• Title/Summary/Keyword: Mode Share

Search Result 113, Processing Time 0.026 seconds

Exploration to Model CSCL Scripts based on the Mode of Group Interaction

  • SONG, Mi-Young;YOU, Yeong-Mahn
    • Educational Technology International
    • /
    • v.9 no.2
    • /
    • pp.79-95
    • /
    • 2008
  • This paper aims to investigate modeling scripts based on the mode of group interaction in a computer-supported collaborative learning environment. Based on a literature review, this paper assumes that group interaction and its mode would have strong influence on the online collaborative learning process, and furthermore lead learners to create and share significant knowledge within a group. This paper deals with two different modes of group interaction- distributed and shared interaction. Distributed interaction depends on the external representation of individual knowledge, while shared interaction is concerned with sharing knowledge in group action. In order to facilitate these group interactions, this paper emphasizes the utilization of appropriate CSCL scripts, and then proposes the conceptual framework of CSCL scripts which integrate the existing scripts such as implicit, explicit, internal and external scripts. By means of the model regarding CSCL scripts based on the mode of group interaction, the implications for research on the design of CSCL scripts are explored.

Power Sharing Method for a Grid connected Microgrid with Multiple Distributed Generators

  • Nguyen, Khanh-Loc;Won, Dong-Jun;Ahn, Seon-Ju;Chung, Il-Yop
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.4
    • /
    • pp.459-467
    • /
    • 2012
  • In this paper, a grid connected microgrid with multiple inverter-based distributed generators (DGs) is considered. DG in FFC mode regulates the microgrid as a controllable load from the utility point of view as long as its output is within the capacity limit. The transition mode causes a change in frequency of microgrid due to the loss of power transferred between main grid and microgrid. Frequency deviation from the nominal value can exceed the limit if the loss of power is large enough. This paper presents a coordinated control method for inverter-based DGs so that the microgrid is always regulated as a constant load from the utility viewpoint during grid connected mode, and the frequency deviation in the transition mode is minimized. DGs can share the load by changing their control modes between UPC and FFC and stabilize microgrid during transition.

A Fuel Cell Generation System with a New Active Clamp Sepic-Flyback Converter

  • Lee, Won-Cheol;Jang, Su-Jin;Kim, Soo-Seok;Lee, Su-Won;Won, Chung-Yuen
    • Journal of Power Electronics
    • /
    • v.9 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • A high efficiency active clamp sepic-flyback converter is presented for fuel cell generation systems. The proposed converter is a superposition of a sepic converter mode and. flyback converter mode. The output voltages of the sepic converter mode and flyback converter mode can be regulated by the same PWM technique with constant frequency. By merging the sepic and flyback topologies, they can share the transformer, power MOSFET and active clamp circuit. The result has outstanding advantages over conventional active clamp DC-DC converters: high efficiency, high power density, and component utilization. Simulation results and experimental results are presented to verify the principles of operation for the proposed converter.

Parallel Operation Control Method of Grid-connected Inverters with Seamless Transfer for Energy Storage System in Microgrid (마이크로그리드에서 에너지 저장시스템을 위한 무순단 절체 기능을 갖는 계통연계형 인버터의 병렬운전 제어기법)

  • Park, Sung-Youl;Kim, Joo-Ha;Jung, Ah-Jin;Choi, Se-Wan
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.3
    • /
    • pp.200-206
    • /
    • 2016
  • In the microgrid, inverters for energy storage system are generally constructed in a parallel structure because of capacity expandability, convenience of system maintenance, and reliability improvement. Parallel inverters are required to provide stable voltage to the critical load in PCC and to accurately share the current between each inverter. Furthermore, when islanding occurs, the inverters should change its operating mode from grid-connected mode to stand-alone mode. However, during clearing time and control mode change, the conventional control method has a negative impact on the critical load, that is, severe fluctuating voltage. In this study, a parallel operation control method is proposed. This method provides seamless mode transfer for the entire transition period, including clearing time and control mode change, and has accurate current sharing between each inverter. The proposed control method is validated through simulation and experiment.

Implementation of Current Mode Control using Current Balance Controller of Multi-Phase Interleaved Boost Converter (다상 교호 승압컨버터의 전류평형제어기를 이용한 전류모드제어기 구현)

  • Park, Jong-Gyu;Choi, Hyun-Chil;Shin, Hwi-Beom
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.157-163
    • /
    • 2008
  • In the multi-phase interleaved converter with peak current mode control, current imbalance is measured when inductors of converter module are not exactly identical. In this paper current-sharing controller is proposed to balance phase current of converter modules. It also is designed to have good transient response. Proposed method implemented the 2-phase and 4-phase interleaved boost converter with imbalanced inductance. Experimental results verify the performance of Current share during the transient state of converter.

A Mode Choice Model with Market Segmentation of Beneficiary Group of New Transit Facility (신교통수단 수혜자의 시장분할을 고려한 수단선택 모형 개발)

  • Kim, Duck Nyung;Choi, A Reum;Hwang, Jae-Min;Kim, Dong-Kyu
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.33 no.2
    • /
    • pp.667-677
    • /
    • 2013
  • The introduction of a new transit facility affects mode share of travel alternatives. The multinomial logit model, which has been the most commonly used for estimating mode share, has difficulty in reflecting heterogeneity of travelers' choices, and it has a limitation on grasping their characteristics of mode choice. The limitation may lead to over- or under-estimation of the new transit facility and bring about significant social costs. This paper aims to find a methodology to overcome the problem of preference homogeneity. It also applies market segmentation structure of separating the whole population into direct and indirect beneficiary to consider their preference heterogeneity. A mode choice model is estimated on data from Jeju Province and statistically tested. The results show that mode transfer rate of direct beneficiaries that inhabit in downtown areas increases as the new transit facility provides more advanced services with higher costs. The results and the model suggested in this study can contribute to improving the accuracy of demand forecasting of new transit facilities by reflecting heterogeneity of mode-transfer patterns.

Preparation and Oxygen Binding Properties of Ultra-Thin Polymer Films Containing Cobalt(II) meso-Tetraphenylporphyrin via Plasma Polymerization

  • Choe, Youngson
    • Macromolecular Research
    • /
    • v.10 no.5
    • /
    • pp.273-277
    • /
    • 2002
  • Ultra-thin polymer films containing cobalt(II) meso-tetraphenylporphyrin(CoTPP) have been prepared by vacuum codeposition of the metal complex and trans-2-butene as an organic monomer using an inductively coupled RF glow discharge operating at 7-9 Watts. The polymer films were characterized by sorption measurements. Sorption data obtained for polymer films containing CoTPP indicate that the CoTPP molecules are capable of reversibly binding oxygen molecules. It was found that the adjacent CoTPP molecules in the aggregated metal complex phase could irreversibly share the oxygen molecules. A dispersion of the metal complex molecules in the polymer matrix was made to maintain the reversible reactivity of the metal complex molecules with oxygen in the polymer films via vacuum evaporation process. The Henry mode solubility constant, the Langmuir mode capacity constant, the amount of binding oxygen, and the dissociation equilibrium in the dual mode sorption theory were discussed.

Introduction to Knobology Focusing on B Mode and Doppler Setting in Musculoskeletal Ultrasound (근골격계 초음파의 기판 조절 입문: B Mode와 Doppler)

  • Min, Kyunghoon
    • Clinical Pain
    • /
    • v.20 no.1
    • /
    • pp.7-14
    • /
    • 2021
  • Musculoskeletal ultrasound has evolved as the essential tool to diagnose and guide intervention procedures in people with neuromusculoskeletal conditions. Image optimization and understanding device operations are core components for ultrasound guided intervention procedure training. All ultrasound machines share the common operative features and there are various buttons for the features in the device control panel. Ultrasound "knobology" refers to the thorough understanding of imaging optimization. This review addressed basic information for the transducers, depth setting, gain and focus control, different modes focusing on brightness and doppler modes.

A Study on the Planning Strategy of Tenant Variety and Placement for Urban Entertainment Center (도심 쇼핑센터(UEC)의 테넌트 구성 및 배치계획에 관한 연구)

  • Lee, Hyun-Soo;Oh, Jung-Ah
    • Korean Institute of Interior Design Journal
    • /
    • v.21 no.2
    • /
    • pp.174-185
    • /
    • 2012
  • The purpose of this study is to suggest planning strategy of tenant mix for UEC based on the final result of tenant mix analysis of five different research cases. The following is the comprehensive explanation about the result of tenant mix planning strategy for UEC currently in operation and when planning a new facility. First, overall research cases in this study show the tendency of following an old tradition, which stresses direct sales focusing on retail and dining adaptation. In order to compensate the defect, it is suggested to adopt new type of tenants with the functional mix of retail and dining with entertainment rather than decreasing the proportion of retail and dining tenant and increasing it of entertainment tenant. Second, the floorplan of UEC should adopt racetrack or circuit form that can stimulate shoppers' circular movement so to expose them to as much tenants as possible. Service consumption mode related tenants are required to place on the side or the edge of UEC, while retail consumption mode related tenants should be planned in the center. Among dining consumption mode related tenants, impulse dining tenants like a coffee shop should be placed at the turning point or at the end of the pathway, destination tenants like a restaurant and a food court, on the other hand, is needed to be placed in the center of the space. In case of Entertainment related tenants, destination tenants like bookstore or multiplex should also be placed at the end of the pathway, and on the way to those tenants, it is required to place general tenants that can share target customers with them. On the contrary, game center or record shop like tenants that can stimulate impulse sales should be placed on the visitor's main move or near the other destination tenants. Third, anchor tenants play an important role in gathering people to the UEC, and then induce them to visit the other tenants that are located near the anchors. Thus it is suggested to plan to place general tenants on the same floor as anchor tenants are placed so they can share the characteristics of target customers which create synergy effect.

  • PDF

Parallel Operation Characteristics of Utility Interactive Photovoltaic System and Revolving Field Type Synchronous Generator (계통연계 태양광발전시스템과 회전계자형 동기발전기의 병렬운전 특성)

  • Ryu, Yeon-Soo;Yoo, Wang-Jin;Lee, Checl-Gyu;Moon, Jong-Beom
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2008.04a
    • /
    • pp.43-48
    • /
    • 2008
  • Through simulations and field experiment on A.C. parallel operation of both Utility Interactive Photovoltaic System and Diesel Engine Revolving Field Type Synchronous Generator, following factors have been found. First, the inverter should be operated in three modes of frequency(mode.1: ${\pm}$0.3Hz, mode.2: ${\pm}$1Hz, mode.3: ${\pm}$2Hz) as default, considering properties of operating Synchronous Generator. Second, as a result of supplying 13.5kW of residual power, it has been found that Synchronous Generator takes the power input only as reactive power, because it was electrically stable with frequency of 60.14Hz and high voltage of 222.3V even when power factor was -0.94. Besides, it was mechanically stable, too, because the quake, noise, and temperature of Synchronous Generator in this case were 7.5mm/s, 97dB, and $6^{\circ}C$ respectively, which were lower than normal load connection of 145.6kW; 11.03mm/s. Thus, load share of Revolving Field Type Synchronous Generator reduces according to the supply of Photovoltaic System to the load power. In this experiment, 200kW of Synchronous Generator and 40kW of Photovoltaic System were operated in parallel. The load share was 20% in maximum. and 11.1lit/hr of fuel was saved.

  • PDF