Fabrication of Sm0.5Sr0.5CoO3 cathode films for intermediate temperature SOFCs by electrostatic spray deposition (정전분무증착법에 의한 중온형 고체산화물 연료전지를 위한 Sm0.5Sr0.5CoO3 양극막의 제조)

  • Park, In-Yu;Im, Jong-Mo;Jung, Yeong-Geul;Shin, Dong-Wook
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.20 no.2
    • /
    • pp.69-73
    • /
    • 2010
  • The microstructural change of the $Sm_{0.5}Sr_{0.5}CoO_3$ (SSC) electrode for a cathode material of solid oxdie fuel cells (SOFCs) deposited by the electrostatic spray deposition (ESD) technique was characterized. Samarium chloride hexahydrate $(SmCl_3{\cdot}6H_2O)$, strontium chloride hexahydrate $(SrCl_2{\cdot}gH_2O)$, cobalt nitrate hexahydrate $(Co(No_3)_2{\cdot}6H_2O)$ as starting materials and methyl alcohol as solvent were used to make precursor solution. The suitable porous SSC films for a cathode of SOFCs were deposited on Si substrate and it is observed that the microstructure was strongly dependent on processing parameters such as deposition time, substrate temperature, and applied voltage. Scanning Electron Microscope (SEM) and X-ray Diffractometer (XRD) measurement were used to investigate the microstructure and crystallinity of the SSC films. The ESD technique is shown to be an efficient method in which the SOFCs' cathode film can be fabricated with the desired phases and microstructure.

Growth Characteristics of Spinaches by Nursery Media and the Seeding Number Per Plug Tray Cell in Hydroponics (시금치의 육묘배지와 파종 종자량에 따른 수경재배 생육 특성)

  • Seo, Jong-Bun;Jung, Jong-Mo;Kim, Sun-Kook;Choi, Kyong-Ju;Kim, Joung-Geun;Hong, Sae-Jin
    • Journal of Bio-Environment Control
    • /
    • v.16 no.1
    • /
    • pp.62-66
    • /
    • 2007
  • This study was carried out to develop the stable plug seedling production for hydroponics of spinaches by various nursery media, plug tray size and seed number per plug tray cell. When plant grown in various nursery media, the seeding stand rate was shown in order of granular rockwool with good water retention, granular rockwool>granular rockwool mixed with pearlite>cocopeat>pearlite>poly urethane foame. Thus, poly urethane foame indicated the lower seedling stand rate. There was no difference in growth of the seedlings md the seeding stand rate by the plug tray size, and no significant difference in the plant height and the number of leaves among the seed number per plug tray cell. But, leaf area of plant in 2 grains seeding per cell was $113.0cm^2$, was wider in compared with 5 grains seeding of which leaf area was $88.0cm^2$. Accordingly, the leaf area per plant decreased as more and more the number of seeds per plug tray cell increased. The fresh weight of a plant per plug tray cell was the heaviest with 12.5g in the 2 grains, and the total fresh weight of plants per cell was 33.9g in 4 grains seeding, thus it tended to was bigger compared with other treatments. Consequently, given that the number of seeds per cell was decreased, the fresh weight of a plant increased. On the other hand, the total fresh weight per cell showed a tendency to be reducing as more and more the number of seeds per plug tray cell decreased. The yield in the 4 grains seeding was increased by 46% as $14,910kg{\cdot}ha^{-1}$ in compared with the yield in 2 grains seeding as $10,200kg{\cdot}ha^{-1}$.

Efficacy of In-Ovo Vaccination against Marek's Disease in Commercial Broiler (마렉백신의 In-Ovo 접종에 따른 육계에서의 효능 평가)

  • Um, H.J.;Won, M.Y.;Lee, D.W.;Go, D.W.;Mo, I.P.
    • Korean Journal of Poultry Science
    • /
    • v.33 no.4
    • /
    • pp.295-301
    • /
    • 2006
  • This study has been designed to evaluate the efficacy of MD in-ovo vaccination in broiler and to find the contamination level of MD virus in broiler farms. A nested PCR test was used to find the level of filed contamination of pathogenic MD virus in the commercial broiler farms. The positive rate of farms contaminated with pathogenic MD virus was 26.09%. And to evaluate the efficacy of MD vaccination, performance factors such as the mortality, feed conversion rate and body weight at market age has been recorded and compared among farms. There was no difference on these factors between vaccinated and non-vaccinated farms except performance. We need further investigation of the film with low performance index. The B/B ratio, which is common index for the evaluation of bursal changes, was calculated and compared between vaccinated and non-vaccinated group There were significant decreases of B/B ratio in the both group without any statistical difference between groups. The reason of decreased bursal size may be due to other infection such as IBD. From this study, we can know that the contamination rate of fm with pathogenic MD virus was very low and not different from previous study. However, the difference of the contamination rate in different locations recommends periodical monitoring on these areas.

A Study on the Appropriate Reconstruction of the CBCT Images of Mandibular Canals (CBCT 영상에서 구치부의 하악관 형태에 따른 재구성 방법 연구)

  • Jeong, Cheon-Soo;Mo, Eun-Hee;Lee, Gee-Heun;Han, Beom-Hee;Kim, Seung-Chul;Kim, Jung-Sam;Lim, Cheong-Hwan
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.6
    • /
    • pp.369-375
    • /
    • 2011
  • In dental radiography, panoramic views cause distortion and thus may bring about inaccurate results in the process of quantitative analysis. In this connection, there has recently been an increasing use of cone beam computed tomography (CBCT) that is known to provide high-resolution images and positional information. In this study, a dental computed tomography unit, 'DCT-90-P IMPLAGRAPHY (Vatech, Korea)', was applied to 20 patients for 24 seconds respectively, with a tube voltage of 85kVp and a tube current of 7mA. The data of CBCT were three-dimensionally reconstructed by use of a computer program, and were histomorphometrically analyzed. The results showed that the diameter of mandibular canal is less distorted at a certain inclination of the mandibular body. The image tends to seem more distended in proportion to the distance between the subject and film. Also, the image tends to be affected according as it is out of focus. In conclusion, it requires that the image should be reconstructed in light of anatomic position and structure.

Growth Characteristics of Ginseng Seedlings as Affected by Mixed Nursery Soil under Polyethylene Film Covered Greenhouse (비닐하우스에서 상토의 조성에 따른 묘삼의 생장특성)

  • Park, Hong Woo;Jang, In Bae;Kim, Young Chang;Mo, Hwang Sung;Park, Kee Choon;Yu, Jin;Kim, Jang Uk;Lee, Eung Ho;Kim, Ki Hong;Hyun, Dong Yun
    • Korean Journal of Medicinal Crop Science
    • /
    • v.22 no.5
    • /
    • pp.363-368
    • /
    • 2014
  • This study was conducted to find out the optimum composition of nursery soil for raising seedling of ginseng (Panax ginseng C. A. Meyer). Total 9 kinds of raw materials were used such as peat-moss, perlite, leaf mould, rice bran, gull's guano, castor-oil plant bark, palm bark, cow manure and chicken manure for optimum composition of nursery soil in ginseng. Occurrence of damping-off in ginseng was lowered about 50% in nursery soil type 1, 2 and 4 than in other types nursery soil in June, and occurrence rate of rusty root also lowest in nursery soil type 1. As the salinity of nursery soil increased, so did the occurrence of physiological disorder in ginseng seedling. The cause of salinity increasing in nursery soil has closely relation to $NO_3-N$, $P_2O_5$ and $Na^+$ content. Plant height, root length, diameter and weight were longer and heavier in nursery soil type 1 (mixing ratio of peat-moss, perlite and leaf mould was 50 : 20 : 30 based in volume) than in other types of nursery soil. So nursery soil type 1 was selected for raising seedling of ginseng. pH and electric conductivity (EC) of selected nursery soil type 1 was 5.55 and 0.13 dS/m. Contents of $NO_3-N$ and $P_2O_5$ were 21.0 and 40.0 mg/L, and $K^+$ 0.36, $Ca^{2+}$ 3.38, $Mg^{2+}$ 2.01 and $Na^+$ $0.09cmol^+/L$, respectively.

Development of Portable X-ray CT System I - Evaluation of Wood Density using X-ray Radiography - (현장 적용이 가능한 X선 CT 시스템 개발 I - X선 촬영법을 이용한 목재의 밀도 측정 -)

  • Kim, Kwang-Mo;Lee, Sang-Joon;Lee, Jun-Jae
    • Journal of the Korean Wood Science and Technology
    • /
    • v.34 no.1
    • /
    • pp.15-22
    • /
    • 2006
  • ln order to manage efficiently many ancient wooden buildings, which have been preserved as cultural properties in Korea, the internal state of wood members should be evaluated exactly and periodically by a NDE (non-destructive evaluation) method. A research project was planned to develop an X-ray CT (computed tomography) system as a NDE method for wood, which could be easily applied in field. This paper includes the first part of this project. First of all, to establish a measuring procedure of wood density using X-ray radiography, the correlation between X-ray intensity and the film brightness was evaluated. Also, initial X-ray intensity was quantified with various radiate conditions controlled by the tube voltage and tube current. And then, the effects of density, annual ring angle, and thickness on the mass attenuation coefficient of wood were examined. Finally, Beer's law was modified with the above results and adopted to calculate the density of wood. As a result of this study, the measuring procedure of wood density was established using a portable soft X-ray device and this procedure was verified with some small wood specimens. This results will he used valuably for the following researches to develop a portable X-ray CT system.

Water Repellent Finishes of Polyester Fiber Using Glow Discharge (글로우방전을 이용한 폴리에스테르섬유의 발수가공)

  • Mo, Sang Young;Kim, Gi Lyong;Kim, Tae Nyun;Chun, Tae Il
    • Textile Coloration and Finishing
    • /
    • v.5 no.4
    • /
    • pp.29-41
    • /
    • 1993
  • In order to surface Hydrophobilization of Poly(ethylene terephthalate) (PET) fiber samples were treated in the atmosphere of CF$_{4}$ or $C_{2}$F$_{6}$glow discharge. The sample used in this study was PET film which is 75$\mu$m thick made by Teijin, O-Type(Japan). The cleaned samples were placed in plasma reactor made of pyrex glass cylinder, and plasma processing was carried out by glow discharge of CF$_{4}$ or $C_{2}$F$_{6}$ gas, being continuously fed by gas flow and continuously pumped out by a vacuum system. Electric power source for generate plasma state was sustained alternating current(60Hz) and voltage was sustained 600 volt. The duration of plasma treatment varied from 15 to 120 seconds except special case, the monomer gase pressure varied from 0.02 to 0.3 Torr and power range was 10 to 90 watts. The hydrophobic features of changed PET surface were evaluated by contact angle measurement and surface chemical characteristics were analyzed by ESCA. Results can be summerized as follows. 1. The most favorable setting position of substrate was the center area between the two electrodes. 2. $C_{2}$F$_{6}$ discharge current was lower than that of CF$_{4}$ when same voltage was sustained. Treated efficiency between CF$_{4}$ and $C_{2}$F$_{6}$ did not revealed significant differences under same electric power(wattage). 3. When monomer pressure is very low below 0.02 torr, as though substrate is exposed to CF$_{4}$ or $C_{2}$F$_{6}$ plasma, it tend to be hydrophilic through a little of fluorine bond and a great deal of oxidizing reaction. 4. There brought good hydrophobilization when monomer pressure was more 0.1 torr and duration of glow discharge treatment was over 45 seconds. When monomer pressure was too high, discharge current became low. Although prolong the duration, there was no more high hydrophobilization. 5. According to ESCA analysis, there were a little CF bond and a prevailing CF$_{2}$ bond in CF$_{4}$-treated substrate. There were CF$_{3}$, a little CF and a prevailing CF$_{2}$ bond in $C_{2}$F$_{6}$-treated substrate.d substrate.

  • PDF

Export Competitiveness of Busan Port: Market Comparative Advantage Index (시장비교우위지수를 이용한 부산항의 수출경쟁력 분석)

  • Mo, Soo-Won;Chung, Hong-Young;Lee, Kwang-Bae
    • Journal of Korea Port Economic Association
    • /
    • v.31 no.3
    • /
    • pp.141-153
    • /
    • 2015
  • This paper is an attempt to analyze the comparative advantage of Busan Port to China. For this, we use the market comparative advantage index, which is a version of the revealed comparative advantage index. The market comparative advantage index (MCA) uses trade patterns to identify the sectors in which a region has a comparative advantage, in this case by comparing Busan Port's trade profile with the world average (China). The indices are calculated at the commodity level of the HS four-digit classification. The export data used in this study are obtained from the Korea International Trade Association. Exports to China accounted for almost one third of Korean exports in 2014. There are, however, structural differences among the main export items of Busan Port. This paper, therefore, employs MCA indices to reveal the behaviors of the ten main export items, which are "HS3920-other plates/sheets/film/foil of plastics," "HS7606-aluminum plates/sheets/strip," "HS8479-unspecified machines/medical appliances," "HS8486-machines for semiconductor devices or wafers," "HS8529-parts for transmission apparatus for television," "HS8703-motor vehicles for the transport of persons," "HS8708-parts of motor vehicles," "HS9001-optical fibers," and "HS9013-liquid crystal devices." The study shows that export competitiveness of nine items increases, the exception being HS8703. However, China's import ratios of seven of the nine items for which the MCA indices go up are on the decrease, which means that it would be hard to expand the export market for these seven items, despite the higher MCA indices. Since the shares of the port's total exports to China of HS3907, HS8486, HS8529, HS9001, and HS9013 in total exports to China increase together with China's import ratio decreasing, these items may have promising export markets. MCA increases of HS7606 and HS8479 are attributable to China's lower import ratio, rather than a higher export share, so higher MCA indices do not guarantee higher export competitiveness for these items.

Fabrication of Lightweight Microwave Absorbers with Co-coated Hollow Silica Microspheres (저밀도 실리카 중공미세구 표면에 Co 박막의 코팅에 의한 경량 전파흡수체 제조)

  • Kim, Sun-Tae;Kim, Sung-Soo;Ahn, Jun-Mo;Kim, Keun-Hong
    • Journal of the Korean Magnetics Society
    • /
    • v.15 no.2
    • /
    • pp.67-75
    • /
    • 2005
  • For th aim of lightweight microwave absorbers, conductive and magnetic microspheres are fabricated by plating of Co films on hollow ceramic microspheres of low density. Metal plating was carried out in a two-step electroless plating process (pre-treatment of activation and plating). Uniform coating of the film with about $2{\~}3{\cal}um$ thickness was identified by SEM. High-frequency magnetic and microwave absorbing properties were determined in the rubber composites containing the Co-coated microspheres. Due to conductive and ferromagnetic behavior of the Co thin films, high dielectric constant and magnetic loss can be obtained in the microwave frequencies. Due to those electromagnetic properties, high absorption rate (25 dB) and thin matching thickness ($2.0{\~}2.5{\cal}mm$) are predicted in the composite layers containing the metal-coated microspheres of low density (about 0.84 g/cc) for the electromagnetic radiation in microwave frequencies.

Measurement and Analysis of the Dynamics of Peptide-Antibody Interactions Using an Ellipsometric Biosensor Based on a Silicon Substrate (실리콘 기판을 사용한 바이오센서와 회전 타원분광계를 이용한 펩타이드-항체 접합의 동특성 측정과 분석)

  • Lee, Geun-Jae;Cho, Hyun Mo;Jo, Jae Heung
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.1
    • /
    • pp.9-15
    • /
    • 2017
  • We precisely measured and analyzed the dynamics of peptide-antibody interactions, using an ellipsometric biosensor based on a silicon substrate. To reduce the signal error due to the imperfect flatness of the substrate for extremely low concentrations of peptide, we fabricated the biosensor with a silicon substrate coated with Dextran SAM, instead of a glass prism coated with a thin metallic thin film. At an injection speed of $100{\mu}l/min$ of buffer liquid, we detected the dynamics of antibody-Dextran SAM or peptide-antibody fixed on biosensor, respectively. We detected the dynamics of antibody-Dextran SAM interactions down to a low concentration of 5 ng per liter, and we precisely measured the dynamics of association and dissociation of peptide and antibody down to 100 nM of peptide. We obtained the rate constants for association and dissociation from fitting the data by using deduced dynamical equation. As a result, we obtained an equilibrium constant for dissociation of 97 nM of peptide-antibody complex, which belongs to Class I.