• Title/Summary/Keyword: Mitral valve replacement

Search Result 336, Processing Time 0.021 seconds

Aortic Stenosis in Systemic Lupus Erythematosus Syndrome (전신성 흥반성 낭창에 동반된 대동맥 판막 협착증의 수술 1에)

  • 최주원;김우식;고행일;강윤경;김용인
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.613-616
    • /
    • 2004
  • Systemic lupus erythemotosus (SLE) is an autoimmune disorder with dermal, renal, and cardiac manifestations. It frequently has cardiovascular complications such as pericarditis, myocarditis, and valvular heart diseases. Valvular heart diseases in SLE comes mainly in the form of mitral or aortic insufficiencies. Report of aortic stenosis is extremely rare. Surgical treatments of valvular heart disease in SLE are not done frequently because of complications in other organs. Aortic stenosis developed in a 59 year-old woman with SLE, and aortic valve replacement was done successfully.

Surgical Treatment of the Wolff-Parkinson-White Syndrome (Wolff-Parkinson-White 증후군의 외과적 치료)

  • 박남희;이광숙
    • Journal of Chest Surgery
    • /
    • v.29 no.12
    • /
    • pp.1373-1376
    • /
    • 1996
  • From October 1993 to February 1996, 9 patients with Wolfr-Parkinson-White syndrome underwent surgical ablation of the accessory atrioventricular conduction pathways. The indications for surgical ablation we e radiofrequency ablation failure in 6 cases, multiple accessory pathways in 1 case, catheter tip fracture ducting catheter ablation in 1 case and additional procedure(redo mitral valve replacement due to valve thrombosis) in 1 case. There was no operative mortality. The postoperative complications were noted In 2 cases pericardial effusion and wound Infection. All patients had accessory atrioventricular connections ablated which were proven by surface ECG and follow-up electrophysiologic study and have remained free of symptomatic tachycardia. The indications for surgical treatment of Wolff-Parkinson-White syndrome are radiofrequency ablation failure, multiple pathways, or when additional procedures are required The present results were satisfactory.

  • PDF

승모판막질환에 병발한 동맥색전증의 치험 1례

  • Hur, Y.;Kim, B.Y.;Lee, H.S.;Kim, J.E.;Lee, J.H.;Yu, H.S.
    • Journal of Chest Surgery
    • /
    • v.13 no.1
    • /
    • pp.77-81
    • /
    • 1980
  • We present one case of 26-year-old male having saddle block combined with mitral valvular disease [NYHA Class IV] with auricular fibrillation. The most common cause of emboli is atrial fibrillation. The clinical manifestations of saddle emboli are relatively slow due to development of collateral circulation and large size of lumen of the aorta. The 5month duration of saddle emboli in this case led to severe atrophic changes, coldness, peripheral cyanosis on the both lower extremities, and flexion deformity on the knee and ankle joint of the left lower extremity. We planned staged operation for the saddle block and for mitral stenoinsufficiency and tricuspid insufficiency, because of poor general condition of the patient. The thromboembolectomy of aortic bifurcation was performed through the transabdominal approach without trial of Fogarthy catheter embolectomy, because of expectation of the secondary inflammatory changes of the vessel wall and thrombi which was 3 cm X 1 cm X 0.5 cm in size with irregular surfaced solid in consistency. 1 month later, after thromboembolectomy, mitral valve replacement and tricuspid annuloplasty were performed, with successful early operative result. During operation organized thrombi [1 cm X 0.5 cm] in the left auricle was removed. We wonder if simple management using Fogarthy catheter might be possible to remove the thromboemboli instead of thromboembolectomy by aortotomy in this case.

  • PDF

Protamine Induced Anaphylactic Reaction after Cardiopulmonary Bypass -A case report- (체외순환 후 에 의해 유발된 아나필락시스 반응 - 1예 보고-)

  • 백종현;한승세;이정철;정태은;이장훈;이동협
    • Journal of Chest Surgery
    • /
    • v.37 no.7
    • /
    • pp.606-608
    • /
    • 2004
  • Anaphylactic reaction to protamine sulfate, which is used widely to reverse the anticoagulative effect of heparin after cardiopulmonary bypass, is very rare. But the result of anaphylactic reaction can be very fatal and the mechanism of it is still not clear. We report. a. case of severe anaphylactic reaction to protamine sulfate following the replacement of the mitral valve and .Maze procedure using microwave in a non-diabetic 57-year-old female patient.

Minimal Invasive cardiac Surgery ; Small Submammary Incision (유방하 횡절개를 이용한 최소침습 심장수술)

  • 정승혁;신용철;임용택;김병일;이정호
    • Journal of Chest Surgery
    • /
    • v.33 no.1
    • /
    • pp.96-98
    • /
    • 2000
  • A cosmetic incision for minimal invasive cardiac surgery is described. Through a small submammary skin incision combined with partial low sternotomy some kinds of cardiac operations are possible without extra-difficulty but with excellent cosmetic effect, No special instruments nor techniques are required. By this method routine cannulations for cardiopulmonary bypass as well as aortic cross clamping bicaval snaring and venting of cardiac chambers are possible, We performed 5 cases of open heart surgeries using this approach which includes two cases of atrial septal defect closure one case of ventricular septal defect closure one case of pulmonic valvotomy and one case of mitral valve replacement.

  • PDF

Long Term Results of Valve Replacement with the St. Jude Medical Heart Valves: Thirteen Year Experience (St. Jude 기계판막을 이용한 판막 치환술의 장기 성적)

  • Kim, Chang-Gon;Gu, Ja-Hong;Jo, Jung-Gu;Kim, Gong-Su
    • Journal of Chest Surgery
    • /
    • v.30 no.9
    • /
    • pp.891-898
    • /
    • 1997
  • Between May 1984 and January 1996, 130 patients were replaced cardiac valve using 150 St. Jude Medical prosthetic valves(42 aortic, 68 mitral, 20 aortic and mitral valve replycements). Follow-up was 97.6% complete. The early mortality rate was 5.4%, and late mortality rate was 4.9%. The valve-related late mortality rate was 3.3%. Of late complications, there were 6 anticoagulant related hemorrhages, 4 thromboembolisms and 1 paravalvular leakage. Linearized rates of late complication and valve-related late mortality were as follows: total late complications, .1.68o per patient-year: anticoagulant related hemorrhages, 0.92% per patient-year: thromboembolism, 0.61% per patient-year: paravalvular leakage, 0.15% per patient-year: reoperation, 0.15% per patient-year: and valve-related late mortalities, 0.61% per patient-year. Actuar al event free rate at 10 years was 87.4 $\pm$ 3.2%. The overall actuarial survival rate was 90.4$\pm$2.7% at 5 years, 87.5$\pm$3.3% at 10 years. Ninety eight percent of the survivors were in the New York Heart Association functional class I or II at the end of follow-up. There was significant improvement of cardiothoracic ratio. In conclusion, this study suggests the excellent durability of the St. Jude Medical Heart valve and remarkable functional benefit for the majority of the patients. However, prosthesisrelated complications are still common. Outcome is strongly related to the patient's preoperative cardiac condition and to the adequacy of anticoagulation control.

  • PDF

Mitral Annular Tissue Velocity Predicts Survival in Patients With Primary Mitral Regurgitation

  • You-Jung Choi;Chan Soon Park;Tae-Min Rhee;Hyun-Jung Lee;Hong-Mi Choi;In-Chang Hwang;Jun-Bean Park;Yeonyee E. Yoon;Jin Oh Na;Hyung-Kwan Kim;Yong-Jin Kim;Goo-Yeong Cho;Dae-Won Sohn;Seung-Pyo Lee
    • Korean Circulation Journal
    • /
    • v.54 no.6
    • /
    • pp.311-322
    • /
    • 2024
  • Background and Objectives: Early diastolic mitral annular tissue (e') velocity is a commonly used marker of left ventricular (LV) diastolic function. This study aimed to investigate the prognostic implications of e' velocity in patients with mitral regurgitation (MR). Methods: This retrospective cohort study included 1,536 consecutive patients aged <65 years with moderate or severe chronic primary MR diagnosed between 2009 and 2018. The primary and secondary outcomes were all-cause and cardiovascular mortality, respectively. According to the current guidelines, the cut-off value of e' velocity was defined as 7 cm/s. Results: A total of 404 individuals were enrolled (median age, 51.0 years; 64.1% male; 47.8% severe MR). During a median 6.0-year follow-up, there were 40 all-cause mortality and 16 cardiovascular deaths. Multivariate analysis revealed a significant association between e' velocity and all-cause death (adjusted hazard ratio [aHR], 0.770; 95% confidence interval [CI], 0.634-0.935; p=0.008) and cardiovascular death (aHR, 0.690; 95% CI, 0.477-0.998; p=0.049). Abnormal e' velocity (≤7 cm/s) independently predicted all-cause death (aHR, 2.467; 95% CI, 1.170-5.200; p=0.018) and cardiovascular death (aHR, 5.021; 95% CI, 1.189-21.211; p=0.028), regardless of symptoms, LV dimension and ejection fraction. Subgroup analysis according to sex, MR severity, mitral valve replacement/repair, and symptoms, showed no significant interactions. Including e' velocity in the 10-year risk score improved reclassification for mortality (net reclassification improvement [NRI], 0.154; 95% CI, 0.308-0.910; p<0.001) and cardiovascular death (NRI, 1.018; 95% CI, 0.680-1.356; p<0.001). Conclusions: In patients aged <65 years with primary MR, e' velocity served as an independent predictor of all-cause and cardiovascular deaths.

Changes of Myocardial Ultrastructure During Open Heart Surgery (개심수술중 심근 미세구조의 변화)

  • Hur, Jin;Kong, Joon-Hyuk;Lee, Jong-Tae
    • Journal of Chest Surgery
    • /
    • v.33 no.9
    • /
    • pp.707-715
    • /
    • 2000
  • Background: Cold blood cardioplegic solution has been used to protect myocardium during open heart surgery with the hypothesis stating that it provides more oxygen supply to myocardium compared to crystalloid caridoplegic solution. We repeatedly infused cold blood cardioplegic solution to achieve myocardial protection. We biopsied a small portion of papillary muscle of patients with mitral valve replacement or double valve replacement during aortic cross-clamp time and evaluated the method of myocardial protection through the observation of changes in ultrastructure. We then analysed the relationship between changes in ultrasructure and peak postoperative CK-MB value and SGOT value. Material and method: We report observation on changes of myocardial ultrastructure, postoperative CK-MB and SGOT, and electrocardiogram in 31 patients who underwent cardiac operation. There were 11 males and 20 females, and they ranging in age from 28 to 69 years(mean score was 2.08$\pm$0.560, it was 2.37$\pm$0.558 at 40 minutes, and it was 2.36$\pm$0.523 at 70minutes. Mitochondrial score increased significant at 40 minutes. Mean value of postoperative peak CK-MB and SGOT were 37.3$\pm$17.061IU, 144.5$\pm$125.5IU respectively. We were not able to find any new Q were in EKG after the operation. There was no significant relationship between myocardium mitochondrial score and mean value of postoperative peak CK-MB and SGOT. Conclusion: In conclusion, with this study the cold blood cardioplegic solution was incomplete in preserving ultrastructure of myocardium even with satisfactory results in serum enzyme and EKG evaluation.

  • PDF

Initial Experience of Robotic Cardiac Surgery (수술로봇을 이용한 심장수술 첫 체험)

  • Cho Sung Woo;Chung Cheol Hyun;Kim Kyoung Sun;Choo Suk Jung;Song Hyung;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.5 s.250
    • /
    • pp.366-370
    • /
    • 2005
  • Background: In general, cardiac surgery has been performed via median sternotomy. During the past decade, improvements in endoscopic equipment and operative techniques have resulted in development of minimally invasive cardiac operation using small incisions. With the advent of a voice controlled camera-holding robotic arm (AESOP 3000, Automated Endoscope System for Optimal Positioning), cardiac surgery entered the robotic age. Material and Method: Between April 2004 and December 2004, a total of seventy eight patients underwent robotic cardiac surgery, of whom sixty four patients underwent robot-assisted minimally invasive cardiac surgery via 5cm right lateral minithoracotomy using voice controlled robotic arm, femoral vessels cannulation, percutaneous internal jugular cannulation, transthoracic aortic cross clamp. Other fourteen patients underwent MIDCAB via internal mammary artery harvesting using AESOP. Result: Robotic cardiac surgery were mitral valve repair in 37 cases, mitral valve replacement in 10 cases, aortic valve replacement in 1 case, MIDCAB in 14 cases, ASD operation in 9 cases, and isolated Maze procedure in 1 case. In mitral operation, mean CPB time was $165.3\pm43.1$ minutes and mean ACC time was $110.4\pm48.2$ minutes. Median length of hospital stay was 6 days (range 3 to 30) in mitral operation, 4 days (range 2 to 7) in MIDCAB, and 4 days (range 2 to 6) in ASD operation. For complications, 3 patients were required by reoperation for bleeding. There was no hospital mortality. Conclusion: Our experience of robot cardiac surgery suggests that many cardiovascular surgeons will be able to perform minimally invasive cardiac operations through small incisions with robot-assisted video-direction. Well-designed studies and close long-term follow-up will be required to analyze the benefits of robot-assisted operation.

Case Report of Partial Endocardial Cushion Defect with Mild Pulmonary Hypertension in Old Age (경증의 폐동맥 고혈압을 동반한 고령에서의 심내막상 결손 환자 치험 1예)

  • Kim Woo-Shik;An Jae-Bum;Song Chang-Min;Kim Mi-Jung;Jung Sung-Chol;Shin Yong-Chul;Kim Byung-Yul;Kim In-Sub
    • Journal of Chest Surgery
    • /
    • v.39 no.8 s.265
    • /
    • pp.633-636
    • /
    • 2006
  • The partial endocardial cushion defect including ostium primum atrial septal defect and anterior mitral leaflet cleft, presents less significant clinical symptoms than complete endocardial cushion defect. But, as mitral insufficiency develops, cardiomegaly, congestive heart failure, pulmonary arterial hypypertension appear. So, partial endocardial cushion defect has poor prognosis and is rarely seen in elderly patients. A 67 years old woman admitted at our hospital for operative treatment with partial endocardial cushion defect. She had increased pulmonary pressure of 45/22 mmHg, mean 32 mmHg. She had repair of ostium primum defect with patch, and the mitral valve was treated with valve replacement. Because advanced atrioventricular block developed postoperatively, she received permanent pacemaker.