• Title/Summary/Keyword: Model Surgery

Search Result 1,557, Processing Time 0.031 seconds

A PREDICTION OF BONY INTERFERENCE BETWEEN PROXIMAL & DISTAL SEGMENT OF THE MANDIBLE WITH INTEGRATED 3D SOLID MODEL AND DENTAL CAST IN ORTHOGNATHIC SURGERY (턱교정 수술에서 3차원 입체 모델과 치아 석고모형의 결합을 이용한 하악 근원심 골편간 간섭의 예측)

  • Kwon, Tae-Geon;Lee, Sang-Han;Kim, Jong-Bae;Nam, Ki-Young
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.29 no.3
    • /
    • pp.163-168
    • /
    • 2003
  • Three-dimensional solid model has not been widely used in surgical prediction of orthognathic surgery because frequent artifacts from occlusal restorations or prosthesis limited the usefulness of simulated surgery involving occlusion. We prepared three-dimensional(3D) solid model from CT data and integrated the 3D solid model with dental cast using a face-bow transfer technique combined with skeletal reference measurement and confirmation with cephalometric radiographs. With this simple and easy method, it was possible to predict bony interference between the proximal and distal segment of the mandible so that we can prevent condylar displacement after sagittal split ramus osteotomy of the mandible with prominent asymmetry. The method error was within 2mm and it seemed to be useful in preoperative planning for maxillofacial surgery with maxillo-mandibular occlusal change.

Development of Models for Regional Cardiac Surgery Centers

  • Park, Choon Seon;Park, Nam Hee;Sim, Sung Bo;Yun, Sang Cheol;Ahn, Hye Mi;Kim, Myunghwa;Choi, Ji Suk;Kim, Myo Jeong;Kim, Hyunsu;Chee, Hyun Keun;Oh, Sanggi;Kang, Shinkwang;Lee, Sok-Goo;Shin, Jun Ho;Kim, Keonyeop;Lee, Kun Sei
    • Journal of Chest Surgery
    • /
    • v.49 no.sup1
    • /
    • pp.28-36
    • /
    • 2016
  • Background: This study aimed to develop the models for regional cardiac surgery centers, which take regional characteristics into consideration, as a policy measure that could alleviate the concentration of cardiac surgery in the metropolitan area and enhance the accessibility for patients who reside in the regions. Methods: To develop the models and set standards for the necessary personnel and facilities for the initial management plan, we held workshops, debates, and conference meetings with various experts. Results: After partitioning the plan into two parts (the operational autonomy and the functional comprehensiveness), three models were developed: the 'independent regional cardiac surgery center' model, the 'satellite cardiac surgery center within hospitals' model, and the 'extended cardiac surgery department within hospitals' model. Proposals on personnel and facility management for each of the models were also presented. A regional cardiac surgery center model that could be applied to each treatment area was proposed, which was developed based on the anticipated demand for cardiac surgery. The independent model or the satellite model was proposed for Chungcheong, Jeolla, North Gyeongsang, and South Gyeongsang area, where more than 500 cardiac surgeries are performed annually. The extended model was proposed as most effective for the Gangwon and Jeju area, where more than 200 cardiac surgeries are performed annually. Conclusion: The operation of regional cardiac surgery centers with high caliber professionals and quality resources such as optimal equipment and facility size, should enhance regional healthcare accessibility and the quality of cardiac surgery in South Korea.

Mandibular Reconstruction using Simulation Surgery with 3D RP Model in Osteoradionecrosis Patient: A Case Report

  • Park, Tae-Jun;Kim, Hong-Joon;Ahn, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.2 no.2
    • /
    • pp.76-79
    • /
    • 2015
  • One of the most serious complications after head and neck radiation is osteoradionecrosis (ORN) of the jaw. The etiology of ORN is extraction, minor dental procedure or dental implant surgery. When ORN of the jaw progressed to stage III, free fibular flap is the most useful methods for reconstruction. In this case report, a 67-year-old ORN patient who underwent fibular free flap reconstruction using simulation surgery with 3-dimensional rapid prototype (3D RP) model was reviewed. After partial mandibulectomy, a osteocutaneous fibula flap was used for reconstruction. Oro-cutaneous fistula was resolved after operation. Patients reported improved food intake after operation without pus discharge. Functional and esthetic results showed successful reconstruction.

Accuracy of simulation surgery of Le Fort I osteotomy using optoelectronic tracking navigation system (광학추적항법장치를 이용한 르포씨 제1형 골절단 가상 수술의 정확성에 대한 연구)

  • Bu, Yeon-Ji;Kim, Soung-Min;Kim, Ji-Youn;Park, Jung-Min;Myoung, Hoon;Lee, Jong-Ho;Kim, Myung-Jin
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.37 no.2
    • /
    • pp.114-121
    • /
    • 2011
  • Introduction: The aim of this study was to demonstrate that the simulation surgery on rapid prototype (RP) model, which is based on the 3-dimensional computed tomography (3D CT) data taken before surgery, has the same accuracy as traditional orthograthic surgery with an intermediate splint, using an optoelectronic tracking navigation system. Materials and Methods: Simulation surgery with the same treatment plan as the Le Fort I osteotomy on the patient was done on a RP model based on the 3D CT data of 12 patients who had undergone a Le Fort I osteotomy in the department of oral and maxillofacial surgery, Seoul National University Dental Hospital. The 12 distances between 4 points on the skull, such as both infraorbital foramen and both supraorbital foramen, and 3 points on maxilla, such as the contact point of both maxillary central incisors and mesiobuccal cuspal tip of both maxillary first molars, were tracked using an optoelectronic tracking navigation system. The distances before surgery were compared to evaluate the accuracy of the RP model and the distance changes of 3D CT image after surgery were compared with those of the RP model after simulation surgery. Results: A paired t-test revealed a significant difference between the distances in the 3D CT image and RP model before surgery.(P<0.0001) On the other hand, Pearson's correlation coefficient, 0.995, revealed a significant positive correlation between the distances.(P<0.0001) There was a significant difference between the change in the distance of the 3D CT image and RP model in before and after surgery.(P<0.05) The Pearson's correlation coefficient was 0.13844, indicating positive correlation.(P<0.1) Conclusion: Theses results suggest that the simulation surgery of a Le Fort I osteotomy using an optoelectronic tracking navigation system I s relatively accurate in comparing the pre-, and post-operative 3D CT data. Furthermore, the application of an optoelectronic tracking navigation system may be a predictable and efficient method in Le Fort I orthognathic surgery.

Development of Prediction Model for 1-year Mortality after Hip Fracture Surgery

  • Konstantinos Alexiou;Antonios A. Koutalos;Sokratis Varitimidis;Theofilos Karachalios;Konstantinos N. Malizos
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.135-143
    • /
    • 2024
  • Purpose: Hip fractures are associated with increased mortality. The identification of risk factors of mortality could improve patient care. The aim of the study was to identify risk factors of mortality after surgery for a hip fracture and construct a mortality model. Materials and Methods: A cohort study was conducted on patients with hip fractures at two institutions. Five hundred and ninety-seven patients with hip fractures that were treated in the tertiary hospital, and another 147 patients that were treated in a secondary hospital. The perioperative data were collected from medical charts and interviews. Functional Assessment Measure score, Short Form-12 and mortality were recorded at 12 months. Patients and surgery variables that were associated with increased mortality were used to develop a mortality model. Results: Mortality for the whole cohort was 19.4% at one year. From the variables tested only age >80 years, American Society of Anesthesiologists category, time to surgery (>48 hours), Charlson comorbidity index, sex, use of anti-coagulants, and body mass index <25 kg/m2 were associated with increased mortality and used to construct the mortality model. The area under the curve for the prediction model was 0.814. Functional outcome at one year was similar to preoperative status, even though their level of physical function dropped after the hip surgery and slowly recovered. Conclusion: The mortality prediction model that was developed in this study calculates the risk of death at one year for patients with hip fractures, is simple, and could detect high risk patients that need special management.

Maxillo-mandibular Contouring Surgery in Monostotic Fibrous Dysplasia Patients using Simulation Surgery

  • Kim, Dong-Young;You, Myoung-Sang;Ah, Kang-Min
    • Journal of International Society for Simulation Surgery
    • /
    • v.3 no.2
    • /
    • pp.60-63
    • /
    • 2016
  • Fibrous dysplasia is quite a rare disease usually involving maxilla and mandible. Because of its benign clinical course, conservative contouring surgery has been recommended for facial deformity. 3D rapid prototype (RP) model gives a lot of informations before operation such as depth of drilling, area of resection and important anatomic structure. The purpose of this study was to report maxilla-mandibular contouring surgery in fibrous dysplasia patients. A total of 14 consecutive patients were included for surgical and esthetic evaluation. Among 14 patients, RP model study was performed in two patients with severe facial deformity. The other patients underwent contouring surgery under conventional methods. Surgical evaluation was performed with computed tomography scan before and after operation. Surgical resection was successful and patients were satisfied with the surgical results.

Dye-Perfused Human Placenta for Simulation in a Microsurgery Laboratory for Plastic Surgeons

  • Laura C. Zambrano-Jerez;Karen D. Diaz-Santamaria;Maria A. Rodriguez-Santos;Diego F. Alarcon-Ariza;Genny L. Melendez-Florez;Monica A. Ramirez-Blanco
    • Archives of Plastic Surgery
    • /
    • v.50 no.6
    • /
    • pp.627-634
    • /
    • 2023
  • In recent decades, a number of simulation models for microsurgical training have been published. The human placenta has received extensive validation in microneurosurgery and is a useful instrument to facilitate learning in microvascular repair techniques as an alternative to using live animals. This study uses a straightforward, step-by-step procedure for instructing the creation of simulators with dynamic flow to characterize the placental vascular tree and assess its relevance for plastic surgery departments. Measurements of the placental vasculature and morphological characterization of 18 placentas were made. After the model was used in a basic microsurgery training laboratory session, a survey was given to nine plastic surgery residents, two microsurgeons, and one hand surgeon. In all divisions, venous diameters were larger than arterial diameters, with minimum diameters of 0.8 and 0.6 mm, respectively. The majority of the participants considered that the model faithfully reproduces a real microsurgical scenario; the consistency of the vessels and their dissection are similar in in vivo tissue. Furthermore, all the participants considered that this model could improve their surgical technique and would propose it for microsurgical training. As some of the model's disadvantages, an abundantly thick adventitia, a thin tunica media, and higher adherence to the underlying tissue were identified. The color-perfused placenta is an excellent tool for microsurgical training in plastic surgery. It can faithfully reproduce a microsurgical scenario, offering an abundance of vasculature with varying sizes similar to tissue in vivo, enhancing technical proficiency, and lowering patient error.

Indirect Anthropometry on Cast Model of Cleft Lip Nose: Comparison with Direct Anthropometry (구순열비 석고모형에서 간접인체계측법: 직접인체계측법과의 비교)

  • Han, Ki Hwan;Jeong, Hoi Joon;Jin, Hyun Seok;Kim, Jun Hyung;Son, Dae Gu
    • Archives of Plastic Surgery
    • /
    • v.34 no.1
    • /
    • pp.18-23
    • /
    • 2007
  • Purpose: Anthropometry can be divided into two methods, direct anthropometry and indirect anthropometry. The most ideal and accurate method is a direct anthropometry. However, it is difficult to measure in the case of children because of poor cooperation, and it lacks re-productivity. Cast model has advantages of three dimensional featuring, inexpensive and easy fabrication. This study is conducted to find out an accuracy of indirect anthropometry on cast model by comparing it with direct anthropometry. Methods: Total 48 cleft lip nasal deformity patients (unilateral, 40; bilateral, 8) were included in this study. Cast models were made before surgery under general anesthesia with alginate impression material and model plaster. Eleven linear measurements among 7 landmarks were taken as direct anthropometry before surgery with Castroviejo spreading caliper. At the same time, indirect anthropometry on cast model was done at the same linear distances as well. Results: Of the total 11 linear measurements, both ala lengths, both columella lengths, nose width, projective distance between facial insertion points of the ala, projective distance between the alar base points, right nostril floor width, and columella width were statistically correlated between indirect anthropometry on cast model and direct anthropometry. However, the nasal tip protrusion and the left nostril floor width were not statistically correlated. Conclusion: Accuracy of indirect anthropometry on cast model can be influenced by cast model fabrication techniques and correct identification of landmarks. Nasal tip protrusion could be reduced by compression of the nasal tip in the process of cast model fabrication and nostril floor width can be varied by muscle relaxation of anesthetics and incorrect identification of subalare in cleft lip nasal deformity. If sufficient care is taken to make cast model and to define landmarks exactly, indirect anthropometry on cast model can be a reliable method as direct anthropometry.