• Title/Summary/Keyword: Mobile-lP

Search Result 150, Processing Time 0.033 seconds

Development of a rapid HPLC method for the determination of penciclovir in human plasma using a monolithic column and its application to a bioequivalence study (모노리틱 칼럼을 이용한 혈장 중 펜시를로버의 HPLC 신속분석법 개발 및 이를 이용한 생물학적동등성시험)

  • Kim, Jin Hee;Park, Ah Yeon;Jung, Eun Ha;Lee, Cheol Woo;Lee, Tae Ho;Youm, Jeong-Rok
    • Analytical Science and Technology
    • /
    • v.20 no.4
    • /
    • pp.323-330
    • /
    • 2007
  • A simple and rapid HPLC method with fluorescence detection(FLD) for quantitation of penciclovir in human plasma using a monolithic column was developed and validated. Penciclovir and ganciclovir(internal standard, I.S.) were separated on a Chromolith column RP-18e ($4.6{\times}100mm$) with a mobile phase consisting of a mixture of (A) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (3/97, pH 2.5) and (B) methanol/50 mM sodium phosphate buffer containing 200 mg/L sodium dodecyl sulfate (50/50, pH 2.5) at a flow gradient of $1.6{\sim}4.0mL/min$. The retention times of penciclovir and internal standard were less than 4.0 min. Calibration curve was linear ($R^2=0.9994$) over a concentration range of $0.1{\sim}5{\mu}g/mL$. Intra-day precision, accuracy and inter-day precision were 1.36~8.55 %, 92.8~100.0 % and 0.93~5.62 %, respectively with a limit of quantitation at $0.1{\mu}g/mL$. The present HPLC-FLD method is sensitive, precise and accurate. The method described herein has been successfully used for the bioequivalence study of a famciclovir formulation product after oral administration to healthy Korean volunteers.

Capillary Electrochromatography with Liquid Crystal Crown Ether Modified Hybrid Silica Monolith for Analysis of Imidacloprid and Carbendazim in Tomatoes

  • Wang, Mingming;Feng, Rui;Shen, Jing;Chen, Hao;Zeng, Zhaorui
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.7
    • /
    • pp.2224-2228
    • /
    • 2012
  • This study describes the ability of capillary electrochromatography (CEC) for the determination of imidacloprid and carbendazim in tomato samples. A novel liquid crystal crown ether modified hybrid silica monolithic column was synthesized, characterized and developed as separation column for the first time. Baseline separation of imidacloprid and carbendazim could be achieved using a mobile phase containing 90% (v/v) 20 mmol/L phosphate buffer (pH 7.0) and 10% (v/v) acetonitrile. The matrix matched calibration curves were linear with correlation coefficient $r^2$ > 0.9998 in the range of 0.20-10.00 mg/L. The limits of detection for imidacloprid and carbendazim were 0.061 and 0.15 mg/kg, respectively, which were below the maximum residue limits established by the European Union as well as Codex Alimentarius. Average recoveries for imidacloprid and carbendazim varied from 101.6-108.0% with relative standard deviations lower than 6.3%. This method was applied to the analysis of tomatoes collected from local markets.

Retention Factors and Resolutions of Amino Benzoic Acid Isomers with Some Ionic Liquids

  • Zheng, Jinzhu;Polyakova, Yulia;Row, Kyung-Ho
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.11 no.6
    • /
    • pp.477-483
    • /
    • 2006
  • Ionic liquids in the form of organic salts are being widely used as new solvent media. In this paper three positional isomers, o-amino benzoic acid, m-amino benzoic acid, and p-amino benzoic acids were separated with four different ionic liquids as mobile phase additives using high performance liquid chromatography (HPLC). The following ionic liquids were used: 1-butyl-3-methylimidazolium tetrafluoroborate ([BMIm][$BF_{4}$]), 1-ethyl-3-methylimidazolium tetrafluoroborate ([EMIm][$BF_{4}$]), 1-ethyl-3-methylimidazolium methylsulfate ([EMIm][MS]), and 1-octyl-3-methylimidazolium methylsulfate ([OMIm][MS]). The effects of the alkyl group length on the imidazolium ring and its counterion, and the concentrations of the ionic liquids on the retention factors and resolutions of amino benzoic acid isomers were tested. The results of the separations with ionic liquids as the eluents were better than those without ionic liquids. Excellent separations of the three isomers were achieved using 2.0-8.0 mM/L [OMIm][MS] and 1.0-8.0 mM/L [EMIm][MS] as the eluent modifiers.

A Study on Implementation and Performance of the Low Noise Amplifier for Satellite Mobile Communication System (위성통신용 광대역 저잡음증폭기의 구현 및 성능평가에 관한 연구)

  • 전중성;김동일;배정칠
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.1
    • /
    • pp.67-76
    • /
    • 2000
  • In this paper, a low noise amplifier has been developed, which is operating at L-band i.e., 1525-1575 MHz. By using resistive decoupling circuits, the resistor dissipates undesired signal in low frequency band. By adopting this design method the stability of the LNA is increased and the input impedance matching is improved. The LNA consists of the low noise GaAs FET ATF-10136 and the internally matched VNA-25. The low LNA is fabricated by both the RP circuit and the self-bias circuits in an aluminum housing. As a result, the characteristics of the LNA implemented show more than 32 dB in gain, lower than 0.5 dB in noise figure, 18.6 dBm output gain in 1 dB gain compression point.

  • PDF

A Study on FPGA Implementation of Radix-16 Montgomery Modular Multiplication and Comparison of Power Dissipation (Radix-16 Montgomery Modular 곱셈 알고리즘의 FPGA 구현과 전력 소모 비교에 관한 연구)

  • Kim, Pan-Ki;Kim, Ki-Young;Kim, Seok-Yoon
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.813-816
    • /
    • 2005
  • In last several years, the need for the right of privacy and mobile banking has increased. The RSA system is one of the most widely used public key cryptography systems, and its core arithmetic operation IS modular multiplication. P. L. Montgomery proposed a very efficient modular multiplication technique that is well suited to hardware implementation. In this paper, the montgomery modular multiplication algorithms(CIOS, SOS, FIOS) , developed by Cetin Kaya Koc, is presented and implemented using radix-16 and Altera FPGA. Also, we undertake comparisons of power dissipation using Quatrus II PowerPlay Power Analyzer.

  • PDF

Determination of S- and R-Amlodipine in Rat Plasma using LC-MS/MS After Oral Administration of S-Amlodipine and Racemic Amlodipine

  • Yoo, Hye-Hyun;Kim, Tae-Kon;Lee, Bong-Yong;Kim, Dong-Hyun
    • Mass Spectrometry Letters
    • /
    • v.2 no.4
    • /
    • pp.88-91
    • /
    • 2011
  • The pharmacokinetic properties of S-amlodipine were studied using racemic amlodipine and single S-enantiomer (SK310) administration to rats. Plasma levels of the drug were determined using chiral liquid chromatography coupled with tandem mass spectrometry following solid phase extraction. The stereospecific analysis of amlodipine was performed on an ${\alpha}$-acid glycoprotein (AGP) column using a mobile phase comprising 10 mM ammonium acetate (pH 4.0) and propanol at a flow rate of 0.2 mL/min. This method was used to perform a comparative study of the pharmacokinetics of amlodipine and SK310. The results revealed that the pharmacokinetic profile of S-amlodipine after the administration of SK310 was comparable to that following the administration of the racemic mixture.

Method Development of Verapamil in Presence of NSAIDs using RP-HPLC Technique

  • Sultana, Najma;Arayne, M. Saeed;Waheed, Abdul
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.7
    • /
    • pp.2274-2278
    • /
    • 2011
  • Verapamil is a calcium channel blocker and is classified as a class IV anti-arrhythmic agent. It is used in the control of supra ventricular tachyarrhythmias, and in the management of classical and variant angina pectoris. It is also used in the treatment of hypertension and used as an important therapeutic agent for angina pectoris, ischemic heart disease, hypertension and hypertrophic cardiomyopathy. Verapamil commonly co-administered with NSAIDs (non-steroidal anti-inflammatory drugs) i.e. diclofenac sodium, flurbiprofen, Ibuprofen, mefanamic acid and meloxicam. A simple and rapid RP-HPLC method for simultaneous determination and quantification of verapamil and NSAIDs was developed and validated. The mobile phase constituted of acetonitrile: water (55:45) whose pH was adjusted at 2.7 and pumped at a flow rate of 2.0 mL $min^{-1}$ at 230 nm. The proposed method is simple, precise, accurate, low cost and least time consuming for the simultaneous determination of verapamil and NSAIDs which can be effectively applied for the analysis of human serum.

An Efficient Routing Algorithm for extreme networking environments (극단적인 네트워크 환경을 위한 효율적인 라우팅 알고리즘)

  • Wang, Jong Soo;Seo, Doo Ok
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.8 no.1
    • /
    • pp.47-53
    • /
    • 2012
  • Sensor networks and car networks that have different structure from that of conventional TCP/IP network require extreme network environment due to frequent change of connectivity. Because such extreme network environment has characteristics like unreliable link connectivity, long delay time, asymmetrical data transfer rate, and high error rate, etc., it is difficult to perform normally with the conventional TCP/P-based routing. DTNs (delay and disruption tolerant network) was designed to support data transfer in extreme network environment with long delay time and no guarantee for continuous connectivity between terminals. This study suggests an algorithm that limits the maximum number of copying transferred message to L by improving the spray and wait routing protocol, which is one of the conventional DTNs routing protocols, and using the azimuth and density data of the mobile nods. The suggested algorithm was examined by using ONE, a DTNs simulator. As a result, it could reduce the delay time and overhead of unnecessary packets compared to the conventional spray and wait routing protocol.

Survivability, Mobility, and Functionality of n Rover for Radars in Polar Regions

  • Stansbury, Richard S.;Akers, Eric L.;Harmon, Hans P.;Agah, Arvin
    • International Journal of Control, Automation, and Systems
    • /
    • v.2 no.3
    • /
    • pp.343-353
    • /
    • 2004
  • This paper presents the survivability, mobility, and functionality of a rover as part of a radar system for polar regions. Rovers can provide autonomy and precision for radars used to measure ice thickness and other characteristics of ice sheets in Greenland and Antarctica. These rovers can be used to move radar antennas in precise patterns for synthetic aperture radars while providing environmental protection and power to the onboard radar equipment. This paper describes the mobility, actuation, sensing, winterization, control, and virtual prototyping of a polar rover. The rover has been successfully tested in Greenland.

Determination of Prazosin in Human Plasma Using a Validated HPLC Method and Bioavaliability of a Tablet Formulation

  • Oh, Jung-Hyun;Cho, Young-Ah;Gwak, Hye-Sun;Noh, Eun-Sun;Lee, Na-Young;Chun, In-Koo
    • Proceedings of the PSK Conference
    • /
    • 2003.10b
    • /
    • pp.245.2-245.2
    • /
    • 2003
  • A rapid and reproducible high performance liquid chromatographic assay of prazosin in human plasma was developed. After addition of internal standard (IS, terazosin hydrochloride) and alkalization of the plasma, the drug and IS were extracted into t-butylmethylether. The organic phase was back-extracted with 0.05% phosphoric acid and 50 ${\mu}$l of the acid solution was injected into a reverse-phase C18 column with a mobile phase consisting of water: acetonitrile: triethylamine = 75 : 25 : 0.1 (pH 5.0). (omitted)

  • PDF