• Title/Summary/Keyword: Misfit

검색결과 147건 처리시간 0.022초

Anisotropic, non-uniform misfit strain in a thin film bonded on a plate substrate

  • Huang, Y.;Ngo, D.;Feng, X.;Rosakis, A.J.
    • Interaction and multiscale mechanics
    • /
    • 제1권1호
    • /
    • pp.123-142
    • /
    • 2008
  • Current methodologies used for the inference of thin film stresses through curvature measurements are strictly restricted to stress and curvature states which are assumed to remain uniform over the entire film/substrate system. These methodologies have recently been extended to non-uniform stress and curvature states for the thin film subject to non-uniform, isotropic misfit strains. In this paper we study the same thin film/substrate system but subject to non-uniform, anisotropic misfit strains. The film stresses and system curvatures are both obtained in terms of the non-uniform, anisotropic misfit strains. For arbitrarily non-uniform, anisotropic misfit strains, it is shown that a direct relation between film stresses and system curvatures cannot be established. However, such a relation exists for uniform or linear anisotropic misfit strains, or for the average film stresses and average system curvatures when the anisotropic misfit strains are arbitrarily non-uniform.

나노인덴테이션 해석을 통한 Ag/Cu층에서 발생하는 Misfit 전위의 slip 특성에 대한 연구 (Nanoindentation on the Layered Ag/Cu for Investigating Slip of Misfit Dislocation)

  • 트란딘 롱;유용문;전성식
    • Composites Research
    • /
    • 제24권3호
    • /
    • pp.17-24
    • /
    • 2011
  • Ag/Cu층에서 발생하는 misfit 전위를 분석하기 위하여, EAM기법을 활용한 나노인덴테이션 해석을 수행하였다. N$\'{o}$se-Hoover 서모스텟 조건에 의거하여, 2-5nm 정도의 두께를 갖는 필름층에 구형 인덴터로 압입하였다. 해석결과는 misfit 전위에 대한 상대적인 압입위치가, 4nm이하의 필름에 대하여 영향을 미치는 것으로 나타났다. 전위에 의한 슬립 발생할 때 탄성에너지 변화는 Ag/Cu의 연화의 중요한 변수로 작용하며, 각각의 경우에 대하여 임계필름두께에 대해서도 고찰하였다.

MOCVD방법으로 InP 기판 위에 성장시킨 InAs 박막에서의 부정합 전위 생성 연구 (A Study on Misfit Dislocation Generation in InAs Epilayers Grown on InP Substrates by Metalorganic Chemical-Vapor Deposition)

  • 김좌연;윤의중;박경순
    • Applied Microscopy
    • /
    • 제27권4호
    • /
    • pp.483-488
    • /
    • 1997
  • A misfit dislocation generation in InAs epilayers grown on (001) InP substrates (oriented $2^{\circ}$ off (001) toward the [110] direction) using metalorganic chemical-vapor deposition was studied. The InAs film of 17 nm thickness grown at $405^{\circ}C$ showed the three different arrays of dislocations: a straight orthogonal array to the <110> direction, an array to the >100> direction, and an array tilted by a degree of $5\sim45^{\circ}$ from the [110] direction. All of the dislocations had a/2<101> Burgers vectors inclined $45^{\circ}$ to the interface. Upon annealing at $660^{\circ}C$ the InAs films with 60, 140 and 220 nm thicknesses, most of the misfit dislocations became the Lomer type $(\sim100%)$ oriented exactly along the >110> direction. These misfit dislocation spacings were decreased with increasing the InAs thickness up to 220 nm thickness. This phenomena was interpreted by the relationship between the dislocation interaction energy among parallel misfit dislocations and the opposite remnant InAs epilayer strain energy. The distance between misfit dislocations was measured by transmission electron microscopy.

  • PDF

자유표면을 가진 이원계의 상전이에 대한 분자동역학 연구 (A Molecular Dynamics Study in a Binary System with Free Surface)

  • 한혜원;장현구
    • 한국재료학회지
    • /
    • 제10권8호
    • /
    • pp.581-588
    • /
    • 2000
  • Free surface를 가진 레나트-존스 이원계의 가열, 냉각에 따른 상전이를 molecular dynamics simulation을 이용하여 연구하였다. 용매-용질우너자간의 size misfit과 용질우너자의 농도변화에 따른 상전이 거동을 살펴본 결과 size misfit과 용질원자의 농도가 증가함에 따라 가열시 용융시 낮은 온도에서 쉽게 발생하였고, 냉각시 임계냉각속도가 감소하여 결정화는 어려워졌다.

  • PDF

적합도에 따른 ITI 임플란트 지지 고정성 국소의치의 삼차원 유한요소 분석 (Three Dimensional Finite Element Analysis on ITI Implant Supported Fixed Partial Dentures with Various Fitting Accuracy)

  • 최민호;이일권;김유리;조혜원
    • 구강회복응용과학지
    • /
    • 제22권1호
    • /
    • pp.75-87
    • /
    • 2006
  • The purpose of this study was to investigate the effects of prostheses misfit, cantilever on the stress distribution in the implant components and surrounding bone using three dimensional finite element analysis. Two standard 3-dimensional finite element models were constructed: (1) 3 ITI implant supported, 3-unit fixed partial denture and (2) 3 ITI implant supported, 3-unit fixed partial denture with a distal cantilever. variations of the standard finite element models were made by placing a $100{\mu}m$ or $200{\mu}m$ gap between the fixture, the abutment and the crown on the second premolar and first molar. Total 14 models were constructed. In each model, 244 N of vertical load and 244 N of $30^{\circ}$ oblique load were placed on the distal marginal ridge of the distal molar. von Mises stresses were recorded and compared in the crowns, abutments, crestal compact bones, and trabecular bones. The results were obtained as follows: 1. In the ITI implant system, cement-retained prostheses showed comparatively low stress distributions on all the implant components and fixtures regardless of the misfit sizes under vertical loading. The stresses were increased twice under oblique loading especially in the prostheses with cantilever, but neither showed the effects of misfit size. 2. Under the oblique loading and posterior cantilever, the stresses were highly increased in the crestal bones around ITI implants, but effects of misfit were not shown. Although higher stresses were shown on the apical portion of trabecular bones, the effects by misfit were little and the stresses were increased by the posterior cantilever. 3. When the cement loss happened in the ITI implant supported FPD with misfit, the stresses were increased in the implant componets and supporting structures.

2차원유한요소분석을 이용한 임플란트 보철물의 적합도 분석 (Analysis of Implant Prosthesis using 2-Dimensional Finite Element Method)

  • 권호범;박찬제;이석형
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.341-348
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

2차원 유한요소분석을 이용한 임플란트 보철물의 적합도 분석 (Analysis of Implant Prosthesis Using 2-Dimensional Finite Element Method)

  • 권호범;박찬제;이석형
    • 구강회복응용과학지
    • /
    • 제22권3호
    • /
    • pp.251-260
    • /
    • 2006
  • Accurate fit of the implant prosthesis is important in ensuring long term success of osseointegrated implant. Inaccurate fit of the implant prosthesis may give rise to complications and mechanical failure. To evaluate fite of the implant prosthesis, the development of the methods of analyzing the degree of misfit is important in clinical practice. To analyze the degree of the misfit of implant prosthesis, modal testing was used. A 2-dimensional finite element modal testing was accomplished. Four 2-dimensional finite element models with various levels of misfit of implant prostheses were constructed. Thickness gauges were simulated to make misfit in the implant prostheses. With eigenvalue analysis, the natural frequencies of the models were found in the frequency domain representation of vibration. According to the difference of degree of misfit, natural frequencies of the models were changed.

Atomic Structure Analysis of A ZnO/Pd Interface by Atomic Resolution HVTEM

  • Saito, Hiromitsu;Ichinose, Hideki
    • Applied Microscopy
    • /
    • 제36권spc1호
    • /
    • pp.41-46
    • /
    • 2006
  • Interfacial atomic structure (chemical structure) of a Pd/ZnO hetero junction was investigated by atomic resolution high voltage transmission electron microscopy (ARHVTEM). A misfit dislocation did not work as a stress accommodation mechanism in the ZnO(0001)/Pd (111) interface. But the periodic stress localization occurred in the ZnO($10\bar{1}0$)/(200) interface. The periodicity of the local strain coincided with that of misfit dislocation. Atomic structure image of the ARHVTEM showed that an atomic arrangement across the interface was in the order of O-Zn-Pd. It was shown that mechanical weakness of the ZnO(0001)/Pd(111) interface against cyclic heating is attributable to the absence of the periodic stress localization of the misfit dislocation.

Accuracy of various imaging methods for detecting misfit at the tooth-restoration interface in posterior teeth

  • Francio, Luciano Andrei;Silva, Fernanda Evangelista;Valerio, Claudia Scigliano;Cardoso, Claudia Assuncao e Alves;Jansen, Wellington Correa;Manzi, Flavio Ricardo
    • Imaging Science in Dentistry
    • /
    • 제48권2호
    • /
    • pp.87-96
    • /
    • 2018
  • Purpose: The present study aimed to evaluate which of the following imaging methods best assessed misfit at the tooth-restoration interface: (1) bitewing radiographs, both conventional and digital, performed using a photostimulable phosphor plate (PSP) and a charge-coupled device (CCD) system; (2) panoramic radiographs, both conventional and digital; and (3) cone-beam computed tomography (CBCT). Materials and Methods: Forty healthy human molars with class I cavities were selected and divided into 4 groups according to the restoration that was applied: composite resin, composite resin with liner material to simulate misfit, dental amalgam, and dental amalgam with liner material to simulate misfit. Radiography and tomography were performed using the various imaging methods, and the resulting images were analyzed by 2 calibrated radiologists. The true presence or absence of misfit corresponding to an area of radiolucency in regions subjacent to the esthetic and metal restorations was validated with microscopy. The data were analyzed using a receiver operating characteristic (ROC) curve, and the scores were compared using the Cohen kappa coefficient. Results: For bitewing images, the digital systems (CCD and PSP) showed a higher area under the ROC curve (AUROC) for the evaluation of resin restorations, while the conventional images exhibited a larger AUROC for the evaluation of amalgam restorations. Conventional and digital panoramic radiographs did not yield good results for the evaluation of resin and amalgam restorations (P<.05). CBCT images exhibited good results for resin restorations(P>.05), but showed no discriminatory ability for amalgam restorations(P<.05). Conclusion: Bitewing radiographs (conventional or digital) should be the method of choice when assessing dental restoration misfit.

IV족 천이금속 질화물과 bcc Fe간 계면 에너지의 제일원리 연구 (A First Principles Calculation of the Coherent Interface Energies between Group IV Transition Metal Nitrides and bcc Iron)

  • 정순효;정우상;변지영
    • 한국재료학회지
    • /
    • 제16권8호
    • /
    • pp.473-478
    • /
    • 2006
  • The coherent interface energies and misfit strain energies of Fe/XN (X=Ti, Zr, Hf) systems were calculated by first principles method. The interface energies in Fe/TiN, Fe/ZrN and Fe/HfN systems were 0.343, 0.114, and 0.030 $J/m^2$, respectively. Influence of bond energy was estimated using the discrete lattice plane/nearest neighbor broken bond(DLP/NNBB) model. It was found that the dependence of interface energy on the type of nitride was closely related to changes of the bond energies between Fe, X and N atoms before and after formation of the Fe/XN interfaces. The misfit strain energies in Fe/TiN, Fe/ZrN, and Fe/HfN systems were 0.239, 1.229, and 0.955 eV per 16 atoms(Fe; 8 atoms and XN; 8 atoms). More misfit strain energy was generated as the difference of lattice parameters between the bulk Fe and the bulk XNs increased.