• Title/Summary/Keyword: Mobile-lP

Search Result 150, Processing Time 0.032 seconds

Characterization of degradation products of the Balsalazide by Mass spectrometry: Optimization of stability-indicating HPLC method for separation and quantification of process related impurities of Balsalazide

  • Chilakabattina Naga Narasimha Babu;Ch. Srinivasa Reddy;Bhagya Kumar Tatavarti;M. Radha Madhavi;Venkateswara Rao Anna
    • Analytical Science and Technology
    • /
    • v.37 no.1
    • /
    • pp.25-38
    • /
    • 2024
  • The study aimed to investigate a novel approach by utilizing liquid chromatography (LC) and liquid chromatography-mass spectrometry (LC-MS) to separate, identify and characterize very nominal quantities of degradation products (DPs) of balsalazide along with its process related impurities without isolation from their reaction mixtures. The impurities along with balsalazide were resolved on spherisorb ODS2 (250×4.6 mm, 5.0 ㎛) column at room temperature using 0.2 M sodium acetate solution at pH 4.5 and methanol in the ratio of 55:45 (v/v) as mobile phase pumped isocratically at 1.0 mL/min as mobile phase and UV detection at 255 nm. The method shows sensitive detection limit of 0.003 ㎍/mL, 0.015 ㎍/mL and 0.009 ㎍/mL respectively for impurity 1, 2 and 3 with calibration curve liner in the range of 50-300 ㎍/mL for balsalazide and 0.05-0.30 for its impurities. The balsalazide pure compound was subjected to stress studies and a total of four degradation products (DPs) were formed during the stress study and all the DPs were characterized with the help of their fragmentation pattern and the masses obtained upon LC-MS/MS. The DPs were identified as 3-({4-[(E)-(4-hydroxyphenyl) diazenyl]benzoyl}amino)propanoic acid (DP 1), 4-[(E)-(4-hydroxyphenyl)diazenyl] benzamide (DP 2), 5-[(E)-(4-carbamoylphenyl)diazenyl]-2-hydroxybenzoic acid (DP 3) and 3-({4-[(E)-phenyldiazenyl]benzoyl}amino)propanoic acid (DP 4). Based on findings, it was concluded that, the proposed method was successfully applicable for routine analysis of balsalazide and its process related impurities in pure drug and formulations and also applicable for identification of known and unknown impurities of balsalazide.

Determination of Fluorescent Whitening Agents in Paper Materials by Ion-Pair Reversed-Phase High-Performance Liquid Chromatography

  • Kim, Jeong Soo;Kim, Do Hwan;Kim, Keon
    • Bulletin of the Korean Chemical Society
    • /
    • v.33 no.12
    • /
    • pp.3971-3976
    • /
    • 2012
  • A simple method was developed for the analysis of seven stilbene-type fluorescent whitening agents (FWAs) in paper materials by ion-pair reversed-phase high-performance liquid chromatography with fluorescence detection. These stilbene-type FWAs included two disulfonate, two tetrasulfonate, and three hexasulfonate compounds. After optimization of chromatographic conditions, the FWAs were satisfactorily separated using a reversed-phase column (RP-18) with the following isocratic mobile phase: methanol-water (60:40) containing 17.5 mM TBABr and 10 mM citrate buffer (pH = 7.0). The calibration plot was linear in the range from 5 to 500 ng/mL for two disulfo-FWAs and from 1 to 500 ng/mL for the other five FWAs. Precision levels of the calibration curve as indicated by RSD of response factors were 1.2 and 8.1%. Limits of quantitation (LOQ) ranged from 1.2 to 11 ng/mL.

Cadmium, Cu, Ph and Zn Contamination of Stream Sediments and Waters in a Stream Around the Dalsung Cu-W Mine, Korea (달성 Cu-W 광산 주변 수계의 하상퇴적물과 자연수의 Cd, Cu, Pb 및 Zn 오염)

  • Jung, Myung Chae
    • Economic and Environmental Geology
    • /
    • v.29 no.3
    • /
    • pp.305-313
    • /
    • 1996
  • In order to investigate the extent and degree of Cd, Cu, Pb and Zn contamination affected by mining activities of the Dalsung Cu~W mine, sampling of stream sediments and waters has been undertaken up to 1.5 km downstream from the mine at 50~150 meter intervals. Analysis of the samples was carried out using ICP-AES for Cd, Cu, Pb and Zn. Physical and chemical properties of sediments (pH, organic matter contents, cation exchange capacity) and waters (pH, Eh and temperature) were also measured. The properties of the sediment samples were characterized by low pH (3.0~5.5), low organic matter contents (2~5%) and a moderate degree of cation exchange capacity (7~15 meq/100 g) with a high proportion of sand fraction. The pH values of water samples ranged from 3.0 to 5.0 and the Eh levels were in the range of 350~530 mV. Concentrations of Cd, Cu, Pb and Zn in the sediments averaged 3.2 mg/kg, 1,390 mg/kg, 451 mg/kg and 262 mg/kg with the range of 0.6~11.4 mg/kg, 15~3,800 mg/kg, 14~1,330 mg/kg and 63~1,060 mg/kg, respectively. Significant levels of the heavy metals were also found in the water samples with the range of $10{\sim}170{\mu}gCd/l$, $300{\sim}41,600{\mu}gCu/l$, $10{\sim}80{\mu}gPb/l$ and $700{\sim}15,400{\mu}gZn/l$. These elevated concentrations in the sediments and waters may be caused by the weathering of mine waste materials and their high solubilities under acidic and/or oxidizing conditions. Although metal concentrations in the samples decrease with the distance from the mine, heavy metal contamination of sediments and waters were also found at the 1.5 km downstream due to the mobile conditions of the heavy metals, with particular reference to Cd and Zn in stream waters.

  • PDF

Liquid Chromatography-Tandem Mass Spectrometry for the Determination of Lithospermic Acid B in Rat Serum

  • Kim, Hui-Hyun;Ji, Hye-Young;Lee, Hye-Won;Kim, Youn-Chul;Sohn, Dong-Hwan;Lee , Hye-Suk
    • Archives of Pharmacal Research
    • /
    • v.27 no.12
    • /
    • pp.1202-1206
    • /
    • 2004
  • A rapid, sensitive and selective liquid chromatography-tandem mass spectrometric (LC-MS/ MS) method for the determination of lithospermic acid B (LSB) in rat serum was developed. LSB and internal standard, 7-hydroxy-3-phenyl-chromen-4-one (HPC) were extracted from rat serum with methyl-tert-butyl ether at acidic pH and analyzed on a Luna $C_8$ column with the mobile phase of acetonitrile-ammonium formate (10 mM, pH 6.5) (50:50, v/v). The analytes were detected using a negative electrospray ionization tandem mass spectrometry in the multiple- reaction-monitoring mode. The standard curve was linear $(r^2 = 0.997)$ over the concentration range of 10.0-500 ng/mL. The coefficient of variation and relative error for intra- and interassay at three QC levels were 1.1~6.2% and -10.3~-2.7%, respectively. The recovery of LSB from serum sample ranged from 73.2 to 79.5%, with that of HPC (internal standard) being 75.1 %. The lower limit of quantification for LSB was 10 ng/mL using 50 ${\mu}L$ of serum sample.

Observed tropical cyclone wind flow characteristics

  • Schroeder, John L.;Edwards, Becca P.;Giammanco, Ian M.
    • Wind and Structures
    • /
    • v.12 no.4
    • /
    • pp.349-381
    • /
    • 2009
  • Since 1998, several institutions have deployed mobile instrumented towers to collect research-grade meteorological data from landfalling tropical cyclones. This study examines the wind flow characteristics from seven landfalling tropical cyclones using data collected from eight individual mobile tower deployments which occurred from 1998-2005. Gust factor, turbulence intensity, and integral scale statistics are inspected relative to changing surface roughness, mean wind speed and storm-relative position. Radar data, acquired from the National Weather Service (NWS) Weather Surveillance Radar - 1988 Doppler (WSR-88D) network, are examined to explore potential relationships with respect to radar reflectivity and precipitation structure (convective versus stratiform). The results indicate tropical cyclone wind flow characteristics are strongly influenced by the surrounding surface roughness (i.e., exposure) at each observation site, but some secondary storm dependencies are also documented.

Changes in Phytoavailability of Cadmium, Copper, Lead, and Zinc after Application with Eggshell in Contaminated Agricultural Soil

  • Kim, Rog-Young;Yang, Jae E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.47 no.1
    • /
    • pp.41-47
    • /
    • 2014
  • Agricultural soils surrounding mine areas in South Korea are often contaminated with multiple metals such as Cd, Pb and Zn. It poses potential risks to plants, soil organisms, groundwater, and eventually human health. The aim of this study was to examine the changes in phytoavailability of Cd, Cu, Pb and Zn after application with calcined eggshell (CES; 0, 1, 3, and 5% W/W) in an agricultural soil contaminated by mine tailings. The contents of Cd, Cu, Pb and Zn in soils were 8.79, 65.4, 1602, and $692mgkg^{-1}$ (aqua regia dissolution), respectively. The experiments were conducted with lettuce (Lactuca sativa L. var. longifolia) grown under greenhouse conditions during a 30-d period. $NH_4NO_3$ solution was used to examine the mobile fraction of these metals in soil. The application of CES dramatically increased soil pH and inorganic carbon content in soil due to CaO and $CaCO_3$ of CES. The increased soil pH decreased the mobile fraction of Cd, Pb, Zn: from 3.49 to < $0.01mgkg^{-1}$ for Cd, from 79.4 to $1.75mgkg^{-1}$ for Pb, and from 29.6 to $1.13mgkg^{-1}$ for Zn with increasing treatment of CES from 0 to 5%. In contrast, the mobile fraction of Cu was increased from 0.05 to $3.08mgkg^{-1}$, probably due to the formation of soluble $CuCO_3{^0}$ and Cu-organic complex. This changes in the mobile fraction resulted in a diminished uptake of Cd, Pb and Zn by lettuce and an increased uptake of Cu: from 4.19 to < $0.001mgkg^{-1}$ dry weight (DW) for Cd, from 0.78 to < $0.001mgkg^{-1}$ DW for Pb, and from 133 to $50.0mgkg^{-1}$ DW for Zn and conversely, from 3.79 up to $8.21kg^{-1}$ DW for Cu. The increased contents of Cu in lettuce shoots did not exceed the toxic level of $>25mgkg^{-1}$ DW. The mobile contents of these metals in soils showed a strong relationship with their contents in plant roots and shoots. These results showed that CES effectively reduced the phytoavailability of Cd, Pb, and Zn to lettuce but elevated that of Cu in consequence of the changed binding forms of Cd, Cu, Pb, and Zn in soils. Based on these conclusions, CES can be used as an effective immobilization agent for Cd, Pb and Zn in contaminated soils. However, the CES should be applied in restricted doses due to too high increased pH in soils.

Determiniation and Validation of Alibendol using High Pressure Liquid Chromatography in Human plasma (고속액체크로마토그라피법을 이용한 사람 혈장 중 알리벤돌(Alibendol)의 정량 및 검증)

  • Song, Hyun-Ho;Yu, Ji-Young;Kim, Bo-Gyeom;Park, Hyeon-Ju;Choi, Kwang-Sik;Kwon, Young-Ee
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.295-299
    • /
    • 2010
  • The aim of this study was to develop and validate for determination of alibendol in human plasma by HPLC method. After precipitation of 500 ${\mu}l$ plasma samples by 50% methanol 50 ${\mu}l$ and 60% perchloric acid 30 ${\mu}l$ and the supernatant 50 ${\mu}l$ was injected into HPLC. The assay was performed isocratically using 10 mM potassium phosphate (pH 3.0) and acetonitrile (80 : 20, v/v) as mobile phase. The $C_{18}$ column (particle size $3.5{\mu}m$, $4.6{\times}50$ mm, Zorbax Eclipse) was used as a solid phase. The mobile phase was delivered at a flow-rate of 1.7 ml/min, detection was by ultraviolet absorption at 232 nm and concentrations were calculated on the basis of peak areas. In these conditions, alibendol can be separated from ethylparaben, the internal standard, and endogenous substances. The retention times of alibendol and ethylparaben were just about 2.6 and 3.5 minutes, respectively. This rapid HPLC method was validated by examining the precision and accuracy for inter- and intra-day analysis. The standard curve was linear ($R^2$=1.0000) over the concentration range of 0.05~20 ${\mu}g$/ml. The inter-day relative standard deviation (R.S.D.) and accuracy were 0.2~12.2% and 94.4~101.2% (82.7% at the lower limit of quatitation). The intra-day R.S.D. and accuracy were 0.1~11.8% and 98.8~102.5%, respectively. The method was successfully applied to the determination of alibendol in plasma for a pharmacokinetic study.

Development and Validation of an Analytical Method for Glucuronolactone in Energy Drinks by Hydrophilic Interaction Liquid Chromatography-electrospray Tandem Mass Spectrometry

  • Oh, Mi Hyune;Lim, Moo Song;Chai, Jeung Young;Kim, Eun Jung;Cho, Joong Hoon;Lim, Chul Joo;Choi, Sun Ok
    • Journal of Food Hygiene and Safety
    • /
    • v.32 no.2
    • /
    • pp.89-95
    • /
    • 2017
  • A rapid, sensitive analytical method for glucuronolactone in beverages was developed and validated using hydrophilic interaction liquid chromatography coupled to electrospray ionization tandem mass spectrometry (HILIC-ESI-MS/MS). To determine the optimum analytical conditions for glucuronolactone, three different kinds of HILIC columns and two mobile phases with different pH values were examined. An amide-bonded stationary phase with a pH 9 acetonitrile-rich mobile phase was the best condition in terms of column retention, ESI-MS/MS response area, and signal-to-noise ratio. After extraction, glucuronolactone was separated through the HILIC amide column and detected by negative ESI-MS/MS in selected reaction monitoring (SRM) mode. Nine energy drinks sold in Korea were spiked with glucuronolactone at a concentration of 5 ng/mL; the Monster $Energy^{TM}$ sample showed the smallest peak area and its signal-to-noise ratio was used for method validation. Good linearity was obtained in the concentration range from 20 to 1500 ng/mL with a correlation coefficient > 0.998. The developed method had a limit of detection (LOD) of 6 ng/mL and a limit of quantitation (LOQ) of 20 ng/mL. The recovery of this method at concentration of 20, 100, 500, and 1000 ng/mL was 96.3%-99.2% with relative standard deviations (RSD) of 1.6%-14.0%. A reproducibility precision assessment at concentration of 100 and 500 ng/mL was carried out among three laboratories. The recovery of that evaluation was 95.1%-102.3% with RSD of 2.7%-7.0%. An analysis of variance indicated that there was no difference between the recovery results of the three laboratories at the 5% significance level. The validated method is applicable to inspecting beverages adulterated with glucuronolactone in Korea.

Determination of itraconazole in human plasma by high performance liquid chromatography (HPLC/UV를 이용한 혈장 중 이트라코나졸의 분석)

  • Jang, Hae Jong;Lee, Ye Rie;Lee, Kyung Ryul;Han, Sang-Beom;Kang, Seung Woo;Lee, Hee Joo
    • Analytical Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.239-243
    • /
    • 2006
  • This method is used for the determination of itraconazole in human plasma by liquid-liquid extraction and high performance liquid chromatography. Felodipine was used as an internal standard. After extraction of the plasma with diethyl ether, the centrifuged upper layer was then transferred. The supernantant was evaporated and then reconsituted with mobile phase. The mobile phase was composed of 10 mM ammonium acetate adjusted to pH 7 by phosphoric acid with a flow rate of 0.2 mL/min. A C18 reversed-phase column with a pre-column was used as the analytial column. Linear detection responses were obtained for itraconzole concentration range for 2~1,000 ng/mL. The correlation coefficient of linear regression($R^2$) was 0.9991, limit of quantification (LOQ) was 2 ng/mL, reproducibility was less than 10.8 %, and accuracy was 97.2~108.2%. This method has been successfully applied to the pharmacokinetic study of itraconazole in human plasma.

A Simple and Sensitive Assay for Cefepime in Human Plasma Using High Performance Liquid Chromatography

  • Kim, Young-Sun;Yim, Dong-Seok;Lee, Dong-Gun;Lee, Sang-Bok
    • The Korean Journal of Physiology and Pharmacology
    • /
    • v.7 no.4
    • /
    • pp.247-250
    • /
    • 2003
  • A simple and sensitive assay method was developed for cefepime in human plasma using high performance liquid chromatography (HPLC). Cefepime and cefadroxil (the internal standard) were extracted from heparinized human plasma by simple deproteination with perchloric acid. The extract was injected into an Atlantis dC18 column ($250{\times}4.6$ mm; particle size $5{\mu}m$, Waters) and the column was eluted with methanol and 0.01 M dihydrogen phosphate at pH 3.0 (15:85 v:v) as a mobile phase at a flow rate of 0.7 mL/min. Linearity was confirmed for the range 0.25 to $200{\mu}L/mL$ and the limit of quantitation was $0.25{\mu}L/mL$. The retention times were 10.2 min and 13.4 min for cefepime and cefadroxil, respectively. This method was successfully applied to a pharmacokinetic study of cefepime in plasma from bone marrow transplant patients.