• 제목/요약/키워드: Mixing System

검색결과 1,788건 처리시간 0.025초

간이상수도에서 물과 약품의 혼합방법 (Mixing Method of Water and Chemicals in a Small-Scale Water Supply System)

  • 유영현;기현;최종욱;김성초;김정수;김용선
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3128-3133
    • /
    • 2007
  • The mixing method of water and chemicals is significant in a small-scale water supply system because drinking water should be supplied with a certain quantity of remaining chemicals maintained. In the present study, the concentration distribution and the mixing index were obtained from four models, which were to find out the optimal mixing method of water and chemicals. The two models brought the good mixing effects out of the four, one for providing chemicals from the center of water supply pipe and the other for setting up the semicircle block at the downstream of the chemicals-providing pipe. As a result, the mixing effect was found out to be increased due to the diffusion and the disturbance of flows. In conclusion, these results are expected to contribute to designing the optimal mixing system.

  • PDF

인라인 주입방식의 최초응집이 케이크 저항에 미치는 영향 (Effect of cake resistance by first-aggregation of in-line injection system)

  • 김태영;박희경
    • 상하수도학회지
    • /
    • 제22권3호
    • /
    • pp.281-288
    • /
    • 2008
  • Cake resistance is influenced by floc size deposited on membrane surface. Enlarging floc size can reduce cake resistance. The small particles are enlarged by coagulation and flocculation process in conventional mixing tank at membrane filtration system. Fully-grown flocs for reducing the cake resistance, however, are ruptured while passing through a pump. In light of this fact, this study aims to experimentally look at the reaggregation phenomenon of mixing system. In addition, reaggregation phenomenon of mixing system is compared with first-aggregation of in-line injection system in which coagulant is injected just before a pump. These results suggest that first-aggregation of in-line injection system is better than reaggregation of mixing system for G-value above $3100sec^{-1}$. Since G-value in pipe of actual membrane filtration system are usually larger than $3100sec^{-1}$. The performance of in-line injection system is expected to be better than the conventional mixing tank system.

CFD를 이용한 펌프확산 및 수리낙차 방식의 혼화공정 흐름 분석 (MIXING PROCESS FLOW ANALYSIS OF PDM AND HYDRAULIC MIXING BASIN SYSTEM USING CFD)

  • 이성우;장세명;조용
    • 한국전산유체공학회지
    • /
    • 제22권1호
    • /
    • pp.1-7
    • /
    • 2017
  • The mixing of water and chemicals is an important process in the water purification plant. In this paper, we compare PDM(pump diffusion mixer) and hydraulic mixer at the basin in the mixing process. The proper flow rates are predicted and compared in both mixers using CFD technique. As a result, the flow rate of purifier chemical liquid should be 5% of that of water for the optimal performance of mixing process. The characteristics of the two mixing methods are compared with each other for strong and weak points on the operation of the purification system, discussed in the view point of CFD simulations.

스태틱 믹서 개발 및 응용 (Development and Application of Static Mixer)

  • 양희천
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제31권5호
    • /
    • pp.506-513
    • /
    • 2007
  • One of the most widely used static mixers is Sulzer type mixer. However the structure of the element is so complicated that the mixing efficiency is better than others, whereas the pressure drop is larger than the others. Therefore new elements are necessary to reduce the pressure drop and to minimize the decrease of the mixing efficiency compared with the Sulzer ones. The objectives of this study are to develop new static mixer and to perform the experimental investigation in order to evaluate the performance of the new one, and to investigate the applicability of the one in an inline coagulant mixing system for water treatment, The pressure drops of the new static mixer elements were about 4-12% lower than that of the Sulzer SMX one, and the mixing efficiency of the Sulzer SMX one was about 2-5% higher than that of the new ones. The inline coagulant mixing system with a new static mixer element performed significantly better than the traditional mechanical mixing system for turbidity removal.

도시 하수의 해양방류 및 근역혼합특성 분석 (Analyses of Ocean Discharges Municipal Water and its Near-Field Mixing Characteristics)

  • 김강만;김지연;이중우
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 1999년도 추계학술대회논문집
    • /
    • pp.243-252
    • /
    • 1999
  • Recently several research groups using CORMIX, approved by EPA, have been working on the hydrodynamic mixing processes due to the ocean discharges. It provides a useful tool for analyzing near field mixing characteristics through the outfall system. This paper applies CORMIX 1 & 2 to the Pusan Jungang Effluent Outfall System, which is planned to be in the Gamchun harbour and will be completed in 2011. This model output shows the trajectoral variation of dilution and concentration for three cases of outfall system. Dilution differences have been simulated and found the highest dilution condition under the different displacement of outfall system. On the basis of these outputs it will be proposed the optimum outfall system type and location. This approach might contribute on protecting the serious water quality problem due to the ocean discharge.

하이브리드 로켓 추진 시스템의 혼합 연소실 적용에 따른 Trade-off 평가 (Trade-off Evaluation due to Application of Mixing Chamber for Hybrid Rocket-Propulsion System)

  • 김학철;문근환;문희장;김진곤
    • 항공우주시스템공학회지
    • /
    • 제10권3호
    • /
    • pp.23-31
    • /
    • 2016
  • The intermediate mixing chamber is one of various methods for improving the regression rate and combustion efficiency of the hybrid rocket. The mixing chamber with its non-combustible material makes the propulsion performance increase, but it leads to a low fuel-loading density in the combustion chamber; therefore, this performance-related trade-off between the mixing chamber and the low fuel-loading density was studied. In this study, the trade-off was conducted by comparing the intermediate-mixing-chamber case with a w/o-mixing-chamber case. The small hybrid-sounding rocket is designed with internal ballistics for comparing the rocket length to the weight. In addition, an external ballistic analysis was conducted for comparing the performances of the w/- and w/o-mixing-chamber cases. As a result, the intermediate-mixing-chamber case shows that the length and the weight were decreased to 12 % and 8 %, respectively; furthermore, when compared with the normal cases, the estimated altitude result of the w/-mixing-chamber case was increased to approximately 75 m.

Dual-plane Stereoscopic PIV Measurement on the Lobed Jet Mixing Flow

  • SAGA Tetsuo;KOBAYASHI Toshio
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2001년도 Proceedings of 2001 Korea-Japan Joint Seminar on Particle Image Velocimetry
    • /
    • pp.108-122
    • /
    • 2001
  • In a continuing effect to study the mixmg enhancement by large-scale streamwise vortices in lobed mixing flows, an advanced PIV system named as dual-plane stereoscopic PIV system was used in the present study to conduct simultaneous vorticity (all three components) measurement of an air jet exhausted from a lobed nozzle. Unlike 'classical' 2-D PIV system or conventional 'single-plane' stereoscopic PIV system, the dual-plane stereoscopic PIV system used in the present study can obtain the flow velocity (all three components) fields at two spatially separated planes simultaneously. Therefore, it can provide the distributions of all the three components of vorticity vectors instantaneously and simultaneously. The evolution and interaction characteristics of the large-scale streamwise vortices and azimuthal Kelvin-Helmholtz vortices in the lobed jet mixing flow were revealed instantaneously and quantitatively from the measurement results of the dual-plane stereoscopic PIV system. The characteristics of the mixing process in the lobed jet mixing flow were analyzed based on the simultaneous measurement results of the steamwise vorticity and azimuthal Kelvin-Helmholtz vorticity distributions.

  • PDF

초음속 유동장 내 연료 다중 분사의 혼합 특성 (Mixing Characteristics of Multiple Injection in Supersonic Flow)

  • 이종환;이상현
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2004년도 제23회 추계학술대회 논문집
    • /
    • pp.53-56
    • /
    • 2004
  • The mixing characteristics of a multiple transverse injection system in a scramjet combustor were studied with numerical methods. The distance among injectors on mixing characteristics were investigated. The three-dimensional Wavier-Stokes equations including k-w SST turbulence model were solved. It was shown that the mixing characteristics of a multiple transverse injection system were very different from those of a single and a dual injection system; the rear injection flow was strongly influenced by blocking effect due to the momentum flux of the front injection flow and thus had higher expansion and penetration than the front injection flow. The multiple injection system had higher mixing rate, higher penetration but had more losses of stagnation pressure than the single injection system.

  • PDF

인라인 응집제 혼화시스템의 혼화 및 응집특성 (Characteristics of Mixing and Coagulation in an Inline Coagulant Mixing System)

  • 양희천;박상규;왕승호
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2007년도 춘계학술대회B
    • /
    • pp.3139-3143
    • /
    • 2007
  • The objective of this paper was to investigate the mixing characteristics of an three-stage inline coagulant mixing system experimentally. Wastewater samples of pH 8.5 and initial turbidity 1,000NTU were taken from a site of tunneling work. At the constant dosage, 0.36mL/L, of polymer as coagulant aids, the coagulation efficiency with the dosage of PAC as coagulant was about 4${\sim}$6% at 10 minutes after sampling. In the case of 2 different velocity gradient conditions, the efficiency of turbidity removal was increased about 6.5${\sim}$8% with increasing the dosage of coagulant while, the efficiency was increased about 20${\sim}$21.5% with increasing the dosage of coagulant aids. The efficiency of turbidity removal with the settling time after sampling was about 90% after 1 minute, and the efficiency was about 95% after 5 minutes.

  • PDF

공기조화설비(HVAC) 설계시 혼합손실의 정량적 평가방안의 제안 (The Proposal of a Quantitative Evaluation Method on Mixing Loss in the HVAC System Design)

  • 이정재
    • 설비공학논문집
    • /
    • 제12권10호
    • /
    • pp.879-885
    • /
    • 2000
  • It is a serious subject for energy conservation to prevent the energy loss caused by mixing of heated and cooled air jets in a building which two types of air-conditioning systems are adopted in perimeter and interior zone. The purpose of this paper is to clarify the quantitative and qualitative mechanisms of the mixing loss and to propose preventive methods for it. In this paper, by using the dynamic heat load calculation method, heat extraction loads of a typical office building in Pusan are calculated. According to the results, numerical simulation based on the computational fluid dynamics were peformed in order to measure the mixing loss in physical size HVAC system. Then, the distributions of air temperature and velocity are analyzed in order to grasp the relations by setting temperature differences influence on the mixing loss.

  • PDF