• 제목/요약/키워드: Modulated arc (mARC) technique

검색결과 8건 처리시간 0.038초

Dosimetric comparison between modulated arc therapy and static intensity modulated radiotherapy in thoracic esophageal cancer: a single institutional experience

  • Choi, Kyu Hye;Kim, Jina;Lee, Sea-Won;Kang, Young-nam;Jang, HongSeok
    • Radiation Oncology Journal
    • /
    • 제36권1호
    • /
    • pp.63-70
    • /
    • 2018
  • Purpose: The objective of this study was to compare dosimetric characteristics of three-dimensional conformal radiotherapy (3D-CRT) and two types of intensity-modulated radiotherapy (IMRT) which are step-and-shoot intensity modulated radiotherapy (s-IMRT) and modulated arc therapy (mARC) for thoracic esophageal cancer and analyze whether IMRT could reduce organ-at-risk (OAR) dose. Materials and Methods: We performed 3D-CRT, s-IMRT, and mARC planning for ten patients with thoracic esophageal cancer. The dose-volume histogram for each plan was extracted and the mean dose and clinically significant parameters were analyzed. Results: Analysis of target coverage showed that the conformity index (CI) and conformation number (CN) in mARC were superior to the other two plans (CI, p = 0.050; CN, p = 0.042). For the comparison of OAR, lung V5 was lowest in s-IMRT, followed by 3D-CRT, and mARC (p = 0.033). s-IMRT and mARC had lower values than 3D-CRT for heart $V_{30}$ (p = 0.039), $V_{40}$ (p = 0.040), and $V_{50}$ (p = 0.032). Conclusion: Effective conservation of the lung and heart in thoracic esophageal cancer could be expected when using s-IMRT. The mARC was lower in lung $V_{10}$, $V_{20}$, and $V_{30}$ than in 3D-CRT, but could not be proven superior in lung $V_5$. In conclusion, low-dose exposure to the lung and heart were expected to be lower in s-IMRT, reducing complications such as radiation pneumonitis or heart-related toxicities.

Deep inspiration breath-hold (DIBH) 적용한 림프절이 포함된 왼편 유방암의 방사선 치료계획에 따른 주변 장기 선량 평가

  • 정다이;강효석;최병준;박상준;이건호;이두상;안민우;전명수
    • 대한방사선치료학회지
    • /
    • 제29권1호
    • /
    • pp.27-35
    • /
    • 2017
  • 목 적: 왼편 유방암 환자의 경우 오른편 유방암 환자보다 심장과 폐 등 정상장기에 불필요한 선량이 일부 조사됨에 따라 부작용이 우려되고 있다. 이를 줄이기 위해 DIBH기법을 시행하고 있다. Conventional Radiation Therapy, Intensity Modulated Radiation Therapy, Volumetric Modulated Arc Therapy의 치료계획 방법에 따라 쇄골상 림프절과 내유 림프절을 포함한 왼편 유방암의 경우 주변 장기의 선량 값을 비교 평가하고자 한다. 대상 및 방법: 왼편 유방암 환자 중 쇄골상 림프절과 내유 림프절을 포함한 환자 8명을 대상으로 Free Breathing과 Deep inspiration breath-hold 기법을 적용하여 각각 CT-Simulation을 시행한다. 획득한 영상을 기반으로 체표윤곽을 그려 95 %$D_{max}$<110 %이 되도록 Conventional Radiation Therapy, Intensity Modulated Radiation Therapy, Volumetric Modulated Arc Therapy방법으로 계획하였다. Conventional Radiation Therapy는 쇄골상 림프절에 1문조사, 유방 부분에 접선 2문조사로 Field in Field 기법을 사용하였다. Intensity Modulated Radiation Therapy는 7개의 조사면으로 구성하였다. Volumetric Modulated Arc Therapy은 회전반경을 $290^{\circ}{\sim}179^{\circ}$으로 한 2 ARC를 이용하여 계획을 수행하였다. Eclipse의 선량체적용적을 참고하여 주변 정상 장기 선량을 분석하였다. 결 과: Deep inspiration breath-hold기법을 적용함으로 심장과 흉벽 사이의 간격은 평균 $1.6{\pm}0.6cm$ 증가하였다. 폐의 평균 선량은 $19.2{\pm}1.0Gy$로 Intensity Modulated Radiation Therapy에서 가장 작은 값이 나타났다. 심장의 $V_{30}(%)$$2.0{\pm}1.9$로 Intensity Modulated Radiation Therapy에서 가장 작은 값이었다. 좌전하행 관상동맥에서는 평균 선량이 $25.4{\pm}5.4Gy$로 Intensity Modulated Radiation Therapy에서 가장 작은 값으로 나타났다. 반대편 유방의 최대선량 값은 Intensity Modulated Radiation Therapy일 때 $29.7{\pm}4.3Gy$로 가장 작은 값으로 나타났다. 결 론: 주변 정상장기 선량의 값을 비교해 보았을 때, Intensity Modulated Radiation Therapy와 Volumetric Modulated Arc Therapy은 치료에 적용할 수 있는 값으로 나타났다. 이 중 Intensity Modulated Radiation Therapy가 적합한 치료계획 방법으로 사료된다.

  • PDF

Adjuvant Radiotherapy after Breast Conserving Treatment for Breast Cancer:A Dosimetric Comparison between Volumetric Modulated Arc Therapy and Intensity Modulated Radiotherapy

  • Liu, Zhe-Ming;Ge, Xiao-Lin;Chen, Jia-Yan;Wang, Pei-Pei;Zhang, Chi;Yang, Xi;Zhu, Hong-Cheng;Liu, Jia;Qin, Qin;Xu, Li-Ping;Lu, Jing;Zhan, Liang-Liang;Cheng, Hong-Yan;Sun, Xin-Chen
    • Asian Pacific Journal of Cancer Prevention
    • /
    • 제16권8호
    • /
    • pp.3257-3265
    • /
    • 2015
  • Background: Radiotherapy is an important treatment of choice for breast cancer patients after breast-conserving surgery, and we compare the feasibility of using dual arc volumetric modulated arc therapy (VMAT2), single arc volumetric modulated arc therapy (VMAT1) and Multi-beam Intensity Modulated Radiotherapy (M-IMRT) on patients after breast-conserving surgery. Materials and Methods: Thirty patients with breast cancer (half right-sided and half left-sided) treated by conservative lumpectomy and requiring whole breast radiotherapy with tumor bed boost were planned with three different radiotherapy techniques: 1) VMAT1; 2) VMAT2; 3) M-IMRT. The distributions for the planning target volume (PTV) and organs at risk (OARs) were compared. Dosimetries for all the techniques were compared. Results: All three techniques satisfied the dose constraint well. VMAT2 showed no obvious difference in the homogeneity index (HI) and conformity index (CI) of the PTV with respect to M-IMRT and VMAT1. VMAT2 clearly improved the treatment efficiency and can also decrease the mean dose and V5Gy of the contralateral lung. The mean dose and maximum dose of the spinal cord and contralateral breast were lower for VMAT2 than the other two techniques. The very low dose distribution (V1Gy) of the contralateral breast also showed great reduction in VMAT2 compared with the other two techniques. For the ipsilateral lung of right-sided breast cancer, the mean dose was decreased significantly in VMAT2 compared with VMAT1 and M-IMRT. The V20Gy and V30Gy of the ipsilateral lung of the left-sided breast cancer for VMAT2 showed obvious reduction compared with the other two techniques. The heart statistics of VMAT2 also decreased considerably compared to VMAT1 and M-IMRT. Conclusions: Compared to the other two techniques, the dual arc volumetric modulated arc therapy technique reduced radiation dose exposure to the organs at risk and maintained a reasonable target dose distribution.

Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study

  • Mani, Karthick Raj;Upadhayay, Sagar;Das, K.J. Maria
    • Radiation Oncology Journal
    • /
    • 제35권1호
    • /
    • pp.90-100
    • /
    • 2017
  • Purpose: To Study the dosimetric advantage of the Jaw tracking technique in intensity-modulated radiotherapy (IMRT) and volumetric-modulated arc therapy (VMAT) for Head and Neck Cancers. Materials and Methods: We retrospectively selected 10 previously treated head and neck cancer patients stage (T1/T2, N1, M0) in this study. All the patients were planned for IMRT and VMAT with simultaneous integrated boost technique. IMRT and VMAT plans were performed with jaw tracking (JT) and with static jaw (SJ) technique by keeping the same constraints and priorities for a particular patient. Target conformity, dose to the critical structures and low dose volumes were recorded and analyzed for IMRT and VMAT plans with and without JT for all the patients. Results: The conformity index average of all patients followed by standard deviation (${\bar{x}}{\pm}{\sigma}_{\bar{x}}$) of the JT-IMRT, SJ-IMRT, JT-VMAT, and SJ-VMAT were $1.72{\pm}0.56$, $1.67{\pm}0.57$, $1.83{\pm}0.65$, and $1.85{\pm}0.64$, and homogeneity index were $0.059{\pm}0.05$, $0.064{\pm}0.05$, $0.064{\pm}0.04$, and $0.064{\pm}0.05$. JT-IMRT shows significant mean reduction in right parotid and left parotid shows of 7.64% (p < 0.001) and 7.45% (p < 0.001) compare to SJ-IMRT. JT-IMRT plans also shows considerable dose reduction to thyroid, inferior constrictors, spinal cord and brainstem compared to the SJ-IMRT plans. Conclusion: Significant dose reductions were observed for critical structure in the JT-IMRT compared to SJ-IMRT technique. In JT-VMAT plans dose reduction to the critical structure were not significant compared to the SJ-IMRT due to relatively lesser monitor units.

Dosimetric Validation of the Acuros XB Advanced Dose Calculation Algorithm for Volumetric Modulated Arc Therapy Plans

  • Park, So-Yeon;Park, Jong Min;Choi, Chang Heon;Chun, Minsoo;Kim, Jung-in
    • 한국의학물리학회지:의학물리
    • /
    • 제27권4호
    • /
    • pp.180-188
    • /
    • 2016
  • Acuros XB advanced dose calculation algorithm (AXB, Varian Medical Systems, Palo Alto, CA) has been released recently and provided the advantages of speed and accuracy for dose calculation. For clinical use, it is important to investigate the dosimetric performance of AXB compared to the calculation algorithm of the previous version, Anisotropic Analytical Algorithm (AAA, Varian Medical Systems, Palo Alto, CA). Ten volumetric modulated arc therapy (VMAT) plans for each of the following cases were included: head and neck (H&N), prostate, spine, and lung. The spine and lung cases were treated with stereotactic body radiation therapy (SBRT) technique. For all cases, the dose distributions were calculated using AAA and two dose reporting modes in AXB (dose-to-water, $AXB_w$, and dose-to-medium, $AXB_m$) with same plan parameters. For dosimetric evaluation, the dose-volumetric parameters were calculated for each planning target volume (PTV) and interested normal organs. The differences between AAA and AXB were statistically calculated with paired t-test. As a general trend, $AXB_w$ and $AXB_m$ showed dose underestimation as compared with AAA, which did not exceed within -3.5% and -4.5%, respectively. The maximum dose of PTV calculated by $AXB_w$ and $AXB_m$ was tended to be overestimated with the relative dose difference ranged from 1.6% to 4.6% for all cases. The absolute mean values of the relative dose differences were $1.1{\pm}1.2%$ and $2.0{\pm}1.2%$ when comparing between AAA and $AXB_w$, and AAA and $AXB_m$, respectively. For almost dose-volumetric parameters of PTV, the relative dose differences are statistically significant while there are no statistical significance for normal tissues. Both $AXB_w$ and $AXB_m$ was tended to underestimate dose for PTV and normal tissues compared to AAA. For analyzing two dose reporting modes in AXB, the dose distribution calculated by $AXB_w$ was similar to those of AAA when comparing the dose distributions between AAA and $AXB_m$.

RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때 전달선량의 정확성 평가 (Evaluation of the Accuracy for Respiratory-gated RapidArc)

  • 성지원;윤명근;정원규;배선현;신동오;김동욱
    • 한국의학물리학회지:의학물리
    • /
    • 제24권2호
    • /
    • pp.127-132
    • /
    • 2013
  • 환자 호흡할 때 흉 복부 내부에 있는 장기의 위치는 주기적으로 변한다. 이에 따라 방사선치료 동안 종양에 대한 선량불확도가 발생하게 되며, 불확도를 줄이기 위한 여러 방사선치료방법이 제시되고 있다. 호흡연동방사선치료는 특정 위상 또는 진폭에만 방사선을 조사하는 방법으로 불필요한 피폭선량은 줄일 수 있는 장점이 있지만 긴 치료 시간과 노력이 필요하다는 단점이 있다. 호흡연동방사선치료 중 회전세기조절방사선치료(respiratory gated Volumetric Modulated Arc Therapy, VMAT)는 다른 호흡연동치료시스템에 비해 치료 시간이 짧다는 장점이 있기 때문에 본 연구는 respiratory gated VMAT 치료 선량의 정확성을 검증하여 임상 적용의 적절성을 평가하고자 한다. 본 연구는 총 6개의 VMAT 치료계획(Eclipse, ver. 8.6, Palo Alto, USA)을 토대로 수행되었으며, 각각의 치료계획은 AAA 알고리즘을 이용해서 선량이 계산되었다. 환자의 호흡운동을 구현하기 위해 환자 테이블 위에 1차원운동팬텀이 사용되었으며, 영상 기반 추적 시스템(Real-time Position Management, RPM, Varian Medical Systems, Palo Alto, USA)을 통해 운동 주기 신호를 획득하였다. 또한, 2차원-이온함-배열(MatriXX, IBA, Germany) 측정기를 이용하여 특정 호흡 신호 위상에 따른 전달 선량을 측정하였다. 측정된 선량과 치료 계획된 선량을 정성적인 분석을 위해 상용화되어 있는 선량분석용 프로그램(I'mRT, IBA, Germany)을 통해 2차원 선량분포를 0에서 1사이의 감마지표(Gamma index) 비교 결과 모든 케이스에서 97% 이상의 일치함을 확인하였다. 따라서 호흡연동 회전세기조절 방사선치료는 호흡연동방사선치료의 단점인 시간적인 제약을 일정 부분 해소할 수 있었으며 2차원 선량분포 비교 결과 오차값 3%이내의 정확도에서 환자정도관리 수준을 만족하였고 임상적용이 가능함을 확인하였다.

EQUIVALENT DOSE FROM SECONDARY NEUTRONS AND SCATTER PHOTONS IN ADVANCE RADIATION THERAPY TECHNIQUES WITH 15 MV PHOTON BEAMS

  • Ayuthaya, Isra Israngkul Na;Suriyapee, Sivalee;Pengvanich, Phongpheath
    • Journal of Radiation Protection and Research
    • /
    • 제40권3호
    • /
    • pp.147-154
    • /
    • 2015
  • The scatter photons and photoneutrons from high energy photon beams (more than 10 MV) will increase the undesired dose to the patient and the staff working in linear accelerator room. This undesired dose which is found at out-of-field area can increase the probability of secondary malignancy. The purpose of this study is to determine the equivalent dose of scatter photons and neutrons generated by 3 different treatment techniques: 3D-conformal, intensity modulated radiation therapy (IMRT) and volumetric modulated arc therapy (VMAT). The measurement was performed using two types of the optically stimulation luminescence detectors (OSL and OSLN) in the Alderson Rando phantom that was irradiated by 3 different treatment techniques following the actual prostate cancer treatment plans. The scatter photon and neutron equivalent dose were compared among the 3 treatments techniques at the surface in the out-of-field area and the critical organs. Maximum equivalent dose of scatter photons and neutrons was found when using the IMRT technique. The scatter neutrons showed average equivalent doses of 0.26, 0.63 and $0.31mSv{\cdot}Gy^{-1}$ at abdominal surface region which was 20 cm from isocenter for 3D, IMRT and VMAT, respectively. The scattered photons equivalent doses were 6.94, 10.17 and $6.56mSv{\cdot}Gy^{-1}$ for 3D, IMRT and VMAT, respectively. For the 5 organ dose measurements, the scattered neutron and photon equivalent doses in out of field from the IMRT plan were highest. The result revealed that the scatter equivalent doses for neutron and photon were higher for IMRT. So the suitable treatment techniques should be selected to benefit the patient and the treatment room staff.

선형가속기 기반 뇌정위 방사선 수술기법 (Methodologic Aspect of LINAC-based Stereotactic Radiosurgery)

  • 최태진
    • 한국의학물리학회지:의학물리
    • /
    • 제23권3호
    • /
    • pp.127-137
    • /
    • 2012
  • Leksell은 뇌동정맥기형종의 중심에 280 kVp 관전압 방사선빔을 집속하는 방법으로 방사선수술법을 고안 시술한 바 있으며, 이 후 코발트-60 감마 선원 201개의 선속이 헬멧콜리메터를 지나 구의 중심에 초점을 이루게 한 감마나이프를 개발하여 표적병변에 높은 선량을 주어 비침습적으로 수술효과를 얻었다. 선형가속기는 높은 선량률과 1 mm 이내의 갠트리회전중심과 안정된 치료대회전 및 선량성능검증효과와 획기적으로 발전된 3차원선량계획 전산화에 힘입어 정밀하고 높은 정확성에 바탕을 둔 비공면궤적으로 방사선을 환부에 집속할 수 있어, 병변 주위의 정상조직에는 낮은 선량이 도달하고 병변에 높은 선량을 줄 수 있는 뇌정위방사선수술에 이용할 수 있게 되었다. 특히 Photon Knife는 환자의 체축을 이용하여 선속이 환부를 중심으로 종횡의 비공면궤적을 이루게 하여 치료선량분포에서 90%와 50% 선량폭을 2~3 mm 까지 좁힐 수 있는 기법을 보였다. 최근 선형가속기의 방사선수술은 2.5~3 mm 폭의 초박형 다엽콜리메터를 이용한 세기조절에 의한 시술이 늘어나는 경향이며, 종전의 종양의 크기에 따른 제한을 넘어 3 cm 이상의 종양에도 시행되고 있다. 뇌정위방사선수술은 선량모델을 뒷받침하는 마이크로 선량계측 및 평가와 성능보증이 필수적이며 선량분포의 경사도를 높이는 기법이 지속적으로 연구되어야 한다. 특히 초박형다엽콜리메터를 이용한 방사선수술은 다엽콜리메터 요철(Tongue and groove) 에 의해 일어나는 표적내 선량저하 부위를 평가하고 균등한 표적선량이 이루어지도록 하며, 마이크로 분해능을 가진 선량검증 방법이 앞으로 더욱 발전할 것으로 보인다.