• Title/Summary/Keyword: Modeling of cooling tube

Search Result 14, Processing Time 0.022 seconds

Parametric Study on Performance of Inertance Pulse Tube Cryocooler

  • Lee, K.H.;Rhee, J.;Kim, J.S.
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.15 no.2
    • /
    • pp.205-211
    • /
    • 2014
  • The design parameters to affect the cooling capacity of a cryocooler were examined with the application of numerical modeling to optimize an inertance pulse tube cryocooler. This modeling includes the regenerator, pulse tube, inertance tube, gas reservoir, and heat exchangers. One-dimensional modeling on strings of acoustic and thermoacoustic elements was applied to compare the design parameters. The diameter and length of the pulse tube can significantly affect the cooling capacity and efficiency. The aftercooler was optimized by maintaining a certain size. The efficiency also improved as the length of inertance tube and volume of gas reservoir are increased. It was confirmed that effective design parameters are critical to the performance of an inertance pulse tube cryocooler considering the comparison of the dimensions of each part to optimize its cooling power and efficiency.

Modeling of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners using Accelerated Particle-Loading System (파울링 가속장치를 이용한 공기조화기용 열교환기의 공기측 파울링 특성에 대한 예측 모델링)

  • Ahn Young-Chull;Lee Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.17 no.3
    • /
    • pp.262-267
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. The purpose of this study is to investigate and to model the air-side particulate fouling characteristics of the heat exchangers using accelerated particle loading system. The main variables of the modeling equation are face velocity and dust concentration. The modeling equation shows good agreements with the experimental results at the face velocity of 0.5, 1.0, 1.5 m/s and the dust concentration of 1.28 and $3.84\;g/m^3$. It will be very useful to predict fouling characteristics such as variations of pressure drop and heat transfer capacity in finned-tube heat exchangers of air conditioners.

The Performance Analysis of the Fin-Tube Heat Exchanger Using CFC Alternative Refrigerant (CFC 대체냉매를 사용한 핀-관 열교환기의 성능해석)

  • 박희용;박경우;차재병
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.17 no.9
    • /
    • pp.2358-2372
    • /
    • 1993
  • In this study, the computer modeling for prediction of the performance of fin-tube heat exchanger using alternative refrigerant, HFC-134a was developed and the computer program for calculating the various properties of HFC-134a and the existing refrigerant CFC-12 and HCFC-22 was made. The heat exchanger modeling is based on a tube-by-tube approach, which is capable of analysis for the complex coil array. Performance of each tube is analyzed separately by considering the cross-flow heat transfer with external airstream and the appropriate heat and mass transfer relationships. A performance comparison according to the different refrigerants is provided using this developed model. As the result of this study, total heat transfer rate of evaporator and condenser using HFC-134a were found higher than that of using CFC-12 for the same operating conditions. When the mass flow rate of HFC-134a was less than CFC-12 about 18. 16%, the cooling capacities of evaporator were found to be the same.

Prediction of the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화가용 열교환기의 공기측 파울링 특성 예측)

  • Hwang, Yu-Jin;Kim, Gil-Tae;Jeong, Seong-Il;Lee, Jae-Geun;Ahn, Young-Chull
    • Proceedings of the SAREK Conference
    • /
    • 2005.11a
    • /
    • pp.306-310
    • /
    • 2005
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performance of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation is derived from the experimental results using accelerated tests and it shows good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data. The purpose of this study is to modify the previous modeling equation using the actual field data Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.

  • PDF

A Study on the Optimized Pump Selection of the Cooling System for the PEFP DTL Accelerator (PEFP DTL 냉각시스템의 펌프 선정 최적화에 관한 연구)

  • Park, Jun;Kim, Kyung-Ryul;Kim, Hyung-Gyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1277-1282
    • /
    • 2009
  • The main objective of this prototype is to control resonance frequency of DTL system through the temperature control of cooling water. It is to resonant frequency of the drift tube cavities to 350 MHz. This paper describes the design of a prototype cooling water skid required for the temperature control of the DTL cavities, focusing in the modeling and simulation of the cooling system, the sizing of water pumping skid component.

  • PDF

MODELING ON FLOW CHARACTERISTICS OF INERTANCE PULSE TUBE CRYOCOOLER (관성관 맥동관 극저온 냉동기의 유동 특성 모델링)

  • Han, S.H.;Lee, K.H.;Choi, J.W.;Kim, J.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.14-19
    • /
    • 2014
  • The flow characteristics of inertance pulse tube cryocooler(IPTC) was investigated with a computational thermal fluid dynamics for the reciprocating flow in IPTC including the piston movement of linear compressor. Two dimensional axisymmetric modeling was applied for the flow in an IPTC with a clearance between the piston and cylinder wall of linear compressor. The pressure, velocity, and temperature distribution were examined for the steady state. These were compared with previous results to confirm the validity in the modeling and computational results. The leakage between piston and cylinder wall affect the cooling capacity seriously. The dependence on mesh numbers were also examined to obtain a proper mesh numbers to improve the accuracy of calculation, which showed significant effect on the results. The user-defined function was used for the process of compression and expansion of piston.

Diameter Evaluation for PHWR Pressure Tube Based on the Measured Data (측정 데이터 기반 중수로 압력관 직경평가 방법론 개발)

  • Jong Yeob Jung;Sunil Nijhawan
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.19 no.1
    • /
    • pp.27-35
    • /
    • 2023
  • Pressure tubes are the main components of PHWR core and serve as the pressure boundary of the primary heat transport system. However, because pressure tubes have changed their geometrical dimensions under the severe operating conditions of high temperature, high pressure and neutron irradiation according to the increase of operation time, all dimensional changes should be predicted to ensure that dimensions remain within the allowable design ranges during the operation. Among the deformations, the diameter expansion due to creep leads to the increase of bypass flow which may not contribute to the fuel cooling, the decrease of critical channel power and finally the deration of the power to maintain the operational safety margin. This study is focused on the modeling of the expansion of the pressure tube diameter based on the operating conditions and measured diameter data. The pressure tube diameter expansion was modeled using the neutron flux and temperature distributions of each fuel channel and each fuel bundle as well as the measured diameter data. Although the basic concept of the current modeling approach is simple, the diameter prediction results using the developed methodology showed very good agreement with the real data, compared to the existing methodology.

A Study on the Design and Performance of a Prototype Pumping Skid for Resonant Frequency Control in the PEFP DTL (PEFP DTL 가속장치의 공진주파수 제어를 위한 펌프장치의 설계 및 성능에 관한 연구)

  • Kim, Kyung-Ryul;Park, Jun;Kim, Hyung-Gyun;Kim, Hee-Sub;Hwang, Woon-Ha;Yoon, Jong-Cheol;Lee, Mong-Su;Cho, En-Byul
    • Proceedings of the KSME Conference
    • /
    • 2008.11b
    • /
    • pp.2064-2069
    • /
    • 2008
  • The Resonance Control Cooling System (RCCS) prototype installed in KAERI site has been designed to control the resonant frequency of the normal conducting drift tube linac (DTL) for the Proton Engineering Frontier Project (PEFP). The RCCS water pumping skid is composed of two channels as a by-passing the cooling water and a plate heat exchanger. The required temperature can be achieved by mixing both channels in order to control its the resonant frequency at 350 MHz. The temperature controlled water pumping skid operates in combination with the Low Level Radio Frequency (LLRF) system. We have discussed the design, modeling with each components, control scheme, fabrication and test results of the water pumping skid for resonant frequency control of the DTL cavity. In conclusion, the fabricated RCCS prototype through the optimization of modeling has corresponded with the design requirement and concept.

  • PDF

Analysis on Fluid Dynamics in the Cooling Tube for Manufacture of Liquid Hydrogen (액체수소 제조를 위한 냉각튜브 내 유동장 해석)

  • LEE, DAE-WON;NGUYEN, HOANG HAI;NASONOVA, ANNA;OH, IN-HWAN;KIM, KYO-SEON
    • Journal of Hydrogen and New Energy
    • /
    • v.26 no.4
    • /
    • pp.301-307
    • /
    • 2015
  • We present a study of hydrogen liquefaction using the CFD (Computational Fluid Dynamics) program. Liquid hydrogen has been evaluated as the best storage method because of high energy per unit mass than gas hydrogen, but efficient hydrogen liquefaction and storage are needed in order to apply actual industrial. In this study, we use the CFD program that apply navier-stokes equation. A hydrogen is cooled by heat transfer with the while passing gas hydrogen through Cu tube. We change diameter and flow rate and observe a change of the temperature and flow rate of gas hydrogen passing through Cu tube. As a result of, less flow rate and larger diameter are confirmed that liquefaction is more well. Ultimately, When we simulate the hydrogen liquefaction by using CFD program, and find optimum results, it is expected to contribute to the more effective and economical aspects such as time and cost.

Prediction of Characteristics for the Air-side Particulate Fouling in Finned-Tube Heat Exchangers of Air Conditioners used in the Field (실공간 사용 공기조화기용 열교환기의 공기측 파울링 특성 예측)

  • Ahn, Young-Chull;Jung, Sung-Hak;Hwang, Yu-Jin;Lee, Chang-Gun;Kim, Doo-Hyun;Jung, Seong-Ir;Lee, Jae-Keun
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.19 no.8
    • /
    • pp.563-568
    • /
    • 2007
  • The air-side particulate fouling in the heat exchangers of HVAC applications degrades the performances of cooling capacity, pressure drop across a heat exchanger, and indoor air quality. Indoor and outdoor air contaminants foul heat exchangers. An empirical modeling equation has been derived from the experimental results using accelerated tests and it showed good predictions of the fouling characteristics of the slitted finned tube heat exchangers. However the modeling equation predicts only the fouling characteristics of new heat exchangers and it can not predicts fouling characteristics obtained from actual field data which contains the effect of hydrophilicity deterioration. Therefore an modified modeling equation is proposed and it shows good predictions of the actual fouling characteristics of finned-tube heat exchangers.