• Title/Summary/Keyword: Mixing Tube

Search Result 188, Processing Time 0.027 seconds

Performance Tests on a Solar Water Heating System in Thermosyphonic Flow (열사이폰식 태양열 온수시스템의 성능실험)

  • Kim, Doo-Chun;Park, Seung-Duk
    • The Magazine of the Society of Air-Conditioning and Refrigerating Engineers of Korea
    • /
    • v.9 no.2
    • /
    • pp.93-103
    • /
    • 1980
  • A small domestic solar water heating system in thermosyphonic flow was tested in Seoul. The system consisted of four flat plate aluminium roll bond type collectors of total effective area $3.28m^2$ and a $280{\iota}$ storage tank. It was tilted $52^{\circ}$ relative to the horizon. And the collector plate, collector tube and storage tank were equiped with 14 thermocouples. As the results, the following facts were found; 1) To provide water at $55^{\circ}C$ for a family of four in Seoul, a collector area of $3-4m^2$ and a storage capacity of $180{\iota}- 200{\iota}$ are suggested. And this system can supply hot water at above $45^{\circ}C$ day about. 2) In the late afternoon hours, it might be advantageous to stop the flow in the system as heat losses to the environment increase unduly. 3) Without any hot water consumption throughout the day, water temperature distributions inside the storage tank was found almost linear. This indicates essentially no mixing inside the storage tank. 4) In case of a small domestic solar water heating system, it is better to employ a single transparent cover rather than double one.

  • PDF

A Study on the characteristic analysis and optimization according to Ballast design of Induction Lamp (고출력 무전극램프의 점등회로 설계를 통한 특성분석 및 최적화에 관한 연구)

  • Chung, Young-Il;Jung, Dae-Chul;Park, Dae-Hee;Kim, Yong-Kab
    • The Journal of Korea Institute of Information, Electronics, and Communication Technology
    • /
    • v.10 no.1
    • /
    • pp.31-37
    • /
    • 2017
  • In this paper, we implemented for the development of a high output induction lamp system, which lamp design is optimized by gas type, mixing ratio, pressure and discharge tube size, amalgam type and mixing ratio, and characteristics of ferrite core in the lamp. It's the circuit design by improving the power factor and efficiency according to the driving method, which has analyzing the characteristics according to the waveform and frequency. Finally, luminaries design part for applying the optimal lighting system considering the surrounding environment, the characteristics of the lighting circuit for electrodeless lamp has analyzed and the improvement has been proceeded. In conclusion, the driving frequency has optimized at 135kHz with degrading $7{\sim}10^{\circ}C$ based on the results of the optical characteristics of the induction lamp on peak noise FET(Q3,Q4) damage.

Evaluation of luminance performance of scintillating film for monitoring the position of a radioactive source in an NDT apparatus (비파괴검사 장치 내 방사선원 위치감시용 섬광필름의 발광성능 평가)

  • Lee, Kyung-Jin;Yun, Jeong-Ick;Park, Byung-Gi;Kim, Sin;Lee, Bong-Soo
    • Journal of radiological science and technology
    • /
    • v.28 no.1
    • /
    • pp.13-17
    • /
    • 2005
  • In domestic nondestructive testing(NDT) field, there have recently been radiation exposure accidents due to a disregard for confirmation of the position of radioisotope during the test. In order to prevent these kinds of accidents, a scintillating film has been developed. The scintillating film that can convert gamma-ray to visible light has a function of the position detection of radioisotope in a opaque guide tube of an NDT apparatus. The aim of this study is to enhance the visibility performance of the scintillating film and find out the best configuration of the scintillating film. In order to find appropriate materials for the scintillating film, various inorganic scintillating materials were evaluated in this work. An absolute luminance of the scintillating films was measured by luminance meter for evaluation of visibility performance. Ir-192 gamma projector was used for NDT apparatus. The experiment shows that the scintillating film with reflective layer was the more effective performance for visibility. The higher mixing ratio of scintillating material to binding material, the higher luminance was measured. $Gd_2O_2S(Tb)$ inorganic powder as the scintillating materials had the best performance for visibility of the scintillating film. The developed scintillating film helps to ensure safer environment to the operators.

  • PDF

Glomerular Filtration Rate Test Methods and Guidelines (Glomerular Filtration Rate 검사방법 및 가이드라인)

  • Park, Min-Ho;Lee, Ha-Young;Ryu, Hwa-Jin;Yoo, Tae-Min;Noh, Gyeong-Woon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.22 no.2
    • /
    • pp.97-100
    • /
    • 2018
  • Purpose The glomerular filtration rate (GFR) test is an important indicator of glomerular filtration and has been used to test renal function and the extent of its function. The GFR test is performed by intravenous injection of radioactive medicines made of $^{51}Cr$-EDTA, and blood concentration is measured by taking blood according to the elapsed time. also, PET-CT, bone scan, transfusion and so on will affect the outcome. Therefore, we will improve the quality of the test by providing guidelines for the GFR test for more accurate testing. Materials and Methods 5 mL of physiological saline solution and 2 mL of $^{51}Cr$-EDTA solution are used to make 5 mL of the radiopharmaceutical solution to be injected into the patient. First, the syringe weight is measured before the injection, and then the radioactive medicine is injected into the patient's vein and the syringe weight is measured after the injection. Blood sampling is performed twice in total. In adults, blood is collected 3 hours / 5 hours after injection and in children 2 hours / 5 hours after injection. The blood sample is centrifuged at 3300 rpm for 5 minutes. Standard solution is prepared by filling diluent water up to the scale indicated in the 200-mL volumetric flask, discarding $500{\mu}L$, injecting $500{\mu}L$ of GFR reagent and mixing well. $500{\mu}L$ each of the standard solution is dispensed into two test tubes, and $500{\mu}L$ of each of the plasma samples collected in time is dispensed into two test tubes and measured with a Cobra Counter. Results At present, the reference range applied in this study is $119.5{\pm}30.3ml/min/1.73m2$ for males and $125.2{\pm}28.2ml/min/1.73m^2$ for females. Conclusion The GFR test is conducted using radioactive medical products. GFR testing is performed as a scheduled test, but PET-CT, dialysis and transfusion, which may affect GFR testing, may be scheduled during GFR testing. Therefore, we could get accurate GFR test results by notifying the ward and department beforehand when booking.

Heavy Metal Adsorption Characteristics and Produced of Food Waste Activated Carbon (음식물류 폐기물 활성탄의 제조 및 중금속 흡착특성)

  • Lee, Jun-Hee;Lee, Seung-Chul;Ju, Min;Kim, Ji-Hye;Lee, Don-Gil
    • Journal of Environmental Science International
    • /
    • v.24 no.12
    • /
    • pp.1601-1608
    • /
    • 2015
  • This study evaluates heavy metal(Cu and Cr) adsorption characteristics produced from food waste charcoal extracted in an optimal operation condition after analyzing activated charcoal of iodine adsorption and heavy metals that derived from an activation process of carbide by the developed by-products of food waste treatment facility using the methods from previous studies. As experiment apparatus, this study used a tube-shaped high temp furnace. The mixing ratio of by-products of food waste treatment facility, carbide, and activation component($ZnCl_2$) was 1:1. The experiment was proceeded as adjusting the activation temperature from 400 to $800^{\circ}C$ and activation time from 30 to 120 minutes. The optimal activation condition for iodine absorption was 90 minutes at $700^{\circ}C$ and by using the produced food waste charcoal, this study conducted an experiment on absorption of heavy metals (Cu and Cr) as changing pH of artificial wastewater and stirring time. As a result, pH 7 showed the highest heavy metal decontamination ratio and in terms of stirring time, it revealed balance adsorption after 10 minutes. This result can be particularly applied as basic data for recyclability of high concentration organic waste, by-products of food waste treatment facility, as an food waste charcoal.

The Characteristic Modes and Structures of Bluff-Body Stabilized Flames in Supersonic Coflow Air

  • Kim, Ji-Ho;Yoon, Young-Bin;Park, Chul-Woung;Hahn, Jae-Won
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.13 no.3
    • /
    • pp.386-397
    • /
    • 2012
  • The stability and structure of bluff-body stabilized hydrogen flames were investigated numerically and experimentally. The velocity of coflowing air was varied from subsonic velocity to a supersonic velocity of Mach 1.8. OH PLIF images and Schlieren images were used for analysis. Flame regimes were used to classify the characteristic flame modes according to the variation of the fuel-air velocity ratio, into jet-like flame, central-jet-dominated flame, and recirculation zone flame. Stability curves were drawn to find the blowout regimes and to show the improvement in flame stability with increasing lip thickness of the fuel tube, which acts as a bluff-body. These curves collapse to a single line when the blowout curves are normalized by the size of the bluff-body. The variation of flame length with the increase in air flow rate was also investigated. In the subsonic coflow condition, the flame length decreased significantly, but in the supersonic coflow condition, the flame length increased slowly and finally reached a near-constant value. This phenomenon is attributed to the air-entrainment of subsonic flow and the compressibility effect of supersonic flow. The closed-tip recirculation zone flames in supersonic coflow had a reacting core in the partially premixed zone, where the fuel jet lost its momentum due to the high-pressure zone and followed the recirculation zone; this behavior resulted in the long characteristic time for the fuel-air mixing.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Gasoline Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 가솔린엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.260-268
    • /
    • 2006
  • The dielectric constants of used gasoline engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$ Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz,,and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 4% for gasoline engine oil.

Study on Mutual Relation between the Level of Deterioration Influenced by the Changes of Chemical and Physical Properties and the Change of Dielectric Constant for Engine Oil - Diesel Engine Oil (엔진오일의 화학적 및 물리적 변화에 의한 퇴화정도와 유전상수 변화에 관한 상호관계 연구 - 디젤엔진오일)

  • Chun, Sang-Myung
    • Tribology and Lubricants
    • /
    • v.22 no.5
    • /
    • pp.290-300
    • /
    • 2006
  • The dielectric constants of used diesel engine oils were obtained at a few temperatures and a frequency. Through analyzing the characteristics of dielectric constant, the related correlation between the changes in dielectric constants of oil and the degree of oil deterioration is going to be found. The dielectric constant was calculated using cross capacitances measured by a sensor tube. As results of the measurement of the fresh engine oil's dielectric constant, it was found that the value of dielectric constant was set down below $60^{\circ}C$ regardless changing frequency. Further, above 6 kHz, the dielectric constant was set down even if temperature was above $100^{\circ}C$. Therefore, for the measurement of used oils, it was selected the frequency of 6 kHz, and the temperature of $80^{\circ}C$ preventing a certain ionic-conduction effects on the measured dielectric constant and the evaporation of a certain fluid mixed with engine oil. Specially, the effects of the mixing fluid like coolant, water and fuel on the fresh engine oil's dielectric constant were studied. It was found that the oil mixed with coolant showed the highest value, next water, and the lowest fuel. As results of the measurement of the used engine oil's dielectric constant, it was found that the possible changed rate of the used engine oil's dielectric constant based on the warning limit for engine oil in service was below 10% for diesel engine oil.

A CFD Study of the Supersonic Ejector-Pump Flows (초음속 이젝터 펌프 유동에 관한 수치해석)

  • 이영기;김희동;서태원
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.3 no.4
    • /
    • pp.58-66
    • /
    • 1999
  • The flow characteristics of supersonic ejectors is often subject to compressibility, unsteadiness and shock wave systems. The numerical works carried out thus far have been of one-dimensional analyses or some Computational Fluid Dynamics(CFD) which has been applied to only a very simplified configuration. For the design of effective ejector-pump systems the effects of secondary mass flow on the supersonic ejector flow should be fully understood. In the present work the supersonic ejector-pump flows with a secondary mass flow were simulated using CFD. A fully implicit finite volume scheme was applied to axisymmetric compressible Navier-Stokes equations. The standard two-equation turbulence model was employed to predict turbulent stresses. The results obtained showed that the flow characteristics of constant area mixing tube types were nearly independent of the secondary flow rate, but the flow fields of ejector system with the second-throat were strongly dependent on the secondary flow rate due to the effect of the back pressure near the primary nozzle exit.

  • PDF

Sensitivity Characteristics on the Composition Change of the Gas Sensing Materials based on $In_2O_3$ Semiconductor. ($In_2O_3$계 반도성 가스감지재료의 조성변화에 따른 감도특성)

  • 정형진;유광수
    • Journal of the Korean Ceramic Society
    • /
    • v.22 no.4
    • /
    • pp.54-60
    • /
    • 1985
  • Gas sensing materials for detecting flammable gases such as $CH_4$, $C_3H_8$ and n-$C_4H_{10}$ were developed by util-izing $In_2O_3$ as the principal sensing material. The sensing materials were formulated by mixing $In_2O_3$ powder with one or two other chemicals such as $SnO_2$, $Y_2O_3$ and $Al_2O_3$ with a small addition of $PdCl_2$ as a catalyst. Sample of sensor were fabricated by coating each of the mixtures on a ceramic tube impregnating ethylsili-cate and firing at 75$0^{\circ}C$ Each material mixture was evaluated by measuring and comparing gas sensitivity(resistance in air/resistance with gas) to flammable gases such as $CH_4$, $C_3H-8$ and n-$C_4H_{10}$. It was found that among fifteen compositions tested three compositions as follows show the highest gas sensitivity and thus are very feasible for commercialization as the gas sensors ; o49.5 $In_2O_3$+50 Al2O3_0.5 PdCl2(wt%) o $20In_2O_3+29$ $SnO_2+50$ $Al_2O_3+1$ $PdCl_2$(wt%) o40 $In_2O_3$+9 $Y_2O_3+50$ $Al_2O_3+1$ $PdCl_2$(wt%)

  • PDF