• 제목/요약/키워드: Modified fluid loss test

검색결과 11건 처리시간 0.028초

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.498-507
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

Evaluation of Hydraulic Conductivity of Bentonite Filter Cake Using Modified Fluid Loss Test

  • Nguyen, The Bao;Lee, Chul-Ho;Yang, Jung-Hun;Choi, Hang-Seok
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1502-1511
    • /
    • 2008
  • The mixture of bentonite powder and water is generally used to maintain the stability of excavation surface during the construction of vertical cutoff walls. The filter cake on the sidewall surface is the result of filtration of slurry into the adjacent soil formation. The filter cake is believed to have a very low hydraulic conductivity compared to that of the cutoff wall. This paper evaluates hydraulic conductivities of bentonite filter cakes set up with three types of bentonites under various pressure levels. A modified fluid loss test was employed in this experiment. Theory of filtration process was reviewed to explain the procedure in the present experiment. Hydraulic conductivity of the filter cakes with consideration of the filter medium resistance was evaluated. The results of the experiment with two calculation methods and discussion are presented to show the efficiency of the modified fluid loss test.

  • PDF

수정 fluid loss 시험을 이용한 연직 차수벽에 생성된 벤토나이트 필터케익 특성 평가 (Characteristics of Bentonite Filter Cake on Vertical Cutoff Walls Evaluated by Modified Fluid Loss Test)

  • 웽테바오;박문석;임지희;최항석;한신인
    • 한국지반공학회논문집
    • /
    • 제27권2호
    • /
    • pp.53-62
    • /
    • 2011
  • 연직 차수벽 시공 시, 벤토나이트 슬러리는 토양층으로 여과되면서 차수벽의 측벽 표면에 필터케익 층을 형성하고 이렇게 형성된 필터케익은 차수벽의 자체 투수계수보다 매우 낮은 값을 갖는다. 본 연구에서는 수정 fluid loss 시험을 수행하여 다양한 작용압력 하에서 슬러리월 시공현장에서 주로 사용되는 세 가지 종류의 벤토나이트로 형성된 필터케익의 투수계수를 평가하였다. 수정 fluid loss 시험에서는 일반적인 연직 차수벽 시공 조건을 반영하기 위해 중량비 4, 6, 8% 농도의 벤토나이트 슬러리를 적용하였다. 벤토나이트 필터케익의 투수계수를 예측하기 위해 수정 fluid loss 시험 결과를 기존에 제안된 두 가지 방법을 이용하여 해석하였다. 본 연구결과로부터 평가된 세 가지 벤토나이트 필터케익의 투수계수는 $2.15{\times}10^{-11}m/s$$2.88{\times}10^{-10}m/s$ 범위로 이는 일반적인 연직차수벽 뒤채움재의 설계값 보다 10-1000배 가량 작음을 알 수 있다. 또한, 필터케익 내 응력분포와 필터케익의 두께가 각 조건에 대해 비교되었다.

Modified TOUGHREACT를 이용한 지중 열교환기 내 순환 유체의 온도 분포 추정 (A Study to Calculate Inlet Fluid Temperature of the Borehole Heat Exchanger (BHE) using Modified TOUGHREACT)

  • 김성균;배광옥;이강근;심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.477-480
    • /
    • 2007
  • Inlet fluid temperature of the BRE in the geothermal heat pump system depends on heat exchange rate between the refrigerant of the heat pump and the leaving fluid from the BRE. Because the outlet fluid temperature of the BHE varies with time, inlet fluid temperature has to vary with time. In this study, the module to calculate inlet fluid temperature is developed, which can consider the time-varying outlet fluid temperature and the heat exchange capacity of the heat pump. It is assumed that heat loss or gain of the leaving fluid from outlet to inlet of the BHE is negligible, except when the fluid contacts with the refrigerant of the heat pump. This module is combined with TOUGHREACT, a widely accepted three-dimensional numerical simulator for heat and water flow and geochemical reactions in geothermal systems and is applied to data analyses of the thermal response test.

  • PDF

SEAMLESS 관의 마찰손실에 따른 작동유체의 임피던스 특성 (Impedance Characteristics of operate fluid about Frictional loss in seamless pipeline)

  • 모양우;유영태;최병재
    • 한국공작기계학회:학술대회논문집
    • /
    • 한국공작기계학회 2001년도 추계학술대회(한국공작기계학회)
    • /
    • pp.304-310
    • /
    • 2001
  • Flow pulsation often causes vibration and noise in piping systems and therefore has been a troublesome concern for fluid system engineers. According to frequency increase in this paper under the influence wave form of velocity in springly flow and viscosity are drop coefficient of viscosity become increase so that impedance and resistance. The transient variations of flow rate are measured by a modified impedance tube method which is realized by virtue of the present analytical technique. At pipe line in order to eliminate vibration, confirm happened intermittently impedance characteristics. We make a test and frequency analysis and have to minimize obstructive component at hydraulic circuit.

  • PDF

과급기의 고압력비 원심압축기 공력설계 및 시험평가 (Performance Test and Aerodynamic Design on the High Pressure Ratio Centrifugal Compressor of a Turbocharger)

  • 김홍원;류승협;이근식
    • 한국유체기계학회 논문집
    • /
    • 제17권6호
    • /
    • pp.13-20
    • /
    • 2014
  • It is necessary to design a compressor with high pressure ratio that satisfies the IMO(international maritime organization) NOx emission regulation for the marine diesel engine. Impeller was designed using the modified slip factor with the flow coefficient. The main purpose of this study is to investigate the sensitivity of the compressor performance by the vaned diffuser geometries. The first vaned diffuser type was based on a NACA airfoil, the second was channel diffuser, and the third was conformally transformated configuration of a NACA65(4A10)06 airfoil. The sensitivity of the performance was calculated using a commercial CFD program for three different diffuser geometries. The channel diffuser showed the wide range of operation and higher pressure characteristics, comparing with the others. This is attributed to the flow stability at diffuser. Combined with this results with impeller design, the optimized compressor was designed and verified by the test results.

Correlation between microleakage and screw loosening at implant-abutment connection

  • Sahin, Cem;Ayyildiz, Simel
    • The Journal of Advanced Prosthodontics
    • /
    • 제6권1호
    • /
    • pp.35-38
    • /
    • 2014
  • PURPOSE. This study aimed to evaluate the correlation between microleakage and screw loosening at different types of implant-abutment connections and/or geometries measuring the torque values before and after the leakage tests. MATERIALS AND METHODS. Three different abutment types (Intenal hex titanium, internal hex zirconium, morse tapered titanium) with different geometries were connected to its own implant fixture. All the abutments were tightened with a standard torque value then the composition was connected to the modified fluid filtration system. After the measurements of leakage removal torque values were re-measured. Kruskal-wallis test was performed for non-parametric and one-way ANOVA was performed for parametric data. The correlation was evaluated using Spearman Correlation Test (${\alpha}=0.05$). RESULTS. Significantly higher microleakage was found at the connection of implant-internal hex zirconium abutment. Observed mean torque value loss was also significantly higher than other connection geometries. Spearman tests revealed a significant correlation between microleakage and screw loosening. CONCLUSION. Microleakage may provoke screw loosening. Removing torque values rationally decrease with the increase of microleakage.

Prediction of transverse settlement trough considering the combined effects of excavation and groundwater depression

  • Kim, Jonguk;Kim, Jungjoo;Lee, Jaekook;Yoo, Hankyu
    • Geomechanics and Engineering
    • /
    • 제15권3호
    • /
    • pp.851-859
    • /
    • 2018
  • There are two primary causes of the ground movement due to tunnelling in urban areas; firstly the lost ground and secondly the groundwater depression during construction. The groundwater depression was usually not considered as a cause of settlement in previous research works. The main purpose of this study is to analyze the combined effect of these two phenomena on the transverse settlement trough. Centrifuge model tests and numerical analysis were primarily selected as the methodology. The characteristics of settlement trough were analyzed by performing centrifuge model tests where acceleration reached up to 80g condition. Two different types of tunnel models of 180 mm diameter were prepared in order to match the prototype of a large tunnel of 14.4 m diameter. A volume loss model was made to simulate the excavation procedure at different volume loss and a drainage tunnel model was made to simulate the reduction in pore pressure distribution. Numerical analysis was performed using FLAC 2D program in order to analyze the effects of various groundwater depression values on the settlement trough. Unconfined fluid flow condition was selected to develop the phreatic surface and groundwater level on the surface. The settlement troughs obtained in the results were investigated according to the combined effect of excavation and groundwater depression. Subsequently, a new curve is suggested to consider elastic settlement in the modified Gaussian curve. The results show that the effects of groundwater depression are considerable as the settlement trough gets deeper and wider compared to the trough obtained only due to excavation. The relationships of maximum settlement and infection point with the reduced pore pressure at tunnel centerline are also suggested.

Ribbed 管의 管傾斜角이 熱傳達에 미치는 影響 (The effect of inclined ribbed tubes on heat transfer and friction loss)

  • 박성찬;김종보
    • 대한기계학회논문집
    • /
    • 제11권1호
    • /
    • pp.105-109
    • /
    • 1987
  • 본 연구는 열교환기의 설치 및 사용목적에 따라 전열관내유동이 경사류가 될 때 특히 자연순환(2*$10^{6}$<Gr<15*$10^{6}$)의 경우와 강제순환(3,000<Re< 40,000)의 경우에 대해서 열전달특성과 유동마찰에 의한 손질을 규명하는데 있다. 사용되는 관은 평골관과 ribbed관이며 관경사각을 수평면에 대하여 0˚,22.5˚,45˚, 90˚로 변화시켰다.

Pile tip grouting diffusion height prediction considering unloading effect based on cavity reverse expansion model

  • Jiaqi Zhang;Chunfeng Zhao;Cheng Zhao;Yue Wu;Xin Gong
    • Geomechanics and Engineering
    • /
    • 제37권2호
    • /
    • pp.97-107
    • /
    • 2024
  • The accurate prediction of grouting upward diffusion height is crucial for estimating the bearing capacity of tip-grouted piles. Borehole construction during the installation of bored piles induces soil unloading, resulting in both radial stress loss in the surrounding soil and an impact on grouting fluid diffusion. In this study, a modified model is developed for predicting grout diffusion height. This model incorporates the classical rheological equation of power-law cement grout and the cavity reverse expansion model to account for different degrees of unloading. A series of single-pile tip grouting and static load tests are conducted with varying initial grouting pressures. The test results demonstrate a significant effect of vertical grout diffusion on improving pile lateral friction resistance and bearing capacity. Increasing the grouting pressure leads to an increase in the vertical height of the grout. A comparison between the predicted values using the proposed model and the actual measured results reveals a model error ranging from -12.3% to 8.0%. Parametric analysis shows that grout diffusion height increases with an increase in the degree of unloading, with a more pronounced effect observed at higher grouting pressures. Two case studies are presented to verify the applicability of the proposed model. Field measurements of grout diffusion height correspond to unloading ratios of 0.68 and 0.71, respectively, as predicted by the model. Neglecting the unloading effect would result in a conservative estimate.