• Title/Summary/Keyword: Mixing System

Search Result 1,788, Processing Time 0.035 seconds

Numerical Simulation Study on Combustion Characteristics of Hypersonic Model SCRamjet Combustor

  • Won, Su-Hee;Eunju Jeong;Jeung, In-Seuck;Park, Jeong-Yeol
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2004.03a
    • /
    • pp.42-47
    • /
    • 2004
  • Air-fuel mixing and flame-holding are two important factors that have to be considered in the design of an injection system. Different injection strategies have been proposed with particular concern for rapid air-fuel mixing and flame-holding. Two representative injection techniques can be applied in a supersonic combustor. One of the simplest approaches is a transverse(normal) injection. The cavity flame holder, an integrated fuel injection/flame-holding approach, has been proposed as a new concept for flame holding and air-fuel mixing in a supersonic combustor. This paper describes numerical efforts to characterize the flame-holding and air-fuel mixing process of a model scramjet engine combustor, where hydrogen is injected into a supersonic cross flow and a cavity. The combustion phenomena in a model scramjet engine, which has been experimentally studied at University of Queensland and Australian National University using a free-piston shock tunnel, were observed around the separation region of the transverse injector upstream and the inside cavity. The results show that this flow separation generates recirculation regions which increase air-fuel mixing. Self-ignition occurs in the separation-freestream and cavity-fteestream interfaces.

  • PDF

Evaluation of Floc Formation Conditions for Increasing Flotation Velocity in DAF Process (DAF 공정에서 부상속도 향상을 위한 플럭형성 조건 평가)

  • Kwon, Soon-Buhm;Min, Jin-Hee;Park, No-Suk;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.20 no.2
    • /
    • pp.245-255
    • /
    • 2006
  • Dissolved air flotation is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In order to enhance the flotation velocity and removal efficiency of flocs in the flotation process, we tried to obtain pretreatment conditions for the optimum DAF process operation by comparing and evaluating features of actual floc formation and flotation velocity etc, according to coagulant types and conditions for flocculation mixing intensity by using PIA, PDA, and FSA. Accordingly, generating big flocs that have low density at low flocculation mixing intensity may reduce treatment efficiency. In addition, generating small flocs at high flocculation mixing intensity makes floc-bubbles smaller, which reduces flotation velocity, In this study, it was found that high flocculation mixing intensity could not remove the remaining micro-particles after flocculation, which had negative effects on treated water quality, Therefore, in order to enhance treatment efficiency in a flotation process, flocculation mixing intensity around $50sec^{-1}$ is effective.

Optical Decryption System of Binary Image Using Two-Wave Mixing in Photorefractive Crystal (광굴절 매질에서 2광파 혼합을 이용한 이진 영상 복호화 시스템)

  • 최상규;신창목;서동환;김철수;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06b
    • /
    • pp.83-86
    • /
    • 2002
  • We suggest binary image decryption system using two-wavc mixing in Photorefractive crystal. Compared with a conventional method, this method can make optical alignment easily, and brighten the encrypted image even if a small input signal, by index grating of photorefractive crystal. Also it can reconstruct the encrypted image by only reference beam in real time.

  • PDF

Optical Decryption System of Binary Image Using Two-Wave Mixing in Photorefractive Crystal (광굴절 매질에서 2광파 혼합을 이용한 이진 영상 복호화 시스템)

  • 최상규;신창목;서동환;김철수;김수중
    • Proceedings of the IEEK Conference
    • /
    • 2002.06a
    • /
    • pp.207-210
    • /
    • 2002
  • We suggest binary image decryption system using two-wave mixing in photorefractive crystal. Compared with a conventional method, this method can make optical alignment easily, and brighten the encrypted image even if a small input signal, by index grating of photorefractive crystal. Also it can reconstruct the encrypted image by only reference beam in real time.

  • PDF

A Study on the Mix Design and the Control System of Thermal Crack for High Quality Mass Concrete (고품질 매스콘크리트 시공을 위한 배합설계 및 온도균열제어 시스템에 관한 연구)

  • Kim, Sun-Gu;Lee, Sang-Soo;Won, Cheol;Park, Sang-Joon;Kim, Dong-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.174-178
    • /
    • 2001
  • This study was performed to control the thermal crack of the mat footing slab in the multi-purposed buildings. In this study, we executed the mixing design of concrete to satisfy the workability and the quality according to the site conditions. And, we evaluated quantitatively about the possibility of thermal crack by using hydration heat analysis system. Finally, we proposed the optimal mixing conditions, curing methods and curing period which all factors are considered. As a result, the optimal mixing conditions were : W/B 41%, unit binder 375kgf/$\textrm{m}^3$, FA replacement ratio 20%. Lowest thermal stress was 22.0kgf/$\textrm{cm}^2$ and at that time thermal crack index was over 1.5, when the coefficient of thermal conductivity was lowest among the curing conditions. And, the total curing time was estimated at 6.7 days according to curing steps.

  • PDF

Experiment of Turbulent Heat Transfer Performance Enhancement in Rod Bundle Subchannel by the Large Scale Vortex Flow (대형 2차 와류에 의한 봉다발 부수로에서의 난류 열전달 향상에 관한 실험적 연구)

  • Seo, Kwi-Hyun;Choi, Young-Don
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1592-1597
    • /
    • 2004
  • Experimental studies were carried out to confirm the turbulent enhancement of the cooling system of nuclear reactor by large scale vortex generation in nuclear fuel rod bundle. The large scale vortex motions were generated by rearranging the inclination angles of mixing vanes to the coordinate directions. Experimental studies were carried out at Reynolds Number 60,000 with hydraulic condition. Normal variations of mean velocity and turbulent intensity in the rod bundle subchannel were measured by the 2-color LDV measurement system. The turbulence generated by split mixing vanes has small length scales so that they maintain only about 10DH after the spacer grid. On the other hand, the turbulences generated by the large scale vortex continue more and remain up $25D_{H}$ after the spacer grid.

  • PDF

Dispersibility, Electrical Property of Nano-Composite by Solution Mixing Method (용액혼합법에 따른 나노복합재료 분산성 및 전기적 특성)

  • Yang, Hoon;Park, Dae-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.04c
    • /
    • pp.73-74
    • /
    • 2008
  • In this paper, we have investigated dispersibility, volume resistivity of nano-composite by solution mixing method. Dispersibility measured by FE-SEM(Field Emission Scanning Electron Microscope. And volume resistivity measured by ASTM D991. To expect interaction used dual filler system. But, dual filler system had influence on polymer complex. So, polymer chain mobility doesn't resist.

  • PDF

A Study on the One-way Optical Image Transmission Through Optical Fiber by Degenerate Four Wave Mixing (축퇴 4 광파 혼합에 의한 광섬유에서의 광영상 직접전송에 관한 연구)

  • 안병구;이우상;김은수;양인응
    • Journal of the Korean Institute of Telematics and Electronics
    • /
    • v.25 no.4
    • /
    • pp.460-466
    • /
    • 1988
  • In this paper, the theory and experiments on the one-way optical image transmission through optical fiber by using degenerate four wave mixing in BSO single crystal are demonstrated. From the theoretical analysis, the diffraction efficiency of phase conjugate wave in BSO single crystal is greatly dependent on applied electric field intensity, diffraction grating period formed in the crystal and incident beam ratio, those are also in good agreement with the experimental results. Based on the experimental results, we have arranged the typical degenerate four wave mixing system in the optimal conditions (applied electric field, E. = 5kV/cm` diffraction grating period, 3\ulcorner` beam ratio of backward pump wave versus signal wave, 2.7) and realized one-way optical image transmission system through optical fiber using BSO single crystal.

  • PDF