Sound Spectral Analysis of Valvular Clicks of Thrombosed Valve Prostheses (혈전이 발생한 인공판막의 판막음 스펙트럼 분석)

  • Kim, S.H.;Chang, B.C.;Tack, G.;Huh, J.M.;Kim, N.H.;Kang, M.S.;Cho, B.K.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1994 no.05
    • /
    • pp.105-108
    • /
    • 1994
  • A comparative study was made of the valvular sounds produced by normal prosthetic valves with thrombosed prosthetic valves. Comparisons of the closing sound were made for the power frequency spectra associated with individual valves. We used periodogram approach to obtain the spectral characteristics of the valve. Spectral analysis system was tested in mock circulatory system by comparing normal valves with those produced by the same valves but having simulated thrombosis at the hinge of the valve. The heart sounds was recorded from two patients having normal mechanical valve and thrombosed mechanical valve. The estimated spectrum of the thrombosed mechanical valve displayed lower apparent peak frequency than that of the normal valve. The results showed that frequency spectra gave information pertinent to the valve malfunction. Sound spectral analysis is simple and alternative diagnostic tool for early detection of prosthetic valve mal function.

  • PDF

The Development of a New Polymer Valve for Artificial Blood Pumps (인공심장 및 심실보조장치용 고분자 인조판막의 개발)

  • Suh, S.W.;Wetering, J.E.v.d.;Park, Y.J.;Park, S.K.;Kim, I.Y.;Min, B.G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1993 no.11
    • /
    • pp.104-106
    • /
    • 1993
  • Some cardio-vascular assist systems need more inexpensive artificial heart valves for short-term use. To meet with this need, we have developed a new polymer valve that is very simple to manufacture and of which its dimensions are easy to change, depending on its application. We have tested the hydrodynamic performance of the new polymer valve using a mock circulatory testing system and studied the flow through the valve using high-speed camera combined with image processing techniques. The results show that this valve is superior in its performances to the other valves (Bjork-Shiley mechanical valve and trileaflet polymer valve) and have no stagnation points. We also have tested the hemolytic potential of the valve. The valve is less hemolytic than the Bjork-shiley mechanical valve finally, we have applied this valve to a left ventricular assist device that we are developing.

  • PDF

Development of A Biotelemetry System for A Totally Implantable Artificial Heart (완전이식 인공심장용 무선정보 전송장치의 개발)

  • Choi, Won-Woo;Kang, Dong-Woo;Park, Seong-Keun;Choi Jae-Soon;Kim, Hee-Chan;Min, Byoung-Goo
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.1
    • /
    • pp.57-66
    • /
    • 1996
  • In this paper, a new biotelemetry system for a transcutaneous data communication between an implanted artificial heart with a control system and an external human-interfaced management system has been developed. A radio telemetry using radio frequency is a commonly used method in the conventional telemetry systems. But, it is not suitable for the medical applications because of not only an interference due to a radio broadcasting but also a harmfulness to the human body. In this paper, therefore, a new biotelemetry system applied to an artificial heart has been developed with the results of the recent research for an optical telemetry system based on the infrared light transmission with good skin permeability. The performance of the biotelemetry system developed has been assessed through mock circulatory experiments, and the clinical applicability has been also confirmed with the successful results in the animal experiments.

  • PDF

Study on Electrically Powered Left Ventricular Circulation Assist Device (좌심실 전동순환 보조장치에 관한 연구)

  • Kim, Myoung-Nam;Lee, Jeong-Woo;Chang, Bong-Hyun;Cho, Jin-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.1
    • /
    • pp.51-60
    • /
    • 2000
  • This paper outlines the development of a non-pulsatile axial flow type blood pump control system. By utilizing blood pressure and heart rate, this system can assist the left ventricle in controlling blood pressure and blood volume. The system is comprised of a blood pump, signal sensor, signal interface, and signal-processing component. A control algorithm is also proposed which can control non-pulsatile, continuous blood flow in the human circulatory system. To facilitate the control required for non-pulsatile blood pump in a physiological system, an experimental control rule was developed utilizing ECG and blood pressure data, both of which are easily detectable variables in the body. The system was then tested using a mock-up circulation system and we found that it is possible that this systems could be temporarily used in clinic.

  • PDF

Automatic Control System on Cardiac Output Regulation for the Moving Actuator Type Total Artificial Heart (MOVING-ACTUATOR TYPE 인공심장의 심박출 조절에 대한 자동 제어방법)

  • 김원곤
    • Journal of Chest Surgery
    • /
    • v.28 no.6
    • /
    • pp.542-548
    • /
    • 1995
  • The goal of this study is to develop an effective control system for cardiac output regulation based upon the preload and afterload conditions without any transducers and compliance chambers in the moving actuator type total artificial heart. Motor current waveforms during the actuator movement are used as an input to the automatic control algorithm. While the current waveform analysis is performed, the stroke length and velocity of the actuator are gradually increased up to the maximum pump output level. If the diastolic filling rate of either right or left pump begins to exceed the venous return, atrial collapse will occur. Since the diastolic suction acts as a load to the motor, this critical condition can be detected by analyzing the motor current waveforms. Every time this detection criterion is met, the control algorithm decreases the stroke velocity and length of the actuator step by step just below the critical detection level. Then, they start to increase. In this way the maximum pump output under given venous return can be achieved. Additionally the control algorithm provides some degree of afterload sensitivity. If the aortic pressure is detected to exceed 120 mmHg, the stroke length and velocity decrease in the same way as the response to the preload. Left-right pump output balance is maintained by proper adjustment of the asymmetry of the stroke angle. In the mock circulatory test, this control system worked well and there was a considerable range of stroke volume difference with adjustment of the asymmetry value. Two ovine experiments were performed. It was confirmed that the required cardiac output regulation according to the venous return could be achieved with adequate detection of diastolic function, at least in the in vivo short-term survival cases[2-3 days . We conclude that this control algorithm is a promising method to regulate cardiac output in the moving actuator type total artificial heart.

  • PDF

An Experimental Study on the Analysis of the Interventricular Pressure Waveform in the Moving-Actuator type Total Artificial Heart (이동작동기식 완전 이식형 인공 심장의 심실간 공간 압력 파형 해석에 관한 실험적 연구)

  • 조영호;최원우
    • Journal of Biomedical Engineering Research
    • /
    • v.18 no.1
    • /
    • pp.25-36
    • /
    • 1997
  • To regulate cardiac output of the Total Artificial Heart(TAH) physiologically, the hemodynamic information must be toed back to the controller. So far, our group has developed an automatic cardiac output control algorithm using the motor current waveform, It is, however difficult to detect the preload level such as a filling status of ventricular inflow and the variation of atrial pressures within normal physiologic range(0-15 mmHg) by analyzing the motor current which simultaneously reflects the afterload effect. On the other hin4 the interventricular volume pressure(IVP) which is not influenced by arterload but by preload is a good information source for the estimation of preload states. In order to find the relationship between preload and IVP waveform, we set up the artificial heart system on the Donovan type mock circulatory system and measured the IVP waveform, right and left atrial pressures, inflow and outflow waveforms and the signals represented the information of moving actuator's position. We shows the feasibility of estimating the hemodynamic changes of inflow by using IVP waveform. fife found that the negative peak value of IVP waveform is linearly related to atrial pressures. And we also found that we could use the time to reach the negative peak in IVP waveform, the time to open outflow valve, the area enclosed IVP waveform as unfu parameters to estimate blood filling volume of diastole ventricle. The suggested method has advantages of avoiding thrombogenesis, bacterial niche formation and increasing longterm reliability of sensor by avoiding direct contact to blood.

  • PDF

Blood Flow and Pressure Evaluation for a Pulsatile Conduit-Shaped Ventricular Assist Device with Structural Characteristic of Conduit Shape (관형의 구조적 특징을 갖춘 박동형 관형 심실보조장치의 혈류, 혈압 평가)

  • Kang, Seong-Min;Choi, Seong-Wook
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.35 no.11
    • /
    • pp.1191-1198
    • /
    • 2011
  • The use of a ventricular assist device (VAD) can raise the one-year survival rate without cardiac transplantation from 25% to 52%. However, malfunction of the VAD system causes 6% of VAD patients' deaths, which could possibly be avoided through the development of new VADs in which VAD malfunctions do not affect the patient's heart movement or hemodynamic state. A conventional VAD has an impeller or vane for propelling blood that can allow blood to regurgitate when the propelling force is weaker than the aortic pressure. In this paper, we developed a new pulsatile conduit-shaped VAD that has two valves. This device removes the possibility of blood regurgitation and has a small stationary area even when the pumping force is extremely weak. We estimated the characteristics of the device by measuring the outflow and the pressure of the pump in in-vitro and in-vivo experiments.

Development of the Control Algorithm for Counterpulsation between a Moving-actuator type Bi-Ventricular Assist Device (AnyHeart) and a Natural Heart (한국형 심실 보조 인공심장과 자연심장 간의 counterpulsation 제어 알고리즘의 개발)

  • Nam, Kyoung Won;Choi, Seong Wook;Chung, Jinhan;Kim, Wook Eun;Min, Byoung Goo
    • Journal of Biomedical Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.33-38
    • /
    • 2002
  • A Ventricular Assist Device(YAD) is used to support the injured natural heart So. when considering a control algorithm for YAD. it is important to reduce a natural heart's load to enhance its recovery condition. To reduce natural heart's load, a counterpulsation algorithm is used commonly. In this study, we developed a counterpulsation control algorithm for moving-actuator type VAD and tested its usefulness using in vitro MOCK circulatory system. To notice a natural heart's Pumping status, electrocardiogram(ECG) signal was used and as a result of test. the counterpulsation effect between YAD and a natural heart was occurred and Automatic Control Mode Transition was occurred properly.

A Study on the Direction of Developing a Simulator for Performance Evaluation of Pulse Wave Detectors Through a Review of the Development Status of Cardiovascular Simulators (심혈관계 시뮬레이터 개발 동향 분석을 통한 맥파검사용기기 성능평가 시뮬레이터 연구개발 방향 모색)

  • Lee, Ju-Yeon;Kim, Jaeyoung;Go, Dong-Hyun;Lee, Ji-Won;Lee, Tae-Hee;Park, Chang-Won;Lee, Su-Kyoung
    • Journal of Biomedical Engineering Research
    • /
    • v.43 no.3
    • /
    • pp.136-146
    • /
    • 2022
  • In this study, it is intended to provide basic data that can help develop a cardiovascular simulator for performance evaluation of pulse wave detectors by identifying the development status of domestic and overseas cardiovascular simulators. A total of 119 papers were selected by excluding duplicate literature, gray literature, and literature not related to a cardiovascular simulator. Based on the selected literature, the research trend of cardiovascular simulators was analyzed. As a result of analyzing the purpose of the study, most of the simulators were developed to evaluate the hemodynamic properties of artificial hearts and valves. In addition, it was used for simulation evaluation or hemodynamic studies such as pulse wave studies. As a result of analyzing configurations of the simulators, a heart most often consisted of only one left ventricle. For blood vessels, the Windkessel model was most often constructed using chambers and valves. In most studies, blood was reproduced by mixing glycerin and water to reproduce both density and viscosity. In addition, as a result of analysis from the perspective of medical device performance evaluation, simulators for evaluating artificial heart and artificial valves have been studied a lot, whereas simulators for blood pressure, pulse wave, and blood flow devices have been relatively insignificant. Based on the review results, we suggested considerations when developing a simulator for performance evaluations of a pulse wave detector.

Computer Aided Diagnosis System for Evaluation of Mechanical Artificial Valve (기계식 인공판막 상태 평가를 위한 컴퓨터 보조진단 시스템)

  • 이혁수
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.5
    • /
    • pp.421-430
    • /
    • 2004
  • Clinically, it is almost impossible for a physician to distinguish subtle changes of frequency spectrum by using a stethoscope alone especially in the early stage of thrombus formation. Considering that reliability of mechanical valve is paramount because the failure might end up with patient death, early detection of valve thrombus using noninvasive technique is important. Thus the study was designed to provide a tool for early noninvasive detection of valve thrombus by observing shift of frequency spectrum of acoustic signals with computer aid diagnosis system. A thrombus model was constructed on commercialized mechanical valves using polyurethane or silicon. Polyurethane coating was made on the valve surface, and silicon coating on the sewing ring of the valve. To simulate pannus formation, which is fibrous tissue overgrowth obstructing the valve orifice, the degree of silicone coating on the sewing ring varied from 20%, 40%, 60% of orifice obstruction. In experiment system, acoustic signals from the valve were measured using microphone and amplifier. The microphone was attached to a coupler to remove environmental noise. Acoustic signals were sampled by an AID converter, frequency spectrum was obtained by the algorithm of spectral analysis. To quantitatively distinguish the frequency peak of the normal valve from that of the thrombosed valves, analysis using a neural network was employed. A return map was applied to evaluate continuous monitoring of valve motion cycle. The in-vivo data also obtained from animals with mechanical valves in circulatory devices as well as patients with mechanical valve replacement for 1 year or longer before. Each spectrum wave showed a primary and secondary peak. The secondary peak showed changes according to the thrombus model. In the mock as well as the animal study, both spectral analysis and 3-layer neural network could differentiate the normal valves from thrombosed valves. In the human study, one of 10 patients showed shift of frequency spectrum, however the presence of valve thrombus was yet to be determined. Conclusively, acoustic signal measurement can be of suggestive as a noninvasive diagnostic tool in early detection of mechanical valve thrombosis.