• Title/Summary/Keyword: Molar region

Search Result 287, Processing Time 0.026 seconds

Acute Severe Periocular Swelling Caused by Periapical Abscess in a Dog (치근단 농양에 의해 발생된 급성 중증 안구주위부종 1례)

  • Park, Young-Woo;Park, Shin-Ae;Kim, Won-Tae;Kim, Se-Eun;Kim, Tae-Hyun;Ahn, Jae-Sang;Yoon, Jung-Hee;Seo, Kang-Moon
    • Journal of Veterinary Clinics
    • /
    • v.26 no.5
    • /
    • pp.483-485
    • /
    • 2009
  • A 10-year-old, intact female Yorkshire terrier was presented with right side facial swelling for 3 days and periocular swelling had progressed over the last 24 hours. On physical examination, periocular and infraorbital swelling were observed around right maxillary region. Severe ocular discharge and protrusion of the 3rd eyelid were observed. The patient was diagnosed as periapical abscess around the root of right upper first molar based on the skull radiography. Affected tooth was extracted using closed technique. Systemic corticosteroid and antibiotic were administrated and topical corticosteroid/antibiotic combination was applied to the right eye six times a day for 10 days. Ten days after tooth extraction, clinical signs were disappeared completely.

Clinical evaluation of the effects of free gingival and extracellular matrix grafts to increase the width of the keratinized tissue around dental implants (임플란트 주위 각화 조직 폭경의 증대를 위한 유리치은 이식술과 세포외 기질 이식술의 임상적 평가)

  • Jeong, Hwi-Seong;Kang, Jun-Ho;Chang, Yun-Young;Yun, Jeong-Ho
    • The Journal of the Korean dental association
    • /
    • v.55 no.1
    • /
    • pp.30-41
    • /
    • 2017
  • Inadequate keratinized mucosa around dental implants can lead to more plaque accumulation, tissue inflammation, marginal recession and attachment loss. We evaluated the effects of free gingival and extracellular matrix membrane grafts performed to increase the insufficient width of keratinized tissue around dental implants in the posterior mandible. A 47-year-old female patient presented with discomfort due to swelling of the lower right second premolar area. Due to severe destruction of alveolar bone, the tooth was extracted. After 3 months, a guided bone regeneration (GBR) procedure was performed and then a dental implant was placed 6 months later. During the second-stage implant surgery, free gingival grafting was performed to increase the width of the keratinized tissue. After 12 months, a clinical evaluation was performed. A 64-year-old female patient had a missing tooth area of bilateral lower molar region with narrow zone of keratinized gingiva and horizontal alveolar bone loss. Simultaneous implant placement and GBR were performed. Five months after the first-stage implant surgery, a gingival augmentation procedure was performed with an extracellular matrix membrane graft to improve the width of the keratinized tissue in the second-stage implant surgery. After 12 months, a clinical evaluation was performed. In these two clinical cases, 12 months of follow-up, revealed that the increased width of the keratinized tissue and the deepened oral vestibule was well maintained. A patient showed a good oral hygiene status. In conclusion, increased width of keratinized tissue around dental implants could improve oral hygiene and could have positive effects on the long-term stability and survival rate of dental implants. When planning a keratinized tissue augmentation procedure, clinicians should consider patient-reported outcomes.

  • PDF

Synthesis of Organic EL Materials with Cyano Group and Evaluation of Emission Characteristics in Organic EL Devices (시안기를 가진 유기 EL 물질들의 합성 및 유기 EL 소자에서의 발광특성평가)

  • Kim, Dong Uk
    • Journal of the Korean Chemical Society
    • /
    • v.43 no.3
    • /
    • pp.315-320
    • /
    • 1999
  • Novel electroluminescent materials, polymer material, PU-BCN and low molar mass material, D-BCN with the same chromophores were designed and synthesized. A molecular structure of chromophore was composed of bisstyrylbenzene derivative with cyano groups as electron injection and transport and phenylamine groups as hole injection and transport. Device structures with PU-BCN and D-BCN as an emission layer were fa-bricated, which were a single-layer device(SL), Indium-tin oxide(ITO)/emission layer/MgAg, and two kinds of double-layer devices which were composed of ITO/emission layer/oxadiazole derivative/MgAg as a DL-E device and ITO/triphenylamine derivative/emission layer/MgAg as a DL-H device. The two emission materials, PU-BCN and D-BCN with the same emission-chromophore were evaluated as having excellent performance of charge injection and transport and revealed almost the same emission characteristics in high current density. EL emission maximum peaks of two material were detected at about 640 nm wavelength of red emission region.

  • PDF

The incidence and morphology of maxillary sinus septa in dentate and edentulous maxillae: a cadaveric study with a brief review of the literature

  • Gandhi, Kusum Rajendra;Wabale, Rajendra Namdeo;Siddiqui, Abu Ubaida;Farooqui, Mujjebuddeen Samsudeen
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.41 no.1
    • /
    • pp.30-36
    • /
    • 2015
  • Objectives: The aim of this study is to determine the incidence, location, and orientation of maxillary sinus septa in formalin embalmed cadavers. Materials and Methods: The study was conducted on 210 cadaveric heads available in our department. After taking the mid-sagittal section the specimens were opened from the medial aspect and the sinus sinus septa, their anatomical plane, location and dimensions. Results: The mean linear distance between maxillary sinus floor and its anatomical ostium was $26.76{\pm}5.21mm$ and $26.91{\pm}4.96mm$ on right and left side, respectively. A total of 59 maxillary sinus septa (28.1%) were observed in 210 maxillary specimens. Septae were most common, 33 septa (55.9%), in the middle region (between first and second molar tooth) of the sinus cavity. The maxillary sinus membrane (Schneiderian membrane) adhered tightly to the maxillary sinus and over the septae. Significantly more maxillary sinus septa were observed in edentulous maxillae in comparison to the dentate upper jaw. Conclusion: Knowledge of location of maxillary sinus ostium is mandatory for the rhinologist for drainage of secretions in maxillary sinusitis. The morphological details of maxillary sinus septa, particularly their location and anatomical planes, will guide dentists in performance of safe implant surgeries. The maxillary antrum septa of category I and II may complicate the procedure of inversion of bone plate and elevation of sinus membrane during maxillary augmentation surgeries. The category III septa observed in the sagittal plane were embedded by one of the branches of the infraorbital nerve in it, and if accidentally cut will lead to infraorbital nerve palsy in maxillary sinus surgeries.

Platelet rich fibrin in the management of established dry socket

  • Chakravarthi, Srinivas
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.43 no.3
    • /
    • pp.160-165
    • /
    • 2017
  • Objectives: Dry socket may occur secondary to the removal of any tooth. However, most dry socket cases develop in the third molar region. Dry socket is multifactorial in nature and has been treated using various modalities with varying success rates. This study assessed the efficacy of platelet rich fibrin (PRF) in established dry socket. Materials and Methods: Ten patients of either sex aged from 41 to 64 years with established dry socket according to established criteria were treated using PRF. Evaluation was performed by observing the reduction of pain using visual analogue scale, analgesic tablet use over the follow-up period, and healing parameters. Results: Pain was reduced on the first day in all patients with decreased analgesic use. Pain was drastically reduced during follow-up on the first, second, third, and seventh days with a fall in pain score of 0 to 1 after the first day alone. The pain scores of all patients decreased to 1 by the first day except in one patient, and the scores decreased to 0 in all patients after 48 hours. Total analgesic intake ranged from 2 to 6 tablets (aceclofenac 100 mg per tablet) over the follow-up period of 7 days. Healing was satisfactory in all patients by the end of the seventh day. Conclusion: PRF showed early pain reduction in established dry socket with minimal analgesic intake. No patients had allergic reactions to PRF as it is derived from the patient's own blood. PRF showed good wound healing. Our study suggests that PRF should be considered as a treatment modality for established dry socket.

Electrochemical double layer capacitors with PEO and Sri Lankan natural graphite

  • Jayamaha, Bandara;Dissanayake, Malavi A.K.L.;Vignarooban, Kandasamy;Vidanapathirana, Kamal P.;Perera, Kumudu S.
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.219-226
    • /
    • 2017
  • Electrochemical double layer capacitors (EDLCs) have received a tremendous interest due to their suitability for diverse applications. They have been fabricated using different carbon based electrodes including activated carbons, single walled/multi walled carbon nano tubes. But, graphite which is one of the natural resources in Sri Lanka has not been given a considerable attention towards using for EDLCs though it is a famous carbon material. On the other hand, EDLCs are well reported with various liquid electrolytes which are associated with numerous drawbacks. Gel polymer electrolytes (GPE) are well known alternative for liquid electrolytes. In this paper, it is reported about an EDLC fabricated with a nano composite polyethylene oxide based GPE and two Sri Lankan graphite based electrodes. The composition of the GPE was [{(10PEO: $NaClO_4$) molar ratio}: 75wt.% PC] : 5 wt.% $TiO_2$. GPE was prepared using the solvent casting method. Two graphite electrodes were prepared by mixing 85% graphite and 15% polyvinylidenefluoride (PVdF) in acetone and casting n fluorine doped tin oxide glass plates. GPE film was sandwiched in between the two graphite electrodes. A non faradaic charge discharge mechanism was observed from the Cyclic Voltammetry study. GPE was stable in the potential windows from (-0.8 V-0.8 V) to (-1.5 V-1.5 V). By increasing the width of the potential window, single electrode specific capacity increased. Impedance plots confirmed the capacitive behavior at low frequency region. Galvanostatic charge discharge test yielded an average discharge capacity of $0.60Fg^{-1}$.

A CASE OF ODONTOGENIC MYXOMA RELATED TO BOTH IMPACTED CANINE TEETH IN THE MANDIBLE (소아에서 하악 양측 매복 견치와 연관된 치성 점액종)

  • Choi, Se-Hoon;Jeong, Jong-Cheol;Song, Min-Soek;Seo, Ji-Hoon;Kim, Soeng-Boem;Jun, Chang-Hun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.1
    • /
    • pp.64-67
    • /
    • 2003
  • Odontogenic myxoma is a rare tumor which occurs almost exclusively in the jaws, and seems to be of odontogenic origin. Clinically this tumor tends to appear in the second and third decades of life, and most of the lesions are located in the premolar - molar region. It is characterized grossly by mucoid or gelatinous gray-whitish tissue that replaces the cancellous bone and expands the cortex. It is invasive locally and has a high recurrence rate ranging from 10% to 33%. Radiographically, the appearance of this tumor is varied, but usually appears as a unilocular or multilocualr radioluscency of varying size. We experienced a rare case of odontogenic myxoma 12 years old patient related to mandibular bilateral impacted canines in the mandible, so we report this case with literature.

Efficient One-Pot Three-Component Synthesis of Monomethine Cyanine Dyes with Quinoline Nucleus and Their Spectral Properties

  • Fu, Y.L.;Zhang, B.R.;Wang, S.;Gao, X.X.;Wang, L.Y.
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.489-494
    • /
    • 2013
  • An improved method for the preparation of monomethine cyanine dyes with quinoline nucleus by one-pot three-component using 1-methyl-2-quinolinethione, quaternized 2- or 4-methylheterocyclic compounds and methyl p-toluenesulfonate as starting materials was described. Compared with the traditional methods, the new synthetic method reduced the reaction steps, shortened the reaction time, avoided the separation and purification of the intermediate and reduced cost. The dyes absorbed in the region 478.0-563.0 nm and had molar extinction coefficients of $1.3{\times}10^4-9.4 {\times}10^4L\;mol^{-1}\;cm^{-1}$. Their fluorescence maxima and Stokes shifts were in the range of 525.2-594.4 nm and 16.2-80.6 nm in different solvents, respectively. From the spectral properties of the dyes in different solvents, it could be found that the ${\lambda}_{max}$ of the dyes were shorter in protonic solvents, and showed hypsochromic shifts with the increase of polarity of the solvents.

3D Dimensional Finite Element Analysis of Contact Stress of Gold Screws in Implant Partial Denture (임플란트 국소의치 금나사의 3차원 유한요소법 접촉응력 분석)

  • Lee, Myung-Kon
    • Journal of Technologic Dentistry
    • /
    • v.35 no.4
    • /
    • pp.303-312
    • /
    • 2013
  • Purpose: In this research, non-linear three dimensional finite element models with contact elements were constructed. For the investigations of the distributions of contact stresses, 3 units fixed partial dentures model were studied, especially on the interface of the gold screw and cylinder, abutment screw. Methods: 3 types of models were constructed ; the basic fixed partial denture in molar region with 3 units and 3 implants, the intermediate pontic fixed partial denture model with 3 units and 2 implants, and the extension pontic fixed partial denture model with 3 units and 2 implants. For all types, the external loading due to chewing was simulated by applying $45^{\circ}$ linguo-buccal loading of 300 N to the medial crown. For the simulation of the clamping force which clinically occurs due to the torque, thermal expansion was provided to the cylinder as a preload. Results: Under 300 N concentrated loading to the medial crown, the maximum contact stress between abutment screw and gold screw was 86.85~175.86MPa without preload, while the maximum contact stress on the same area was 25.59~57.84MPa with preload. Conclusion: The preloading affected the outcomes of the finite element stress analysis. Reflecting the clinical conditions, the preloading conditions should be considered for other practical study utilizing FEA. For the study of the contact stresses and related motions, various conditions, such as frictional coefficient changes, gap between contact surfaces, were also varied and analyzed.

Effect of a 5% naproxen patch on reducing pain caused by separators prior to fixed orthodontic treatment

  • Eslamian, Ladan;Rad, Nazila Akbarian;Nobar, Behnam Rahbani;Mortazavi, Seyed Alireza
    • Journal of Dental Anesthesia and Pain Medicine
    • /
    • v.18 no.3
    • /
    • pp.151-159
    • /
    • 2018
  • Background: The pain involved in orthodontic treatments may involve inflammatory processes. This study evaluated the effect of using a naproxen patch for pain reduction in the separating stage of fixed orthodontic treatment. Methods: In this double-blind, randomized, controlled clinical trial of 35 orthodontic patients (age: 14-19 years) who had pain during separator placement, each patient randomly placed naproxen and placebo patches in the first permanent molar region, in opposite quadrants of the same jaw. Patches were replaced every 8 hours until 3 days after separator placement. Patients recorded their pain perception at 2, 6, and 24 hours, and on days 2 (6 PM), 3 (10 AM and 6 PM), and 7 (10 AM and 6 PM), using a visual analog scale. Mean pain scores were compared for the two patches, and effects of sex and age thereon determined. Results: Data from 29 patients (21 girls, eight boys) were analyzed. Mean pain values decreased over time for both patches (P < 0.001). Recorded pain did not differ significantly between the sexes (P = 0.059) or between those aged <16 and those ${\geq}16years$ (P = 0.106). Mean pain recorded with naproxen patches was statistically significantly less than that with placebo patches at all time points (P = 0.004). Conclusion: The naproxen patch was more efficient than the placebo patch for reducing pain at all time points. The highest pain score was recorded at 6 hours, and the least pain was recorded at the $7^{th}$ day after separator placement.