• 제목/요약/키워드: Mirror Surface

검색결과 477건 처리시간 0.025초

무산소동의 초정밀 절삭 특성을 이용한 아노드 및 캐비티의 가공 (Machining of Anode and Cavity applying Ultraprecision Machining Characteristics of OXFC)

  • 원종호;김주환;박순섭;김건희;김상석
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.922-925
    • /
    • 2002
  • Klystron which is micro wave amplifier tube are mainly used in fields of science such as accelerator, nuclear fusion, broadcasting, communication fields, and defense industry fields, tract. The quality of Klystron anode and cavity are determined by form accuracy and roughness of the worked surface. Therefore anode and cavity are restricted the from accuracy strictly and the surface roughness be under Rmax 0.03S. As a work material of anode and cavity, the oxygen-free copper, that is used for optical pares of aerospace and laser mirror is selected. An outside diameter of material is $\Phi$100 mm and an inside diameter is $\Phi$30~33 mm. In this study, to find the optimum ultra precision cuffing condition of oxygen-free copper with diamond turning machine, the surface roughness is examined for various diamond toot nose radius, main spindle speed, fred rate and depth of cut. As a result of experiment, we could machined the anode and cavity with a surface roughness within Ra 3.2 nm, a form accuracy within 0.01 $\mu\textrm{m}$.

  • PDF

EP와 MR Polishing 복합공정에 의한 304 스테인리스강의 경면가공 (Mirrorlike Machining of SUS304 by Combined process of EP and MR Polishing)

  • 김동우;홍광표;조명우;이은상
    • 한국생산제조학회지
    • /
    • 제19권2호
    • /
    • pp.267-274
    • /
    • 2010
  • Recently, the magnetorheological (MR) polishing process has been examined as a new ultra-precision polishing technology for mirror surface generation in many applications, such as aspheric lenses, biochips, micro parts, etc. This method uses MR fluids which contains micro abrasives as a polishing media, and can. It is possible to obtain nano level surface roughness under suitable process conditions, however, required polishing time is highly dependent on the applied pre-polishing methods due to its very small material removal rate. Thus, in this study, a combined polishing method is presented to reduce total polishing time for SUS304. First, the electropolishing (EP) method was applied to obtain fine surface roughness, and the MR polishing was followed. Surface roughness variations were investigated according to the process conditions. As the results of this study, it was possible to reduce total polishing time for SUS304 using the proposed combined polishing method.

Bowl-feed 연마기법에 의한 초연마 반사경 기판의 표면 거칠기 특성 (Surface roughness characteristics of the super-polished)

  • 조민식
    • 한국광학회지
    • /
    • 제11권5호
    • /
    • pp.312-316
    • /
    • 2000
  • Bowl-feed식 연마공정에 의한 초연마 반사경 기판의 표면 거칠기 특성이 전통적인 fresh-feed식 연마공정의 경우와 비교하여 조사하였다. Bowl-feed식 연마기법에 의해 가공된 반사경 기판의 표면 거칠기는 fresh-feed식 연마공정에 비해 약 3배 개선되었으며, 표면 거칠기 RMS값의 경우 $0.5\AA$이하, 최고 $0.3\AA$의 양호한 결과를 얻었다. 또한, 연마된 반사경 기판의 1차원 표면 거칠기 분포도와 표면 거칠기 amplitude spectrum으로부터 fresh-feed 공정에 대한 bowl-feed 연마공정의 기판표면구조 변화상태가 분석되었다.

  • PDF

이동 최소제곱 근사법을 이용한 파면오차 계산 알고리즘 (Wave-Front Error Reconstruction Algorithm Using Moving Least-Squares Approximation)

  • 연정흠;강금실;윤형식
    • 한국광학회지
    • /
    • 제17권4호
    • /
    • pp.359-365
    • /
    • 2006
  • 광학계의 파면오차는 광학계의 성능을 나타내는 주요 지표이며, 광학면의 변형에 의해 발생한다. 광기계의 개발에 있어서 주요 하중조건에서 발생하는 파면오차 양은 중요 규격으로 설정되고 관리되어 진다. 광학면의 변형은 유한요소해석 등의 발달과 더불어 정확한 수준까지 계산할 수 있게 되었다. 유한요소해석 결과로부터 파면오차를 계산하기 위해서는 광학면에서의 변형량을 근사하고 분석해야 한다. 이를 위해 추가적인 격자나 요소망으로 결과를 변화하여 근사하는 방법이 사용되고 있으나, 격자 구성의 번거로움과 변환으로 인한 오차 발생 소지를 가지고 있다. 본 연구에서는 추가적인 격자의 구성없이 절점 정보만으로 효과적인 근사를 할 수 있는 이동 최소제곱 근사법을 사용하여 변형량을 근사하고 파면오차를 계산하는 방법을 제안하였다. 제안된 방법의 효용성을 보이기 위하여 해양탑재체 스캔 미러의 자중에 의한 파면오차를 계산하였고, 기존의 방법과 비교 분석하였다.

Effects of Form Errors of a Micromirror Surface on the Optical System of the TMATM(Thin-film Micromirror ArrayTM) Projector

  • Jo, Yong-Shik;Kim, Byoung-Chang;Kim, Seung-Woo;Hwang, Kyu-Ho
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권1호
    • /
    • pp.98-105
    • /
    • 2000
  • The projectors using liquid crystal display(LCD) have faults such as low optical efficiency, low brightness and even heat generation. To solve these problems reflective-type spatial light modulators based on MEMS (Microelectromechanical Systems) technology have emerged. Digital Micromirror DeviceTM(DMDTM), which was already developed by Texas Instruments Inc., and Thin-film Micromirror ArrayTM(TMATM), which has been recently developed by Daewoo Electronics Co., are the representative examples. The display using TMATM has particularly much higher optical efficiency than other projectors. But the micromirrors manufactured by semiconductor processes have inevitable distortion because of the limitations of the manufacturing processes, so that the distortions of their surfaces have great influence on the optical efficiency of the projector. This study investigated the effects of mirror flatness on the optical performance, including the optical efficiency, of the TMATM projector. That is to say, as a part of the efforts to enhance the performance of the TMATM projector, how much influence the form errors of a micromirror surface exert on the optical efficiency and the modulation of gray scale of the projector were analyzed through a pertinent modeling and simulations.

  • PDF

설진 시스템 개발 및 재현성 평가 (The Development of a Tongue Diagnosis System and the Evaluation of Reproducibility)

  • 전영주;김근호;도준형;유현희;김종열
    • 한국한의학연구원논문집
    • /
    • 제14권3호
    • /
    • pp.97-102
    • /
    • 2008
  • The tongue diagnosis is a diagnostic method in the oriental medicine that uses shape, substance, coating, and movement of the tongue to determine the condition of health and disease characteristics in human. Since this information, however, could be affected by subjective sense and visual information, it is difficult to obtain the objective and reproducible results. This research aims at building a reproducible tongue diagnosis system using color chart that is attached close to the face contact region. The picture of color chart is taken simultaneously with a tongue and applied to color revision. The system, in addition, is focused on providing a clear tongue image through securing a sufficient photographing distance with a surface coating mirror. The lightning part which can suppress the reflection by sputum in maximum is implemented for the objectification and quantification of the tongue diagnosis system. The face contact region is designed for consideration of a testee's convenience. To evaluate the reproducibility of the system, the CVs (coefficient of variance, %) of $L{\ast}$, $a{\ast}$ and $b{\ast}$ of red, green and blue regions in color chart are calculated, respectively. The results of all CVs shows that the tongue diagnosis system is re liable and those consequences contribute to the objectification and quantification of the tongue diagnosis system.

  • PDF

자동차 부품용 무도장 메탈릭 플라스틱 소재 개발 (Development of Paint-free Metallic Plastic Material for Automotive Parts)

  • 최민진;조정민;최영호;최민호;이춘수;성한기;이경실;박기훈;황세종
    • Korean Chemical Engineering Research
    • /
    • 제60권2호
    • /
    • pp.295-299
    • /
    • 2022
  • 본 논문에서는 범퍼 스키드 플레이트 및 아웃사이드미러 하우징 부품에 적용되는 polypropylene (PP)와 acrylonitrile styrene acrylate (ASA) 소재를 활용하여 무도장 메탈릭 소재 구현에 대해 연구하였다. 금속 효과를 극대화하기 위해 알루미늄 입자의 종류, 크기, 함량을 최적화하였고 웰드 라인을 은폐하기 위해 종횡비가 상이한 하이브리드 알루미늄 입자를 사용하였다. 또한 부품 표면에 발생되는 플로우 마크를 개선하기 위해 유동성을 제어하였으며 사출 해석을 수행하였다.

고해상도 표면 측정을 위한 회전 프리즘 정합 간섭계 (Rotational Prism Stitching Interferometer for High-resolution Surface Testing)

  • 송인웅;권우성;김학용;이윤우;이종웅;양호순
    • 한국광학회지
    • /
    • 제34권3호
    • /
    • pp.117-123
    • /
    • 2023
  • 반사경의 광학면이 넓어질수록 높은 공간 주파수 형상이 광학계의 성능에 큰 영향을 주므로, 대형 반사경 성능 평가에서 이를 측정할 수 있어야 한다. 따라서 높은 주파수의 형상을 샘플링할 수 있는 고해상도 형상 측정 시스템이 필요하다. 본 연구에서는 반사경의 고해상도 형상 측정을 위한 회전 프리즘 정합 간섭계(rotational prism stitching interferometer, RPSI)라는 새로운 방법을 제안한다. RPSI는 기존에 사용되고 있는 상용 간섭계에 빔 확장 렌즈, 이송 거울, 회전 프리즘 등을 추가하여 구성되었으며, 간섭계를 움직이지 않고 원통 좌표계를 기준으로 전체 구경을 아우르는 부분 구경 형상들을 측정한다. 측정된 부분 구경들은 최소자승법을 이용한 부분 구경 정합법을 이용하여 정합되며, 빔확장 렌즈 배율의 제곱만큼 높은 샘플링 밀도로 전체 구경 형상 정보를 복원 가능하다. 3배율을 가지는 RPSI를 이용하여 직경 40 mm의 구면 반사경 형상을 측정하였고, 간섭계 단독으로 측정한 전체 구경 형상과 비교 검증하였다. 약 1 nm RMS의 근소한 차이로 유사한 형상을 잘 복원할 수 있었으며, 간섭계 단독으로 사용한 형상 측정 결과보다 렌즈의 배율의 제곱배만큼 향상된 샘플링 밀도로 형상 측정이 가능함을 확인하였다.

PSD를 이용한 광학적 자동 촛점장치 (Optical Autofocus System for Wafer Steppers using PSD as the Position Sensor)

  • 박기수
    • 한국광학회지
    • /
    • 제4권2호
    • /
    • pp.157-161
    • /
    • 1993
  • PSD(Position Sensitive Detector)를 위치센서로 사용하여 광학적 자동촛점 장치를 구성하여 그 특성을 조사하였다. 본 연구는 광 리소그라피 장비인 KrF 엑사이머 레이저 스템퍼를 모델로 개발 하였다. 광원으로 780nm인 반도체 레이저를 사용하였으며, 시준기, 반사경, 렌즈 등을 사용한 광학계를 구성하여 위치신호(position error signal)를 측정 하였으며, 분해능은 $0.03{\mu}m$이었다.

  • PDF

반도체 실리콘재료의 정밀연삭을 위한 공정변수와 연삭후 표면에 형성된 wheel pattern과의 관계 (Surface Wheel Pattern Analysis and Grinding Process Parameters of Silicon)

  • 오한석;박성은;이홍림
    • 한국정밀공학회지
    • /
    • 제19권2호
    • /
    • pp.187-194
    • /
    • 2002
  • For the fine grinding process development of semiconductor monocrystalline silicon, wheel rotational speed, chuck rotational speed, feed rate and hysteresis force were controlled. Magic mirror system was used for grinding wheel pattern analysis. Curvature of wheel pattern was measured by fitting equation. The modeling of surface wheel pattern was related to wheel and chuck rotational speed. The calculated curvature of the model was well matched with the measured curvature. The statistical analysis indicated wheel and chuck rotational speed were significantly effective on.