• Title/Summary/Keyword: Mitral valve disease

Search Result 214, Processing Time 0.023 seconds

Assessment of radiographic left atrial dimension and C-reactive protein in dogs with myxomatous mitral valve disease

  • Jihee Hong;Han-Joon Lee;Dong-Kwan Lee;Kun-Ho Song
    • Korean Journal of Veterinary Service
    • /
    • v.47 no.1
    • /
    • pp.1-7
    • /
    • 2024
  • Radiographic left atrial dimension (RLAD) is a valuable metric for assessing left atrial enlargement in dogs. While there have been studies on the use of RLAD and the increase in C-reactive protein (CRP) levels based on heart disease stages, there has been no prior research on the correlation between RLAD and CRP. In this study, the objective was to investigate the relationship between the rise in RLAD as myxomatous mitral valve disease (MMVD) stages advance and the increase in CRP levels with MMVD stage progression. In this study, a total of 30 small-breed dogs were included as subjects. These dogs were diagnosed with MMVD at the American College of Veterinary Internal Medicine (ACVIM) stage B1 or B2, or stage C, based on a comprehensive assessment including physical examination, thoracic radiography, and echocardiography. Measurements of VHS and RLAD were compared to assess any significant differences. There were significant differences in RLAD between dogs with MMVD ACVIM stage B1 and those with stage C. The monocytes and CRP levels showed significant differences between ACVIM stage B1, B2 and ACVIM C. Additionally, a significant correlation was observed between the RLAD and VHS measurements. This underscores the notable association between MMVD stage advancement and elevated monocyte and CRP levels. The RLAD scores exhibited a significant difference among dogs with ACVIM stages B1, B2, and C, and significant variations were also observed in monocyte and CRP levels. These results suggest that monocyte and CRP levels may be a valuable diagnostic indicator for heart disease in dogs during the diagnostic evaluation.

Aortic Valve Replacement Using Continuous Suture Technique in Patients with Aortic Valve Disease

  • Choi, Jong Bum;Kim, Jong Hun;Park, Hyun Kyu;Kim, Kyung Hwa;Kim, Min Ho;Kuh, Ja Hong;Jo, Jung Ku
    • Journal of Chest Surgery
    • /
    • v.46 no.4
    • /
    • pp.249-255
    • /
    • 2013
  • Background: The continuous suture (CS) technique has several advantages as a method for simple, fast, and secure aortic valve replacement (AVR). We used a simple CS technique without the use of a pledget for AVR and evaluated the surgical outcomes. Materials and Methods: Between October 2007 and 2012, 123 patients with aortic valve disease underwent AVR alone (n=28) or with other concomitant cardiac procedures (n=95), such as mitral, tricuspid, or aortic surgery. The patients were divided into two groups: the interrupted suture (IS) group (n=47), in which the conventional IS technique was used, and the CS group (n=76), in which the simple CS technique was used. Results: There were two hospital deaths (1.6%), which were not related to the suture technique. There were no significant differences in cardiopulmonary bypass time or aortic cross-clamp time between the two groups for AVR alone or AVR with concomitant cardiac procedures. In the IS group, two patients had prosthetic endocarditis and one patient experienced significant perivalvular leak. These patients underwent reoperations. In the CS group, there were no complications related to the surgery. Postoperatively, the two groups had similar aortic valve gradients. Conclusion: The simple CS method is useful and secure for AVR in patients with aortic valve disease, and it may minimize surgical complications, as neither pledgets nor braided sutures are used.

Global Left Ventricular Myocardial Work Efficiency in Patients With Severe Rheumatic Mitral Stenosis and Preserved Left Ventricular Ejection Fraction

  • Estu Rudiktyo;Amiliana M Soesanto;Maarten J Cramer;Emir Yonas;Arco J Teske;Bambang B Siswanto;Pieter A Doevendans
    • Journal of Cardiovascular Imaging
    • /
    • v.31 no.4
    • /
    • pp.191-199
    • /
    • 2023
  • BACKGROUND: Assessment of left ventricular (LV) function plays a pivotal role in the management of patients with valvular heart disease, including those caused by rheumatic heart disease. Noninvasive LV pressure-strain loop analysis is emerging as a new echocardiographic method to evaluate global LV systolic function, integrating longitudinal strain by speckle-tracking analysis and noninvasively measured blood pressure to estimate myocardial work. The aim of this study was to characterize global LV myocardial work efficiency in patients with severe rheumatic mitral stenosis (MS) with preserved ejection fraction (EF). METHODS: We retrospectively included adult patients with severe rheumatic MS with preserved EF (> 50%) and sinus rhythm. Healthy individuals without structural heart disease were included as a control group. Global LV myocardial work efficiency was estimated with a proprietary algorithm from speckle-tracking strain analyses, as well as noninvasive blood pressure measurements. RESULTS: A total of 45 individuals with isolated severe rheumatic MS with sinus rhythm and 45 healthy individuals were included. In healthy individuals without structural heart disease, the mean global LV myocardial work efficiency was 96% (standard deviation [SD], 2), Compared with healthy individuals, median global LV myocardial work efficiency was significantly worse in MS patients (89%; SD, 4; p < 0.001) although the LVEF was similar. CONCLUSIONS: Individuals with isolated severe rheumatic MS and preserved EF, had global LV myocardial work efficiencies lower than normal controls.

Coronary Artery Fistula Associated with Valvular Heart Disease (심장판막증에 동반된 관상동맥루 -1례 보고-)

  • 백완기
    • Journal of Chest Surgery
    • /
    • v.23 no.1
    • /
    • pp.158-161
    • /
    • 1990
  • A congenital coronary artery fistula is an uncommon anomaly which has a direct communication between a coronary artery and the lumen of any one of the four cardiac chambers, or the coronary sinus, or its tributary veins or the superior vena cava. The right coronary artery is involved most frequently, and the abnormal communication in most often is to the right ventricle followed in incidence by drainage into the right atrium and the pulmonary artery. Recently. we experienced a case of congenital coronary artery fistula associated with valvular heart disease. The fistulous communication was noted between the left circumflex artery and the left atrial appendage. Under the cardiopulmonary bypass, the internal obliteration of the left atrial appendage, mitral valve replacement, and aortic valve exploration were accomplished. Postoperative hospital course was uneventful and the patient was discharged without any problems.

  • PDF

Anatomically Corrected Malposition of the Great Arteries One Case Report (Anatomically Corrected Malposition of the Great Arteries 1례 보고)

  • 정덕용
    • Journal of Chest Surgery
    • /
    • v.18 no.4
    • /
    • pp.557-562
    • /
    • 1985
  • One case of anatomically corrected malposition of the great arteries was managed at department of cardiothoracic surgery, Chungnam National University Hospital at May, 1984. Anatomically corrected malposition of the great arteries was an extremely rare congenital heart disease. Only 21 cases were reported in English literatures. If there are no associated cardiac disease, the patient will have normal life span. This 39 year old man had suffered from exertional dyspnea for 6 years. He had carried out normal military service as a sergeant for 8 years, and his life was not restricted before this episode. He had operated under diagnosis of mitral stenoinsufficiency & tricuspid regurgitation but died because of lower cardiac output.,br> At autopsy, the great arteries were malpositioned but viscera and lung were normal position and picture. The aortic valve was located left and anterior to the pulmonic valve and there are bilateral conus in this anatomically corrected malposition of the great arteries. The coronary arteries were normal distribution.

  • PDF

Clinical Experiences for Cardiac Myxomas (심장 점액종의 임상적 고찰)

  • Lee, Geun-Dong;Lee, Jae-Won;Jung, Jae-Seung;Jung, Sung-Ho;Je, Hyoung-Gon;Choo, Suk-Jung;Song, Hyun;Chung, Cheol-Hyun
    • Journal of Chest Surgery
    • /
    • v.41 no.6
    • /
    • pp.703-709
    • /
    • 2008
  • Background: Diagnosis and treatment are often successful in the setting of cardiac myxomas. However, cardiac myxomas can lead to catastrophic complications, due to intracardiac obstruction and embolism preoperatively, and can recur postoperatively. Material and Method: We retrospectively reviewed the clinical characteristics, surgical treatment, and recurrence data of 85 patients who underwent cardiac myxoma surgery at Asan Medical Center between November 1994 and June 2007. We analyzed the morphologic characteristics of 58 patients with left atrial myxomas and determined the development of functional mitral valve stenosis and systemic embolism through reviewing the results of preoperative echo-cardiograms to find potential preoperative risk factors. Result: Twenty-seven (31.8%) patients were men, and 58 (68.2%) were women. The mean patient age was $54.5{\pm}14.3$ years. Preoperative symptoms included obstructive symptoms in 41 (48.2%) patients, signs of embolism in 19 (22.4%), constitutional symptoms in 8 (9.4%), and no symptoms in 19 (20.0%). Among the 58 patients with left atrial myxomas, the mean maximal tumor diameter was $4.3{\pm}1.8$ (range $1.1{\sim}8\;cm$)cm. Twenty-six (44.8%) patients had a prolapsing type, defined as a tumor mobile enough to move down. to the mitral. annular plane during diastole, and 32 (55.2%) had villous type, defined as a tumor consisting of multiple fine villous extensions on the surface. Twelve (20.7%) patients had severe functional mitral valve stenosis, and 15 (25.9%) had systemic embolism preoperatively. The incidence of severe functional mitral valve stenosis was significantly higher in patients with the prolapsing type than in those with the non-prolapsing type (p=0.001). The mean maximal tumor diameter in patients with severe functional mitral valve stenosis was $5.1{\pm}1.0\;cm$, significantly larger than that seen in patients without severe functional mitral valve stenosis (p=0.041). The incidence of systemic embolism was significantly higher in patients with the villous type than in those with the smooth type (p=0.006). Postoperative complications were noted in 6 (7.1%) patients, and early mortality was noted in 1 (1.2%). The mean postoperative follow-up duration was $36.2{\pm}37.5$ months, with recurrence reported in 2(2.4%) patients during the follow-up period. The disease free interval were 48, 12 months, respectively. Conclusion: Surgical treatment for cardiac myxomas was performed safely, and long-term prognosis was good. In patients with left atrial myxoma, close attention should be maintained and surgery should be performed promptly in those of prolapsing type, those with large maximal diameter in order to prevent severe functional mitral valve stenosis, and those of villous type in order to prevent systemic embolism. Echocardiography should be followed serially in order to detect recurrence.

Reoperations for valvular heart disease: report of 29 cases (심장판막 재수술: 29례 보)

  • 김은기
    • Journal of Chest Surgery
    • /
    • v.16 no.4
    • /
    • pp.498-505
    • /
    • 1983
  • It has been over 20 years since successful operations of Cardiac valves at the Department of Thoracic and Cardiovascular surgery, college of medicine, Yonsei University. About six hundreds of patients with severely symptomatic valvular heart disease have had valve operations with complete loss or sharp decrease in their cardiac symptoms since 1956. As the number of cardiac patient increases, reoperation on valves assumes greater importance. To define the group of patients undergoing reoperations on valves and the factors influencing their survival, we have reviewed our experiences of the reoperation on valves at the Yonsei University, Severance Hospital. This is a report of 29 cases which was undergone secondary or more surgery for valvular heart disease from 1966 to 1983. The primary operations includes 159 cases of open heart surgery from 1966 to 1975 and 476 cases from 1976 to march, 1983. The secondary operations are classified into groups of secondary valvuloplasty or valvotomy [8 cases], prosthetic valve replacement following valvuloplasty or valvotomy [14 cases] and prosthetic valve rereplacement [2 case] for such as calcification, degeneration and perforation of the cusps and paravalvular leakage, of the bioprosthetic valves. The leading indication for reoperation of mitral valve was restenosis or stenoinsufficiency, The indications of aortic valve replacement was active bacterial endocarditis, medically uncontrollable prosthetic endocarditis or paravalvular leakage. Overall death rate of the reoperation was 17.4% [5 death among the 29 patients] and the leading causes of death were myocardial failure, arrhythmia, cerebral embolism, acute renal failure due to low output syndrome. And it was followed by sepsis associated with active prosthetic endocarditis. The death rate of reoperation was 4.3% in the elective cases except urgent cases and the death rate of overall cardiac valve except reoperation cases was 4.1% in the last two years. Although the general mortality of reoperation was high, both mortality rates were comparable except emergency cases due to urgent preoperative patient’s condition.

  • PDF

Serum nitrotyrosine concentration in dogs with myxomatous mitral valve disease

  • Kim, Jun-Seok;Park, Jun-Seok;Park, Hyung-Jin;Seo, Kyoung-Won;Song, Kun-Ho
    • Korean Journal of Veterinary Research
    • /
    • v.57 no.1
    • /
    • pp.17-21
    • /
    • 2017
  • The aim of this study was to compare serum nitrotyrosine concentrations in healthy dogs with those in dogs with myxomatous mitral valve disease (MMVD). Fifty client-owned dogs were included in this study. Based on echocardiographic results, dogs were categorized into healthy (control), mild-, moderate-, and severe-MMVD groups. Serum nitrotyrosine concentrations were determined from enzyme-linked immunosorbent assays. No significant difference between control dogs and dogs with mild MMVD was detected (p = 0.31). However, dogs with moderate MMVD had significantly higher serum concentrations of nitrotyrosine (p = 0.04) than that in controls, and dogs with severe MMVD had significantly lower serum concentrations of nitrotyrosine (p = 0.03) than that in moderate MMVD dogs. There were negative correlations in the association of serum nitrotyrosine with age (n = 30, $R^2=0.067$, p = 0.27), left atrial-to-aortic root diameter ratio (n = 30, $R^2=0.02$, p = 0.57), and platelet count (n = 30, $R^2=0.39$, p = 0.003); however, only the platelet correlation was significant. Among dogs with MMVD, there was no significant difference in serum nitrotyrosine concentration between males and females. The results of this study suggest that tyrosine nitration end-products might be potential biomarkers for the detection of MMVD in dogs.

Analysis of Recurred Mitral Regurgitation after Mitral Repair according to Procedure or Valve Related Causes (승모판막 성형술 후 재발의 원인에 대해 술기와 판막 요인에 대한 분석)

  • Shin Hong Ju;Yoo Dong Gon;Lee Yong Jik;Park Soon Ik;Choo Suk Jung;Song Hyun;Chung Cheol Hyun;Song Meong Gun;Lee Jae Won
    • Journal of Chest Surgery
    • /
    • v.38 no.2 s.247
    • /
    • pp.132-138
    • /
    • 2005
  • Background: Mitral valve repair (MVP) is the optimal procedure for mitral regurgitation (MR), however, failure and subsequent reoperations are the limitations. The current study assessed the procedure in relation to the primary valve related causes of recurrent MR. Material and Method: MR was treated in 493 patients undergoing MVP from January of 1994 to January of 2002. The causes of MR were degenerative $(n=252,\;51.5\%),$ rheumatic $(n=156,\; 31.6\%),$ and others $(n=85,\; 16.9\%).$ Surgery comprised 446 ring annuloplasties $(90.5\%),$ 227 new chordae formations $(46\%),$ 125 quadriangular resections $(25.3\%),$ 28 chordae transfers $(5.7\%),$ and 8 Alfieri's stitches $(1.6\%).$ The mean follow up was $29.04\pm22.81$ months. Result: There were 5 early $(1.01\%)$, and 5 late deaths $(1.01\%).$ The reoperation rate was $1.42\%$. There were 45 $(9.1\%)$ recurrent MR (grade III or IV). Of these, 24 were procedure related including incomplete repair (n=14), discordant new chordae length (n=8) and others (n=2). In 21 patients, the cause was valve related including rheumatic disease progression (n=10), recurrent chordae elongation or prolapse (n=5) and others (n=6). Severe MR was higher after incomplete repair (p < 0.001), and valve related failure strongly correlated with rheumatic progression (p < 0.05). Conclusion: Since completeness of operation is the prime risk factor that determine the repair durability, intra-operative assessment of the initial repair with trans-esophageal echocardiography is essential.

Twenty-year Experience of Mitral Valve Replacement with the St. Jude Medical Mechanical Valve Prosthesis (St. Jude 기계 판막을 이용한 승모판막 치환술의 20년 장기성적)

  • Seo Yeon-Ho;Kim Kong-Soo;Jo Jung-Ku
    • Journal of Chest Surgery
    • /
    • v.39 no.7 s.264
    • /
    • pp.527-533
    • /
    • 2006
  • Background: A retrospective study was conducted to analyze the results of St. Jude Medical mitral valve replacement at the Chonbuk National University Hospital since the initial implant in May 1984. Material and Method: Between May of 1984 and December of 1996, 95 patients underwent MVR with the St. Jude Medical mechanical valve prosthesis at Department of Medical Science of Chonbuk National University Hospital and follow-up ended in May of 2004. Result: Age ranged from 19 to 69 years. Follow-up (mean${\pm}$standard deviation) averaged $10.6{\pm}4.2\;year$. Thirty-day operative mortality was 4.2% (4/95). Nine late deaths have occurred and actuarial survival was $90.5{\pm}3.0%,\;87.9{\pm}3.4%\;and\;83.2{\pm}4.6%$ at 5, 10 and 20 years, respectively. Probability of freedom from valve-rotated death was $95.5{\pm}2.1%,\;94.3{\pm}2.4%\;and\;91.0{\pm}3.9%$ at 5, 10 and 20 years, respectively. Seven patients have sustained thromboembolic events (1,05%/patient-year). Fifteen patients had anticoagulation related hemorrhage (3.56%/patient-year). There was no structural valve deterioration. Probability of freedom from all complications was $82.0{\pm}3.9%,\;71.3{\pm}4.8%\;and\;42.4{\pm}10.5%$ at 5, 10 and 20 years, respectively. Conclusion: We confirm the effective and excellent durability of the St. Jude Medical prosthesis in the mitral position with a low event rate at long-term follow-up. It also demonstrates the commonly encountered practical difficulty of adjusting the anti-coagulation protocol in patients with prosthetic mitral valves.