Performance Analysis for Mirrors of 30 cm Cryogenic Space Infrared Telescope

  • Park, Kwi-Jong;Moon, Bong-Kon;Lee, Dae-Hee;Jeong, Woong-Seob;Nam, Uk-Won;Park, Young-Sik;Pyo, Jeong-Hyun;Han, Won-Yong
    • Journal of Astronomy and Space Sciences
    • /
    • 제29권3호
    • /
    • pp.321-328
    • /
    • 2012
  • We have designed a 30 cm cryogenic space infrared telescope for astronomical observation. The telescope is designed to observe in the wavelength range of 0.5~2.1 ${\mu}m$, when it is cooled down to 77 K. The result of the preliminary design of the support structure and support method of the mirror of a 30 cm cryogenic space infrared telescope is shown in this paper. As a Cassegrain prescription, the optical system of a 30 cm cryogenic space infrared telescope has a focal ratio of f/3.1 with a 300 mm primary mirror (M-1) and 113 mm secondary mirror (M-2). The material of the whole structure including mirrors is aluminum alloy (Al6061-T6). Flexures that can withstand random vibration were designed, and it was validated through opto-mechanical analysis that both primary and secondary mirrors, which are assembled in the support structure, meet the requirement of root mean square wavefront error < ${\lambda}/8$ for all gravity direction. Additionally, when the M-1 and flexures are assembled by bolts, the effect of thermal stress occurring from a stainless steel bolt when cooled and bolt torque on the M-1 was analyzed.

Low voltage Low power OTAs using bulk driven in 0.35㎛ CMOS Process (0.35㎛ CMOS 공정에서 벌크 입력을 사용한 저전압 저전력 OTAs)

  • Kang, Seong-Ki;Jung, Min-Kyun;Han, Dae-Deok;Yang, Min-Jae;Yoon, Eun-Jung;Yu, Chong-Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 한국정보통신학회 2015년도 추계학술대회
    • /
    • pp.451-454
    • /
    • 2015
  • This paper introduces 3 type of OTAs with $0.35-{\mu}m$ standard CMOS technology for Low-Power, Low-Voltage. The first type is a two-stage OTA designed to operate with a 1-V VDD and it has $1.774{\mu}W$ low power consumption. All transistors are operating in strong inversion. It takes Gm-Enhancement techniques to compensate gm, which is lowered by Bulk-Driven technique and has an Wide swing current mirror for low voltage operation and a Class-A output. The second type is a Two-stage OTA designed to operate with a 0.8-V VDD and It has 52nW low power consumption and 112dB high gain. The current mirror uses Composite Transistor binding Gates of two MOSFET to raise Rout which is similar with cascode structure. The third type is a Two-stage OTA designed to operate with a 0.6-V VDD and It has 160nW low power consumption and 72dB high gain. It takes Level Shift technique by Common Gate structure to amplify signals without additional bias voltage at second stage.

  • PDF

Design of an Optical System for a Space Target Detection Camera

  • Zhang, Liu;Zhang, Jiakun;Lei, Jingwen;Xu, Yutong;Lv, Xueying
    • Current Optics and Photonics
    • /
    • 제6권4호
    • /
    • pp.420-429
    • /
    • 2022
  • In this paper, the details and design process of an optical system for space target detection cameras are introduced. The whole system is divided into three structures. The first structure is a short-focus visible light system for rough detection in a large field of view. The field of view is 2°, the effective focal length is 1,125 mm, and the F-number is 3.83. The second structure is a telephoto visible light system for precise detection in a small field of view. The field of view is 1°, the effective focal length is 2,300 mm, and the F-number is 7.67. The third structure is an infrared light detection system. The field of view is 2°, the effective focal length is 390 mm, and the F-number is 1.3. The visible long-focus narrow field of view and visible short-focus wide field of view are switched through a turning mirror. Design results show that the modulation transfer functions of the three structures of the system are close to the diffraction limit. It can further be seen that the short-focus wide-field-of-view distortion is controlled within 0.1%, the long-focus narrow-field-of-view distortion within 0.5%, and the infrared subsystem distortion within 0.2%. The imaging effect is good and the purpose of the design is achieved.

Simulation and Examination for Beam Profile of DFB Laser with an Anti-reflection Coated Mirror (무반사 면을 갖는 DFB 레이저의 빔 분포 시뮬레이션과 검정)

  • Kwon, Kee-Young;Ki, Jang-Geun
    • Journal of Software Assessment and Valuation
    • /
    • 제16권1호
    • /
    • pp.55-63
    • /
    • 2020
  • Lasers for optical broadband communication systems should have excellent frequency selectivity and modal stability. DFB lasers have low lasing frequency shift during high speed current modulation. In this paper, when a refractive index grating and a gain grating are simultaneously present in a DFB laser having a wavelength of 1.55 ㎛, the dielectric film is coated so that reflection does not occur on the right mirror surface, so that ρr=0. For the first mode, which requires a minimum gain at the threshold, the beam distribution of the oscillation mode in the longitudinal direction and the radiated power ratio Pl/Pr were analyzed and compared for the cases of the phase of ρl=π and π/2. If the phase of ρl=π, in order to obtain a low threshold current and high frequency stability, κL should be greater than 8. In the case of the phase of ρl=π/2, for low threshold current, κL is necessary to be 1.0, where the oscillation frequency coincides with the lattice frequency. DFB lasers with an anti-reflection coated mirror have excellent mode selectivity than 1.55um DFB lasers with two mirror facets

Variable Optical Attenuator Incorporating Dual Fiber Collimator and Bi-metal Actuator (이중 광 콜리메터와 바이메탈 엑추에이터를 이용한 가변 광감쇠기)

  • Kim, Kwang Taek;Kim, Duck Bong;Koh, Hanjun
    • Korean Journal of Optics and Photonics
    • /
    • 제29권1호
    • /
    • pp.28-31
    • /
    • 2018
  • In this paper, we have proposed and demonstrated a variable optical attenuator (VOA) incorporating a dual-fiber collimator and a bimetallic actuator. The optical attenuation between input and output single-mode fibers was tuned by tilting the angle of a reflection mirror fixed on the bimetal. The bimetal was heated or cooled by a thermoelectric cooler (TEC) and then moved the reflection mirror, due to bending and unreeling. The desired optical attenuation can be obtained through adjusting the electrical input into the TEC. The fabricated device showed 0.5 dB of insertion loss, 0.2 dB of maximum polarization-dependent loss, and 40 dB of dynamic range. The response time was measured to be about 5 s.

Widely Tunable Wavelength-Selective Reflector Using Polymer Waveguide Double-Ring-Resonator Add/Drop Filter and Loop-back Mirror

  • Lee, Ho;Kim, Gun-Woo;Park, Jun-Oh;Kim, Su-Hyun;Chung, Young-Chul
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.157-161
    • /
    • 2008
  • A wavelength-selective reflector, composed of a double-ring-resonator add/drop filter and a loop-back mirror at the drop port to be used for a hybrid-integrated tunable laser is designed and fabricated. High-index-contrast polymer waveguide is used to realize a compact device as small as $2mm{\times}0.4mm$. The radii of the rings are slightly different from each other to obtain a wide wavelength tuning via a vernier effect. Peak reflectivity is measured to be 52% for TE mode and polarization-dependent wavelength shift is 0.95 nm. The tuning range is measured to be about 42 nm for applied current as small as 46 mA.

A Comprasion of the Activation of Mirror Neurons Induced by Action Observation between Simple and Complex Hand Movement

  • Lee, Mi Young;Kim, Ju Sang
    • The Journal of Korean Physical Therapy
    • /
    • 제31권3호
    • /
    • pp.157-160
    • /
    • 2019
  • Purpose: We compared the activation pattern of the mirror neurons (MN) between two types of hand movement according to action observation using functional MRI. Methods: Twelve right-handed healthy subjects (5 male and 7 female, mean age $21.92{\pm}2.02years$) participated in the experiment. During fMRI scanning, subjects underwent two different stimuli on the screen: 1) video clips showing repeated grasping and releasing of the ball via simple hand movement (SHM), and (2) video clips showing an actor performing a Purdue Pegboard test via complex hand movement (CHM). paired t-test in statistical parametric mapping (SPM) was used to compare the activation differences between the two types of hand movement. Results: CHM as compared with the SHM produced a higher blood oxygen level dependent (BOLD) signal response in the right superior frontal gyrus, left inferior and superior parietal lobules, and lingual gyrus. However, no greater BOLD signal response was found by SHM compared with CHM (FWE corrected, p<0.05). Conclusion: Our findings provided that the activation patterns for observation of SHM and CHM are different. CHM also elicited boarder or stronger activations in the brain, including inferior parietal lobule called the MN region.

Toxic Effects of Waterborne Copper Exposure on the Hematological Parameters and Plasma Components of Mirror Carp Cyprinus carpio nudus (수인성 구리 급성노출에 의한 향어(Cyprinus carpio nudus)의 혈액학적 성상 및 혈장성분의 독성영향)

  • Jo, A-Hyun;Hong, Su-Min;Jeong, Ji-ho;Eun, Ji-Su;Joo, Chang-Hoon;Kim, Jun-Hwan
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • 제54권6호
    • /
    • pp.954-964
    • /
    • 2021
  • Mirror carp Cyprinus carpio nudus (weight 42.0±3.8 g, length 14.3±0.4 cm) were exposed to different concentrations of waterborne copper (0, 100, 200, 400, 800, and 1,600 ㎍ Cu2+·L-1) at 20.3℃ for 96 h. The lethal concentration 50 of waterborne copper was 1,176.45 ㎍ Cu2+·L-1. Among hematological parameters, red blood cell count was significantly decreased, whereas there were no significant changes in the hemoglobin concentration and hematocrit value. Among the inorganic plasma components, calcium was significantly decreased following copper exposure. Conversely, organic plasma components such as glucose and total protein were significantly increased. Similarly, enzymatic components, such as aspartate transaminase, alanine transaminase, and alkaline phosphatase, were also significantly increased. These findings suggest that the copper exposure is detrimental to the survival rates and physiology of C. carpio nudus.

A Study on the Current Measurement Using birefringence Fiber (복굴절 광섬유를 이용한 전류측정에 관한 연구)

  • Jang Nam-Young;Choi Pyung-Suk;Eun Jae-Jeong
    • Journal of the Institute of Convergence Signal Processing
    • /
    • 제6권2호
    • /
    • pp.59-66
    • /
    • 2005
  • Accuracy of current measurement in fiber optic current sensor(FOCS), especially, unidirectional polarimetric fiber optic current sensor(PFOCS) is affected by the environment perturbations such as acoustic vibrations changes to the sensing fiber, and intrinsic perturbations such as the bending fiber that the sensing fiber wound around a current carrying wire. The perturbations affect the birefringence properties of sensing fiber in sensor head and cause false current readings. Thus, using compensation technique, reciprocal PFOCS, for unidirectional PFOCS the perturbations are suppressed. In this paper, we carried out the numerical analysis of performance in reciprocal PFOCS including the degree of polarization error, and false current of environmental and intrinsic perturbations on the sensing fiber. Also, we compared the effect of mirror with the faraday rotation mirror(FRM) in reciprocal PFOCS configuration. And the different optical source's wavelengths, 633nm and 1300nm is used. In the results, at 633nm, using mirror and FRM, the degree of polarization error is calculated to $2.3\%$ and $0.0196\%$, respectively. At $1300{\cal}nm$ using mirror and FRM the degree of polarization error is calculated to $9.97\%$ and $0.0196\%$, respectively. Also, compared with false current, the results is calculated to $9.82{\times}10^{-9}A$ and $1.4{\times}10^{-17}A$, respectively, and show that the reciprocal PFOCS is more robust configuration than unidiretionnal PFOCS for environmental and intrinsic perturbations.

  • PDF

Development Success of the Secondary Mirror Prototype for Giant Magellan Telescope

  • Koh, Ju Heon;Kim, Young-Soo;Jung, Ho June;Jung, Hwa Kyoung;Yang, Ho-Soon;Kim, Ho-Sang;Lee, Kyoung-Don;Cho, Myung;Park, Won Hyun;Ahn, Hyo-Sung;Hwang, Narae;Yuk, In-Soo;Park, Byeong-Gon
    • The Bulletin of The Korean Astronomical Society
    • /
    • 제38권2호
    • /
    • pp.85.1-85.1
    • /
    • 2013
  • GMT(Giant Magellan Telescope)는 25.4m의 주경과 3.2m의 부경으로 이루어진 거대망원경이다. 3.2m의 부경은 빠른 tip-tilt로 망원경을 제어하는 Fast Steering Mirror(FSM)와 적응광학계로 이루어진 Adaptive Secondary Mirror (ASM)로 구분된다. 한국천문연구원은 국내외 협력기관들과 함께 부경 FSM의 시험모델개발을 수행하고 있다. 부경은 1.06m의 반사경 일곱 개로 이루어져 있는데, 한 개의 광축 반사경 주위로 여섯개의 비축 반사경이 둘러싸여서 하나의 3.2m 반사경과 같은 기능을 하고 있다. 비축 비구면 반사경에 대한 시험모델의 반사면을 가공한 결과 표면가공 정밀도가 11.7nm rms의 정밀도를 갖는 반사경을 가공하였다(target : <20nm rms). 또한 test-bed를 제작하여 tip-tilt 정밀도를 제어한 결과 성능요구 조건 값인 0.03arcsec 제어에 성공하였고, 더 나아가 0.01arcsec의 tip-tilt 제어도 가능한 것으로 판단된다.

  • PDF