• Title/Summary/Keyword: Moire Measurement

Search Result 98, Processing Time 0.025 seconds

A Study on the Phase Measuring Profilometry with Parallel-optical-axes (평행 광축에서의 위상측정 형상측정법에 관한 연구)

  • 정경민;박윤창;박경근
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.6
    • /
    • pp.210-217
    • /
    • 2000
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and it's high sensitivity. Especially when projecting a grid pattern over the object, the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, the projection moire are compared with the PMP mathematically, and it is shown that PMP can generate moire image with simple mathematical computations. Experimental works are also carried out showing the same results. It is shown that using a single gird pattern, moire image can be obtained directly without any mathematical operation when some conditions are satisfied.

  • PDF

The Study of Pain-Increased Factors on Cervical and Shoulder Pain by 3 Dimensional Moire Scanner (3차원 체형 측정기를 통한 경.견부 통증요인 분석)

  • Yang, Hoe-Song;Heo, Ja-Eun;Kim, Bo-Young;Seo, Dong-Yong;An, Chang-Heon;Yang, Hun-Kyung;Jeong, Chan-Ju;Lee, Hyoung-Soo
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.27-34
    • /
    • 2005
  • The purpose of this study is to find out factors(shoulder level, acromion-occipital length, spine alignment, spine-scapula inferior angle length) of pain of neck & shoulder by 3 Dimensional Moire Scanner. 50 female student s aged 20 to 25 years old participated who lived in Sun-cheon si Jeonnam. They were examined with three measurement methods(Visual Analogue Scale : VAS, Algometer, 3 Dimensional Moire Scanner(IBS-2000). According to the results of multiple regression analysis. 1) There was a significant difference with shoulder level and spine-scapula inferior angle based on VAS. 2) There was a significant difference with shoulder level based of Algometer measurement value in Rhomboid muscles.

  • PDF

Fundamental Morphological Consideration for the 3-D Shape Analysis of the Middle-aged Women's Breast (중년 여성의 3차원 유방 형상 분석을 위한 방법론 연구)

  • 이현영;홍경희
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.26 no.5
    • /
    • pp.703-714
    • /
    • 2002
  • This paper proposed the basic consideration for the reliable 3-D measurement and analysis of middle-aged women's breast using 3-D phase-shifting moire topography. The surface borderline of the breast based on the anatomical structure on the skin was suggested. Various breast dimensions that can be measured using 3-D measurement system and their measuring methods were discussed. Tips for the measurement of sagged breast were also proposed. It is expected that these basic considerations contribute to draw attention to the reliable measurement of women's breast and provide a kind of tools for the standardization of 3-D shape measurement of breast.

Application of DMD for Phase Shifting in Moire Topology (DMD를 이용한 위상천이 모아레 3차원 형상 측정)

  • Jeong, Kyung-Seok;Jung, Yong-Sang
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.6
    • /
    • pp.2457-2462
    • /
    • 2011
  • The need for rapid and accurate measurement of 3-dimensional objects is increasing due to the paradigmatic shift in manufacturing from mass production to small batch production. A three dimensional measurement technique which can provide the dimensional information of the object manufactured or to be manufactured has been developed. This method is based on phase shifting moire topology. Digital-Micromirror-Device (DMD) has been used in generating phase shifting moire fringes. And the mechanically moving optical components used for phase shifting, which might result in measurement errors, have been replaced by the DMD. Inherent $2\pi$-ambiguity problem, occurring in the calculation of phase from the light intensity distribution due to the nature of arctangent function, has been overcome by adapting the phase unwrapping method. The advantage of this technique is the easy change of the range and the resolution of the measurement by simply changing the computer generated grid pattern with the appropriate combination of projection lens of various focal length.

East 3-Dimensional Shape Reconstruction Using Phase-Shifting Grating Projection Moire Method (위상천이 영사식 모아레법을 이용한 고속 3차원 형상복원)

  • 최이배;구본기;정연구
    • Proceedings of the Korean Society for Emotion and Sensibility Conference
    • /
    • 1998.11a
    • /
    • pp.111-115
    • /
    • 1998
  • A phase-shifting projection moire method particularly intended for high-speed three-dimensional shape reconstruction of diffuse objects is presented. Emphasis is on realization of phase-shifting fringe analysis in projection moire topography using a set of line grating pairs designed to provide different phase shifts in sequence. Further a time-integral fringe capturing scheme is devised to remove undesirable high frequency original grating patterns in real-time without time-consuming software image processing. Finally the performances of the proposed method are discussed with measurement results.

  • PDF

A Study on the measurement of 3-D Object with Single Grating Shiftings (단일격자 이송을 이용한 영사식 3차원 물체 형상 측정에 관한 연구)

  • 박윤창;정경민
    • Proceedings of the Korean Society of Machine Tool Engineers Conference
    • /
    • 1999.05a
    • /
    • pp.187-192
    • /
    • 1999
  • Noncontact measuring methodology of 3-dimensional profile using CCD camera are very attractive because of it's high measuring speed and its's high sensitivity. Especially when projecting a grid pattern over the object, the captured image have 3 dimensional information of the object. Projection moire extract 3-D information with another grid pattern in front of CCD camera. However phase measuring profilometry(PMP) obtain similar results without additional grid pattern. In this paper, the projection moire are compared with the PMP mathematically, and it is shown that PMP can generate moire image with simple mathematical computations. Experimental works are also carried out showing the same results. It is shown that using a single gird pattern, moire image can be obtained directly without any mathematical operation when some conditions are satisfied.

  • PDF