• Title/Summary/Keyword: Mixed Loading

Search Result 405, Processing Time 0.029 seconds

단일과대하중의 작용모드가 피로균열의 전파거동에 미치는 영향 (Effects by Applying Mode of Single Overload on Propagation Behavior of Fatigue Crack)

  • 송삼홍;이정무
    • 한국정밀공학회지
    • /
    • 제21권6호
    • /
    • pp.109-116
    • /
    • 2004
  • In this study, when variable-amplitude load with various applying mode acts on the pre-crack tip, we examined how fatigue cracks behave. Hence aspects of the deformation caused by changing the applying mode of single overload and propagation behavior of fatigue crack were experimentally examined: What kinds of the deformation would be formed at pre-crack and its tip\ulcorner What aspects of the residual plastic deformation field would be formed in front of a crack\ulcorner How aspects of the plastic zone could be evaluated\ulcorner As applying mode of single overloading changes, the deformation caused by tensile and shear loading variously showed in each applying mode. The different aspects of deformation make influence on propagation behavior of cracks under constant-amplitude fatigue loading after overloading with various modes. We tried to examine the relationship between aspects of deformation and fatigue behavior by comparing the observed deformation at crack and crack propagation behavior obtained from fatigue tests.

Optimization of Process Condition for Fe Nano Powder Injection Molding

  • Oh, Joo Won;Lee, Won Sik;Park, Seong Jin
    • 한국분말재료학회지
    • /
    • 제24권3호
    • /
    • pp.223-228
    • /
    • 2017
  • Nanopowders provide better details for micro features and surface finish in powder injection molding processes. However, the small size of such powders induces processing challenges, such as low solid loading, high feedstock viscosity, difficulty in debinding, and distinctive sintering behavior. Therefore, the optimization of process conditions for nanopowder injection molding is essential, and it should be carefully performed. In this study, the powder injection molding process for Fe nanopowder has been optimized. The feedstock has been formulated using commercially available Fe nanopowder and a wax-based binder system. The optimal solid loading has been determined from the critical solid loading, measured by a torque rheometer. The homogeneously mixed feedstock is injected as a cylindrical green body, and solvent and thermal debinding conditions are determined by observing the weight change of the sample. The influence of the sintering temperature and holding time on the density has also been investigated. Thereafter, the Vickers hardness and grain size of the sintered samples have been measured to optimize the sintering conditions.

공기부상법을 이용한 활성슬러지의 부상분리 특성 (Thickening Characteristics of Activated Sludge by Air Flotation Process)

  • 박찬혁;홍석원;맹주원;이상협;최용수;문성용
    • 상하수도학회지
    • /
    • 제20권5호
    • /
    • pp.747-753
    • /
    • 2006
  • Air flotation is a solid-liquid separation process that utilizes up-flow microbubbles to thicken activated sludge and enhance clarification efficiency. Continuous air flotation experiments were performed to investigate the effect of operation parameters such as initial MLSS (mixed liquor suspended solid) concentration, air pressure, surface loading rate, air to solid (A/S) ratio, and flotation time on thickening efficiency. An initial activated sludge concentration ranged from 3,000 to 12,000mgSS/L and thickened sludge concentration varied from 6,400 to 28,100mgSS/L. The result showed that the thickening efficiency was mainly dependent on surface loading rate, A/S ratio, and flotation time. The pressure did not affect the thickening efficiency when it kept in the range of 1.6 to 1.8 bar. Experimental results showed that the thickening efficiency of activated sludge was increased only when the feed sludge concentration exceeded 5,000mgSS/L and the thickened concentration was over 20,000mgSS/L. At this time, SS concentration in the clarified liquid was ranged from 5 to 10mg/L.

Characterization of Vanadium Oxide Supported on Zirconia and Modified with MoO3

  • Sohn, Jong-Rack;Seo, Ki-Cheol;Pae, Young-Il
    • Bulletin of the Korean Chemical Society
    • /
    • 제24권3호
    • /
    • pp.311-317
    • /
    • 2003
  • Vanadium oxides supported on zirconia and modified with MoO₃were prepared by adding Zr(OH)₄powder into a mixed aqueous solution of ammonium metavanadate and ammonium molybdate followed by drying and calcining at high temperatures. The characterization of prepared catalysts was performed using FTIR, Raman spectroscopy and solid-state $^{51}V$ NMR. In the case of a calcination temperature of 773 K, for samples containing low loading of $V_2O_5$, below 15 wt %, vanadium oxide was in a highly dispersed state, while for samples containing high loading of $V_2O_5$, equal to or above 15 wt %, vanadium oxide was well crystallized because the $V_2O_5$ loading exceeded the formation of a monolayer on the surface of $ZrO_2$. The $ZrV_2O_7$ compound was formed through the reaction of $V_2O_5\;and\;ZrO_2$ at 873 K and the compound decomposed into $V_2O_5\;and\;ZrO_2$ at 1073 K, which were confirmed by FTIR spectroscopy and solid-state $^{51}V$ NMR. IR spectroscopic studies of ammonia adsorbed on $V_2O_5-MoO_3/ZrO_2$ showed the presence of both Lewis and Bronsted acids.

Experimental analysis of rocking shallow foundation on cohesive sand

  • Moosavian, S.M. Hadi;Ghalandarzadeh, Abbas;Hosseini, Abdollah
    • Earthquakes and Structures
    • /
    • 제22권6호
    • /
    • pp.597-608
    • /
    • 2022
  • One of the most important parameters affecting nonlinearsoil-structure interaction, especially rocking foundation, is the vertical factor of safety (F.Sv). In this research, the effect of F.Sv on the behavior of rocking foundations was experimentally investigated. A set of slow, cyclic, horizontal loading tests was conducted on elastic SDOF structures with different shallow foundations. Vertical bearing capacity tests also were conducted to determine the F.Sv more precisely. Furthermore, 10% silt was mixed with the dry sand at a 5% moisture content to reach the minimum apparent cohesion. The results of the vertical bearing capacity tests showed that the bearing capacity coefficients (Nc and Nγ) were influenced by the scaling effect. The results of horizontal cyclic loading tests showed that the trend of increase in capacity was substantially related to the source of nonlinearity and it varied by changing F.Sv. Stiffness degradation was found to occur in the final cycles of loading. The results indicated that the moment capacity and damping ratio of the system in models with lower F.Sv values depended on soil specifications such cohesiveness or non-cohesiveness and were not just a function of F.Sv.

알루미나 튜브의 인장/비틀림 조합하중하의 파괴거동 (Fracture Behaviors of Alumina Tubes under Combined Tension/Torsion)

  • 김기태;서정;조윤호
    • 한국세라믹학회지
    • /
    • 제28권1호
    • /
    • pp.19-19
    • /
    • 1991
  • 인장/비틀림 조합을력하에서 하중경로에 따른 Al₂O₃튜브 시편의 파괴거동을 조사하였다. 인장 후 비틀림을 한 하중경로(I)에서의 거시적인 균열의 전파방향과 파괴강도는 최대 주응력 파괴조건과 일치하였다. 전단응력(τ)/인장응력(σ)의 비가 일정한 하중경로(Ⅱ)에서의 거시적인 균열의 전파 방향은 최대 주응력 파괴조건과 일치한, 최대 주응력 파괴강도는τ/ σ의 비에 다라 일축인장 파괴 강도보다 증가 또는 감소하였다. Welbull 이론은 수누 비틀림에서의 최대 주응력 파괴 강도가 일죽이장 파괴강도보다 증가함은 예측하였으나, 하중경로(Ⅱ)에서 파괴 강도가 감소함은 예측할 수 없었다. 파괴강도가 일죽인장 파과강도보다 증가 또는 감소하는 현상은 미세조직의 관찰로 부터 미세결함면에 존재하는 전단응력이 파괴에 미치는 영향으로 설명하였다. 끝으로, 인위적 균열에서의 파괴 조건과 인장/비틀림 조합응력하의 Al₂O₃튜브 시편의 파괴 실험치에 근거한 새로운 경험식을 제안하였다. 제안된 파괴 조건식은 하중경로에 따른거시적인 균열의 전파방향과 파괴강도의 실험치와 잘 일치하였다.

시설하우스 농업배수 처리를 위한 인공습지에서 여재종류, 조합방법 및 부하량에 따른 오염물질 정화효율 평가 (Evaluation of Removal Efficiency of Pollutants in Constructed Wetlands for Treating Greenhouse Wastewater Under Different Filter Media, Configuration Methods and Agricultural Water Loading)

  • 이동진;박종환;김성헌;윤찬웅;조주식;이성태;허종수;서동철
    • 생태와환경
    • /
    • 제47권1호
    • /
    • pp.13-23
    • /
    • 2014
  • 본 연구는 시설하우스에서 비점오염원으로 인해 배출되는 오염된 농업배수를 인공습지에서 효과적으로 처리하기 위한 기초자료를 확보하기 위해 인공습지에서 여재종류, 조합방법 및 부하량에 따른 오염물질 정화효율을 평가하였다. 인공습지의 조합방법은 수직-수평흐름조, 수평-수직흐름조, 수평-수직-수평흐름조 및 수직-수평-수평흐름조로 구분하여 설계 및 시공하였으며, 여재는 왕사, 쇄석, 방해석 및 혼합여재로 구분하여 각 조에 충진하였다. 또한 농업배수 부하량을 150, 300, $600L\;m^{-2}day^{-1}$으로 달리하여 오염물질의 처리효율을 조사하였다. 조합방법별 수처리효율은 HF-VF-HF 조합방법이 다른 조합방법에 비해 높은 처리효율을 보였으며, 최적여재는 COD 처리효율은 왕사가 가장 높았고, T-N은 쇄석, T-P는 방해석이 가장 높았다. 하지만 모든 처리효율과 경제성 부분을 고려하였을 때 최적여재는 혼합여재가 가장 효과적일 것으로 판단된다. 농업배수의 부하량에 따른 처리효율 결과 COD는 농업배수 부하량 $600L\;m^{-2}day^{-1}$까지 안정적인 처리효율을 보였으나, T-N 및 T-P는 $150L\;m^{-2}day^{-1}{\fallingdotseq}300L\;m^{-2}day^{-1}$ > $600L\;m^{-2}day^{-1}$의 순으로 농업배수의 부하량이 증가함에 따라 약간 감소하는 경향이었다. 따라서 시설하우스 농업배수 처리를 위한 인공습지 농업배수처리장의 최적조건은 HF-VH-HF 조합형 인공습지에 왕사, 쇄석 및 방해석이 혼합된 혼합여 재로 충진하고 부하량 $300L\;m^{-2}day^{-1}$ 이하의 농업배수를 주입하는 것이 최적일 것으로 판단된다.

Evaluation of Secondary Acid and Enzymatic Hydrolysis of Hemicellulose in Hot Water Pre-Pulping Extract of Mixed Hardwoods

  • Um, Byung-Hwan
    • Journal of the Korean Wood Science and Technology
    • /
    • 제40권2호
    • /
    • pp.123-132
    • /
    • 2012
  • Pre-pulping extracts were found to contain a dilute amount of xylo-oligosaccharides and acetic acid as the major components, and many minor components including other organic acids, lignin-derived phenolics, and sugar degradation products. Once separated from the pulp, a secondary hydrolysis step was required to hydrolyze oligomeric hemicellulose sugars into monomeric sugars before fermentation. The following study detailed the extent of hemicellulose recovery by pre-pulping using hot water extraction and characterized the hydrolysis of the extract with respect to comparing acid and enzymatic hydrolysis. The secondaryhydrolysis of hot water extracts made at an H-Factor of 800 was tested for a variety of acid and enzyme loading levels using the sulfuric acid and xylanases. The maximum fermentable sugar yield from acid and enzyme hydrolysis of the extract was 18.7 g/${\ell}$ and 17.7 g/${\ell}$ representing 84.6% and 80.1% of the maximum possible yield, respectively.

활성슬러지공정에 의한 유기인계 농약폐수처리 (A Study on Agricultural the Treatment of Organic Phosphorous Agricultural Pesticides Wastewater by the Activated Sludge Process)

  • 최택열;최규철
    • 한국환경보건학회지
    • /
    • 제21권2호
    • /
    • pp.36-41
    • /
    • 1995
  • In order to treat effectively various type of wastewater discharged from the manufacture factory of organic phosphorous agricultural pesticides by the activated sludge process. The acclimation test of sludge was carried out by the dilution of completely mixed raw wastewater. The results of experiment were obstained as follows. 1. The moderate dilution rate of mixed raw wastewater was founded to about 30 times. 2. The available range of BOD-SS loading was 0.1~0.15 $kg\cdot BOD/kg\cdot SS\cdot day$ and it was similar to the case of extended aeration activated sludge process. 3. After the acclimation of activated sludge, the concentration of MLSS was 2000 mg/L, removal efficiency of BOD more than 90%, and SVI 100, respectively. 4. The oxygen respiratory rate of acclimated sludge was $47 mg\cdot O_2/g\cdot hr$ and this was increased about 5 times than $10 mg\cdot O_2/g\cdot hr$ of ordinary sludge.

  • PDF

Interface friction in the service load assessment of slab-on-girder bridge beams

  • Seracino, R.;Kerby-Eaton, S.E.;Oehlers, D.J.
    • Steel and Composite Structures
    • /
    • 제5권4호
    • /
    • pp.259-269
    • /
    • 2005
  • Many slab-on-girder bridges around the world are being assessed because they are approaching the end of their anticipated design lives or codes are permitting higher allowable loads. Current analytical techniques assume that the concrete and steel components act independently, typically requiring full-scale load testing to more accurately predict the remaining strength or endurance of the structure. However, many of the load tests carried out on these types of bridges would be unnecessary if the degree of interaction resulting from friction at the steel-concrete interface could be adequately modeled. Experimental testing confirmed that interface friction has a negligible effect on the flexural capacity of a slab-on-girder beam however, it also showed that interface friction is significant under serviceability loading. This has led to the development of an improved analytical technique which is presented in this paper and referred to as the slab-on-girder mixed analysis service load assessment approach.