• Title/Summary/Keyword: Mixed convection heat transfer

Search Result 73, Processing Time 0.027 seconds

Analysis of mixed convective laminar flow and heat transfer about a sphere (혼합대류에 의한 구 주위의 충류유동 및 열전달 해석)

  • 이준식;김택영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.11 no.2
    • /
    • pp.345-353
    • /
    • 1987
  • An analysis is performed to study flow and heat transfer characteristics of mixed free and forced convection about a sphere. Nonsimilar boundary layer equations which are valid over the entire regime of mixed convection are derived in terms of the mixed convection parameter, Gr/Re$^{2}$, through a dimensional analysis. The transformed conservation equations are solved by a finite difference method for the whole range of mixed convection regime. Numerical results for fluids having the Prandtl number 0.7 and 7 are presented. As the mixed convection parameter increases, the local friction coefficient and local heat transfer coefficient increases as well. For small Prandtl number, the friction coefficient is larger, while for large Prandtl number, the heat transfer coefficient is larger. Natural convection effect on the forced flow is more sensitive for small Prandtl number fluid. Flow separation migrates rearward as an increase in the mixed convection parameter. For small Prandtl number, the buoyancy effect is relatively small so that the flow separation occurs earlier.

Numerical Study on Combined Heat Transfer in NIR Dryer for Agricultural and Marine Products (근적외선 농수산물 건조기의 복합열전달특성에 관한 수치적 연구)

  • Choi, H.K.
    • Journal of Biosystems Engineering
    • /
    • v.31 no.5 s.118
    • /
    • pp.395-402
    • /
    • 2006
  • Mixed heat transfer in an indirected NIR (Near Infrared Ray) dry chamber was investigated numerical analysis. It is Important that the miked heat transfer effects on double parameters which the Reynolds number and the position of emit lamp. Reynolds number are based on the outer diameter of the cylinder range from 103 to $30{\times}105$. Four difference heat transfer regimes of behavior are apparent: forced convection and radiation on the outer surface of the cylinder, pure conduction, pure natural convection and radiation between lamp surface and inner surface of the cylinder. The temperature and flow patterns are illustrated by iso-contour lines for the double parameters. Also presented are results on the convective heat transfer flux and the radiative heat transfer flux as increased with Reynolds number.

Mixed Convection Heat Transfer in a Rectangular Enclosure with Various Outlets (좁은 환기구를 가진 사각공간에서의 혼합대류 열전달)

  • Lee, C.J.;Chung, H.S.;Kwon, S.S.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.7 no.2
    • /
    • pp.207-216
    • /
    • 1995
  • Flow and heat transfer characteristics of mixed convection heat transfer in a rectangular en-closure with various outlets are numerically investigated. The parameters considered here include Reynolds number, Grashof number and the position of outlet. The results show streamlines, isotherms, Nusselt numbers, velocity and temperature distributions. It has been shown that as Reynolds number increases, the size of cell decreases at Re$\leq$100 and increases at Re>100 for $Gr=10^4$. There is a minimum size of cells at Re=100, $Gr=10^4$. The maximum mean Nusselt number occurs at Re=400, $Gr=10^4$ and one right outlet. The mean Nusselt numbers can be formulated by the correlation equation $Nu=C{\cdot}Gr^a{\cdot}Re^b$.

  • PDF

Analysis of Mixed Convection Heat Transfer in Arbitrarily Shaped Flat Tubes (임의형상을 갖는 납작관에서의 혼합대류 열전달 해석)

  • 박희용;박경우;이상철
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.5
    • /
    • pp.398-410
    • /
    • 2001
  • The flow and heat transfer characteristics for three-dimensional mixed convection flows in a radiator flat tube with U--shaped grooves are analyzed numerically. The flow and temperature fields are calculated by using the modified SIMPLE algorithm for irregular geometry. One tube specification among the various flat tube exchangers is recommended by considering the heat transfer and pressure drop. The effects of variation of coolant flow conditions and external air conditions on the flow and the thermal characteristics for the selected tube are investigated. the results show that inlet velocity of coolant flow is the very important factor in heat transfer and pressure drop, and top side is better position than the others as fin cleave to tube.

  • PDF

Numerical Study on Convective Heat Transfer in a Compartment Fire(II) - Mixed Convection - (실내화재에 있어서의 대류열전달에 관한 수치연구(II) -혼합대류-)

  • 박외철;고경찬;이광진
    • Journal of the Korean Society of Safety
    • /
    • v.14 no.3
    • /
    • pp.33-39
    • /
    • 1999
  • In a compartment fire with openings, convective heat transfer consists of natural convection from the hot bodies and forced convection by airflow through the openings. The same finite volume method that was applied to pure natural convection in part I was utilized without modification to the square cavity with two openings. The objective of this study is to investigate effects of the openings on temperature distribution. Flow patterns, temperature distribution and heat transfer were compared for different Rayleigh numbers and with and without the openings.

  • PDF

Heat Transfer Characteristics of Radiation-Mixed Convection in a Three-Dimensional PCB Channel (3차원 PCB 채널내에서의 복사-혼합대류 열전달 특성)

  • Lee, J.H.;Park, K.W.;Pak, H.Y.
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.8 no.4
    • /
    • pp.561-575
    • /
    • 1996
  • The interaction of turbulent mixed convection and surface radiation in a three-dimensional channel with the heated blocks is analyzed numerically. Two blocks are maintained at high temperature and the other bottom and horizontal walls are insulated. S-4 method is employed to calculate the effect of the radiative heat transfer. The low Reynolds number k-$\varepsilon$ model proposed by Launder and Sharma is used to estimate the turbulent influence on the heat transfer enhancement. From above modeling, the effects of various channel specifications on the flow and heat transfer characteristics are investigated. The variables used for the present study are Reynolds number, block spacing, the channel height spacing for block and the emissivity. Average Nusselt numbers along the block surfaces are correlated and presented in terms of Reynolds number, emissivity and dimensionless geometric parameters. For the range of conditions in this study, average Nusselt numbers along the block surfaces are strongly influenced by the Reynolds numbers and channel height spacing for block but weakly influenced by the block spacing and the emissivity of the adiabatic walls.

  • PDF

Analysis of Three-Dimensional Mixed Convection Flow About Uniformly Distributed Heat-Generating Blocks on a Conductive Wall (기판 위에 분포된 발열블록 주위의 3차원 혼합대류 열전달 해석)

  • Yun, Byeong-Taek;Choi, Do Hyung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.23 no.1
    • /
    • pp.1-11
    • /
    • 1999
  • The three-dimensional laminar mixed convection flow between the conductive printed circuit boards. on which the heat generating rectangular blocks are uniformly distributed, has been examined in the present study. The flow and heat-transfer characteristics are assumed to be pseudo periodic in the streamwise direction and symmetric in the cross-stream direction. Using an algorithm of SIMPLER, the continuity equation. the Navier-Stokes equations and the energy equation are solved numerically in the three-dimensional domain Inside the channel. The convective derivative terms are discretized by the QUICK scheme to accurately capture the flow field. The flow and the heat transfer characteristics are thoroughly examined for various Re and Gr.

An Experiment and Numerical Analysis of Mixed Convection in a Rectangular Space with Variable Partition (가변 격판을 갖는 사각공간 내의 혼합대류에 대한 실험과 수치해석)

  • 이광성;신재호;이중섭;정한식;정효민
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.13 no.12
    • /
    • pp.1230-1235
    • /
    • 2001
  • The laminar convection heat transfer in a ventilated space with various horizontal partitions was studied numerically and experimentally. The experimental results by holographic interferometer showed good agreements with the numerical results. For the numerical study, the governing equations were solved by using a finite volume method for $46.6\leqRe\leq1332,\;1460\leqGr\leql1585$, Pr=0.71 and the variations of partition lengths. The isotherms and velocity vectors have been represented for various parameters. As the length of partition increases, the convection heat transfer decreases. Based on the numerical data, a correlation was obtained for the dimensionless mean Nusselt number in terms of $Gr/Re^2$. In the region of $Gr/Re^2$<1, the mean Nusselt number was very small, but in the region of $Gr/Re^2\geq1$, the mean Nusselt number was constant.

  • PDF

Mixed Convection in a Horizontal Annulus with a Rotating Cylinder (하나의 실린더가 회전하는 수평 환형 공간에서의 혼합 대류)

  • Yoo Joo-Sik;Ha Dae-Hong
    • Journal of computational fluids engineering
    • /
    • v.6 no.3
    • /
    • pp.1-9
    • /
    • 2001
  • Mixed convection in a horizontal annulus is considered, and the effect of a forced flow on the natural convective flow is investigated. The inner cylinder is hotter than the outer cylinder, and the outer cylinder is rotating with constant angular velocity with its axis at the center of the annulus. The unsteady streamfunction-vorticity equation is solved with a finite difference method. For the fluid with Pr=0.7, there appear flows with two eddies, one eddy, or no eddy according the Rayleigh and Reynolds numbers. The rotation of the outer cylinder reduces the heat transfer rate at the wall of the annulus. The oscillatory multicellular flow of a low Prandtl number fluid with Pr=0.01 can be effectively suppressed by the forced flow.

  • PDF

Mixed convection of air in a horizontal cylindrical annulus with rotating outer cylinder (회전하고 있는 바깥쪽 실린더를 갖고 있는 수평 원주형 환형 내에서의 공기의 혼합 대류)

  • Yu, Ju-Sik
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.21 no.4
    • /
    • pp.551-561
    • /
    • 1997
  • Mixed convection of air in a horizontal concentric cylindrical annulus is investigated numerically. Isothermal boundary conditions are prescribed at the inner and outer cylinders, with the inner cylinder being warmer. The forced flow is induced by the outer cylinder which is rotating slowly with constant angular velocity with its axis at the center of the annulus. The effect of the forced flow on the flow pattern and heat transfer of natural convection is investigated for the annulus of (inner-cylinder radius/gap width) = 1. There appear two eddies, one eddy or no eddy according to the Rayleigh and Reynolds numbers. Map of the three flow regimes is constructed on the Ra-Re plane. (author). 28 refs., 9 figs., 2 tabs.