• 제목/요약/키워드: Molar region

검색결과 287건 처리시간 0.024초

Chronic maxillary sinusitis caused by root canal overfilling of Calcipex II

  • Kim, Jin-Woo;Cho, Kyung-Mo;Park, Se-Hee;Park, Soh-Ra;Lee, Sang-Shin;Lee, Suk-Keun
    • Restorative Dentistry and Endodontics
    • /
    • 제39권1호
    • /
    • pp.63-67
    • /
    • 2014
  • This is a case report of chronic maxillary sinusitis caused by root canal overfilling of Calcipex II (Techno-Dent). A 60 year-old male complained of dull pain in the right maxillary molar area after complicated endodontic treatment using Calcipex II paste and was finally diagnosed with a chronic maxillary sinusitis through a clinical and radiological observation. In the biopsy examination, the periapical granuloma contained a lot of dark and translucent Calcipex II granules which were not stained with hematoxylin and eosin. They were usually engulfed by macrophages but rarely resorbed, resulting in scattering and migrating into antral mucosa. Most of the Calcipex II granules were also accumulated in the cytoplasms of secretory columnar epithelial cells, and small amount of Calcipex II granules were gradually secreted into sinus lumen by exocytosis. However, chronic granulomatous inflammation occurred without the additional recruitment of polymorphonuclear leukocytes (PMNs) and lymphocytes, and many macrophages which engulfed the Calcipex II granules were finally destroyed in the processes of cellular apoptosis. It is presumed that Calcipex II granules are likely to have a causative role to induce the granulomatous foreign body inflammation in the periapical region, and subsequently to exacerbate the chronic maxillary sinusitis in this study.

Luminescence Properties of Ba3Si6O12N2:Eu2+ Green Phosphor

  • Luong, Van Duong;Doan, Dinh Phuong;Lee, Hong-Ro
    • 한국표면공학회지
    • /
    • 제48권5호
    • /
    • pp.211-217
    • /
    • 2015
  • To fabricate white LED having a high color rendering index value, red color phosphor mixed with the green color phosphor together in the blue chip, namely the blue chips with RG phosphors packaging is most favorable for high power white LEDs. In our previous papers, we reported on successful syntheses of $Sr_{2-}$ $Si_5N_8:Eu^{2+}$ and $CaAlSiN_3$ phosphors for red phosphor. In this work, for high power green phosphor, greenemitting ternary nitride $Ba_3Si_6O_{12}N_2:Eu^{2+}$ phosphor was synthesized in a high frequency induction furnace under $N_2$ gas atmosphere at temperatures up to $1400^{\circ}C$ using $EuF_3$ as a raw material for $Eu^{2+}$ dopant. The effects of molar ratio of component and experimental conditions on luminescence property of prepared phosphors have been investigated. The structure and luminescence properties of prepared $Ba_3Si_6O_{12}N_2:Eu^{2+}$ phosphors were investigated by XRD and photoluminescence spectroscopy. The excitation spectra of $Ba_3Si_6O_{12}N_2:Eu^{2+}$ phosphors indicated broad excitation wavelength range of 250 - 500 nm, namely from UV to blue region with distinct enhanced emission spectrum peaking at ${\approx}530nm$.

Cone-beam computed tomography characterization of the intraosseous vascular canal in the lateral wall of the maxillary antrum

  • Shetty, Shishir Ram;Al Bayatti, Saad Wahby;Marei, Hesham;Shetty, Raghavendra;Abdelmagyd, Hossam Abdelatty;Luke, Alexander Maniangat
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제47권1호
    • /
    • pp.34-39
    • /
    • 2021
  • Objectives: The purpose of the study was to assess the occurrence, location, and dimensions of the intraosseous vascular canal in the lateral wall of the maxillary antrum using cone-beam computed tomography (CBCT). Materials and Methods: In this retrospective study, we examined 400 CBCT scans from our archive of patients who had earlier reported to a dental teaching hospital in the United Arab Emirates. The prevalence, location, and dimensions of the lateral antral intraosseous canal (LAIC) in the maxillary antrum were evaluated by 2 examiners using standardised methods. A third examiner was consulted in cases of disagreement. Results: The prevalence of LAIC was 62.3% (249 maxillary antra) among the study population. The mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC in the posterior maxillary region was 19.83±3.12 mm. There was a significant difference (P=0.05) between the maxillary molar and premolar regions in mean distance from the most inferior point of the alveolar bone and the inferior border of the LAIC. There was no statistically significant difference in mean distance between the most inferior point of the alveolar bone and the inferior border of the LAIC between dentulous and edentulous areas (P=0.1). The G3-intrasinusal type canal less than 1mm in diameter was the most common type of LAIC. Conclusion: This study established the approximate location of the LAIC in a United Arab Emirates cohort, which will assist the oral surgeon in selecting the appropriate site for sinus lift procedures with reduced risk of surgical hemorrhage.

음향방출법을 이용한 치아/복합레진 수복재의 계면부 파괴해석 (Interfacial fracture analysis of human tooth/composite resin restoration using acoustic emission)

  • 구자욱;최낙삼
    • Composites Research
    • /
    • 제22권6호
    • /
    • pp.45-51
    • /
    • 2009
  • 치아의 와동에 수복된 치과용 복합레진을 광(LED) 조사를 통해 경화 수축시키면서 음향방출(acoustic emission, AE)법을 이용하여 와동 벽면과 복합레진 사이의 계면상태를 실시간 해석하였다. 복합레진의 중합 수축에 의해 AE 신호들이 검출되었는데 계면 접착 상태가 나쁜 경우, 경화 수축률이 큰 초기 1분 동안 많은 AE 사상들이 관측되었으며, 이들 AE는 주파수범위가 주로 100-200kHz인 돌발형이었다. 인간치아 재질의 시편에서 발생된 AE 사상수는 스테인리스 스틸 시편보다 적었으나, PMMA 시편보다는 많았고 접착제의 도포 상태가 양호할수록 검출되는 AE 사상수는 적었다. AE 파라미터의 특성은 복합레진과 링재 사이의 접착부에서 발생하는 인장형 균열전파 및 복합레진의 수축에 따른 링재의 압축거동과 관련되었으며, 음향방출법이 치아 수복물의 접착성에 대한 비파괴 검사법으로써 유효함을 알았다.

Skeletal and dentoalveolar effects of different types of microimplant-assisted rapid palatal expansion

  • Hyeong-Yoon Choi;Sang-Min Lee;Jin-Woo Lee;Dong-Hwa Chung;Mo-Hyeon Lee
    • 대한치과교정학회지
    • /
    • 제53권4호
    • /
    • pp.241-253
    • /
    • 2023
  • Objective: To evaluate the following null hypothesis: the skeletal and dentoalveolar expansion patterns in the coronal and axial planes are not different with two different types of microimplant-assisted rapid palatal expansion (MARPE) systems. Methods: Pretreatment (T0) and post-MARPE (T1) cone-beam computed tomography (CBCT) images of 32 patients (14 males and 18 females; mean age, 19.37) were analyzed. We compared two different MARPE systems. One MARPE system included the maxillary first premolars, maxillary first molars, and four microimplants as anchors (U46 type, n = 16), while the other included only the maxillary first molars and microimplants as anchors (U6 type, n = 16). Results: In the molar region of the U6 and U46 groups, the transverse expansion at the midnasal, basal, alveolar, and dental levels was 2.64, 3.52, 4.46, and 6.32 mm and 2.17, 2.56, 2.73, and 5.71 mm, respectively. A significant difference was observed in the posterior alveolar-level expansion (p = 0.036) and posterior basal-bone-level expansion (p = 0.043) between the groups, with greater posterior skeletal and alveolar expansion in the U6 group. Conclusions: Compared with the U46 group, the U6 group showed greater posterior expansion at the alveolar and basal-bone levels, with an almost parallel split. Both groups showed a pyramidal expansion pattern in the coronal view.

딥러닝을 이용한 구강 스캐너 이미지 내 치아 영역 실시간 검출 (Real-time Tooth Region Detection in Intraoral Scanner Images with Deep Learning)

  • 박나윤;김지훈;김태민;송경진;변유진;강민주;전경구;김재곤
    • 산업경영시스템학회지
    • /
    • 제46권3호
    • /
    • pp.1-6
    • /
    • 2023
  • In the realm of dental prosthesis fabrication, obtaining accurate impressions has historically been a challenging and inefficient process, often hindered by hygiene concerns and patient discomfort. Addressing these limitations, Company D recently introduced a cutting-edge solution by harnessing the potential of intraoral scan images to create 3D dental models. However, the complexity of these scan images, encompassing not only teeth and gums but also the palate, tongue, and other structures, posed a new set of challenges. In response, we propose a sophisticated real-time image segmentation algorithm that selectively extracts pertinent data, specifically focusing on teeth and gums, from oral scan images obtained through Company D's oral scanner for 3D model generation. A key challenge we tackled was the detection of the intricate molar regions, common in dental imaging, which we effectively addressed through intelligent data augmentation for enhanced training. By placing significant emphasis on both accuracy and speed, critical factors for real-time intraoral scanning, our proposed algorithm demonstrated exceptional performance, boasting an impressive accuracy rate of 0.91 and an unrivaled FPS of 92.4. Compared to existing algorithms, our solution exhibited superior outcomes when integrated into Company D's oral scanner. This algorithm is scheduled for deployment and commercialization within Company D's intraoral scanner.

Marginal fit of three different nanocomposite inlays fabricated with computer-aided design/computer-aided manufacturing (CAD/CAM) technology: a comparative study

  • Hyunsuk Choi;Jae-Young Jo;Min-Ho Hong
    • Journal of Yeungnam Medical Science
    • /
    • 제41권2호
    • /
    • pp.80-85
    • /
    • 2024
  • Background: This study aimed to compare and evaluate the marginal fit of nanocomposite computer-aided design/computer-aided manufacturing (CAD/CAM) inlays. Three types of nanocomposite CAD/CAM blocks (HASEM, VITA Enamic, and Lava Ultimate) were used as materials. Methods: Class II disto-occlusal inlay restorations were prepared on a typodont mandibular right first molar using diamond rotary instruments. The inlays were fabricated using CAD/CAM technology and evaluated using the silicone replica technique to measure marginal gaps at five locations on each inlay. The data were analyzed by two-way analysis of variance and Tukey post hoc tests (α=0.05). Results: There were no significant differences in the marginal gaps based on the type of nanocomposite CAD/CAM inlay used (p=0.209). However, there was a significant difference in the marginal gaps between the measurement regions. The gingival region consistently exhibited a larger marginal gap than the axial and occlusal regions (p<0.001). Conclusion: Within the limitations of this in vitro study, the measurement location significantly influenced the marginal fit of class II disto-occlusal inlay restorations. However, there were no significant differences in the marginal gaps among the different types of CAD/CAM blocks. Furthermore, the overall mean marginal fits of the class II disto-occlusal inlay restorations made with the three types of nanocomposite CAD/CAM blocks were within the clinically acceptable range.

구치부 단일 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 합병증의 발생률에 대한 후향적 연구 (Retrospective study on survival and complication rates of posterior single implant according to the implant diameters, lengths and position)

  • 홍수영;이선기;이진한;이재인
    • 대한치과보철학회지
    • /
    • 제61권2호
    • /
    • pp.101-112
    • /
    • 2023
  • 목적: 구치부 단일 임플란트에서 임플란트의 직경과 길이, 식립 위치에 따른 생존율 및 각각의 합병증의 발생률을 후향적으로 조사하는 것이다. 대상 및 방법: 본 연구는 2014년 2월부터 2018년 5월까지 원광대학교 대전치과병원 보철과에서 3명의 보철전문의에게 구치부 단일 치관으로 임플란트 보철 수복을 완료한 환자를 대상으로 하였다. 총 505명의 환자에서 697개의 임플란트를 추적 관찰하였다. 대상 환자의 전자 진료기록부와 방사선 사진을 통해 임플란트의 생존 여부 및 합병증을 기록하였으며 이에 영향을 미칠 수 있는 요인으로 고정체의 직경과 길이, 식립 위치 그리고 환자의 성별, 연령이 평가되었다. 결과: 생존율은 구치부 단일 임플란트의 3년 누적 생존율은 98.5%, 5년 누적 생존율은 94.4% 이었다. 5년 누적 생존율은 직경 4.0 mm 이하(89.5%)일 때보다 4.0 mm 초과(97.0%)일 때 더 높았고, 남성(92.4%)보다 여성(98.8%)에서 더 높았다. 이는 통계적으로 유의한 차이가 있었다 (P < .05). 구치부 단일 임플란트의 기계적 합병증은 20.1%, 생물학적 합병증은 4.7% 발생하였다. 합병증은 지대주 나사 풀림(7.5%), 보철물 탈락(6.3%), 인접면 접촉 상실(3.7%) 순으로 많이 발생하였다. 지대주 나사 풀림은 하악 대구치 부위(10.5%)에서 가장 많이 발생하였고 여성(5.1%)보다 남성(9.5%)에서, 65세 이상(5.1%)보다 65세 미만의 환자(9.4%)에서 더 많이 발생하였다. 이는 통계적으로 유의한 차이가 있었다 (P < .05). 결론: 구치부 단일 임플란트의 5년 누적 생존율은 고정체의 직경이 4.0 mm 이하일 때보다 4.0 mm 초과일 때, 남성보다 여성에서 더 높았다. 가장 많이 발생한 합병증인 지대주 나사 풀림은 하악 대구치 부위에서 가장 많이 발생하였고, 여성보다 남성에서, 65세 이상보다 65세 미만의 환자에서 더 많이 발생하였다. 이는 통계적으로 유의한 차이가 있었다.

중증환자를 위한 진공 구강 세정기에 대한 유동해석 (Flow Analysis of Vacuum Oral Cleaner Developed for Serious Patient)

  • 신현석;김남웅;김국원
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.121-126
    • /
    • 2018
  • 중환자실에 입원한 환자들의 구강위생은 매우 중요한 문제이다. 중환자들은 기본적으로 면역이 저하된 환자들로 각종 병원성 세균들에 의한 감염의 기회가 높기 때문이다. 구강문제는 감염의 1차 방어선인 구강이 감염의 우선적인 부위로 작용될 뿐 아니라 전신감염을 초래하기도 한다. 본 연구에서는 중증환자의 구강청소를 용이하게 하는 마우스 피스 형태의 새로운 진공 구강 세정기 설계에 관한 연구를 수행하였다. 이중 구조 방식의 세정기와 표준 치아 모델로써 3D CAD 모델링 및 유동해석 모델을 수립하고 압력 및 유동특성을 분석하였다. 세정기 내부의 압력은 거의 일정한 분포를 보였으나, 속력분포의 경우 치아 안쪽과 바깥쪽에서 큰 차이를 보였다. 치아 안쪽에서도 가운데 부분의 속도가 가장 높고 가운데에서 멀어질수록 속력이 감소하는 특성을 보였다. 세정기의 흡입관과 배출관을 바꾸어 해석한 결과 치아 바깥쪽 가운데 부분의 속도가 가장 높게 나타났다. 세정기의 효과를 높이기 위해서 흡입-배출을 교대로 바꾸는 교번식을 제안하고, 어금니 부위의 속력을 높이는 설계 보완이 요구된다.

Fenton Reaction을 이용한 Phenanthrene 오염 토양 처리에서 Acetate의 영향 (Influence of Acetate on the Removal of Phenanthrene from Contaminated Soil using Fenton Reaction)

  • 성요셉;박주양
    • 대한환경공학회지
    • /
    • 제31권5호
    • /
    • pp.352-357
    • /
    • 2009
  • 오염토양에 펜톤 반응을 적용함에 있어서 과산화수소의 빠른 소모로 과량의 과산화수소가 요구되어지는 것이 단점으로 지적되고 있다. 이에 본 연구에서는 대표적인 PAHs물질인 phenanthrene으로 오염된 토양 처리를 위해 철의 리간드로 acetate를 사용하여 과산화수소의 안정성 확보를 통하여 공정의 효율을 높이고자 하였다. Acetate는 철의 몰농도에 대비하여 0.5배에서 3배(2${\sim}$12 mM)까지 주입하였고, 과산화수소는 분해 효율에 미치는 영향을 배제하기 위해 낮은 농도인 0.7%를 주입하였다. Acetate가 주입되어 과산화수소의 잔류시간은 최대 50배 이상 증가하였으며, 과산화수소의 안정성이 확보됨에 따라 phenanthrene의 제거율도 70%까지 향상되었다. 반응 중에 철은 2가와 3가로 산화환원을 반복하였고 과산화수소가 모두 분해되는 시점부터 $HO_2^-$에 의해 2가철로 환원이 이루어졌다. 과산화수소의 영향으로 반응중의 pH는 산성영역을 나타냈으며, acetate가 8 mM 이상 주입되었을때 4${\sim}$5범위 내에 머무르는 것을 확인하였다. Fenton reaction에 의해 철의 리간드로 사용된 acetate 역시 분해가 이루어지는 것을 확인할 수 있었으며, phenanthrene의 비해 분해되는 시점이 느린 것으로 나타나 분해되어지는 경쟁관계에서 phenanthrene이 우세한 것으로 판단된다. 이상의 연구결과를 통해 오염 토양처리에 기존 Fenton reaction의 효율성과 경제성을 향상시킬 수 있는 가능성을 확인할 수 있었으며, 중성영역의 pH로 확장된 연구 등을 통해 좀 더 현실적인 공법으로 발전할 수 있으리라 판단된다.