• Title/Summary/Keyword: Mixed load

Search Result 465, Processing Time 0.03 seconds

Field Testing Methods on Early Shotcrete Strength for Tunnel Quality Control (터널의 품질관리를 위한 숏크리트 초기강도의 현장강도 시험기술)

  • Hong, Eui-Joon;Chang, Seok-Bue;Lee, Sung-Woo;Kim, Ki-Lim;Moon, Sang-Jo
    • Proceedings of the KSR Conference
    • /
    • 2007.05a
    • /
    • pp.468-476
    • /
    • 2007
  • Generally, the strength of the field shotcrete is heavily dependent on the field mixing and spraying conditions so that it is different from the strength of the shotcrete mixed in laboratories. As a support member, the early strength of shotcrete unlike concrete as structural material is very important to the initial stabilization of the excavation face in tunnels. Therefore, the field methods to efficiently test the early strength of shotcrete have been highly required. This paper aimed to verify the pneumatic pin penetration test and the point load test for measuring the early strength of the field shotcrete. Through a series of uniaxial compression, pin penetration, and point load tests for the range of the early shotcrete strength, two equations to estimate reliably the uniaxial compressive strength by the pin penetration and the point load tests were derived. Field tests in working tunnel were carried out in order to estimate the economic efficiency. As a result, pin penetration method was proved to be the most effective method for testing the early strength of the field shotcrete.

  • PDF

Development of Removable Soil Nail (제거식 쏘일 네일 개발 및 성능 평가)

  • Kim, Nak-Kyung;Kim, Sung-Kyu;Kim, Ung-Jin;Kim, Woong-Kyu;Cho, Kyu-Wan;Sin, Sang-Hoon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.896-901
    • /
    • 2009
  • A Soil Nail is a structural element which provides load-transfer to the ground in excavation reinforcement applications. The nail may simply consist of a steel tendon, but most commonly the tendon is encapsulated in a cement grouted body to provide corrosion protection and improved load- transfer to the ground. For temporary excavation support in a congested urban area, the steel bar of Soil Nails should be removed to get permission of the private land to install Soil Nails. Several removable nail systems were developed and evaluated by pull-out load tests. The Soil Nail pull-out tests were performed on five nails installed in soft and hard rock at a 00 housing-redevelopment area in seoul. Two nails are plastic socket type and two are complex socket type mixed steel and plastic. The nail was 0.1mm in diameter, 4m long. In this study verification tests, and steel bar removing tests of plastic socket type nails and complex socket type nails were performed and presented.

  • PDF

A Study on the Tribological Characteristics of PTFE Composites-filled with Nano CuO Particles Under a Slow Sliding Speed and Low Load Condition (나노 CuO입자로 충진된 PTFE 나노복합소재의 저속 및 하중 조건에서의 트라이볼로지 특성에 관한 연구)

  • Minhaeng Cho;Junghwan Kim
    • Tribology and Lubricants
    • /
    • v.39 no.3
    • /
    • pp.111-117
    • /
    • 2023
  • This paper presents an experimental investigation of the tribological characteristics of PTFE composites filled with nano CuO particles under low sliding speed and load. All the specimens were prepared by sintering. Before sintering, the mixture of PTFE powder and CuO particles were mixed by a high-speed mixer using CuO volume fractions of 0.2 vol. % and 5 vol. %. Each mixture was sintered at 350 ℃ for 30 min on the steel disk. We conducted ball-on-disk sliding test an hour using a steel ball against PTFE composites, including pure PTFE. The load and sliding speed used was 2 N and 0.01 m/s, respectively. Adding nano CuO particles increases the friction coefficient because of the abrasiveness of hard nano CuO particles. The highest coefficient of frictions was obtained from 5 vol. % CuO. Conversely, the lowest wear of the composites was obtained from the 5 vol. % CuO nanocomposite. This study reveals that the addition of nano CuO particles can lower the wear of PTFE, despite an increase in the coefficient of friction. However, the coefficient friction is still moderate compared to other engineering polymers. In addition, the amount of CuO nano particles has to be optimized to reduce friction and wear at the same time.

The Effect of the Types of Learning Material and Epistemological Beliefs in an Ill-structured Problem Solving

  • OH, Suna;KIM, Yeonsoon;KANG, Sungkwan
    • Educational Technology International
    • /
    • v.16 no.2
    • /
    • pp.183-200
    • /
    • 2015
  • This study investigated the effect of learning achievements and cognitive load according to different types of presenting learning materials and epistemological beliefs (EB). Learning achievements in this study were composed by retention and transfer of ill-structured problem. A total of 80 college students participated in the study. Prior to the learning, students were guided to fill out a questionnaire regarding epistemological beliefs and a prior knowledge test. The students of each group studied with a different type of reading material: full text (FT), full text including key questions (KeyFT) and full text including a concept map (CmFT). After a session of study was finished, they were asked to complete the posttest: retention and transfer. The results showed that there was a significant difference in transfer achievements. CmFT outperformed higher scores than the other types. There was no significant difference in retention among the groups. It is strongly believed that the types of presenting learning materials may have affected the understanding of ill-structured problem solving skills. Students with sophisticated EB showed higher achievements on retention and transfer than naive-EB and mixed-EB. Even though the data showed decrease of the cognitive load on the type of materials and EB, there were no significant differences on the cognitive load. We should consider a positive effect of types of presenting learning materials and EB enhancing capabilities of solving ill-structured problems in real life.

Flexural Experiment of PSC-Steel Mixed Girders and Evaluation for Analyses on Tangentional Stiffness of Connection (프리스트레스트 콘크리트-강 혼합거더의 휨 실험 및 경계면 수평계수 분석)

  • Kim, Kwang-Soo;Jung, Kwang-Hoe;Sim, Chung-Wook;Yoo, Sung-Won
    • Journal of the Korea Concrete Institute
    • /
    • v.20 no.2
    • /
    • pp.231-237
    • /
    • 2008
  • This study was performed to evaluate joint behavior of prestressed concrete(PSC)-steel mixed girders through the flexural test of 14 beams according to embedded length, amount of reinforcing steel, stud arrangement, and prestressing force. All test beams were failed by turns of desertion of reinforcing steel, stud, and steel plate. From test results, prestressing force was more effective on performance of connection than stud arrangement and reinforcing steel. And the spacing of stud is also more effective than embedding length. This paper also presented 3D nonlinear analysis considering the slip of composite section as well as the static load tests of PSC-steel mixed girders. According to the slip modulus, the nonlinear analysis showed that the behavior of hybrid girders could be divided into three parts as full-composite, partial-composite and non-composite. However, the experimental results showed that the PSC-steel hybrid girders with shear connectors took the part of partial composite action in ultimate load stage. In addition, it was founded that stud shear connectors and welded reinforcements were contributed to improve the ultimate strength of hybrid girders for about 20%.

The Performance Analysis of a Return Air Bypass Air Conditioning System by a Simulator Experiment (실물실험에 의한 순환공기 바이패스 공조시스템의 성능분석)

  • 신현준;김보철;김정엽
    • Journal of Energy Engineering
    • /
    • v.11 no.2
    • /
    • pp.130-135
    • /
    • 2002
  • Bypass air conditioning systems are divided into three types; outdoor air bypass, mixed air bypass and return air bypass system. Among bypass air conditioning systems, a return air bypass system is more effective than other two systems because it doesn't induce unconditioned outdoor air into conditioned room. The numerical study on the bypass air conditioning system shows this system can maintain indoor RH(Relative Humidity) less than a conventional CAV (Constant Air Volume) air conditioning system by adjusting face and bypass dampers at part load. A simulator was built to compare results of a numerical experiment and those of a simulator experiment. The results of the simulator experiment was nearly same as those of the numerical experiment; when a design sensible load (the ratio of sensible load to total sensible load) was 70 percent (at this time, RSHF=0.7), indoor relative humidity (in case of both numerical experiments and simulator experiments) was maintained below 60% specified by ASHRAE STANDARD 62-1999. The bypass air conditioning system is expected to be applied to many buildings where the Percentage of latent loads or air change tate is high.

Determination of Veterinary Antibiotic Residues: IV. Comparable Analytical Methods with EPA Methods 1694_A Review (시료 중 잔류 항생제 분석 방법: IV. EPA method 1694와 비교 가능한 기기 분석 방법)

  • Kim, Chansik;Ryu, Hong-Duck;Chung, Eu Gene;Kim, Yongseok;Rhew, Doug Hee
    • Journal of Korean Society on Water Environment
    • /
    • v.32 no.6
    • /
    • pp.670-699
    • /
    • 2016
  • In this study, 16 antibiotics were selected from among the top 30 veterinary antibiotics sold in South Korea in 2014, as well as from among the pharmaceuticals targeted by EPA method 1694, in order to review analytical methods for the detection of trace levels of antibiotics in environmental samples: surface water, soils, animal origin foods, and manures. LC-MS/MS was heavily used. In the chromatography for the detection of the selected antibiotics, the $C_{18}$ column was mostly used at the temperature of $30{\sim}40^{\circ}C$. Water and methanol/acetonitrile were commonly chosen as a nonpolar and a polar mobile phase, respectively. Gradient elution was applied to separate multiclass antibiotics. Volatile additives, such as formic acid, acetic acid, and ammonium acetate were mixed with the mobile phase to improve the ionization efficiency of analytes and the sensitivity in MS detection. Electrospray ionization (ESI) was widely used in the LC-MS/MS and positive ionization was preferred to determine the selected antibiotics. A protonated $[M+H]^+$ molecule was selected as a precursor ion, and its two transitions were analyzed, one for quantitative measurement and the other for confirmation. This study reviewed linearity of the calibration curve, recovery, repeatability, method detection limits (MDLs), and method quantification limits (MQLs) for each target compound used to validate the developed analytical methods.

Phosphorus Budget of a River Reservoir, Paldang (하천형 호수인 팔당호의 인 수지)

  • Kong, Dongsoo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.3
    • /
    • pp.270-284
    • /
    • 2018
  • Paldang is a river reservoir located in the Midwest of Korea, with a water volume of $244{\cdot}10^6m^3$ and a water surface area of $36.5km^2$. It has eutrophied since the construction of a dam at the end of 1973, and the phosphorus concentration has decreased since 2001. Average hydraulic residence time of the Paldang reservoir is about 10 days during the spring season and 5.6 days as an annual level. The hydraulics and water quality of the reservoir can differ greatly, both temporally and spatially. For the spring period (March to May) in 2001 ~ 2017, the reservoir mean total phosphorus concentration calculated from the budget model based on a plug-flow system (PF) and a continuous stirred-tank reaction system (CSTR) was 13 % higher and 10 % lower than the observed concentration, respectively. A composite flow system (CF) was devised by assuming that the transition zone was plug flow, and that the lacustrine zone was completely mixed. The mean concentration calculated from the model based on CF was not skewed from the observed concentration, and showed just 6 % error. The retention coefficient of the phosphorus derived from the CF was 0.30, which was less than those of the natural lakes abroad or river reservoirs in Korea. The apparent settling velocity of total phosphorus was estimated to be $93m\;yr^{-1}$, which was 6 ~ 9 times higher than those of foreign natural lakes. Assuming CF, the critical load line for the total phosphorus concentration showed a hyperbolic relation to the hydraulic load in the Paldang reservoir. This is different from the previously known straight critical load line. The trophic state of the Paldang reservoir has recently been estimated to be mesotrophic based on the critical-load curve of the phosphorus budget model developed in this study. Although there is no theoretical error in the newly developed budget model, it is necessary to verify the validity of the portion below the inflection point of the critical-load curve afterwards.

Study on Wear of Journal Bearings during Start-up and Coast-down Cycles of a Motoring Engine - II. Analysis Results (모터링 엔진의 시동 사이클 및 시동 정지 사이클에서 저어널베어링의 마모 연구 - II. 해석 결과)

  • Chun, Sang Myung
    • Tribology and Lubricants
    • /
    • v.31 no.3
    • /
    • pp.125-140
    • /
    • 2015
  • In this paper, we present the results of the wear analysis of journal bearings on a stripped-down single-cylinder engine during start-up and coast-down by motoring. We calculate journal bearing wear by using a modified specific wear rate considering the fractional film defect coefficient and load-sharing ratio for the asperity portion of a mixed elastohydrodynamic lubrication (EHL) regime coupled with previously presented graphical data of experimental lifetime linear wear in radial journal bearings. Based on the calculated wear depth, we obtain a new oil film thickness for every crank angle. By examination of the oil film thickness, we determine whether the oil film thickness at the wear scar region is in a mixed lubrication regime by comparing dimensionless oil film thickness, h/σ, to 3.0 at every crank angle. We present the lift-off speed and the crank angles involved with the wear calculation for bearings #1 and #2. The dimensionless oil film thickness, h/σ, illustrates whether the lubrication region between the two surfaces is still within the bounds of the mixed lubrication regime after scarring of the surface by wear. In addition, we present in tables the asperity contact pressure, the real minimum film thickness at the wear scar region, the modified specific wear rate, and the wear angle, α, for bearings #1 & #2. To show the real shape of the oil film at wear scar region, we depict the actual oil film thickness in graphs. We also tabulated the ranges of bearing angles related with wear scar. We present the wear volume for bearings #1 and #2 after one turn-on and turn-off of the engine ignition switch for five kinds of equivalent surface roughness. We show that the accumulated wear volume after a single turn-on and turn-off of an ignition switch normally increases with increasing surface roughness, with a few exceptions.

On Designing 4-way Superscalar Digital Signal Processor Core (4-way 수퍼 스칼라 디지털 시그널 프로세서 코어 설계)

  • 김준석;유선국;박성욱;정남훈;고우석;이근섭;윤대희
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.6
    • /
    • pp.1409-1418
    • /
    • 1998
  • The recent audio CODEC(Coding/Decoding) algorithms are complex of several coding techniques, and can be divided into DSP tasks, controller tasks and mixed tasks. The traditional DSP processor has been designed for fast processing of DSP tasks only, but not for controller and mixed tasks. This paper presents a new architecture that achieves high throughput on both controller and mixed tasks of such algorithms while maintaining high performance for DSP tasks. The proposed processor, YSP-3, operates four algorithms while maintaining high performance for DSP tasks. The proposed processor, YSP-3, operates functional units (Multiplier, two ALUs, Load/Store Unit) in parallel via 4-issue super-scalar instruction structure. The performance evaluation of YSP-3 has been done through the implementation of the several DSP algorithms and the part of the AC-3 decoding algorithms.

  • PDF