• Title/Summary/Keyword: Mode & Exception

Search Result 24, Processing Time 0.02 seconds

SHADE ANALYSIS OF ANTERIOR TEETH USING DIGITAL SHADE ANALYSIS SYSTEM (Digital Shade Analysis System을 이용한 전치부의 색조 특성에 관한 연구)

  • Kim Hee-Eun;Cho In-Ho;Lim Ju-Hwan;Lim Hun-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.5
    • /
    • pp.565-581
    • /
    • 2003
  • Statement of problem : A scientific examination and understanding of overall aspects of the natural dentition is the first step involved in making a satisfactory selection in the shade of an aesthetic prosthesis. Proper natural shade selection of the prosthetic restoration that is in harmony with the remaining dentition is as important aesthetically, as harmony of form and function in the anterior dentition. Clinically, the most commonly applied method of shade selection has been visual, but because of the subjective nature inherent to this method, shade selection results are variable and can be influenced by such factors as the technician, the type of shade guide used, and the type and intensity of the lighting. Purpose : The purpose of this study was to develop a more objective and scientific approach to examining and understanding the shade of teeth, which has in turn lead to the development of a number of shade analysis devices that present a more objective method of shade analysis. Material and Method : In this study, the shades of healthy anterior teeth were examined and analyzed using the recently developed digital shade analysis of the $ShadeScan^{TM}$ System. The study examined 80 individuals in their twenties, 40 males and 40 females, presenting 6 healthy, unrestored maxillary anterior teeth. Tooth brushing and oral prophylaxis were performed prior to evaluation. The ShadeScan handpiece was used to acquire images of the 6 maxillary anterior teeth. These images were analyzed using the Vita/Classical mode of the $ShadeScan^{TM}$ Software, and shade maps of each tooth were acquired and divided into cervical, middle, and incisal thirds. The shade distribution of each third, left and right symmetry, and gender differences were investigated and analyzed. Results : The results of the study are as follows : 1. An overwhelming majority of the examined teeth were found to possess shades belong to Group A, with the greatest variations occurring at the middle and cervical thirds of the maxillary central and lateral incisors, in both male and female subjects. 2. Canines of both male and female subjects showed left and right symmetry with uniform shade distribution of A4 and C4, while the lateral and central incisors showed left-right symmetry of the incisal 1/3 with a uniform shade distribution of A2 and A3 shades 3. No significant differences in shade distribution were seen between genders in maxillary canines, whereas maxillary central and lateral incisors showed differences at the middle and cervical thirds between male and female subjects The results of this study show that with the exception of maxillary canines, maxillary anterior teeth display a diverse shade distribution as well as gender differences. Conclusion : Clinically, when making a shade selection using the existing shade guide, one must consider the fact that even a single tooth consists of a variety of shades. The results of this study show that when selecting a shade from a number of groups is difficult, shades from A group are the most consistent with the natural shade or maxillary anterior teeth.

Implementation of Nested Software Interrupt and Passing Way of Parameters based on ARM9 (ARM9기반의 Nested Software Interrupt의 구현 및 Parameter의 전달 방식)

  • Han, Gil-Jong;Lew, Kyeung-Seek;Lee, Jung-Won;Kim, Yong-Deak
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.48 no.5
    • /
    • pp.66-73
    • /
    • 2011
  • I try to solve the problem of the usage of the general software interrupt with the nested call of the software interrupt and the effective passing way of the parameters. The software interrupt should be protected against the indiscriminate access because it is used to call the system functions or to use the system resources by generating a software interrupt. But, it is difficult to effectively handle the SWI instruction because of its limited usage. I designed and implemented nested call of the software interrupt and the effective way that handle the parameters in the software interrupt service routine to solve this problem in this paper. In other words, from the single SWI call to the nested SWI call, I improved the software interrupt use all the more flexibly, and I compared and analyzed the strong and weak points of the two passing ways of the parameters. The main differences between these two ways are speed and readability. The stack pointer getting way incurred a lot of overhead although it has a very great readability. But, the stack pointer passing way producted 19% of the effectivity in speed by reduce overhead.

A study on Air and High Speed Rail modal According to the Introduction of Low Cost Carrier Air Service (저비용항공 진입에 따른 항공과 고속철도수단 선택에 관한 연구)

  • Lim, Sam-Jin;Lim, Kang-Won;Lee, Young-Ihn;Kim, Kyung-Hee
    • Journal of Korean Society of Transportation
    • /
    • v.26 no.4
    • /
    • pp.51-61
    • /
    • 2008
  • Most of Korea's 15 local airports, with the exception Jeju, Gimpo and Gimhae airports, have been several billion Won in the red each year. It has been reported that one of the causes of the poor financial performance is inaccurate air traffic demand predictions. Under the situation, the entry of low-cost carrier air service using turbo-prop airplanes into the domestic airlines market gets a wide range of support, which is expected to promote the convenience of consumers and help to activate local airports. In this study, the authors (1) suggest a high-speed transport demand model among existing airlines, Korea Train Express (KTX) and low-cost carrier air service; (2) try to make low-cost air carrier demand predictions for a route between Seoul and Daegu through a stated-preference survey; and (3), examine possible effectiveness of selected policy measures by establishing an estimation model. First, fare has a strong influence for mode choice between high-speed transport modes when considering the entry of low-cost carrier air service between Seoul and Daegu. Even low-cost carrier air service fare is set at 38,000 won, which is considerably low compared with that of KTX, in the regions where the total travel time is the same for both low-cost carrier air service and KTX, the probability of selecting low-cost carrier air service is 0.1, which shows little possibility of modal change between high speed transportation means. It is suggested that the fare of low-cost air service between Seoul and Daegu should be within the range of from of 38,000 to 44,000 Won; if it is higher, the demand is likely to be lower than expected.

Dentin bond strength of bonding agents cured with Light Emitting Diode (LIGHT EMITTING DIODE로 광조사한 상아질 접착제의 상아질 전단접착강도와 중합률에 관한 연구)

  • Kim Sun-Young;Lee In-Bog;Cho Byeong-Hoon;Son Ho-Hyun;Kim Mi-Ja;Seok Chang-In;Um Chung-Moon
    • Restorative Dentistry and Endodontics
    • /
    • v.29 no.6
    • /
    • pp.504-514
    • /
    • 2004
  • This study compared the dentin shear bond strengths of currently used dentin bonding agents that were irradiated with an LED (Elipar FreeLight, 3M-ESPE) and a halogen light (VIP, BISCO). The optical characteristics of two light curing units were evaluated. Extracted human third molars were prepared to expose the occlusal dentin and the bonding procedures were performed under the irradiation with each light curing unit. The dentin bonding agents used in this study were Scotchbond Multipurpose (3M ESPE), Single Bond (3M ESPE), One-Step (Bisco), Clearfil SE bond (Kuraray), and Adper Prompt (3M ESPE), The shear test was performed by employing the design of a chisel-on-iris supported with a Teflon wall. The fractured dentin surface was observed with SEM to determine the failure mode. The spectral appearance of the LED light curing unit was different from that of the halogen light curing unit in terms of maximum peak and distribution. The LED LCU (maximum peak in 465 nm) shows a narrower spectral distribution than the halogen LCU (maximum peak in 487 nm). With the exception of the Clearfil SE bond (P < 0.05), each 4 dentin bonding agents showed no significant difference between the halogen light-cured group and the LED light-cured group in the mean shear bond strength (P > 0.05). The results can be explained by the strong correlation between the absorption spectrum of camphoroquinone and the narrow emission spectrum of LED.