• 제목/요약/키워드: Mobile Health Units

검색결과 8건 처리시간 0.022초

휴대용 무선 응급 단말기 및 통합 시스템 개발 (Development of Portable Wireless Emergency Units and Integrated System)

  • 송미혜;명현석;이경중
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 D
    • /
    • pp.2161-2162
    • /
    • 2006
  • In this study, we developed five mobile units and an integrated system which can manage vital signs from each unit using Bluetooth wireless communication. The five kinds of mobile unit were so designed that each has different function to be applied according to the condition of patient properly. The mobile units can measure ECG signal of single or 12 channel, blood pressure, pulse and SpO2 signal from a patient. Also, to reduce the uncomfortable measurement, several types of units such as belt type, wrist type and necklace type were designed. Our proposed system can integrate and monitor several biological signals from different patient by using Bluetooth wireless communication simultaneously. The developed system was evaluated in the simulated emergent situation and showed the system can monitor 5 patients in maximum according to the data quality. It showed the possibilities that the developed system can be used effectively for emergency situation or in- or out-hospital transport of patient. In future, with the combination of mobile communication technique, a patient who is in emergency situation can be provided with proper first-aid and a doctor can pile information of patient and give better diagnosis and treatments.

  • PDF

일 지역 이동형 방문보건 전산시스템의 재구축과 활용의 효과 (The Effects of a Mobile Computerized System for Individual Tailored Home Care Services in a City)

  • 박남희;장랑;김정영;김명수
    • 지역사회간호학회지
    • /
    • 제23권1호
    • /
    • pp.71-81
    • /
    • 2012
  • Purpose: The aim of this study was to evaluate the process and outcome of a mobile computerized system for individual home visiting healthcare. Methods: A nonequivalent control group non-synchronized design was employed for this study. The newly constructed system was administered to 80 healthcare providers in the experimental group for 8 weeks. Data were analyzed using descriptive analysis, t-test, and ANCOVA with the SPSS 18.0 program. Results: In the process stage, the difference in the frequency of computerized information usage between the experimental and control groups was significant as $8.88{\pm}3.20$ and $7.08{\pm}2.92$, respectively (t=3.90, p<.001). In the outcome evaluation stage, all kinds of healthy lifestyle such as alcohol use, nutrition, weight management and mental health were not improved. Conclusion: The findings of this study showed that the revised mobile computerized system was an effective device for individual visiting healthcare providers. Further advanced strategies for using this system should be developed and applied in a broad range of community healthcare.

심혈관질환 위험인자를 가진 중소규모 사업장 남성 근로자의 모바일헬스 앱 활용 건강파트너십 프로그램의 효과: 무작위 실험연구 (Effects of a Health Partnership Program Using Mobile Health Application for Male Workers with Cardiovascular Risk Factors in Small and Medium Enterprises: A Randomized Controlled Trial)

  • 김은진;황선영
    • 대한간호학회지
    • /
    • 제54권1호
    • /
    • pp.44-58
    • /
    • 2024
  • Purpose: This study aimed to apply a health partnership program using commercially available mobile health apps to improve cardiovascular risk factors in male employees and verify its effectiveness. Methods: Using a randomized control group pretest-posttest design, male employees with cardiovascular risk factors from five small and medium-sized workplaces were randomly assigned to an experimental group (n = 32) and a control group (n = 31). The experimental group was encouraged to use three mobile health apps for 12 weeks to acquire the necessary cardiovascular disease-related information and practice strengthening training, walking, and diet management appropriate to their level. They also received feedback on their weekly activities and motivational text messages from health partners. Hypotheses were tested using the SPSS WIN 22.0. Results: The experimental group showed a significant difference compared to the control group in terms of their perception of mobile health app (p < .05), self-efficacy for exercise and diet, self-management partnership, and cardiovascular disease prevention health behavior (p < .001). In particular, there were significant decreases in the body mass index, ratio, serum fasting blood sugar, total cholesterol, and triglyceride in the experimental group (p < .001); however, there was no significant difference in high-density lipoprotein-cholesterol. Conclusion: Intervention using mobile apps based on partnership with health managers is effective in improving the objective cardiovascular risk index in male employees; therefore, such intervention should be continuously used as a useful lifestyle modification strategy in the workplace.

이동형 전산화단층촬영장치의 기본 안전 및 필수 성능 기준을 마련하기 위한 연구 (A Study on Establishment of Basic Safety and Essential Performance Criteria of Mobile Computed Tomography)

  • 김은혜;박혜민;김정민
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제44권3호
    • /
    • pp.261-267
    • /
    • 2021
  • As the number of Coronavirus Disease-19 (COVID-19) patients increases in a global pandemic situation, the usefulness of mobile computed tomography (CT) is gaining attention. Currently, mobile CT follows the basic safety and essential performance evaluation criteria of whole-body or limited-view X-ray CT in order to obtain device approval and evaluation in the Republic of Korea. Unlike stationary CT, mobile CT is not operated in shielded areas but rather areas such as intensive care units, operating rooms, or isolation rooms. Therefore, it requires a different basic safety and essential performance evaluation standard than stationary CT. In this study, four derived basic safety evaluation criteria related to electrical, mechanical, and radiation safety were included (dose indication test, protection against stray radiation, safety measures against excessive X-rays, half-value layer measurement); and seven essential performance evaluation criteria were included (tube voltage accuracy, mAs accuracy, radiation dose reproducibility, CT number of water, noise, uniformity, and spatial resolution); total eleven basic safety and essential performance evaluation criteria were selected. This study aims to establish appropriate basic safety and essential performance evaluation criteria for simultaneously obtaining images with diagnostic value and reducing the exposure of nearby patients, medical staff, and radiologic technologists during the use of mobile CT.

종합병원 진단용방사선장비의 고장유형 분석 (Studies on Failure Kind Analysis of the Radiologic Medical Equipment in General Hospital)

  • 이우철;김정래
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제22권2호
    • /
    • pp.33-39
    • /
    • 1999
  • This paper included a data analysis of the unit of medical devices using mainternance recording card that had medical devices of unit failure mode, hospital of failure mode and MTBF. The results of the analysis were as follows : 1. Medical devices of unit failure mode was the highest in QC/PM such A hospital as 33.9%, B hospital 30.9%, C hospital 30.3%, second degree was the Electrical and Electronic failure such A hospital as 23.5%, B hospital 25.3%, C hospital 28%, third degree was mechanical failure such A hospital as 19.5%, B hospital 22.5%, C hospital 25.4%. 2. Hospital of failure mode was the highest in Mobile X-ray device(A hospital 62.5%, B hospital 69.5%, C hospital 37.4%), and was the lowest in Sono devices(A hospital 16.76%, B hospital 8.4%, C hospital 7%). 3. Mean time between failures(MTBT) was the highest in SONO devices and was the lowest in Mobile X-ray devices which have 200 - 400 failure hours. 4. Anverage failure ratio was the highest in Mobile X-ray devices(A hospital 31.3%, B hospital 34.8%, C hospital 18.7%), and was the lowest in Sono(Ultrasound) devices (A hospital 8.4%, B hospital 4.2%, C hospital 3.5%). 5. Failure ratio results of medical devices according to QC/PM part of unit failure mode were as follows ; A hospital was the highest part of QC/PM (50%) in Mamo X-ray device and was the lowest part of QC/PM(26.4%) in Castro X-ray. B hospital was the highest part of QC/PM(56%) in Mobile X-ray device, and the lowest part of QC/PM(12%) in Gastro X-ray. C hospital was the highest part of QC/PM(60%) in R/F X-ray device, and the lowest a part of QC/PM(21%) in Universal X-ray. It was found that the units responsible for most failure decreased by systematic management. We made the preventive maintenance schedule focusing on adjustement of operating and dust removal.

  • PDF

DOGF 기반의 모바일 프락시를 이용한 u-헬스케어 상황정보 시스템 (u-Healthcare Context Information System Using Mobile Proxy Based on Distributed Object Group Framework)

  • 정창원;안동인;강민규;주수종
    • 정보처리학회논문지D
    • /
    • 제15D권3호
    • /
    • pp.411-420
    • /
    • 2008
  • 본 논문에서는 헬스케어 홈 서비스를 위해 가정 내에 설치된 센서/기기로부터 수집된 위치, 건강 그리고 쾌적환경 정보를 이용하여 유비쿼터스 헬스케어를 지원하는 u-헬스케어 상황정보 시스템(HCIS)을 구현했다. HCIS는 분산자원의 맞춤형 관리모델인 분산객체그룹프레임워크(DOGF)를 기반으로 헬스케어 홈 환경에서 다양한 상황정보, 응용 그리고 장치들을 논리적인 하나 또는 그 이상의 단위로 그룹화하고 관리한다. 또한 본 시스템은 DOGF의 구성요소인 모바일프락시와 컨텍스트제공자를 통해 가정 내 거주자의 위치를 기반으로 연속적인 헬스케어용 멀티미디어 서비스를 지원하고, 거주자에게 필요한 상황정보를 제공한다. 본 시스템의 수행성을 검증하기 위해 홈 내에서 제공되는 헬스케어 응용으로 거주자 위치기반의 끊임없는 멀티미디어 서비스와 처방 주의 및 스케줄 알림/알람 서비스를 구현했다. 그리고 시나리오에 따라 거주자가 위치한 영역의 서비스 장치를 통해 헬스케어 홈 서비스의 수행결과를 보였다.

스마트 IT 융합 플랫폼을 위한 지능형 센서 기술 동향 (Intelligent Sensor Technology Trend for Smart IT Convergence Platform)

  • 김혜진;진한빛;염우섭;김이경;박강호
    • 전자통신동향분석
    • /
    • 제34권5호
    • /
    • pp.14-25
    • /
    • 2019
  • As the Internet of Things, artificial intelligence and big data have received a lot of attention as key growth engines in the era of the fourth industrial revolution, data acquisition and utilization in mobile, automotive, robotics, manufacturing, agriculture, health care and national defense are becoming more important. Due to numerous data-based industrial changes, demand for sensor technologies is exploding, especially for intelligent sensor technologies that combine control, judgement, storage and communication functions with the sensors's own functions. Intelligent sensor technology can be defined as a convergence component technology that combines intelligent sensor units, intelligent algorithms, modules with signal processing circuits, and integrated plaform technologies. Intelligent sensor technology, which can be applied to variety of smart IT convergence services such as smart devices, smart homes, smart cars, smart factory, smart cities, and others, is evolving towards intelligent and convergence technologies that produce new high-value information through recognition, reasoning, and judgement based on artificial intelligence. As a result, development of intelligent sensor units is accelerating with strategies for miniaturization, low-power consumption and convergence, new form factor such as flexible and stretchable form, and integration of high-resolution sensor arrays. In the future, these intelligent sensor technologies will lead explosive sensor industries in the era of data-based artificial intelligence and will greatly contribute to enhancing nation's competitiveness in the global sensor market. In this report, we analyze and summarize the recent trends in intelligent sensor technologies, especially those for four core technologies.

The Direction of Neurosurgery to Overcome the Living with COVID-19 Era : The Possibility of Telemedicine in Neurosurgery

  • Min Ho Lee;Seu-Ryang Jang;Tae-Kyu Lee
    • Journal of Korean Neurosurgical Society
    • /
    • 제66권5호
    • /
    • pp.573-581
    • /
    • 2023
  • Objective : Due to the implementation of vaccinations and the development of therapeutic agents, the coronavirus disease 2019 (COVID-19) pandemic that started at the end of 2019 has entered a new phase. As a result, neurosurgeons should reconsider the way they treat their patients. As the COVID-19 situation prolongs, the change in neurosurgical emergency patients according to the number of confirmed cases is no longer clear. Outpatient treatment by telephone was permitted according to government policy. In addition, visits to caregivers in the intensive care unit were limited. Methods : The electronic medical records of patients who had been treated over the phone for a month (during April 2020, while the hospital was closing) were reviewed. Meanwhile, according to the limited visits to the intensive care unit, a video meeting was held with the caregivers. After the video meeting, satisfaction was evaluated using a questionnaire. Results : During April 2020, 1021 patients received non-face-to-face care over the telephone. Among the patients, no critical medical problem occurred due to non-face-to-face care. From July 2021 to December 2021, 321 patients were admitted to the neurosurgical intensive care unit and 107 patients (33.3%) including their caregivers agreed to video visits. Twice a week, advance notice was given that access would be made through a mobile device and the nurse explained to caregivers how to use the mobile device. The time for the video meeting was approximately 20 minutes per patient. Based on the questionnaire, 81 respondents (75.7%) answered that they agreed, and 26 respondents (24.3%) answered that they strongly agreed that was easy to communicate through video meetings. Fifty-two (48.6%) agreed and 55 (51.4%) strongly agreed that they were easy to understand the doctor's explanation. For overall satisfaction with this video meeting, three respondents (2.8%) gave 4/5 points and 95 respondents (88.8%) gave 5/5 points, and nine (8.4%) gave 3/5 points. Their reason was that there was not enough time. Conclusion : In situations where patient visits are limited, video meetings through a mobile device can provide sufficient satisfaction to caregivers. Telemedicine will likely become common in the near future. Health care professionals should prepare and respond to these needs and changes. Therefore, establishing a system with institutional support is necessary.