• 제목/요약/키워드: Mixing Tube

검색결과 187건 처리시간 0.023초

이상 유동 수치해석을 이용한 기포 구동 생물 반응기 내부 최적 구조에 관한 연구 (Study on optimum structure of air-lift bio-reactor using numerical analysis of two-phase flow)

  • 김산;정지홍;이재원;손동기;고한서
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.24-31
    • /
    • 2019
  • Recently, an air-lift bio-reactor operated by micro bubbles has been utilized to product hydrogen fuel. To enhance the performance, characteristics of hydrodynamics inside the bio-reactor were analyzed using a numerical simulation for two-phase flow. An Eulerian model was employed for both of liquid and gas phases. The standard k-ε model was used for turbulence induced by micro bubbles. A Population Balance Model was employed to consider size distribution of bubbles. A hollow cylinder was introduced at the center of the reactor to reduce a dead area which disturbs circulation of CO bubbles. An appropriate diameter of the draft tube and hollow cylinder were optimized for better performance of the bio-reactor. The optimum model could be obtained when the cross-sectional area ratio of the hollow cylinder to the reactor, and the width ratio of the riser to the downcomer approached 0.4 and 3.5, respectively. Consequently, it is expected that the optimum model could enhance the performance of the bio-reactor with the homogeneous distribution and higher density of CO, and more effective mixing.

열변성 물질을 이용한 지하수 온도 측정용 광섬유 온도센서의 특성분석 (Characteristic analysis of a thermochromic material based fiber-optic temperature sensor for measuring temperature of subsurface water)

  • 서정기;유욱재;조동현;장경원;허지연;이봉수;고용권
    • 센서학회지
    • /
    • 제18권6호
    • /
    • pp.467-474
    • /
    • 2009
  • In this study, we describe the feasibility of developing a fiber-optic temperature sensor using a thermochromic material such as 2,4,5-triphenylimidazole or also called Lophine. A sensor-tip is fabricated by mixing of a Lophine powder, which has a non-toxic and hydrophobic characteristics, and an epoxy resin. The temperature change in the sensor-tip gives rise to a change in the optical absorbance of the Lophine, and the transmittance of a light through the Lophine is also changed. We have measured the intensities of modulated lights due to the change of optical absorbance of the Lophine by using of a photo-multiplier tube(PMT). The relationships between the temperatures and the output voltages of PMT are determined to measure the temperature of water. The measurable temperature range of the fiber-optic sensor is from 5 to $30^{\circ}C$.

바륨 현탁액과 메틸셀룰로스(Methylcellulose)를 사용한 변형 상부위장관조영술 :전통적 바륨조영술과의 비교 (Modified Upper Gastrointestinal Study Using Methylcellulose After Administration of Barium Suspension : Comparison with Conventional Series)

  • 이기창;최민철;서민호;정주현;윤정희
    • 한국임상수의학회지
    • /
    • 제17권2호
    • /
    • pp.411-415
    • /
    • 2000
  • For comparison with conventional barium-gastrointestinal study, modified method using barium and methylcellulose was performed in 16 normal dogs (4-8 kg) divided into two groups. The group 1 received 8ml/kg of 40% w/v barium suspension only, and group 2 had taken 15 ml/kg of 0.6% w/v methylcellulose after administration 4 ml/kg of 40% w/v barium suspension by feeding tube. The barium suspension was prepared mixing full strength-barium suspension with water and methylcellulose solution was produced by blending methylcellulose sterilized water Sequential radiographs, lateral and ventrodorsal projections were obtained at 5 minute, 20 minute,40 minute. 60 minute and every 30 minutes thereafter, until the contrast is seen in the large intestine Inage qual- ity was rated by three veterinary radiologists as " poor" " fair ". "good", or "excellent" We analyzed the relationship between image quality,, transit time. Between two techniques, the modified method with 4ml of 40% w/v barium suspension and 15 ml of 0.6% w/v methylcellulose showed much better image quality ["excellent" result in 7 of the 8 subjects (88%)] and shorter transit time (107 minutes) toe the cecum. In addition, the best image quality was obtained at 20 and 40 minutes after admin-istration of contrast agent. It call be concluded the modified gastrointestinal study using methylcel-lulose after administration of barium suspension was a simple technique and easily improved the image quality and diagnostic accuracy of gstrointestinal disorders in small animal.racy of gstrointestinal disorders in small animal.

  • PDF

비예혼합화염과 예혼합화염의 속도 섭동에 따른 응답 특성 (How to Prepare the Manuscript for Submission to the Proceedings of KSPE Conference)

  • 안명근;김태성;윤영빈
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2017년도 제48회 춘계학술대회논문집
    • /
    • pp.612-616
    • /
    • 2017
  • 비예혼합합화염과 예혼합화염의 화염응답특성을 속도섭동을 다양하게 변경하며 실험하였다. 연료로는 수소($H_2$)/메탄($CH_4$)을 50/50 %로 혼합한 혼합연료를 사용하였으며 산화제로는 공기를 사용하였다. OH 자발광(OH fluorescence)을 이용하여 화염이미지를 계측하였으며 PMT(Photo Multiplier Tube)를 이용하여 열 방출량을 계측하였다. 계측된 이미지는 MatLab 코드를 이용하여 수치화하였다. 예혼합화염의 결과에서는 진폭이 증가할수록 화염섭동이 증가하는 경향성을 보았으며 진폭에 따라서 화염전달 함수의 게인 값이 선형적인 거동을 하는 것을 관찰하였다. 비예혼합화염의 화염길이는 진폭이 증가할수록 짧아지는 것을 관찰하였고 게인 값은 진폭에 비선형적인 거동을 하는 것을 확인하였다.

  • PDF

하천 혼합 해석을 위한 2차원 이송-분산 모형의 종분산계수 예측 (Predicting Longitudinal Dispersion Coefficient of Two-dimensional Model for Analysis of Mixing in Natural Streams)

  • 서일원;최황정
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2015년도 학술발표회
    • /
    • pp.75-75
    • /
    • 2015
  • 오염원과 취수장이 동일 구간 내에 공존하는 국내하천의 특성상, 하천 평면 내에서 오염물의 거동 및 혼합 특성을 보다 정확하게 해석하기 위해서는 2차원 이송-분산 모형의 적용이 필요하다. 이를 위해서는 2차원 모형의 주요 매개변수인 종분산계수와 횡분산계수의 적절한 입력이 매우 중요하다. 하지만 국내외적으로 횡분산계수에 대한 연구는 많이 진행된 반면, 현재까지 종분산계수에 대한 연구는 충분히 이루어지지 않은 실정이다. 분산계수를 결정하는 방법에는 실측된 농도 자료의 유무에 따라 크게 두 가지로 분류된다. 실측된 농도 자료가 없는 경우, 이론식이나 경험식을 이용하는 방법이 있다. 반면에 추적자 실험 등을 수행하여 실측된 농도 자료가 있는 경우, 모멘트법 또는 추적법을 적용하여 농도-시간 분포 곡선으로부터 분산계수를 계산하는 것이다. 모멘트법은 임의 지점에서 농도의 횡분포를 통해 얻을 수 있는 2차 모멘트의 종방향 변화율이 횡분산계수와 비례한다는 원리를 이용한 것이며, 추적법은 상류부의 관측된 농도를 입력자료로 하여 하류부의 농도를 계산한 후 계산된 농도와 실측된 하류부 농도의 비교를 통해 분산계수를 산정하는 방법이다. 본 연구에서는 불규칙한 단면 형상을 가지는 자연하천에서의 2차원 종 횡분산계수를 산정하기 위해서 Baek & Seo(2010)가 제안한 2차원 유관추적법(2D Stream-tube Routing Procedure)을 적용하였다. 본 연구에서는 국내 자연하천 중 다양한 사행형태를 갖으며 수질오염 사고의 위험이 높은 구간을 선정하고, 추적자로서 Rhodamine WT를 이용하여 현장실험을 수행하였다. 실험에서 수집된 수리량 및 농도자료로부터 추적자의 2차원적 거동을 분석하였으며, 2차원 유관추적법을 적용하여 종분산계수를 산정하였다. 그 결과 하폭 대 수심비(W/H)와 마찰손실관련 무차원변수(U/U*)의 증가에 따라 종분산계수가 증가됨을 확인 할 수 있었다. 본 연구에서 산출된 종분산계수와 선행 연구에서 수집된 자료를 이용하여 추정식을 개발하였다. 차원해석을 통해 무차원 종분산계수에 영향을 미치는 무차원 인자를 선별하고 회귀분석을 이용하여 종분산계수 추정식을 유도하였다. 추정식을 이용하여 산정한 종분산계수의 범위는 Elder (1959)가 제안한 이론값보다 약 10배 정도로 크게 나타났다. 혼합 특성이 밝혀지지 않은 자연하천에 2차원 확산모형을 적용하고자 할 때 본 연구에서 개발된 추정식으로부터 계산된 종분산계수를 사용할 수 있을 것이다.

  • PDF

Development of a Novel Multiple Cross-Linking Spiral Amplification for Rapid and Sensitive Detection of HPV16 DNA

  • Zhang, Donghong;Liu, Dongliang;Liu, Bing;Ma, Xiulan
    • Journal of Microbiology and Biotechnology
    • /
    • 제31권4호
    • /
    • pp.610-620
    • /
    • 2021
  • There has been increasing interest in the head and neck squamous cell carcinoma (HNSCC) that is caused by high-risk human papillomavirus (HR-HPV) and has posed a significant challenge to Otolaryngologists. A rapid, sensitive, and reliable method is required for the detection of HR-HPV in clinical specimens to prevent and treat HPV-induced diseases. In this study, a multiple cross-linking spiral amplification (MCLSA) assay was developed for the visual detection of HPV-16. In the MCLSA assay, samples were incubated under optimized conditions at 62℃ for 45 min, and after mixing with the SYBR Green I (SGI) dye, the positive amplicons showed bright green fluorescence while the negative amplicons exhibited no obvious change. The specificity test revealed that the developed MCLSA technique had high specificity and could effectively distinguish all five HPV-16 strains from other pathogenic microorganisms. In terms of analytical sensitivity, the limit of detection (LoD) of MCLSA assay was approximately 5.4 × 101 copies/tube, which was 10-fold more sensitive than loop-mediated isothermal amplification (LAMP) and RT-PCR. The detection results of laryngeal cancer specimens collected from 46 patients with suspected HPV infection in the Liaoning region demonstrated that the positive detection rates of MCLSA and hybridized capture 2 kit were 32.61% (15/46). The true positive rate of the MCLSA assay was higher than that of RT-PCR (100% vs. 93.33%) and LAMP (100% vs. 86.67%). Therefore, the MCLSA assay developed in the present study could be a potentially useful tool for the point-of-care (PoC) diagnosis of HR-HPV, especially in resource-limited countries.

Structural Behavior of Mixed $LiMn_2O_4-LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ Cathode in Li-ion Cells during Electrochemical Cycling

  • 윤원섭;이상우
    • 한국재료학회:학술대회논문집
    • /
    • 한국재료학회 2011년도 춘계학술발표대회
    • /
    • pp.5-5
    • /
    • 2011
  • The research and development of hybrid electric vehicle (HEV), plug-in hybrid electric vehicle (PHEV) and electric vehicle (EV) are intensified due to the energy crisis and environmental concerns. In order to meet the challenging requirements of powering HEV, PHEV and EV, the current lithium battery technology needs to be significantly improved in terms of the cost, safety, power and energy density, as well as the calendar and cycle life. One new technology being developed is the utilization of composite cathode by mixing two different types of insertion compounds [e.g., spinel $LiMn_2O_4$ and layered $LiMO_2$ (M=Ni, Co, and Mn)]. Recently, some studies on mixing two different types of cathode materials to make a composite cathode have been reported, which were aimed at reducing cost and improving self-discharge. Numata et al. reported that when stored in a sealed can together with electrolyte at $80^{\circ}C$ for 10 days, the concentrations of both HF and $Mn^{2+}$ were lower in the can containing $LiMn_2O_4$ blended with $LiNi_{0.8}Co_{0.2}O_2$ than that containing $LiMn_2O_4$ only. That reports clearly showed that this blending technique can prevent the decline in capacity caused by cycling or storage at elevated temperatures. However, not much work has been reported on the charge-discharge characteristics and related structural phase transitions for these composite cathodes. In this presentation, we will report our in situ x-ray diffraction studies on this mixed composite cathode material during charge-discharge cycling. The mixed cathodes were incorporated into in situ XRD cells with a Li foil anode, a Celgard separator, and a 1M $LiPF_6$ electrolyte in a 1 : 1 EC : DMC solvent (LP 30 from EM Industries, Inc.). For in situ XRD cell, Mylar windows were used as has been described in detail elsewhere. All of these in situ XRD spectra were collected on beam line X18A at National Synchrotron Light Source (NSLS) at Brookhaven National Laboratory using two different detectors. One is a conventional scintillation detector with data collection at 0.02 degree in two theta angle for each step. The other is a wide angle position sensitive detector (PSD). The wavelengths used were 1.1950 ${\AA}$ for the scintillation detector and 0.9999 A for the PSD. The newly installed PSD at beam line X18A of NSLS can collect XRD patterns as short as a few minutes covering $90^{\circ}$ of two theta angles simultaneously with good signal to noise ratio. It significantly reduced the data collection time for each scan, giving us a great advantage in studying the phase transition in real time. The two theta angles of all the XRD spectra presented in this paper have been recalculated and converted to corresponding angles for ${\lambda}=1.54\;{\AA}$, which is the wavelength of conventional x-ray tube source with Cu-$k{\alpha}$ radiation, for easy comparison with data in other literatures. The structural changes of the composite cathode made by mixing spinel $LiMn_2O_4$ and layered $Li-Ni_{1/3}Co_{1/3}Mn_{1/3}O_2$ in 1 : 1 wt% in both Li-half and Li-ion cells during charge/discharge are studied by in situ XRD. During the first charge up to ~5.2 V vs. $Li/Li^+$, the in situ XRD spectra for the composite cathode in the Li-half cell track the structural changes of each component. At the early stage of charge, the lithium extraction takes place in the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component only. When the cell voltage reaches at ~4.0 V vs. $Li/Li^+$, lithium extraction from the spinel $LiMn_2O_4$ component starts and becomes the major contributor for the cell capacity due to the higher rate capability of $LiMn_2O_4$. When the voltage passed 4.3 V, the major structural changes are from the $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, while the $LiMn_2O_4$ component is almost unchanged. In the Li-ion cell using a MCMB anode and a composite cathode cycled between 2.5 V and 4.2 V, the structural changes are dominated by the spinel $LiMn_2O_4$ component, with much less changes in the layered $LiNi_{1/3}Co_{1/3}Mn_{1/3}O_2$ component, comparing with the Li-half cell results. These results give us valuable information about the structural changes relating to the contributions of each individual component to the cell capacity at certain charge/discharge state, which are helpful in designing and optimizing the composite cathode using spinel- and layered-type materials for Li-ion battery research. More detailed discussion will be presented at the meeting.

  • PDF

하이브리드 콘크리트 보수재료로 보수된 흄관의 휨 거동 평가 (An Evaluation of Flexural Behavior of Fume Pipe Repaired by Hybrid Concrete Repair Materials)

  • 유성원;최영철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권6호
    • /
    • pp.92-98
    • /
    • 2019
  • 본 연구에서는 기존콘크리트와의 부착성능 및 수밀성을 향상하기 위해 기존의 현장에서 사용하는 초속경 시멘트에 PVA 분말수지, 나일론 섬유를 혼입한 보수재료를 개발하고 개발된 보수재료로 보수된 흄관의 보수 후 휨거동 평가를 수행하였다. 주요 실험변수는 PVA 분말수지, 나일론 섬유 혼입률 및 손상유형이며, 성능 실험으로는 압축강도와 보수재료 후 휨거동평가를 수행하였으며 개발된 보수재료는 PVA 분말수지 혼입량이 증가할수록 압축강도가 감소하는 경향이 나타났으며, 모든 배합에서 보수재료의 요구 성능을 충분히 만족하는 것으로 나타났다. 보수된 관 시험체들의 휨강도 실험결과, 나일론 섬유를 혼입하고 PVA분말을 적정량을 첨가하여야 보수재료의 성능이 최대가 되는 것으로 나타났다. 모든 시험체들의 휨거동은 다소 철근비가 작은 구조부재에서 나타나는 휨거동 양상을 보이는 것으로 나타나, 국내의 흄관에 배근되는 철선량이 다소 부족함을 추정할 수 있었다. 즉, 철선의 배근량이 다소 적어 콘크리트와 철선의 거동이 극한상태에 도달하기 전에 콘크리트에 균열이 발생되고 곧바로 콘크리트의 인장강도를 초과하여 파괴되는 것을 확인할 수 있었다.

분자체 모델을 이용한 수종의 수산화칼슘 제재의 이온 용출에 관한 연구 (A STUDY OF IONIC DISSOCIATION ON VARIOUS CALCIUM HYDROXIDE PASTES USING MOLECULAR SIEVING MODEL)

  • 이경선;박광균;유윤정;이승종
    • Restorative Dentistry and Endodontics
    • /
    • 제27권6호
    • /
    • pp.632-643
    • /
    • 2002
  • The purpose of this study was two-fold. First was to evaluate whether the molecular sieving model was appropriate for ionic dissociation experiment. Second was to compare the dissociation of calcium and hydroxyl ions from five types of calcium hydroxide pastes (Pure calcium hydroxide paste, DT temporary $dressing^{\circledR},{\;}Metapaste^{\circledR},{\;}Chidopex^{\circledR},{\;}Metapex^{\circledR}$) in three vehicles (aqueous, viscous and oily) and the antibacterial effect. Each calcium hydroxide pastes was placed into 0.65ml tube with cap and then 15% polyacrylamide gel was placed onto calcium hydroxide pastes. After the gel was hardened, the tubes were filled with tridistilled water (pH 7.14) and closed with cap. The tubes were stored in $37^{\circ}C$ 100% incubator The pH reading and the concentration of calcium ions were taken at 1, 4, 7. 10, and 14 days. The brain heart infusion agar plates with S. mutans and A. actinomycetemcomitans were used far antibacterial activity test. Middle of agar plate was filled with the calcium hydroxide pastes. The plates were incubated at $37^{\circ}C$ and observations were made to detect the zones of inhibition. These data were evaluated statistically by use of the analysis of variance and duncan test. The results were as follows. 1. In fresh mixing state, the pH of five types of calcium hydroxide pastes were measured between 12.5 and 12.8. 2. The pH was increased in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (11.45) and DT temporary $dressing^{\circledR}$ (11.33) showed highest pH, followed by $Metapaste^{\circledR}$ (9.49), $Chidopex^{\circledR}$ (8.37) and $Metapex^{\circledR}$ (7.59) 3. Calcium was higher in all five types of calcium hydroxide pastes compared with control group. In 14 days, Pure calcium hydroxide paste (137.29 mg%) and DT temporary $dressing^{\circledR}$ (124.6 mg%) showed highest value, followed by $Metapaste^{\circledR}$ (116.74 mg%), $Chidopex^{\circledR}$ (111.84 mg%) and $Metapex^{\circledR}$ (60.22 mg%). 4. The zones of bacterial inhibition were seen around all five types of calcium hydroxide pastes. $Chidopex^{\circledR}{\;}and{\;}Metapex^{\circledR}$ groups which include iodoform were observed significantly larger zone of inhibition in A. actinomycetemcomitans compared with the other calcium hydroxide groups (p<0.05) However, $Metapex^{\circledR}$ showed the least antibacterial effect on S. mutans compared with other groups (p<0.05). The molecular sieving model was found to be acceptable in dissociation experiment of hydroxyl and calcium ions when compared with the previous tooth model study. But this model was not appropriate for the antibacterial test.