• 제목/요약/키워드: Mixing Tube

검색결과 188건 처리시간 0.022초

분자체 모델을 이용한 수종의 수산화칼슘 제재의 이온 용출에 관한 연구 (A STUDY OF IONIC DISSOCIATION ON VARIOUS CALCIUM HYDROXIDE PASTES USING MOLECULAR SIEVING MODEL)

  • 이경선;박광균;유윤정;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.632-643
    • /
    • 2002
  • The purpose of this study was two-fold. First was to evaluate whether the molecular sieving model was appropriate for ionic dissociation experiment. Second was to compare the dissociation of calcium and hydroxyl ions from five types of calcium hydroxide pastes (Pure calcium hydroxide paste, DT temporary $dressing^{\circledR},{\;}Metapaste^{\circledR},{\;}Chidopex^{\circledR},{\;}Metapex^{\circledR}$) in three vehicles (aqueous, viscous and oily) and the antibacterial effect. Each calcium hydroxide pastes was placed into 0.65ml tube with cap and then 15% polyacrylamide gel was placed onto calcium hydroxide pastes. After the gel was hardened, the tubes were filled with tridistilled water (pH 7.14) and closed with cap. The tubes were stored in $37^{\circ}C$ 100% incubator The pH reading and the concentration of calcium ions were taken at 1, 4, 7. 10, and 14 days. The brain heart infusion agar plates with S. mutans and A. actinomycetemcomitans were used far antibacterial activity test. Middle of agar plate was filled with the calcium hydroxide pastes. The plates were incubated at $37^{\circ}C$ and observations were made to detect the zones of inhibition. These data were evaluated statistically by use of the analysis of variance and duncan test. The results were as follows. 1. In fresh mixing state, the pH of five types of calcium hydroxide pastes were measured between 12.5 and 12.8. 2. The pH was increased in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (11.45) and DT temporary $dressing^{\circledR}$ (11.33) showed highest pH, followed by $Metapaste^{\circledR}$ (9.49), $Chidopex^{\circledR}$ (8.37) and $Metapex^{\circledR}$ (7.59) 3. Calcium was higher in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (137.29 mg%) and DT temporary $dressing^{\circledR}$ (124.6 mg%) showed highest value, followed by $Metapaste^{\circledR}$ (116.74 mg%), $Chidopex^{\circledR}$ (111.84 mg%) and $Metapex^{\circledR}$ (60.22 mg%). 4. The zones of bacterial inhibition were seen around all five types of calcium hydroxide pastes. $Chidopex^{\circledR}{\;}and{\;}Metapex^{\circledR}$ groups which include iodoform were observed significantly larger zone of inhibition in A. actinomycetemcomitans compared with the other calcium hydroxide groups (p<0.05) However, $Metapex^{\circledR}$ showed the least antibacterial effect on S. mutans compared with other groups (p<0.05). The molecular sieving model was found to be acceptable in dissociation experiment of hydroxyl and calcium ions when compared with the previous tooth model study. But this model was not appropriate for the antibacterial test.

산느타리(Pleurotus pulmonarius) 병·봉지재배에 적합한 배지조성 연구 (Study on suitable substrate formulation for bottle and bag cultivation of Pleurotus pulmonarius)

  • 이재홍;이남길;박영학;문윤기;정태성;권순배;김재록;김진원
    • 한국버섯학회지
    • /
    • 제12권4호
    • /
    • pp.275-279
    • /
    • 2014
  • 산느타리를 안정적으로 생산할 수 있는 배지를 개발하기 위하여 미루나무톱밥, 면실피, 면실박, 비트펄프, 콘코브 등 5종을 혼합하여 혼합비율별 6처리로 시험을 수행하여 배지조성별 화학성분, 균사생장속도 및 수량특성을 조사하였다. 배지조성별 화학성분 분석결과 pH는 대부분 pH 5.0 내외로서 큰 차이가 없었으나, V배지의 경우 다른 조성에 비하여 pH와 유기물 함량에 있어 각각 5.52, 29.07%로 높게 나타났다. 유기물대질소비는 IV배지가 30.53으로 가장 높았고, I, V, VI배지가 25정도를 나타냈으며, II, III배지는 20.68, 22.12로 낮은 값을 나타냈다. 시험관 칼럼배지를 이용해서 균사생장속도를 조사한 결과 균접종 28일 조사에서 향산 품종에서는 V배지가 105.0 mm로 가장 빠른 생장을 나타냈고, 호산 품종에서는 II번 배지가 114.3 mm로 가장 빨랐다. 병재배시 배지조성별 생육특성 조사결과 초발이소요일수는 3일, 생육일수는 4일로 모든 처리에서 동일하였고, 수량에 있어서는 호산품종의 경우 V배지가 병당 유효경수가 19.1개, 병당 수량이 198.4 g으로 가장 높은 수치를 나타냈으며, 향산 품종에서는 IV배지와 V배지가 각각 유효경수 15.3개, 14.4개, 수량은 161.1 g, 163.1 g으로 비슷하였다. 봉지재배에서 호산품종의 경우 초발이소요일수는 IV배지가 7일로서 가장 빨랐고 다음이 V, VI배지로서 8일, 그 다음이 I배지 9일 순이었다. 향산 품종에서 초발이소요일수는 I배지가 6일로서 가장 빨랐고 다음으로 IV, VI, V배지 순이었다. 그리고 생육일수는 4내지 5일로서 품종별, 배지조성별 차이가 없었다. 수량특성 조사결과 호산 품종의 경우 I배지가 봉지당 435.7 g으로 가장 높았고, 향산 품종에 있어서는 V배지가 463.5 g으로 높은 수량을 나타냈다.

다중채널 와전류탐상검사 장치 개발(II) (Development of a Multichannel Eddy Current Testing Instrument(II))

  • 이희종;남민우;조찬희;유현주;김인철
    • 비파괴검사학회지
    • /
    • 제31권5호
    • /
    • pp.552-559
    • /
    • 2011
  • 전자기유도(electromagnetic induction) 현상을 이용한 비파괴진단기법으로서 최근까지 와전류탐상기법, 교류장측정기법, 자속누설검사기법, 그리고 원격장검사기법 등이 개발되어 활용되고 있다. 이 기법 중 와전류탐상기법은 오늘날 발전설비, 화학, 조선 및 군수설비 등의 열교환기 전열관 비파괴검사에 널리 적용되고 있다. 와전류탐상검사 시스템의 구성은 기능별로 와전류신호 합성 모듈, 아날로그 모듈, 디지털 신호처리를 위한 아날로그-디지털 변환 모듈, 전원공급장치 및 신호취득 평가 프로그램 등으로 구성되며, 선행 연구(I)에서는 다중채널방식의 와전류탐상검사 시스템의 구성 요소 중 1차로 와전류신호 합성 모듈, 아날로그 모듈을 설계 개발하였으며, 2차로 와전류 신호 취득 평가 프로그램을 개발하였다. 2차 연구에서 개발한 와전류 신호취득 평가 프로그램의 운영체제는 "Windows 7"로서 국내 사용자를 위해 최적화 하였으며, 주요 특징은 검사자가 "setup wizard"를 이용하여 검사에 필요한 검사 조건 및 변수를 용이하게 설정하고 이를 이용하여 신호취득 및 평가를 수행할 수 있다. 본 논문에서는 개발된 와전류신호 수집 및 평가 프로그램의 구성과 각 기능을 설명하고자 한다.

능동포집과 확산포집법에 의한 일부합판제조업의 공정별 포름알데하이드 농도 비교 (Comparison of Active and Passive Sampling Methods for Formaldehyde Concentrations Among Workplaces in Some Plywood Industries)

  • 장미;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.17-27
    • /
    • 1996
  • This study was designed to survey exposure levels of formaldehyde among workplaces in some plywood industries and to compare three sampling methods including the impinger method(IM, NIOSH method No. 3500), the solid sorbent tube method(SS, NIOSH method No. 2541), and the passive bubbler monitor method(PB, SKC). The survey was conducted in seven particle board manufacturing factories, two resin manufacturing factories and two plywood manufacturing factories in Incheon area during the period from March 6 to April 20, 1995. The workplaces included were the hot/cold press, the roller/spreader, the soaking/drying, and the reaction/mixing areas. The results were as follows; 1. The average(GM, GSD) concentrations of formaldehyde by sampling methods were 0.11(4.43) ppm by IM, 0.27(2.03) ppm by SS, and 0.29(2.04) ppm by PB, respectively. The concentrations by 1M method were statistically very significantly lower than those of SS and PB methods, particularly at low air borne concentrations of formaldehyde (p<0.001). 2. The area average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.23(2.08) ppm from the press, 0.23(1.77) ppm from the spreader, 0.24(1.51) ppm from the soaking, and 0.46(1.96) ppm from the reaction areas, respectively. The personal average concentrations of formaldehyde by workplaces measured with PB bubblers were 0.30(1.77) ppm from the press, 0.33(1.54) ppm from the spreader, 0.36(1.46) ppm from the soaking, and 0.84(1.19) ppm from the reaction areas, respectively. 3. No statistically significant differences of formaldehyde concentrations among workplaces except the reaction area(p<0.001) were found. 4. Formaldehyde concentrations from personal samples were higher than those of from area sam pies in all workplaces studied. But no statistically significant differences of formaldehyde concentrations both area and personal samples were found. In conclusion, this study found that although formaldehyde concentrations in some plywood industries in Incheon area were below the regulatory limit of 1 ppm, they were over the limits recommended by NIOSH and ACGIH. This study also suggests that the impinger method may underestimate true formaldehyde concentrations. It implies that there will be more workplaces not meeting current regulatory limit if either the solid sorbent or passive bubbler methods were used instead of the impinger method. It is suggested that passive monitors will be a reasonable alternative for area and personal sampling of formaldehyde if the accuracy and validity of passive monitors be verified before use.

  • PDF

함정 적외선 신호저감 장치의 열 유동해석 연구 (A Study on the Heat Flow Analysis of Infra-Red Signature Suppression System for Naval Ship)

  • 윤석태;조용진;고대은
    • 한국산학기술학회논문지
    • /
    • 제18권11호
    • /
    • pp.740-746
    • /
    • 2017
  • 함정의 추진기와 발전기에 의해 발생하는 고온의 폐기가스와 연돌 주변 금속표면에서 방사되는 적외선 신호는 적 위협 무기체계의 표적이 되어 함의 생존성을 감소시키는 주 원인이 된다. 폐기가스와 연돌의 적외선 신호는 함정에 적외선 신호저감 장치(Infra-Red Signature Suppression system, IRSS)를 설치하여 감소시키고 있다. IRSS는 폐기가스에 난류 유동을 형성하는 이덕터, 폐기가스와 주변 공기가 혼합되는 믹싱 튜브, 외기와의 압력차를 이용하여 공기 필름을 형성하는 디퓨져 세 부분으로 구성된다. 본 연구는 적외선 신호저감 장치를 국내 독자기술로 개발하기 위한 기초 연구로 국외 선진 기술사에서 개발하여 국내 함정에 설치된 IRSS의 모형시험 조건을 분석하고 이를 기반으로 열 유동해석 연구를 수행하였다. 열 유동해석에서는 상용 수치해석 프로그램을 사용하였으며, 다양한 난류 이론 모델을 고려하여 결과를 비교 분석하였다. 해석의 주요 결과로는 이덕터 입구와 디퓨져 출구에서의 폐기가스 온도 및 속도, 그리고 디퓨져의 금속표면 온도를 구하였으며 모형시험의 계측 결과와 잘 부합함을 확인하였다.

브란운관의 후면유리 폐기물을 이용한 제올라이트 합성

  • 장영남;배인국;채수천;류경원
    • 기술사
    • /
    • 제34권2호
    • /
    • pp.167-173
    • /
    • 2001
  • 브라운관 후면유리 연마 후 발생되는 고상의 유리폐기물을 재활용을 위해, A형 제올라이트의 최적합성조건을 규명하고 생성된 제올라이트의 제반 특성을 기존의 상용 제올라이트와 비교하였다. 테프론 반응용기에 고규산질 알카리용액, NaAlO$_2$그리고 브라운관 유리폐기물 등 3가지 출발물질을 혼합하고, 80∼95$^{\circ}C$ 범위에서 가열하여 제올라이트 Na-A를 열수조건하에서 결정화시켰다. 고규산질 알카리 용액은 자연산 규석을 35$0^{\circ}C$, 1500 기압하에서, NaAlO$_2$는 NaOH와 Al(OH)$_3$시약을 95$^{\circ}C$에서 2∼3시간 가열하여 $Na_2$O/Al$_2$O$_3$=1.4, $H_2O$/$Na_2$O=8이 되도록 각각 합성하여 출발물질로 사용하였다. 브라운관 유리 폐기물과 고규산질 알카리 용액의 혼합비율 약 1:10∼1:13의 범위에서 Al-공급원으로서 1.5∼2.5N의 NaAlO$_2$를 혼합하였을 때 양호한 A-형 제올라이트 결정이 생성되었다. 합성된 Na-A는 하이드록시소달라이트 등과 같은 불순물이 없는 단일상이었으며, 결정형태는 입방 십이면체 (cubo-dodecahedral)형이었고 결정의 1∼2 $\mu$의 균질한 입도로 분포하였다. Ca+ 양이온교환용량은 215∼220 mequivalent/100 g이었다.

전기활성 고분자 전극 및 구동기에 관한 실험적 연구 (An Experimental Study for Electro-active Polymer Electrode and Actuator)

  • 이준만;류상렬;이동주;임정걸
    • Composites Research
    • /
    • 제26권5호
    • /
    • pp.289-294
    • /
    • 2013
  • 고분자 기지에 희석제의 첨가로 CNT 및 CB 입자의 분산성 향상 및 연질의 전극을 만들고자하였다. 희석제, CNT 및 CB 함유량에 따른 연질 전극재료의 전기적 및 기계적 특성을 평가하였다. 전극재료로서 최적의 혼합조건은 기지 (KE-12)를 기본으로 희석제 80, CNT 3.5 그리고 CB 18 (phr)이었다. 이때의 비저항 값은 73 (${\Omega}{\cdot}cm$)이었고, 인장강도와 인장탄성율 그리고 신장율은 각각 0.45 MPa, 0.21 MPa, 184%였다. 또한 최적화된 전극과 탄성체를 이용하여 간단한 구조의 구동기를 제작하여 그 특성을 평가하였다. 작동 전압 25 kV에서 탄성체 KE-12는 2.24 mm의 변위가 발생되었고, 희석제가 50 (phr) 혼합된 KE-12는 4.05mm의 변위가 발생되었다. 희석제 50 (phr) 혼합된 KE-12는 3M의 4910과 같은 탄성계수를 나타내지만, 더 높은 변위를 보였다. 동일한 재료 (KE-12)의 전극과 탄성체로 제작된 구동기는 피로수명 및 응용에 많은 장점이 있을 것으로 보인다.

함정 적외선 신호 감소를 위한 폐기관의 디퓨져 설계에 관한 연구 (A Study on the Diffuser Design of Exhaust Pipes for the Infra-Red Signature Reduction of Naval Ship)

  • 윤석태;조용진;고대은
    • 한국산학기술학회논문지
    • /
    • 제18권12호
    • /
    • pp.793-798
    • /
    • 2017
  • 현대의 함정에서는 추진 기관에서 생성된 고온의 폐기가스와 가열된 폐기관의 금속표면온도를 저감하기 위해 적외선 신호저감 장치(Infra-red Signature Suppression system, IRSS)를 설치하고 있다. 국내 함정에 탑재된 일반적인 IRSS는 이덕터, 믹싱튜브 그리고 디퓨져로 구성되며, 이 중 디퓨져는 금속표면에 내기 외기의 압력차에 의한 공기 막을 생성시켜 온도를 저감시키는 역할을 한다. 본 연구에서는 국외 선진 기술사에서 설계한 IRSS의 디퓨져 형상을 분석하여 설계 변수를 선정하였으며, 분석 조건을 줄이면서 설계 변수의 특성을 효과적으로 파악 할 수 있는 다구치 실험계획법을 통해 IRSS 디퓨져의 성능에 영향을 미치는 설계 변수의 특성을 검토하였다. 디퓨져의 성능분석에는 선행 연구에서 정립한 열 유동해석 기술을 활용하였다. IRSS의 성능평가에는 함정 적외선 신호의 세기와 직접적으로 관련되는 디퓨져 출구에서의 폐기가스 온도와 금속표면온도의 면적평균 값을 기준으로 하였으며, 폐기가스의 온도는 디퓨져 출구의 직경 변화에 크게 영향을 받고, 디퓨져 금속표면의 온도는 디퓨져 링의 개수 변화에 크게 영향 받음을 확인하였다.

브라운관의 후면유리 폐기물을 이용한 제올라이트 합성 (Synthesis of Na-A Type of Zeolite from Funnel-Glass Waste)

  • 장영남;배인국;채수천;류경원
    • 자원환경지질
    • /
    • 제34권2호
    • /
    • pp.167-173
    • /
    • 2001
  • 브라운관 후면유리 연마 후 발생되는 고상의 유리폐기물을 재활용을 위해, A형 제올라이트의 최적합성조건을 규명하고 생성된 제올라이트의 제반 특성을 기존의 상용 제올라이트와 비교하였다. 테프론 반응용기에 고규산질 알카리용액, NaAlO$_2$그리고 브라운관 유리폐기물 등 3가지 출발물질을 혼합하고, 80~95$^{\circ}C$ 범위에서 가열하여 제올라이트 Na-A를 열수조건하에서 결정화시켰다. 고규산질 알카리 용액은 자연산 규석을 35$0^{\circ}C$, 1500 기압하에서, NaAlO$_2$는 NaOH와 Al(OH)$_3$시약을 95$^{\circ}C$에서 2~3시간 가열하여 $Na_2$O/Al$_2$O$_3$=1.4, $H_2O$/$Na_2$O=8이 되도록 각각 합성하여 출발물질로 사용하였다. 브라운관 유리 폐기물과 고규산질 알카리 용액의 혼합비율 약 1:10~1:13의 범위에서 Al-공급원으로서 1.5~2.5N의 NaAlO$_2$를 혼합하였을 때 양호한 A-형 제올라이트 결정이 생성되었다. 합성된 Na-A는 하이드록시소달라이트 등과 같은 불순물이 없는 단일상이었으며, 결정형태는 입방 십이면체 (cubo-dodecahedral)형이었고 결정의 1~2 $\mu$의 균질한 입도로 분포하였다. $Ca^{+}$ 양이온교환용량은 215~220 mequivalent/100 g이었다.

  • PDF

시간영역 광전자파 분석기 (Automatic TDR System)를 이용한 오염물질의 거동에 관한 연구: 오염물질 운송개념 (Application of an Automated Time Domain Reflectometry to Solute Transport Study at Field Scale: Transport Concept)

  • 김동주
    • 자원환경지질
    • /
    • 제29권6호
    • /
    • pp.713-724
    • /
    • 1996
  • 현장에서의 주요 운송 메카니즘을 연구하기 위하여 시간별 잔존수 농도분포곡선 자료를 이용하였다. 운송개념을 대표하는 모델로서 2개의 상반된 가설에 근기한 모델, 즉 CDE와 CLT모델을 사용하였으며 파라미터 추정을 위하여 깊이별 평균농도자료에 최적화기법을 적용하였으며 잔존수 농도의 도달시간을 나타내는 확율밀도함수를 이용하여 모멘트해석도 시행되었다. 모멘트 해석결과 잔존수농도의 1차 및 2차 시간 모멘트는 침출수농도의 것들보다 크게 나타났다. 또한 시간 모멘트를 이용하여 오염물질 운송시간의 변이도와 확산 파라미터도 도출되었다. 변이도 및 확산계수와 운송거리간의 상관관계는 침출수농도 및 잔존수농도에 대해서 동일하게 나타났다. 이러한 관계를 이용하여 2가지 모델을 검정하였으나 운송거리에 따른 운송파라미터의 불규칙한 변화로 확정적 결론을 얻을 수 없었다. 따라서 첫 번째 깊이에서 얻은 파라미터를 이용하여 다른 깊이에서의 오염물질 운송 방식을 예측하여 실측자료와 비교하여 각 모델을 검정하였다. 그 결과 CLT 모델이 CDE 모델보다 현장실측자료에 근접하였다. 이는 오염물질이 이동함에 따라 완전한 혼합이 발생하는 것이 아니라 상관흐름 즉, "오염물질이 각 층을 통과할 때 빠른 물질은 빠르게 느린 물질은 지속적으로 느리게 움직인다"는 사실을 뒷받침한다고 볼 수 있다. 특히 첨두농도에 대한 CDE 모델의 과대예측은 오염물질 확산의 과소평가에 기인하는 것으로 나타났다.

  • PDF