• Title/Summary/Keyword: Moire Measurement

Search Result 98, Processing Time 0.026 seconds

A Vision-based Pipe Support Displacement Measurement Method Using Moire Patterns (모아레 현상을 이용한 영상기반 파이프 서포트 변위측정 방법)

  • Park, Junbeom;Park, Semi;Kim, Jaehyeon;Kim, Jungyeol
    • Korean Journal of Construction Engineering and Management
    • /
    • v.23 no.1
    • /
    • pp.37-45
    • /
    • 2022
  • It is very important to measure the displacement of a structure to evaluate the safety of the structure. This study shows a methodology to measure the displacement to determine the stability of a structure when it is damaged by loads. The methodology used Moiré's phenomenon and was verified through experiments. The experiments utilized pipes to simulate the pipe supports in the construction site and measured the vertical displacement of the Moiré interference patterns according to the horizontal displacement of the pipes. Experiments confirmed that the linear relationship between horizontal displacement of pipes and vertical displacement of Moiré patterns and derive a relational expression. In conclusion, the methodology presented in this work allows us to simultaneously measure a number of vertical members' displacements regardless of distance and determine the safety of the structure.

Three-dimensional Machine Vision System based on moire Interferometry for the Ball Shape Inspection of Micro BGA Packages (마이크로 BGA 패키지의 볼 형상 시각검사를 위한 모아레 간섭계 기반 3차원 머신 비젼 시스템)

  • Kim, Min-Young
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.19 no.1
    • /
    • pp.81-87
    • /
    • 2012
  • This paper focuses on three-dimensional measurement system of micro balls on micro Ball-Grid-Array(BGA) packages in-line. Most of visual inspection system still suffers from sophisticate reflection characteristics of micro balls. For accurate shape measurement of them, a specially designed visual sensor system is proposed under the sensing principle of phase shifting moire interferometry. The system consists of a pattern projection system with four projection subsystems and an imaging system. In the projection system, four subsystems have spatially different projection directions to make target objects experience the pattern illuminations with different incident directions. For the phase shifting, each grating pattern of subsystem is regularly moved by PZT actuator. To remove specular noise and shadow area of BGA balls efficiently, a compact multiple-pattern projection and imaging system is implemented and tested. Especially, a sensor fusion algorithm to integrate four information sets, acquired from multiple projections, into one is proposed with the basis of Bayesian sensor fusion theory. To see how the proposed system works, a series of experiments is performed and the results are analyzed in detail.

2중파장 영사식 무아레의 N-Buckets 알고리즘 오차비교에 관한 실험적 연구

  • 유원재;박낙규;강영준
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.05a
    • /
    • pp.181-181
    • /
    • 2004
  • 3 차원 형상측정기술(3-D Profile Measurement Method)은 가공품의 치수검사 및 형상측정 등의 공학분야뿐만 아니라 최근에는 의류산업 및 의학산업은 물론 오락산업의 가상현실 구현 등 여러 분야로 점차 사용이 확대되고 있다. 이러한 요구를 만족시킬 수 있는 광학을 바탕으로 한 비접촉 3 차원 형상측정방법(Non-contacting 3-D Profile Measuring Method)은 고속, 고정밀도 측정이 가능하기 때문에 활발히 연구되고 있다. 광학을 이용한 대표적인 3 차원 비접촉 측정방법의 하나인 영사식 무아레는 그림자식 무아레의 단점인 격자의 크기가 측정물체보다 커야 한다는 점과 측정물체와 격자사이의 거리 제한 문제를 해결하였으며, 위상이동법을 사용함으로서, 무아레 무늬 형태의 영향을 받지 않고 측정이 가능해졌다.(중략)

  • PDF

Measurement of Breast Volume and the Area of Breast Base Using 3D Measurement System (3차원 측정시스템을 이용한 유방부피 및 유저면적의 측정)

  • 이현영;이옥경;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.27 no.2
    • /
    • pp.270-276
    • /
    • 2003
  • Methodology was suggested to analyze breast volume, base area of breast bulk. and surface area of breast using the 3D measurement system. Thirty-seven middle-aged (30s-40s) women wearing 80A brassiere were participated in this study. Image of the upper body was captured by Phase-shifting moire. The posture of the subject was adjusted to get the full image of the right breast. Rapidform 2001 was used for the analysis of the images. The mean breast volume was 547.0㎤ and mean base area of breast bulk was 235. I$\textrm{cm}^2$ It was also found that the volume(r=0.169) and surface area of breast(r=10.242) were loosely correlated with the circumference difference between top and under breast. Therefore, it is noted that current selection criterion of cup size based on the difference in the two kinds of breast circumference is inadequate. The result of this study is expected to contribute to the design of ergonomic brassiere as well as surgical operations in the medical field.

Thermal Expansion Coefficient Measurement of STS430 by Laser Speckle Interferometry (레이저 스페클간섭법에 의한 STS430의 열팽창계수 측정)

  • 김경석;이항서;정현철;양승필
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.29-33
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,000$^{\circ}C$. Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 800$^{\circ}C$. There needs to measure the data up to 800$^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000$^{\circ}C$. In previous studies related to thermal strain analysis, the quantitative results are not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,000$^{\circ}C$and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow 600$^{\circ}C$ however, there is some difference up to 600$^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 800$^{\circ}C$. The reason is the phase transformation of STS430 probably begins at 800$^{\circ}C$.

  • PDF

Thermal Expansion Coefficient Measurement of STS430 at High Temperature by In-plane ESPI (In-plane ESPI를 이용한 고온에서 STS430의 열팽창계수 측정)

  • 김경석;강기수;장호섭
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.69-74
    • /
    • 2004
  • This paper presents ESPI system for the measurement of thermal expansion coefficient of STS430 up to 1,00$0^{\circ}C$ . Existing methods, strain gauge and moire have the limitation of contact to object and do not supply the coefficient up to 80$0^{\circ}C$ . There needs to measure the data up to 80$0^{\circ}C$, because heat resistant materials have high melting temperature up to 1,000'E In previous studies related to thermal strain analysis, the quantitative results have not reported by ESPI at high temperature, yet. In-plane ESPI and vacuum chamber for the reduction of air turbulence and oxidation are designed for the measurement of the coefficient up to 1,00$0^{\circ}C$ and speckle correlation fringe pattern images are processed by commercial image filtering tool-smoothing, thinning and enhancement- to obtain quantitative results, which is compared with references data. The comparison shows two data are agreed within 4.1% blow $600^{\circ}C$ however, there is some difference up to $600^{\circ}C$. Also, the incremental ratio of the coefficient is changed up to 80$0^{\circ}C$ . The reason is the phase transformation of STS430 probably begins at 80$0^{\circ}C$

Collimation testing of a white light beam and measurement of chromatic aberration of a lens by using vernier Moire fringe patterns (버니어 무아레 무늬를 이용한 백색광의 시준 검사 및 렌즈의 색수차 측정)

  • 송종섭
    • Korean Journal of Optics and Photonics
    • /
    • v.11 no.4
    • /
    • pp.232-238
    • /
    • 2000
  • The new collimation testing technique of a white light beam using vernier Moire fringes of two line or circular gratings with different pitches is presented. We can visually measure the defocusing ($\Deltaf$), the divergence angle ($\theta$), and the longitudinal chromatic aberration $(L_{ch})$ of a collimating lens by using the technique. For example, we obtained $\Deltaf$= 21.9 mm and $\theta=0.0038^{\circ}$ for a testing lens with the focallengthf = 120.0 mm and F-number of F/2.4. The longitudinal chromatic aberration $L_{ch}$ of another testing lens withf = 65.0 mm, F/1.6, and the Abbe number V = 64.1 for the incident wavelengths of $\lambda_1=480 nm and \lambda_2=640 nm$ is easily measured by same technique. It is found that the measured value $L_{ch}=1.59mm(\pm0.01mm)$ is well agreed with $L_{ch}=1.58mm(\pm0.01mm)$ obtained by the autofocus method.

  • PDF

Moire Interferometry Measurement and Numerical Analysis for Hygroscopic Swelling of Al-Polymer Joint (Al-Polymer 접합체의 흡습팽창에 대한 모아레 간섭 측정 및 수치해석)

  • Kim, Kibum;Kim, Yong-Yun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3442-3447
    • /
    • 2014
  • A simple method to evaluate the hygroscopic characteristics of polymer of microelectronic plastic package is suggested. To evaluate the characteristics, specimens were prepared, and the internally absorbed moisture masses were measured as a function of the absorbing time and calculated numerically. The hygroscopic pressure ratio was calculated by heat transfer analysis supported by commercial FEM code because the hygroscopic diffusion equation has the same form as the heat transfer equation. The moisture masses were then summed by the self developed code. The nonconductive polymers had quite different characteristics for the different lots, even though they were the same products. The absorbed moisture mass variations were calculated for several different characteristics, and the optimal curve of the mass variation close to experimental data was selected, whose solubility and diffusivity were affected by the hygroscopic characteristics of the material. The method can be useful in the industrial fields to quickly characterize the polymer material of the semiconductor package because the fast correspondence is normally required in industry. The weight changes in the aluminum-nonconductive-polymer joint due to moisture absorption were measured. The deformed system was also measured using the Moire Interferometry system and compared with the results of finite element analysis.

A Robust Method for Automatic Generation of Moire Reference Phase from Noisy Image (노이즈 영상으로부터 모아레 기준 위상의 강인 자동 생성 방법)

  • Kim, Kuk-Won;Kim, Min-Young
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.5
    • /
    • pp.909-916
    • /
    • 2009
  • This paper presents the automatic vision algorithm to generate and calibrate reference phase plane to improve the accuracy of 3D measuring machine of using phase shifting projection moire method, which is not traditional N-bucket method, but is based on direct image processing method to the pattern projection image. Generally, to acquire accurate reference phase plane, the calibration specimen with well treated surface is needed, and detailed calibration method should be performed. For the cost reduction of specimen manufacturing and the calibration time reduction, on the specimen, not specially designed, with general accuracy level, an efficient calibration procedure for the reference phase generation is proposed. The proposed vision algorithm is developed to extract the line center points of the projected line pattern from acquired images, derive the line feature information consisting of its slope and intercept by using sampled feature points, and finally generate the related reference phase between line pairs. Experimental results show that the proposed method make reference phase plane with a good accuracy under noisy environment and the proposed algorithm can reduce the total cost to make high accurate calibration specimen, also increase the accuracy of reference phase plane, and reduce the complex calibration procedure to move grid via N-bucket algorithm precisely.

Development of Dress Forms for the Middle-high School Girls Based on their Lower Body Types (여중생의 하반신 체형분류에 따른 유형별 인대개발)

  • 임지영;김혜경
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.23 no.6
    • /
    • pp.886-897
    • /
    • 1999
  • Fitness of clothes becomes a major concern in apparel industry. But girls had difficulties to buy ready-made clothes of good fit. To solve this problem it is necessary to classify girls' lower body Into several kinds of somatotypes and to develop dress form. The purposes of this study was to classify lower body types of middle-high school an provide the dress forms based on the analysis of their lower body types. The subjects for anthropometric measurement were 402 middle-high school girls of 13 to 15 year-old. The result of factor analysis indicated that 5 factors were extracted from anthropometric measurments through factor analysis and those factors comprise 71% of total variance. 4 clusters were categorized using 5 factor scores by cluster analysis 4 lower body dress forms for middle-high school girls were made of gypsum mould. By the analysis of more photograph three dimensional characteristics of somatotype and overlapped cross-section diagrams were analyzed.

  • PDF