• 제목/요약/키워드: Mixed fluid

검색결과 436건 처리시간 0.029초

Determination of Saturated and Unsaturated Fatty Acids Amount in Leukocyte Membranes from Subjects Fed with Solid and Fluid Oils

  • Erman, Fazilet;Aydin, Suleyman;Demir, Yasar;Akcay, Fatih;Bakan, Ebubekir
    • BMB Reports
    • /
    • 제39권5호
    • /
    • pp.516-521
    • /
    • 2006
  • Modifications in dietary fatty acid intake might lead to a modification in membrane phospholipid fatty acid composition. The purpose of this study was to investigate relationship between different type of oil consumption and leukocyte membrane phospholipid composition. This study was carried out in subjects utilizing butter (n = 15), margarine (n = 15), fluid oil (n = 15) and mixed types of oils (n = 15) in total 60 subjects. Leukocytes were separated from total blood by dextran sedimentation method. Membrane lipids and proteins were isolated following the cell disruption. Fatty acids of membrane phospholipids were isolated by hydrolysation with phospholipase B under ultrasonic dismembranator. Free fatty acids were identified with gas chromatography at chloroform phase. The results obtained were compared with data obtained by chromatograms of the standards. Results more prominent values of arachidic, dihomo-$\gamma$-linolenic and palmitoleic acids were found in butter-or mixed oil-user groups; eicosadienoic, eicosamonoenoic, dihomo-$\gamma$-linolenic and behenic acids in fluid oil; heptanoic, valeric, eicosadienoic and linolenic acids in margarine groups. The fatty acid composition of mixed oil was similar to butter, while other two oils were so different. From this study, it was concluded that the type of oil consumption might have an influence on phospholipid components of plasma membranes.

도시철도 소음저감을 위한 MFI(Multi Fluid Injection) 시스템 개발 및 효과에 관한 연구 (A Study on the Development of MFI(Multi Fluid Injection) System and its Effect to Reduce the Noise of Subway)

  • 박종화;김대석;김희오;심재규
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.446-454
    • /
    • 2011
  • The noise of the subway has become a social issue and includes very complex reasons. The friction between rail and train wheel is the most important reason of the noise. In this study, we developed MFI(Multi Fluid Injection) System which sprays the mixed fluid(water, anticorrosive and lubricant) on the rail when the train is approaching to reduce the friction. To verify the system's effect, we measured the internal and external noise of the running train. The measured and analyzed results show that MFI system reduce the noise of the running subway.

  • PDF

ER-Valve 간극내에서 분산계 ER유체의 유동특성 (Flow Characteristics of Dispersive ER Fluid Clearance between ER-Valve)

  • 장성철;염만오;이종두;장성수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1123-1126
    • /
    • 2003
  • In this research 4 plate type ER-Valves which have same surface but different width and length are designed and an experimental apparatus is constructed. With this experimental apparatus, flow rate and pressure drop of ER fluid flowing in ER-Valve are measured by varying electric field strength of ER-valve, and relation between valve types and pressure drop is also experimented. ER fluid is made silicon oil mixed with 40wt% starch having hydrous particles. The pressure drop according to the strength of electric field by differential pressure gauge in the present ER-Valve was used. This test reviewed experiment for the special changes of ER fluids in the steady flow condition.

  • PDF

입자가 포함된 유체의 유동특성에 대한 직접수치해석 (Direct Numerical Simulation of Flow Characteristics of the Fluid Laden with Many Particles)

  • 조상호;최형권;유정열
    • 대한기계학회논문집B
    • /
    • 제27권9호
    • /
    • pp.1327-1334
    • /
    • 2003
  • Flow characteristics of the fluid laden with many particles in the two-dimensional channel are investigated using the Navier-Stokes equations coupled with the equation of motion of particles by direct numerical simulation. A four-step fractional step method with Crank-Nicolson scheme and ALE technique is used for P2P1 mixed finite element method. The motion and distribution of particles in the fluid is virtually described as a result of direct numerical simulation and the increase of viscosity is compared with theoretical equations. The effect of channel height on the relative viscosity and the tubular pinch effect are discussed.

원심/사류압축기의 공력설계 프로그램 개발 - 제2부 : 임펠러의 3차원 형상설계 - (Aerodynamic Design Program for Centrifugal/Mixed-flow Compressors - Part II : Three Dimensional Profile Design of Impellers -)

  • 오종식
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2003년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.464-468
    • /
    • 2003
  • A general program of three dimensional profile design of impellers for centrifugal/fixed-flow compressors is successfully commercialized using Bezier curves and quasi-3D flow analysis methods. Control points for meridional hub and shroud contours and blade camberline angles are arbitrarily changed to give smooth Bezier curves. With specified blade normal thicknesses, contructed geometry is instantly analyzed using flow analysis methods to be checked.

  • PDF

OPERATIONAL CALCULUS ASSOCIATED WITH CERTAIN FAMILIES OF GENERATING FUNCTIONS

  • KHAN, REHANA;KHAN, SUBUHI
    • 대한수학회논문집
    • /
    • 제30권4호
    • /
    • pp.429-438
    • /
    • 2015
  • In this paper, we discuss how the operational calculus can be exploited to the theory of mixed generating functions. We use operational methods associated with multi-variable Hermite polynomials, Laguerre polynomials and Bessels functions to drive identities useful in electromagnetism, fluid mechanics etc. Certain special cases giving bilateral generating relations related to these special functions are also discussed.

ON MIXED PRESSURE-VELOCITY REGULARITY CRITERIA FOR THE 3D MICROPOLAR EQUATIONS IN LORENTZ SPACES

  • Kim, Jae-Myoung;Kim, Jaewoo
    • 충청수학회지
    • /
    • 제34권1호
    • /
    • pp.85-92
    • /
    • 2021
  • In present paper, inspired by the recently paper [1], we give the mixed pressure-velocity regular criteria in view of Lorentz spaces for weak solutions to 3D micropolar equations in a half space. Precisely, if (0.1) ${\frac{P}{(e^{-{\mid}x{\mid}^2}+{\mid}u{\mid})^{\theta}}{\in}L^p(0,T;L^{q,{\infty}}({\mathbb{R}}^3_+))$, p, q < ∞, and (0.2) ${\frac{2}{p}}+{\frac{3}{q}}=2-{\theta}$, 0 ≤ θ ≤ 1, then (u, w) is regular on (0, T].

중합효소 연쇄반응에 의한 수포액, 혈액과 관절액에서 단순포진 바이러스 1, 2와 대상포진 바이러스의 검출과 감별 (Detection and Differentiation of Herpes Simplex Virus 1 and 2, and Varicella-Zoster Virus in Vesicle Fluid, Joint Fluid and Serum using PCR Method)

  • 박혜경;우소연;김현진;이정화
    • 대한미생물학회지
    • /
    • 제35권2호
    • /
    • pp.191-201
    • /
    • 2000
  • The viruses of Herpes Simplex Virus 1 (HSV-1), Herpes Simplex Virus 2 (HSV-2) and Varicella-Zoster virus (VZV) which belong to the alpha herpes subfamily are important human pathogens. When eruptions were not fully developed from these viral infections, clinical diagnosis was not always easy and required virological confirmation test. The above viruses were reactivated in individuals who were compromised in immune competence for one reason or another. Polymerase chain reaction (PCR) enables rapid and sensitive detection of HSV and VZV DNAs. Its sensitivity was largely influenced by choice of primers. Authors conducted a study to detect of those three viruses in human specimens including vesicle fluid and joint fluid and serum using PCR methods. Primers used for this study were the general primer pair GPHV-RU which was known to amplify within the genes enjoying the highest degree of homology between UL15 of HSV and UL42 of VZV. PCR with primers hybridized pair GPHV-RU amplifies a 396 bp with THP-1 and HSV-2 standard strain DNA and 405 bp with VZV standard strain DNA. Restriction enzyme cleavage with HpaII and DdeI were used to detect and distinguish DNAs of THP-1 and HSV-2 and VZV. The purpose of this study was a rapid and easy detection of VZV and THP-1 or HSV-2 from various clinical specimens (vesicle fluid, serum and joint fluid) by PCR method. Used methods were: HSV PCR with primer 1, 2 and HpaII RE digestion; VZV nested PCR; HSV PCR with primer A, Band BssHII RE digestion. 1) In 33 cases (33/42, 78.6%) VZV was detected single or mixed infection from 42 clinical specimens which included vesicle fluid (5), serum form respiratory infected children (10), serum from immune suppressed adult cancer patients (7) and joint fluid from arthritis patients (20). 2) In 20 cases (20/42, 47.6%) HSV was detected singly or mixed infection and 19 of those cases were HSV-2 and 1 case was THP-1. 3) In 19 cases (19/42, 45.2%) VZV was singly detected which included serum from respiratory infected children (6 cases), joint fluid from arthritis patients (9 cases), vesicle fluid (2 cases) and serum form immunosuppressed cancer patients (2 cases). 4) HSV was singly detected in 6 cases (6/42, 14.3%) which included joint fluid from arthritis patients (5 cases) and serum form respiratory infected children (1 cases). 5) 14 cases of VZV and HSV mixed infection (14/42, 33.3%) were detected. They included vesicle fluid (3 cases), serum form immunosuppressed cancer patients (4 cases), serum from respiratory infected children (2 cases) and joint fluid from arthritis patients (5 cases). 6) HSV-1 and HSV-2 detection and typing by HSV PCR with primer A, Band BssHII RE digestion method was more sensitive and the results were easier to detect than on other method.

  • PDF

미립잠열슬러리의 유체역학적 특성연구 (Fluid dynamical characteristics of microencapsulated phase change material slurries)

  • 이효진;이승우;이재구
    • 설비공학논문집
    • /
    • 제11권4호
    • /
    • pp.549-559
    • /
    • 1999
  • An experimental study was peformed to measure the viscosity of microencapsulated PCM slurries as the functions of its concentration and temperature, and also influence to its fluid dynamics. For the viscosity measurement, a rotary type viscometer, which was equipped with temperature control system, was adopted. The slurry was mixed with water and Sodium Lauryl Sulphate as a surfactant by which its suspended particles were dispersed well without the segregation of particles during the experiment. The viscosity was increased as the concentration of MicroPCM particle added. The surfactant increased 5% of the viscosity over the working fluid without particles. Experiments were proceeded by changing parameters such as PCM particles'concentration as well as the temperature of working fluid. As a result, a model to the functions of temperature for the working fluid and its particle concentration is proposed. The proposed model, for which its standard deviation shows 0.8068, is agreed well with the reference's data. The pressure drop was measured by U-tube manometer, and then the friction factor was obtained. It was noted that the pressure drop was not influenced by the state of PCM phase, that is solid or liquid in its core materials at their same concentration. On the other hand, it was described that the pressure drop of the slurry was much increased over the working fluid without particles. A friction factor was placed on a straight line in all working fluids of the laminar flow regardless of existing particles as we expected.

  • PDF

Preisach 모델을 이용한 ER 유체의 온도별 히스테리시스 특성 고찰 (Temperature-Dependent Hysteresis Investigation of Electro - Rheological Fluid Using Preisach Model)

  • 한영민;이호근;최승복;최형진
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2002년도 춘계학술대회논문집
    • /
    • pp.316-322
    • /
    • 2002
  • This paper presents the temperature-dependent hysteresis identification of an electro-rheological (ER) fluid under various operating temperatures using the Preisach model. As a first step, polymethylaniline (PMA) particles are prepared and mixed with silicone oil to make an ER fluid. A couette type electroviscometer is then employed to obtain the field-dependent shear stress. In order to show the suitability of the Preisach model to predict a physical hysteresis phenomenon of the ER fluid, two significant properties; the minor loop property and the wiping-out property are experimentally examined under three dominant temperature conditions. Subsequently, the Preisach model fur the PMA-based ER fluid is identified using experimental first order descending (FOD) curves. The effectiveness of the identified hysteresis model is verified in the time domain by comparing the predicted field-dependent shear stress with the measured one under the both specified and unspecified temperatures. In addition, the hysteresis model proposed in this work is compared to Bingham model.

  • PDF