Man-robot system의 일환으로서 에러회복 전문가시스템에 관한 연구 (A study on an error recovery expert system as a part of man-robot system)

  • 이순요;김창대
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1988년도 한국자동제어학술회의논문집(국내학술편); 한국전력공사연수원, 서울; 21-22 Oct. 1988
    • /
    • pp.518-523
    • /
    • 1988
  • A Teaching and Operating Expert System (TOES) was designed in order to perform a task effectively which is inaccessible to man. Once an error occurs in the middle of the task operation, the automatic mode is converted into a manual mode. After recovering the error by the manual mode, the manual mode should be converted into the automatic mode. It was necessary to improve the manual mode in order to increase the availability of a man-robot system, a part of the human interface technique. Therefore, the Error Recovery Expert System must be constructed and developed.

  • PDF

초소형 전자 렌즈의 전자 광학적 분석 (Electro-optical analysis of a miniaturized electrostatic electron lens)

  • 김호섭;김대욱;김영철;최상국;김대용
    • 한국광학회지
    • /
    • 제14권2호
    • /
    • pp.194-199
    • /
    • 2003
  • FCM(Fast moving least square reproducing kernel point collocation method) 방식의 simulation tool을 이용하여 전기장으로 구동되는 초소형 전자 렌즈의 구동 특성을 조사·분석하였다. Einzel 렌즈의 retarding mode와 accelerating mode구동에서 포텐셜 분포는 유사하지만, electric field strength는 서로 다른 방향을 갖게 되어 서로 다른 형태의 전자 궤적을 보인다. 동일한 working distance에서 accelerating mode로 구동되는 전자렌즈는 retarding mode로 구동되는 경우보다 매우 높은focusing 전압을 필요로 한다.

마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법 (Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid)

  • 박성열;김주하;정아진;최세완
    • 전력전자학회논문지
    • /
    • 제21권3호
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

소규모 분산에너지시스템의 제어구조 및 운전 (마이크로터빈 중심) (Control and Operation of a Small Scale Distributed Energy System)

  • 홍원표;조재훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.1139_1141
    • /
    • 2009
  • Distributed Generation (DG) is predicted to play a important role in electric power system in the near future. insertion of DG system into existing distribution network has great impact on real-time system operation and planning. It is widely accepted that micro turbine generation (MTG) systems are currently attracting lot of attention to meet customers need in the distributed power generation market In order to investigate the performance of MT generation systems, their efficient modeling is required. This paper presents the modeling and simulation of a MT generation system suitable for grid-connected operation. The system comprises of a permanent magnet synchronous generator driven by a MT. A brief description of the overall system is given, and mathematical models for the MT and permanent magnet synchronous generator are presented. Also, the use of power electronics in conditioning the power output of the generating system is demonstrated. Simulation studies with MATLAB/Simulink have been carried out in grid-connected operation mode of a DG system. The control strategies for grid connected operation mode of DG system is also presented.

  • PDF

가변 스텝 사이즈를 적용한 P&O 방식 기반의 고효율 MPPT 알고리즘 연구 (A Study on High-Efficiency MPPT Algorithm Based on P&O Method with Variable Step Size)

  • 김봉석;정가준;심우식;조종민;차한주
    • 전력전자학회논문지
    • /
    • 제24권1호
    • /
    • pp.1-8
    • /
    • 2019
  • In this study, a maximum power point tracking (MPPT) algorithm based on the perturb and observe (P&O) method with variable step size is proposed to improve the dynamic response characteristic of MPPT, using the existing P&O method. The proposed algorithm, which we verified by simulation and experiment, can track the maximum power point (MPP) through duty control and consisted of three operation modes, namely, constant voltage mode, fast mode, and variable step mode. When the insolation is constant, the voltage variation of the operating point at the MPP is reduced through the step size reduction of the duty in the variable step mode. Consequently, the vibration of the operating point is reduced, and the power generation efficiency is increased. When the insolation changes, the duty and the photovoltaic (PV) voltage are kept constant through the constant voltage mode. The operating point then rapidly tracks the new MPP through the fast-mode operation at the end of the insolation change. When the MPP is reached, the operation is changed to the variable step mode to reduce the duty step size and track the MPP. The validity of the proposed algorithm is verified by simulation and experiment of a PV system composed of a PV panel and a boost converter.

필드로봇용 원격 굴삭 시스템의 궤적제어에 관한 연구 (A Study on Tracking Control of Remote Operated Excavator for Field Robot)

  • 양순용;진성민;최정주;이창돈;김용석
    • 유공압시스템학회논문집
    • /
    • 제6권4호
    • /
    • pp.9-15
    • /
    • 2009
  • Hydraulic excavators are the representative of field robot and have been used in various fields of construction. Since the excavator operates in the hazardous working environment, operators of excavator are exposed in harmful environment. Therefore, the hydraulic excavator automation and remote operation system has been investigated to protect from the hazardous working environment. In this paper, remote operation excavator system is developed using the mini hydraulic excavator and the tracking control system of each links of excavator is designed. To apply the tracking control system, the adaptive sliding mode control algorithm is proposed. It is found that the performance of the proposed control system is improved through experimental results of using the remote operation excavator system.

  • PDF

IEEE 802.16e 시스템에서 이동 단말의 에너지 절약 기법 (Power Saving Scheme for MS in IEEE 802.16e system)

  • 심유승;강재은;이정규
    • 한국통신학회논문지
    • /
    • 제34권4B호
    • /
    • pp.319-328
    • /
    • 2009
  • IEEE 802.16e 표준에서는 이동 단말의 제한된 에너지를 효율적으로 관리하기 위하여 서비스의 종류에 따라 서로 다른 수면모드 작동기법을 정의하고 있다. 기존의 수면모드 작동기법에 대한 연구는 이동 단말이 하나의 서비스를 받는 환경으로 제한되어 있으므로, 여러 서비스를 동시에 받을 경우 서로 다른 수면모드 작동기법을 동시에 적용하여 실제로 에너지를 절약하는 구간을 크게 감소시킨다. 본 논문에서 제안하는 에너지 절약 기법은 이동 단말이 여러 서비스를 동시에 받는 환경에서 실제로 에너지를 절약하는 구간을 증가시킴으로써, 에너지 소모를 최소화하고 기존과 비슷한 수준의 QoS(Quality of Services)를 보장한다. 향후 IEEE 802.16e 시스템에서 이동 단말의 제한된 배터리 수명을 증가시키면서 QoS를 보장하고 싶을 경우, 본 논문에서 제안한 에너지 절약 기법이 유용하게 사용될 수 있을 것이다.

입력전압을 감지하지 않는 전류연속/임계동작모드 Active Power Factor Correction Circuit (A Continuous Conduction mode/Critical Conduction Mode Active Power Factor Correction Circuit with Input Voltage Sensor-less Control)

  • 노용성;유창식
    • 전자공학회논문지
    • /
    • 제50권8호
    • /
    • pp.151-161
    • /
    • 2013
  • 본 논문에서는 입력전압을 감지하지 않는 전류연속/임계동작모드 active power factor correction(PFC) circuit을 제안하였다. 기존의 입력전압을 감지하지 않는 PFC circuit의 경우 출력전류가 낮은 경 부하 조건에서 DCM 동작을 수행하고, 이에 따라 PF가 감소하는 문제가 발생한다. 제안한 PFC circuit은 70KHz의 주파수로 CCM 동작을 수행하고, 경 부하 조건에서 최대 200KHz까지 스위칭 주파수가 가변되는 CRM 동작을 수행하도록 하였다. 이를 통해 경 부하 조건에서 PF가 감소하는 문제를 해결하였다. PFC controller IC는 $0.35{\mu}m$ BCDMOS 공정을 이용하여 제작하였으며, 240W급 PFC prototype을 제작하여 실험하였다. 제안한 PFC circuit은 기존의 PFC circcuit 대비 최대 10%의 역률이 향상되었고, IEC 61000-3-2 Class D 규격에 따른 경 부하 조건에서는 최대 4% 역률이 향상되었다.

ACCELEROMETER SELECTION CONSIDERATIONS Charge and Integral Electronic Piezo Electric

  • Lally, Jim
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.1047-1051
    • /
    • 2004
  • Charge amplifier systems benefit from the very wide dynamic range of PE accelerometers by offering flexibility in adjusting the electrical output characteristics such as sensitivity and range. They are well suited for operation at high temperatures. Modern charge systems feature improved low noise operation, simplified digital controls, and dual mode operation for operation with charge or IEPE voltage mode sensors. high impedance circuitry is not well suited for operation in adverse field or factory environments. The resolution of a PE accelerometer may not be specified or known since noise is a system consideration determined by cable length and amplifier gain. IEPE accelerometrs operate from a constant current power source, provide a high-voltage, low-impedance, fixed mV/g output. They operate through long, ordinary, coaxial cable in adverse environments without degradation of signal quality. They have limited high temperature range. IEPE sensors are simple to operate. Both resolution and operating range are defined specifications. Cost perchannel is lower compared to PE systems since low-noise cable and charge amplifiers are not required.

  • PDF

Compound-Type Hybrid Energy Storage System and Its Mode Control Strategy for Electric Vehicles

  • Wang, Bin;Xu, Jun;Cao, Binggang;Li, Qiyu;Yang, Qingxia
    • Journal of Power Electronics
    • /
    • 제15권3호
    • /
    • pp.849-859
    • /
    • 2015
  • This paper proposes a novel compound-type hybrid energy storage system (HESS) that inherits the unique advantages of both battery/supercapacitor (SC) and the SC/battery HESSs for electric vehicles (EVs). Eight operation modes are designed to match this system. A mode control strategy is developed for this HESS on the basis of these modes, and five classes of operation modes are established to simplify this strategy. The mode control strategy focuses on high operating efficiency and high power output. Furthermore, the compound-type HESS is designed such that the SC is the main priority in braking energy absorption. Thus, this HESS can operate efficiently and extend battery life. Simulation results also show that the compound-type HESS can not only supply adequate power to the motor inverter but can also determine suitable operation modes in corresponding conditions. Experimental results demonstrate that this HESS can extend battery life as well. The overall efficiency of the compound-type HESS is higher than those of the battery/SC and the SC/battery HESSs.