• 제목/요약/키워드: Molding Conditions

검색결과 556건 처리시간 0.03초

금형온도와 탈지조건이 사출성형에 의한 알루미나 부품 제조에 미치는 영향 (EFfect of Molding Temperature and Debinding Conditions on Fabrication of Alumina Component by Injection Molding)

  • 임형택;임대순
    • 한국세라믹학회지
    • /
    • 제32권5호
    • /
    • pp.559-566
    • /
    • 1995
  • Alumina powder was coated with stearic acid and then mixed with isotactic polypropylene, atactic polypropylene as binders at 15$0^{\circ}C$ for 2 hours. The mixture was then injection molded at various mold temperatures using injection molding machine to investigate the effect of the molding temperature and debinding parameters on the formation of the defects. The molded specimens were debinded in both air and nitrogen atmospheres. Wicking and solvent methods were also used to enhance debinding efficiency. The specimens were prefired at 120$0^{\circ}C$ and then sintered at 150$0^{\circ}C$ for 3 hours. Various defects were formed at mold temoperature of 3$0^{\circ}C$, 6$0^{\circ}C$ and 10$0^{\circ}C$ and any noticeable defect was not formed at 85$^{\circ}C$. The density of green body increased with mold temperature. Debinding in air atmosphere was more effective than in nitrogen atmosphere. Results also proved that wicking and solvent treatments helped minimize the number of defects.

  • PDF

In-Plane형 마이크로니들의 미세사출공정해석 ([ μ ]-Injection Molding Process Analysis for In-Plane Microneedle)

  • 강정진;허영무;정태성;이성희
    • 소성∙가공
    • /
    • 제14권6호
    • /
    • pp.491-495
    • /
    • 2005
  • Micro injection molding analysis for microneedle fabrication was performed in the present study. The dimensions of width and thickness for in-plane microneedle are $600{\mu}m$, $500{\mu}m$, respectively. A delivery system based on guidelines for traditional injection molding was designed for four-cavities molding system. To investigate the effects of processing conditions in the mirconeedle fabrication, injection molding analysis using commercial code was performed. It was shown that the total injection time has a significant effect on the fabrication of in-plane microneedles.

플라스틱 마이크로니들의 미세사출성형공정에 대한해석 (Analysis of Micro Injection Molding Process for Polymeric Microneedle Fabrication)

  • 이성희;강정진;허영무;정태성
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.55-59
    • /
    • 2005
  • Micro injection molding analysis for microneedle fabrication was performed in the present study. The dimensions of width and thickness for microneedle are 600um, 500um, respectively. A delivery system based on guidelines for traditional injection molding was designed for four-cavities molding system. To investigate the effects of processing conditions in the mirconeedle fabrication, injection molding analysis using commercial code was performed. It was shown that the total injection time has a significant effect on the fabrication of microneedles.

  • PDF

플라스틱 블로우몰딩 공정의 해석기반 디지털 트윈 구현 (Implementation of an simulation-based digital twin for the plastic blow molding process)

  • 홍석관
    • Design & Manufacturing
    • /
    • 제17권3호
    • /
    • pp.1-7
    • /
    • 2023
  • Blow molding is a manufacturing process in which thermoplastic preforms are preheated and then pneumatically expanded within a mold to produce hollow products of various shapes. The two-step process, a type of blow molding method, requires the output of multiple infrared lamps to be adjusted individually, so the process of finding initial conditions hinders productivity. In this study, digital twin technology was applied to solve this problem. A blow molding simulation technique was established and simulation-based metadata was generated. A response surface ROM (Reduced Order Model) was built using the generated metadata. Then, a dynamic ROM was constructed using the results of 3D heat transfer analysis. Through this, users can quickly check the product wall thickness uniformity according to changes in the control value of the heating lamp for products of various shapes, and at the same time, check the temperature distribution of the preform in real time.

유전알고리듬을 이용한 사출성형 공정조건 최적화 (Optimization of Processing Conditions in Injection Molding Using Genetic Algorithm)

  • 최원준;신효철;곽신웅
    • 대한기계학회논문집A
    • /
    • 제24권10호
    • /
    • pp.2543-2551
    • /
    • 2000
  • Precision injection molding is an important technology for improving productivity and lowering costs in the fields of medical components, lenses and electrical connectors. The quality of injection molded parts is affected by various processing conditions such as filling time and packing pressure profile. It is difficult to consider all the variables at the same time for prediction of the quality. In this study, the genetic algorithm was used to obtain the optimal processing conditions for minimizing the volumetric shrinkage of molded parts. For a higher convergence rate, the method of design of experiments was used to analyze the relationship between processing conditions and volumetric shrinkage of molded parts, which served as analysis tool for the capability of searching optimal processing conditions but also greatly reduces the calculation time by utilizing the information of searching area. As a practical example, compact disks that require micron-level precision were chosen for the study.

인공신경망을 활용한 최적 사출성형조건 예측에 관한 연구 (A Study on the Prediction of Optimized Injection Molding Condition using Artificial Neural Network (ANN))

  • 양동철;이준한;윤경환;김종선
    • 소성∙가공
    • /
    • 제29권4호
    • /
    • pp.218-228
    • /
    • 2020
  • The prediction of final mass and optimized process conditions of injection molded products using Artificial Neural Network (ANN) were demonstrated. The ANN was modeled with 10 input parameters and one output parameter (mass). The input parameters, i.e.; melt temperature, mold temperature, injection speed, packing pressure, packing time, cooling time, back pressure, plastification speed, V/P switchover, and suck back were selected. To generate training data for the ANN model, 77 experiments based on the combination of orthogonal sampling and random sampling were performed. The collected training data were normalized to eliminate scale differences between factors to improve the prediction performance of the ANN model. Grid search and random search method were used to find the optimized hyper-parameter of the ANN model. After the training of ANN model, optimized process conditions that satisfied the target mass of 41.14 g were predicted. The predicted process conditions were verified through actual injection molding experiments. Through the verification, it was found that the average deviation in the optimized conditions was 0.15±0.07 g. This value confirms that our proposed procedure can successfully predict the optimized process conditions for the target mass of injection molded products.

Monitor Backcover의 사이클 타임 단축에 관한 연구 (A Study on The Reduction of Cycle Time in Injection Molding Process of The Monitor Backcover)

  • 윤경환;김주권
    • 소성∙가공
    • /
    • 제14권4호
    • /
    • pp.368-374
    • /
    • 2005
  • In the present study we used a diagrammatic analysis of 6 sigma quality control and Taguchi method for injection molding of monitor back-cover, evaluated the influence on the cycle time with part design, mold design, molding process and standardization activity involving design and molding, adopted analysis of sensitivity and effective factors of the part design and molding process conditions for productivity, identified main design molding factors. The contributing factors for the final cycle time could be enumerated as follows; the thickness of hot spot, main nominal part thickness, coolant inlet temperature, melt temperature and cooling line layout, etc.. As a first step, all the critical factors of design process applied to the current monitor housing were investigated through 6 sigma process. Thereafter, the optimal and better critical factors found in the first step were applied to new product design to prove that our process was correct. The Moldflow was used for injection molding simulation, and Minitab software for the statistical analysis, respectively. Finally, the productivity of new design was increased about 33 percents for our specific case.

Monitor backcover의 사출시간 단축에 관한 연구 (A Study on The Reduction of Cycle Time in Injection Molding Process of The Monitor Backcover)

  • 김주권;김종선;윤경환
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2004년도 춘계학술대회 논문집
    • /
    • pp.269-272
    • /
    • 2004
  • The present study used a diagrammatic analysis of 6 sigma quality control and Taguchi method for injection molding process of monitor back-cover, evaluated the influence on the cycle time with part design, mold design, molding process and standardization activity involving design & molding, adopted analysis of sensitivity and effective factors of the part design and molding process conditions for productivity, identified main design molding factors, as critical ones influencing on the quality and productivity, of which is summarized as design guidance. The main contribution factors for cycle time can be sequentially enumerated as follows; hot spot, part thickness, coolant inlet temperature, melt temperature cooling line layout, etc.. As a first step critical factors of the design process of current monitor housing were investigated. And the optimal and better critical factors found in the first step were applied to a new product proving our process was correct. Moldflow software was used for injection molding simulation, and Minitab software for the statistical analysis. Finally, the productivity was increased by about 33 percents for our specific case.

  • PDF

고분자 패키징 용기 중량 절감을 위한 프리폼 설계에 관한 연구 (Study on Preform Design for Reducing Weight of PET Packaging Bottle)

  • 김정순
    • 한국산학기술학회논문지
    • /
    • 제11권1호
    • /
    • pp.1-6
    • /
    • 2010
  • 본 연구에서는 성형해석 및 실험적 방법을 통하여 페트 용기의 두께 편차를 최소화하기 위한 프리폼 최적화 설계를 수행하였다. 사출성형과정을 정확하게 묘사하기 위하여 3차원 모델을 이용하여 충진, 보압 및 냉각해석을 통하여 최적의 프리폼 설계변수를 설정하였으며, 이 결과를 이용하여 블로우 성형해석을 수행하였다. 성형해석결과를 평가하기 위한 사출성형 및 블로우 성형실험을 수행하였으며, 실험결과와 해석결과는 정성적으로 일치하는 것을 확인하였다. 이러한 실험결과 데이타를 설계에 반영함으로서 최적의 프리폼 형상을 얻을 수가 있었다.

이중 사출시 발행하는 Weld-line의 강도 연구 (A study on the weld-strength in two-shot molding)

  • 장민규;김창진;최해석;정영득
    • Design & Manufacturing
    • /
    • 제9권2호
    • /
    • pp.30-33
    • /
    • 2015
  • In injection molding, many kinds of defects have occurred because of a characteristic of plastics injection molding. Weld line is one of the defects is formed when separated melt fronts recombine together during the mold filling stage. That is one of problems in injection molding. Weld lines in the appearance of plastics parts can deteriorate visible quality. And most importantly, the local mechanical strength in the weld line area can be significantly weaker. It could be one of the most problems for structural applications. In this study, the mold available two-shot-molding of same polymers have been designed, and a series of experiment about tensile strength in weld line area has been conducted using Taguchi's design of experiment to optimize injection molding conditions decreasing of weld strength and find out a factors affected weld strength in two-shot- molding.

  • PDF