• Title/Summary/Keyword: Moire image

Search Result 70, Processing Time 0.023 seconds

Thermal Expansion Coefficient Measurement of STS430 by Laser Speckle Interferometry (레이저 스페클간섭법에 의한 STS430의 열팽창계수 측정)

  • 김경석;이항서;정현철;양승필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.29-33
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,000$^{\circ}C$. Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 800$^{\circ}C$. There needs to measure the data up to 800$^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000$^{\circ}C$. In previous studies related to thermal strain analysis, the quantitative results are not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,000$^{\circ}C$and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow 600$^{\circ}C$ however, there is some difference up to 600$^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 800$^{\circ}C$. The reason is the phase transformation of STS430 probably begins at 800$^{\circ}C$.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI (In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정)

  • 김경석;강기수;장호섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

A Case Report on the Ossification of the Posterior Longitudinal Ligament Treated by CHUNA Manual Therapy (추나요법으로 치료한 후방 종인대 골화증 1예)

  • Kim, Mi-Young;Park, Sung-Cheul;Kang, Sung-Ho;Song, Yung-Sun;Shin, Byung-Cheul
    • The Journal of Korea CHUNA Manual Medicine
    • /
    • v.3 no.1
    • /
    • pp.153-166
    • /
    • 2002
  • Objective : There is no case report on the ossification of the posterior longitudinal ligament(OPLL) treated by CHUNA manual therapy in oriental medicine. We experienced a patient(32-year-old female) with OPLL improved by CHUNA manual therapy in X-ray image and visual analogue scale(VAS), and we report it clinically. Methods : During the patient with OPLL was treated CHUNA manual therapy, acupuncture, and physical therapy, we examined cervical X-ray, CT and Moire topography and evaluated the patient's symptoms by VAS. And we observed whether the changes exist or not in X-ray and VAS. Results : VAS in symptoms was improved significantly(p<0.05), and the radiologic X-ray image in OPLL patient was improved. Conclusion : OPLL was generally treated conservative treatment and operation in severe case. But CHUNA manual therapy may be more effective in conservative treatment of OPLL, if more clinical studies and reaches are accomplished.

  • PDF

Estimation of Halftone Cell Information by Analyzing Distribution of Halftone Dots and Refining Location of Their Spectral Peaks (해프톤 도트 분포 분석 및 주파수 피크 위치 정제에 의한 해프톤 셀 정보 추정)

  • 한영미;김민환
    • Journal of Korea Multimedia Society
    • /
    • v.4 no.2
    • /
    • pp.116-129
    • /
    • 2001
  • To improve the performance of the inverse halftoning, smoothing masks should be designed optimally by using the accurate information of halftone cells. In this thesis, the method of energy minimization is so defined as to determine the exact information of halftone cell. A heuristic search method is proposed to obtain efficiently the parameters of halftone cells which determine the minimum energy. A halftone-peak modeling method with several functions is proposed and used to get initial values of the parameters. The dimension decomposition technique is also adopted to speed up the search process of energy minimization. Several experiments show that the proposed method extracts correct location of the seed pixel of the halftone cell and the extracted information of the halftone cell can be used to get more exactly smoothed color images. The proposed method can be applied to extract the texture patterns, to separate channel images of a scanned color halftone image, and to extract the moire area in an image.

  • PDF

Technology of Non-destructive Stress Measurement in Spot Welded Joint using ESPI Method (ESPI법에 의한 스폿 용접부의 비파괴적 응력측정 기술)

  • 김덕중;국정한;오세용;김봉중;유원일;김영호
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.1 no.1
    • /
    • pp.23-26
    • /
    • 2000
  • In spot welded joint. Electronic Speckle Pattern Interferometry(ESPI) method using the Model 95 Ar laser a video system and an image processor was applied to measure the stress Unlike traditional strain gauges or Moire method, ESPI method has no special surface preparation or attachments and can be measured in-plane displacement with non-contact and real time. In this experiment, specimens are loaded in parallel with a load cell. The specimens are made of the cold rolled steel sheet with 1mm thickness, are attached strain. gauges. This study Provides an example of how ESPI has been used to measure stress and strain inspecimen. The results measured by ESPI are compared with the data which was measured by strain gauge method under tensile testing.

  • PDF

Suppression of Moiré Fringes Using Hollow Glass Microspheres for LED Screen (중공 미소 유리구를 이용한 LED 스크린 모아레 억제)

  • Songeun Hong;Jeongpil Na;Mose Jung;Gieun Kim;Jongwoon Park
    • Journal of the Semiconductor & Display Technology
    • /
    • v.22 no.3
    • /
    • pp.28-35
    • /
    • 2023
  • Moiré patterns emerge due to the interference between the non-emission area of the LED screen and the grid line in an image sensor of a video recording device when taking a video in the presence of the LED screen. To reduce the moiré intensity, we have fabricated an anti-moiré filter using hollow glass microspheres (HGMs) by slot-die coating. The LED screen has a large non-emission area because of a large pitch (distance between LED chips), causing more severe moiré phenomenon, compared with a display panel having a very narrow black matrix (BM). It is shown that HGMs diffuse light in such a way that the periodicity of the screen is broken and thus the moiré intensity weakens. To quantitatively analyze its moiré suppression capability, we have calculated the spatial frequencies of the moiré fringes using fast Fourier transform. It is addressed that the moiré phenomenon is suppressed and thus the amplitude of each discrete spatial frequency term is reduced as the HGM concentration is increased. Using the filter with the HGM concentration of 9 wt%, the moiré fringes appeared depending sensitively on the distance between the LED screen and the camera are almost completely removed and the visibility of a nature image is enhanced at a sacrifice of luminance.

  • PDF

2D/3D Visual Optical Inspection System for Quad Chip (Quad Chip 외관 불량 검사를 위한 2D/3D 광학 시스템)

  • Han, Chang Ho;Lee, Sangjoon;Park, Chul-Geon;Lee, Ji Yeon;Ryu, Young-Kee;Ko, Kuk Won
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.17 no.1
    • /
    • pp.684-692
    • /
    • 2016
  • In the manufacturing process of the LQFP/TQFP (Low-profile Quad Flat Package/Thin Quad Flat Package), the requirement of a 3 dimensional inspection is increasing rapidly and a 3D inspection of the shape of a chip has become an important report of quality control. This study developed a 3 dimensional measurement system based on PMP (Phase Measuring Profilometry) for an inspection of the LQFP/TQFP chip and image processing algorithms. The defects of the LQFP/TQFP chip were classified according to the dimensions. The 2 dimensional optical system was designed by the dorm illumination to achieve constant light distribution, In the 3 dimensional optical system, PZT was used for moving 90 degree in phase. The problem of 2 ambiguity was solved from the measured moir? pattern using the ambiguity elimination algorithm that finds the point of ambiguity and refines the phase value. The proposed 3D measurement system was evaluated experimentally.

A Deblurring Algorithm Combined with Edge Directional Color Demosaicing for Reducing Interpolation Artifacts (컬러 보간 에러 감소를 위한 에지 방향성 컬러 보간 방법과 결합된 디블러링 알고리즘)

  • Yoo, Du Sic;Song, Ki Sun;Kang, Moon Gi
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.7
    • /
    • pp.205-215
    • /
    • 2013
  • In digital imaging system, Bayer pattern is widely used and the observed image is degraded by optical blur during image acquisition process. Generally, demosaicing and deblurring process are separately performed in order to convert a blurred Bayer image to a high resolution color image. However, the demosaicing process often generates visible artifacts such as zipper effect and Moire artifacts when performing interpolation across edge direction in Bayer pattern image. These artifacts are emphasized by the deblurring process. In order to solve this problem, this paper proposes a deblurring algorithm combined with edge directional color demosaicing method. The proposed method is consisted of interpolation step and region classification step. Interpolation and deblurring are simultaneously performed according to horizontal and vertical directions, respectively during the interpolation step. In the region classification step, characteristics of local regions are determined at each pixel position and the directionally obtained values are region adaptively fused. Also, the proposed method uses blur model based on wave optics and deblurring filter is calculated by using estimated characteristics of local regions. The simulation results show that the proposed deblurring algorithm prevents the boosting of artifacts and outperforms conventional approaches in both objective and subjective terms.

A Study on the Strain Analysis of Plane by Electronic Speckle Pattern Interferometry(ESPI) (전자처리스페클패턴간섭법에 의한 평판의 Strain 해석에 관한 연구)

  • Kim, Koung-Suk;Choi, Hyoung-Chul;Yang, Seung-Pil;Kim, Hyoung-Soo;Chung, Jae-Kang;Kim, Dong-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.14 no.2
    • /
    • pp.101-111
    • /
    • 1994
  • Electronic speckle pattern interferometry(ESPI) using a CW laser, a video system and an image processor were applied to the in-plane displacement measurements. Unlike traditional strain gauges or Moire method, ESPI method requires no special surface preparation or attachments and it can be measured in-plane displacement without any contact and real time. In this experiment, specimen was loaded in paralled with a loa cell. The specimen was plance to which strain gauges was attached. The study provides an example of how ESPI have been used to measure displacement and strain distribution in this specimen. The results measured by ESPI were compared with the data which were measured by strain gauge method in tensile testing.

  • PDF

Study on a moir$\acute{e}$ Artifact in the Use of Carbon Interspaced Antiscatter Grids for Digital Radiography (탄소 중간물질 그리드를 사용한 DR system에서의 moir$\acute{e}$ artifact에 관한 연구)

  • Lee, Sung-Ju;Cho, Hyo-Sung;Choi, Sung-Il;Cho, Hee-Moon;Oh, Ji-Eun;Lee, So-Young;Park, Yeon-Ok;Lee, Min-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.2 no.4
    • /
    • pp.5-9
    • /
    • 2008
  • Antiscatter grids are widely used in radiography to remove scattered X-rays and thus improve the image contrast. However, the use of grids makes moir$\acute{e}$ artifact in the digital image, and this can be a critical reason for a mistaken diagnosis. In this paper, we examined that moire artifacts are how to relate with grid frequency, pixel pitch and grid rotation angle. To experiment we prepared 6 grids having different line frequencies (4.0 to 8.5lines/mm) and tested with a DR imager having a $139{\mu}m{\times}139{\mu}m$ pixel size. In the result of this experiment, we could get data about moir$\acute{e}$ artifact that could be make solution to remove the line artifact for the successful use of the grid in digital radiography. The acquired data and theory through this experiment, are expected to make contribution to the elimination of moir$\acute{e}$ artifact in the DR system.

  • PDF