원자로 냉각재 펌프의 완전 특성 곡선 (Complete Characteristic Curve for a Reactor Coolant Pump)

  • 유일수;박무룡;황순찬;윤의수
    • 한국유체기계학회 논문집
    • /
    • 제15권5호
    • /
    • pp.5-10
    • /
    • 2012
  • An experimental test facility for the complete characteristics of pumps is constructed at KIMM(Korea Institute of Machinery and Materials). All sensors instrumented in test facility for measuring flow rate, pressure, force and moment are in-situ calibrated by primary method. This paper describes the test facility and test technique of the complete characteristics of pumps, together with an experimental test results for a reactor coolant pump which is designed at KIMM for the first time in Korea. The test results for the mixed-flow type pump of $n_s$=1.425 are presented by three curves: constant head, torque, and speed.

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-251
    • /
    • 1999
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seem that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stresses.

  • PDF

Cavitation in a Shaft-less Double Suction Centrifugal Miniature Pump

  • Zhuang, Baotang;Luo, Xianwu;Zhu, Lei;Wang, Xin;Xu, Hongyuan
    • International Journal of Fluid Machinery and Systems
    • /
    • 제4권1호
    • /
    • pp.191-198
    • /
    • 2011
  • Based on the consideration that the cavitation would affect the operation stability of miniature pumps, the 3-D turbulent cavitating flow in a test pump was simulated by using a mixed cavitation model and k-${\omega}$ SST turbulence model. In order to investigate the influence of inlet geometry parameters on the cavitation performance of the miniature pump, two more impellers are designed for comparison. Based on the results, the following conclusions are drawn: 1) Cavitation performance of the double suction shaft-less miniature pump having different impeller is equivalent to the centrifugal pump having ordinary size, though the flow passage at impeller inlet is small; 2) The miniature pump having radial impeller can produce much higher pump head, but lower cavitation performance than that having the impeller based on the conventional design method; 3) It is believed that by applying the double suction design, the miniature pump achieved relatively uniform flow pattern upstream the impeller inlet, which is favorable for improving cavitation performance.

혼합 유기용제 포집시 습도가 활성탄관의 파과에 미치는 영향 (Effect of Relative Humidity on the Breakthrough of Charcoal Tubes during Mixed Organic Vapor Sampling)

  • 양혁승;김현욱
    • 한국산업보건학회지
    • /
    • 제6권1호
    • /
    • pp.125-137
    • /
    • 1996
  • This study was designed to investigate effects of relative humidity on the breakthrough of charcoal tubes at a fixed vapor concentration and sampling time during mixed organic vapor sampling. A vapor generator was used to generate three different concentrations of mixed organic vapor and a stainless steel chamber was fabricated and utilized to maintain three different percentages of relative humidity while maintaining a constant temperature. The results were as follows; 1. At high relative humidity, breakthrough of mixed organic vapor occurred quickly at low vapor concentration than at high vapor concentration because of the reduced adsorption volume of charcoal tube due to humidity. 2. Breakthrough by competitive adsorption of vapors onto charcoal tube was observed at first from n-hexane having the lowest boiling point and highest vapor pressure among the three organic vapors investigated, followed by TCE. No breakthrough was observed from toluene under all experimental conditions. 3. For n-hexane, breakthrough was observed after 2 hours of sampling and breakthrough rates were increased as relative humidity increased. For TCE, breakthrough was found after 3 hours of sampling and breakthrough rates by sampling time were increased as vapor concentration increased. 4. The adsorbed amount of mixed organic vapor at breakthrough was shown to have statistically significant correlations with sampling time, relative humidity, and vapor concentration in descending order of correlation. Relative humidity and sampling time for n-hexane and sampling time and concentration for TCE were both statistically significantly correlated. 5. Relative humidity was found to affect the amount of breakthrough of mixed organic vapor and n-hexane. Among three percentages of relative humidity investigated, the amount of breakthrough at 85 % relative humidity was significantly larger than those of at lower percentages of relative humidity. No statistically significant difference was found between 25 % and 55 % relative humidity. 6. The results of multiple regression analysis between breakthrough and relative humidity, vapor concentrations showed that the coefficient of determination of mixed organic vapor was 0.263 and those of n-hexane and TCE were 0.275 and 0.189, respectively. 7. Flow rates of sampling pumps used were found to be affected by relative humidity present. At 25 %, 55 %, and 85 % relative humidity, the relative errors of sampling pump were 1.4 %, 13.4 %, and 18.6 %, respectively. In conclusion, the results of this study showed that high relative humidity could reduce the adsorption volume of charcoal tubes and subsequently increase breakthrough rates. Therefore, to prevent breakthrough when sampling mixed organic vapors, it is suggested that either sampling volume be reduced on the flow rate be lowered so as to minimize breakthrough of the most volatile organic vapor in the mixture. In addition, since the flow rates of a sampling pump can be adversely affected by high relative humidity, it is recommended to use a constant flow mode pump when sampling in the highly humid environment.

  • PDF

Computational Fluid Dynamics of Cavitating Flow in Mixed Flow Pump with Closed Type Impeller

  • Kobayashi, Katsutoshi;Chiba, Yoshimasa
    • International Journal of Fluid Machinery and Systems
    • /
    • 제3권2호
    • /
    • pp.113-121
    • /
    • 2010
  • LES(Large Eddy Simulation) with a cavitation model was performed to calculate an unsteady flow for a mixed flow pump with a closed type impeller. First, the comparison between the numerical and experimental results was done to evaluate a computational accuracy. Second, the torque acting on the blade was calculated by simulation to investigate how the cavitation caused the fluctuation of torque. The absolute pressure around the leading edge on the suction side of blade surface had positive impulsive peaks in both the numerical and experimental results. The simulation showed that those peaks were caused by the cavitaion which contracted and vanished around the leading edge. The absolute pressure was predicted by simulation with -10% error. The absolute pressure around the trailing edge on the suction side of blade surface had no impulsive peaks in both the numerical and experimental results, because the absolute pressure was 100 times higher than the saturated vapor pressure. The simulation results showed that the cavitation was generated around the throat, then contracted and finally vanished. The simulated pump had five throats and cavitation behaviors such as contraction and vanishing around five throats were different from each other. For instance, the cavitations around those five throats were not vanished at the same time. When the cavitation was contracted and finally vanished, the absolute pressure on the blade surface was increased. When the cavitation was contracted around the throat located on the pressure side of blade surface, the pressure became high on the pressure side of blade surface. It caused the 1.4 times higher impulsive peak in the torque than the averaged value. On the other hand, when the cavitation was contracted around the throat located on the suction side of blade surface, the pressure became high on the suction side of blade surface. It caused the 0.4 times lower impulsive peak in the torque than the averaged value. The cavitation around the throat caused the large fluctuation in torque acting on the blade.

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

Study on bidirectional fluid-solid coupling characteristics of reactor coolant pump under steady-state condition

  • Wang, Xiuli;Lu, Yonggang;Zhu, Rongsheng;Fu, Qiang;Yu, Haoqian;Chen, Yiming
    • Nuclear Engineering and Technology
    • /
    • 제51권7호
    • /
    • pp.1842-1852
    • /
    • 2019
  • The AP1000 reactor coolant pump is a vertical shielded-mixed flow pump, is the most important coolant power supply and energy exchange equipment in nuclear reactor primary circuit system, whose steadystate and transient performance affect the safety of the whole nuclear island. Moreover, safety demonstration of reactor coolant pump is the most important step to judge whether it can be practiced, among which software simulation is the first step of theoretical verification. This paper mainly introduces the fluid-solid coupling simulation method applied to reactor coolant pump, studying the feasibility of simulation results based on workbench fluid-solid coupling technology. The study found that: for the unsteady calculations of the pure liquid media, the average head of the reactor coolant pump with bidirectional fluid-solid coupling decreases to a certain extent. And the coupling result is closer to the real experimental value. The large stress and deformation of rotor under different flow conditions are mainly distributed on impeller and idler, and the stress concentration mainly occurs at the junction of front cover plate and blade outlet. Among the factors that affect the dynamic stress change of rotor, the pressure load takes a dominant position.

CFX 와 HEEDS 를 이용한 사류펌프 임펠러-디퓨저 최적화방법 (Mixed-Flow Pump Impeller-Diffuser Optimization Method by Using CFX and HEEDS)

  • 이용갑;박인형;신재혁;김성;이경용;최영석
    • 대한기계학회논문집B
    • /
    • 제39권10호
    • /
    • pp.831-842
    • /
    • 2015
  • 본 논문에서는 사류펌프의 성능을 향상시키는 최적화 방법을 개발하였다. 본 연구에서 개발한 최적화 방법은 유동해석코드인 CFX 와 최적화 소프트웨어인 HEEDS 를 연계하는 프로세스로 이루어진다. CFX 는 유체기계해석 분야에서는 잘 알려진 소프트웨어로 해석결과의 신뢰성은 이미 검증되었으나, 새롭게 소개되고 있는 HEEDS 는 주로 구조해석 분야에서 최적화를 수행한 사례가 보고되어 있다. 이에 본 논문을 통해 유체기계에 적용하여 최적화 결과를 검토하였다. HEEDS 에는 SHERPA 라는 최적화 기법이 탑재되어 있으며, 다수의 설계변수를 설정할 수 있어 변수간의 교호작용 등을 효율적으로 검토할 수 있다. 본 논문에서는 DOE 방법으로 최적화가 이루어진 사류펌프 임펠러에 대해 개발된 방법을 적용하여 최적화 결과의 타당성과 안정성을 검토하였으며, 같은 방법을 디퓨저에 적용하여 최적화 형상을 검토하였다. 본 논문에서 개발된 최적화 방법을 이용하여 사류펌프 최적화를 수행한 결과, DOE 방법을 이용한 설계보다 개선된 결과를 적절한 시간 내에 얻을 수 있음을 확인하였다.

설치공간이 제한된 순환펌프의 개발에 관한 연구 (A Study on Development of a Circulating Pump with Space Constraintst)

  • 윤의수;유일수;황순찬;오형우
    • 한국유체기계학회 논문집
    • /
    • 제14권1호
    • /
    • pp.24-33
    • /
    • 2011
  • A circulating pump with installation space constraints was developed satisfying performance requirements such as flowrate, head and NPSHAv. The development procedures are composed of conceptual design, configuration design, performance analysis by CFD and performance test which were established in KIMM. The developed pump is OH4 type centrifugal pump which has a mixed-flow type impeller, a double volute and a rigid coupling. As a result of tests, the pump proved to meet all the requirements including space constraints and performance.

Waterjet 추진장치의 중량감소 펌프 개발 (Development of the Weight Reduction Pump for Waterjet Propulsionl)

  • 안종우;김건도;김기섭;박영하
    • 대한조선학회논문집
    • /
    • 제47권1호
    • /
    • pp.30-37
    • /
    • 2010
  • In order to control the weight balance of the waterjet propulsion ship, the pump's weight needed to be decreased. We reduced length of pump hub, overall length of pump and chord length of impeller and stator. To keep pump efficiency and cavitation performance similar to the $1^{st}$design pump, optimum design and experiment were conducted. This paper describes experimental method and numerical analysis for pump design. At the blade design stage, performance analysis of the pump is conducted using commercial CFD codes ($BladeGen^+$,CFX-10). Required performance and cavitation characteristics of the design pumps were measured and observed using the stand-alone test apparatus. The weight of the pump was successfully decreased through a series of pump design processes composed of blade design, performance analysis and model test.