• Title/Summary/Keyword: Modified Westergren

Search Result 2, Processing Time 0.014 seconds

Evaluation of Automated ESR Measuring System, $SEDIsystem^{TM}$ ($SEDIsystem^{TM}$을 이용한 적혈구 침강속도 측정의 평가)

  • Lee, Jung-Ee;Kim, Kyung-Dong;Lee, Chae-Hoon;Kim, Chung-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.13 no.1
    • /
    • pp.110-115
    • /
    • 1996
  • The ESR is one of the oldest laboratory test still in use. Although it lacks specificity in diagnosis, it can be effective for monitoring disease activity and following-up. The Westergren method is used for reference method, however coefficient of variation has been described 0.8% to 22.9% according to the literature. Since the ESR was invented in 1921, measurement technique has developed and automated measurement is introduced. We analyzed one hundred forty-three patient samples using $SEDIsystem^{TM}$ automated ESR measuring system and compared with modified Westergren and Wintrobe methods. Comparison between $SEDIsystem^{TM}$ and modified Westergren for ESR measurement yields the following regression equation; y = 0.863x - 1.69 (r=0.830), $SEDIsystem^{TM}$ and Wintrobe y = 1.14x - 14.7 (r=0.789), respectively. We repeated measurement to evaluate reliability, results are not significant in statistically. In conclusion, $SEDIsystem^{TM}$ automated ESR measurement correlated with modified Westergren and Wintrobe methods, reveal reliable results after 4 hours and can report rapidly for large samples. Thus, these results indicate that $SEDIsystem^{TM}$ automated ESR measurement may be useful tool for clinical practice.

  • PDF

The effect of Westergren tube angle, temperature and osmobility with the different percent of NaCl solution on erythrocyte sedimentation rate (적혈구 침강속도에 대한 Westergren tube 각도, 온도 및 NaCl 농도가 미치는 영향)

  • Kim, Do-kyun;Kim, Young-hong;Yu, Chang-jun
    • Korean Journal of Veterinary Research
    • /
    • v.36 no.1
    • /
    • pp.75-82
    • /
    • 1996
  • Erythrocyte sedimentation rate is influenced by plasma protein, red cell itself and physiological conditions and it is clear that the measurement of erythrocyte sedimentation rate varies with technique and various environmental factors. The effect of temperature, angle of test tube, and osmobility with different percent of NaCl solution on erythrocyte sedimentation rate on sheep was determined by modified Westergren method. In sheep, as the angle of Westergren tube was decreased from $90^{\circ}$ to $45^{\circ}$, erythrocyte sedimentation rate was increased in both diluted plasma and NaCl solutions. As temperature was increased from $4^{\circ}C$ to $20^{\circ}C$ at $45^{\circ}$ angle. erythrocyte sedimentation rate was increased. In ruminants, this modified Westergren methods, erythrocyte 1 : plasma 9 instead of erythrocyte 4 : plasma 6(whole blood), enable them to have meanings as dog therefor, using this method, clinical can determine the erythrocyte sedimentation rate of ruminants for diagnosis. Because erythrocyte sedimentation rate was changed according to the angle of Westergren tube, temperature as erythrocyte diluted with NaCl, this study detected that the change of temperature, the angle of Westergren tube could change erythrocyte sedimentation rate by effecting red cell itself. The increase of osmobility owing to change of NaCl percent resulted in the decrease of rapid erythrocyte sedimentation rate. So this fact indicate that deformibility and the change of red cell volume have meaning in the change of erythrocyte sedimentation rate.

  • PDF