정흥진;백규호
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.133-140
    • /
    • 2018
  • 본 연구에서는 중공형의 PHC말뚝과 강관말뚝을 합성한 중공형 콘크리트 충전 강관(HCFT)말뚝의 거동분석을 위한 수치해석 모델을 개발하였고 휨강도시험에 적용하여 모델의 타당성을 검증하였다. 개발된 비선형 유한요소해석 모델의 적정성을 파악하기 위해 실물 시험 결과와 비교하였고 이를 활용하여 HCFT말뚝에 적합한 접촉조건, PC강봉의 제원에 따른 효과, 콘크리트 두께에 따른 효과 등을 분석하였다. 소성응력분배법을 적용하여 HCFT말뚝의 휨강도 산정식을 제안하였고 시험 및 해석결과와 비교하여 활용성을 검증하였다. 본 연구의 결과는 HCFT말뚝의 최적설계 및 거동분석에 기초자료로 활용될 수 있을 것으로 판단된다.

세부목골조로 구성된 전통목골조 벽체 전단저항능력 (Shear Resistance Capacity Length of Traditional Wooden Frame's Wall divided into Small Frame)

  • 황종국;권양희;배동훈
    • 대한건축학회논문집:구조계
    • /
    • 제35권3호
    • /
    • pp.11-18
    • /
    • 2019
  • The purpose of this study was to estimate the resistance capacity of a traditional wooden house with shear walls made of wood panel. In order to achieve the purpose of the study, the load - displacement test was carried out and the resistance moment values of the shear walls were proposed. The shear walls were made by placing studs with a nominal dimension of $38mm{\times}89mm$ at intervals of 600 mm, and attaching 12 mm thick plywood with 8-d size pegs at intervals of 150 mm. The type of traditional building wall was classified and showed the moment resistance ability of each wall type. This value is expressed as a proportional value divided by the moment resisting capacity of the standard size shear walls not divided into the divided small frames. Although some frames have proportional values larger than 1.0 even though they have openings, most of them show values smaller than 1.0. Also, even without the openings, it showed a smaller value than 1, such as 0.84 and 0.67.

An investigation on the bearing capacity of steel girder-concrete abutment joints

  • Liang, Chen;Liu, Yuqing;Zhao, Changjun;Lei, Bo;Wu, Jieliang
    • Steel and Composite Structures
    • /
    • 제38권3호
    • /
    • pp.319-336
    • /
    • 2021
  • To achieve a rational detail of the girder-abutment joints in composite integral bridges, and validate the performance of the joints with perfobond connectors, this paper proposes two innovative types of I-shaped steel girder-concrete abutment joints with perfobond connectors intended for the most of bearing capacity and the convenience of concrete pouring. The major difference between the two joints is the presence of the top flange inside the abutments. Two scaled models were investigated with tests and finite element method, and the damage mechanism was revealed. Results show that the joints meet design requirements no matter the top flange exists or not. Compared to the joint without top flange, the initial stiffness of the one with top flange is higher by 7%, and the strength is higher by 50%. The moment decreases linearly in both types of the joints. At design loads, perfobond connectors take about 70% and 50% of the external moment with and without top flange respectively, while at ultimate loads, perfobond connectors take 53% and 26% of the external moment respectively. The ultimate strengths of the reduced sections are suggested to be taken as the bending strengths of the joints.

고력볼트 접합이음 철골보의 탄소성거동 (Elasto-Plastic Behavior of Steel Beams with High Strength Bolted Splices)

  • 최성모;김진호;노원경
    • 한국강구조학회 논문집
    • /
    • 제15권5호통권66호
    • /
    • pp.531-539
    • /
    • 2003
  • 노스리지 지진 발생시 구조체 손상이 발생했던 현장용접 모멘트골조와 달리 기둥-보 브라켓형식의 모멘트골조에는 지진의 영향을 조정하고 감소시키는 도구(tool)가 바로 보에 이음부(splice)이다. 지진발생 중에 보의 이음부는 연성의 퓨즈(fuse)로서 작용할 수 있고, 골조에 발생할 수 있는 흼모멘트를 포함한 힘의 크기를 제한할 수 있다. 국내에서는 모멘트 골조의 대부분이 기둥-보 브라켓 형식으로 이루어진다. 본 논문에서는 이음하지 않은 H형강보를 제작하여 단순가력 실험을 수행하였고, 고력볼트를 이용하여 전강도설계된 실물실험체와 플랜지볼트 열수를 각각 75%, 50% 및 0%로 줄여서 이음부를 제작한 H형강 보를 단순가력 실험을 수행하였다. 이들 실험을 통해 기둥-보 브라켓형식의 모멘트 골조에서 보의 이음부(Beam Splice)가 악보(Week Beam)의 임계위치(Critical Point)로서 작용할 수 있는 가능성을 타진하고자 하는 연구에 기초자료를 제공하는 것이 본 연구의 목적이다.

철골 모멘트 접합부에서 웨브의 모멘트 전달효율과 변형도 집중과의 관계에 관한 해석적 연구 (Analytical Study on Relationship Between Moment Transfer Efficiency of a Beam Web and Strain Concentration at Steel Moment Connections)

  • 김영주;오상훈;문태섭
    • 한국강구조학회 논문집
    • /
    • 제16권5호통권72호
    • /
    • pp.695-703
    • /
    • 2004
  • 본 논문에서는 4개의 철골 해석모델과 1개의 합성보 해석모델에 대한 단조가력 해석의 결과를 나타냈다. 철골 기둥-보 접합부에서 웨브의 모멘트 전달효율과 변형도 집중에 대해서 조사하였다. 해석결과 각형기둥을 가진 모델의 모멘트 전달효율은 각형기둥 플랜지의 면외변형 때문에 H-기둥을 가진 모델에 비해서 빈약했다. 스캘럽과 얇은 각형기둥 두께 및 슬래브도 또한 모멘트 전달효율의 저하를 가져오는 원인으로서, 이는 보-기둥 접합부의 파단을 초래할 가능성이 크다. 해석 결과는 실험결과와 비교하였다. 실험결과를 기초로 하면, 각형기둥 또는 슬래브가 있는 접합부의 변형능력은 빈약한 모멘트 전달효율과 이에 따른 플랜지의 변형도 집중에 의해 감소했다.