• Title/Summary/Keyword: Minute volume

Search Result 203, Processing Time 0.024 seconds

Standard Measurement Procedure for Soil Radon Exhalation Rate and Its Uncertainty

  • Seo, Jihye;Nirwono, Muttaqin Margo;Park, Seong Jin;Lee, Sang Hoon
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.29-38
    • /
    • 2018
  • Background: Radon contributing about 42% of annual average dose, mainly comes from soil. In this paper, standard measurement procedures for soil radon exhalation rate are suggested and their measurement uncertainties are analyzed. Materials and Methods: We used accumulation method for estimating surface exhalation rate. The closed-loop measurement system was made up with a RAD7 detector and a surface chamber. Radon activity concentrations in the system were observed as a function of time, with data collection of 5 and 15-minute and the measurement time of 4 hours. Linear and exponential fittings were used to obtain radon exhalation rates from observed data. Standard deviations of measurement uncertainties for two approaches were estimated using usual propagation rules. Results and Discussion: The exhalation rates (E) from linear approach, with 30 minutes measurement time were $44.8-48.6mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.14-2.32atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with relative measurement uncertainty of about 10%. The contributions of fitting parameter A, volume (V) and surface (S) to the estimated measurement uncertainty of E were 59.8%, 30.1% and 10.1%, in average respectively. In exponential fitting, at 3-hour measurement we had E ranged of $51.6-69.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.46-3.30atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with about 15% relative uncertainty. Fitting with 4-hour measurement resulted E about $51.3-68.2mBq{\cdot}m^{-2} {\cdot}s^{-1}$ or $2.45-3.25atom{\cdot}cm^{-2}{\cdot}s^{-1}$ with 10% relative uncertainty. The uncertainty contributions in exponential approach were 75.1%, 13.4%, 8.7%, and 2.9% for total decay constant k, fitting parameter B, V, and S, respectively. Conclusion: In obtaining exhalation rates, the linear approach is easy to apply, but by saturation feature of radon concentrations, the slope tends to decrease away from the expected slope for extended measurement time. For linear approach, measurement time of 1-hour or less was suggested. For exponential approach, the obtained exhalation rates showed similar values for any measurement time, but measurement time of 3-hour or more was suggested for about 10% relative uncertainty.

Risk Factors for Predicting Hypoxia in Adult Patients Undergoing Bronchoscopy under Sedation

  • Choi, Ji Soo;Lee, Eun Hye;Lee, Sang Hoon;Leem, Ah Young;Chung, Kyung Soo;Kim, Song Yee;Jung, Ji Ye;Kang, Young Ae;Park, Moo Suk;Chang, Joon;Kim, Young Sam
    • Tuberculosis and Respiratory Diseases
    • /
    • v.83 no.4
    • /
    • pp.276-282
    • /
    • 2020
  • Background: Flexible bronchoscopy is one of the essential procedures for the diagnosis and treatment of pulmonary diseases. The purpose of this study was to identify the risk factors associated with the occurrence of hypoxia in adults undergoing flexible bronchoscopy under sedation. Methods: We retrospectively analyzed 2,520 patients who underwent flexible bronchoscopy under sedation at our tertiary care university hospital in South Korea January 1, 2013-December 31, 2014. Hypoxia was defined as more than 5%-point reduction in the baseline percutaneous oxygen saturation (SpO2) or SpO2 <90% for >1 minute during the procedure. Results: The mean age was 64.7±13.5, and 565 patients developed hypoxia during the procedure. The mean sedation duration and midazolam dose for sedation were 31.1 minutes and 3.9 mg, respectively. The bivariate analysis showed that older age, a low forced expiratory volume in one second (FEV1), use of endobronchial ultrasound, the duration of sedation, and the midazolam dose were associated with the occurrence of hypoxia during the procedure, while the multivariate analysis found that age >60 (odds ratio [OR], 1.32), a low FEV1 (OR, 0.99), and a longer duration of sedation (>40 minutes; OR, 1.33) were significant risk factors. Conclusion: The findings suggest that patients older than age 60 and those with a low FEV1 tend to develop hypoxia during the bronchoscopy under sedation. Also, longer duration of sedation (>40 minutes) was a significant risk factor for hypoxia.

The Effects of Simultaneous Pulmonary Rehabilitation during Thoracic Radiotherapy in the Treatment of Malignant Diseases

  • Choi, Myeong Geun;Lee, Hyang Yi;Song, Si Yeol;Kim, Su Ssan;Lee, Seung Hak;Kim, Won;Choi, Chang-Min;Lee, Sei Won
    • Tuberculosis and Respiratory Diseases
    • /
    • v.84 no.2
    • /
    • pp.148-158
    • /
    • 2021
  • Background: Radiotherapy is a common treatment option for lung or esophageal cancer, particularly when surgery is not feasible for patients with poor lung function. However, radiotherapy can affect pulmonary function and thereby induce pneumonitis or pneumonia, which can be fatal in patients with respiratory impairment. The purpose of this study is to evaluate if reductions in pulmonary function after radiotherapy can be minimized through simultaneous pulmonary rehabilitation (PR). Methods: In this matched case control study, we retrospectively analyzed patients who had undergone radiotherapy for thoracic malignant disease between January 2018 and June 2019. We analyzed results from pulmonary function tests and 6-minute walking tests (6MWT) conducted within the six months before and after radiotherapy treatment. Results: In total, results from 144 patients were analyzed, with 11 of the patients receiving PR and radiotherapy simultaneously. Of the 133 patients in the control group, 33 were matched with 11 patients in the PR group. Changes in forced expiratory volume in one second (FEV1) and FEV1/forced vital capacity were significantly different between the PR group and the matched control group (240 mL vs. -10 mL, p=0.017 and 5.5% vs. 1.0%, p=0.038, respectively). The median distance of 6MWT in the PR group also increased significantly, from 407.5 m to 493.0 m after radiotherapy (p=0.017). Conclusion: Simultaneous PR improved pulmonary function, particularly in measures of FEV1, and exercise capacity for patients with lung or esophageal cancer even after radiotherapy treatment. These findings may provide an important base of knowledge for further large population studies with long-term follow-up analysis in the identification of the PR's effects during thoracic radiotherapy.

Differences in Temporary Threshold Shift and Recovery Patterns Depending on Sound Type and Pressure (소리의 종류와 크기에 따른 일과성 청력 역치 상승과 회복의 차이)

  • Lee, Chae Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.4
    • /
    • pp.387-393
    • /
    • 2020
  • Objective: This study aimed to investigate the differences in temporary threshold shift (TTS) and recovery patterns according to different types of sound and volume. Methods: TTS and recovery patterns were assessed for eight students after 30-minute exposure to both 70.0 dB and 90.0 dB of factory noise (noise) as well as music. TTS was measured before exposure and two minutes post exposure, and recovery patterns were evaluated every 10 minutes for one hour. The subjects performed activities of daily life and sleeping times as usual but taking drugs or drinking alcohol were prohibited. The experiment was repeated three times with an interval of at least 16 hours. ANOVA and T-test were carried out using SPSS 19.0 for Windows. Results: The hearing threshold of all subjects before exposure was less than 30 dB at all frequencies. Mean TTSs of 70 dB noise and 90 dB noise exposure were 0.14 and 4.48 dB (p<0.001). Meanwhile, the difference in music was insignificant (-0.63 dB and 0.55 dB, p=0.063). A significance in the difference was also found between the mean TTS of music and noise exposure, more obviously at 90.0 dB (p<0.001) than at 70 dB (p=0.232). The TTS differences were found frequency-wise in terms of sound type. Mean TTS by frequency was higher at 4,000 and 6,000 Hz than at other frequencies, and higher in noise than music at the same sound pressure. The TTS difference in each frequency between both sound types was significant at 90 dB (p<0.001). Subjects mostly recovered from TTS in one hour after exposure, but not with 90 dB-noise exposure. Conclusion: TTS and recovery patterns were different depending on the sound type. When exposed to factory noise, TTS was greater and recovery time was longer compared to music at the same sound pressure. These results suggested that the difference in cognitive processes and psychological factors according to the type of sound causes a change in TTS and recovery.

Phosphodiesterase-5 Inhibitor Attenuates Anxious Phenotypes and Movement Disorder Induced by Mild Ischemic Stroke in Rats

  • Yu, Yeon Hee;Kim, Seong-Wook;Kang, Juhyeon;Song, Yejin;Im, yHyuna;Kim, Seo Jeong;Yoo, Dae Young;Lee, Man-Ryul;Park, Dae-Kyoon;Oh, Jae Sang;Kim, Duk-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.5
    • /
    • pp.665-679
    • /
    • 2022
  • Objective : Patients with mild ischemic stroke experience various sequela and residual symptoms, such as anxious behavior and deficits in movement. Few approaches have been proved to be effective and safe therapeutic approaches for patients with mild ischemic stroke by acute stroke. Sildenafil (SIL), a phosphodiesterase-5 inhibitor (PDE5i), is a known remedy for neurodegenerative disorders and vascular dementia through its angiogenesis and neurogenesis effects. In this study, we investigated the efficacy of PDE5i in the emotional and behavioral abnormalities in rats with mild ischemic stroke. Methods : We divided the rats into four groups as follows (n=20, respectively) : group 1, naïve; group 2, middle cerebral artery occlusion (MCAo30); group 3, MCAo30+SIL-pre; and group 4, MCAo30+SIL-post. In the case of drug administration groups, single dose of PDE5i (sildenafil citrate, 20 mg/kg) was given at 30-minute before and after reperfusion of MCAo in rats. After surgery, we investigated and confirmed the therapeutic effect of sildenafil on histology, immunofluorescence, behavioral assays and neural oscillations. Results : Sildenafil alleviated a neuronal loss and reduced the infarction volume. And results of behavior task and immunofluorescence shown possibility that anti-inflammation process and improve motor deficits sildenafil treatment after mild ischemic stroke. Furthermore, sildenafil treatment attenuated the alteration of theta-frequency rhythm in the CA1 region of the hippocampus, a known neural oscillatory marker for anxiety disorder in rodents, induced by mild ischemic stroke. Conclusion : PDE5i as effective therapeutic agents for anxiety and movement disorders and provide robust preclinical evidence to support the development and use of PDE5i for the treatment of mild ischemic stroke residual disorders.

Methodology for Estimating Highway Traffic Performance Based on Origin/Destination Traffic Volume (기종점통행량(O/D) 기반의 고속도로 통행실적 산정 방법론 연구)

  • Howon Lee;Jungyeol Hong;Yoonhyuk Choi
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.23 no.2
    • /
    • pp.119-131
    • /
    • 2024
  • Understanding accurate traffic performance is crucial for ensuring efficient highway operation and providing a sustainable mobility environment. On the other hand, an immediate and precise estimation of highway traffic performance faces challenges because of infrastructure and technological constraints, data processing complexities, and limitations in using integrated big data. This paper introduces a framework for estimating traffic performance by analyzing real-time data sourced from toll collection systems and dedicated short-range communications used on highways. In particular, this study addresses the data errors arising from segmented information in data, influencing the individual travel trajectories of vehicles and establishing a more reliable Origin-Destination (OD) framework. The study revealed the necessity of trip linkage for accurate estimations when consecutive segments of individual vehicle travel within the OD occur within a 20-minute window. By linking these trip ODs, the daily average highway traffic performance for South Korea was estimated to be248,624 thousand vehicle kilometers per day. This value shows an increase of approximately 458 thousand vehicle kilometers per day compared to the 248,166 thousand vehicle kilometers per day reported in the highway operations manual. This outcome highlights the potential for supplementing previously omitted traffic performance data through the methodology proposed in this study.

Pulmonary Function, Functional Capacity, Respiratory, and Locomotor Muscle Strength after Severe to Critically Ill COVID-19: A Long-Term Study

  • Thanunya Ngamsutham;Warawut Chaiwong;Sauwaluk Dacha;Patraporn Sitilertpisan;Chaicharn Pothirat;Pilaiporn Duangjit;Athavudh Deesomchok;Chalerm Liwsrisakun;Chaiwat Bumroongkit;Theerakorn Theerakittikul;Atikun Limsukon;Konlawij Trongtrakul;Nutchanok Niyatiwatchanchai;Pattraporn Tajarernmuang
    • Tuberculosis and Respiratory Diseases
    • /
    • v.87 no.4
    • /
    • pp.532-542
    • /
    • 2024
  • Background: The sequelae of post-coronavirus disease 2019 (COVID-19) pneumonia on lung function, exercise capacity, and quality of life were observed in both short-term and long-term. However, the study about the respiratory and locomotor muscle strength in severe and critically ill COVID-19 survivors are still limited. Therefore, we aimed to examine long-term pulmonary function, functional capacities, and respiratory and locomotor body muscle strength in severe to critically ill post-COVID-19 survivors. Methods: A prospective observational study was conducted in 22 post-COVID-19 pneumonia and healthy adults. Clinical characteristics during admission, pulmonary function, functional capacity, respiratory muscles, and locomotor muscles strength were examined at 1, 3, and 6 months after discharge from the hospital. Results: The generalized linear mixed model showed that percent predicted of forced expiratory volume in the 1 second (%FEV1), percent predicted of forced vital capacity (%FVC), maximum inspiratory pressure (MIP), handgrip strength, 6-minute walk distance, and five times sit to stand (5TSTS) were significantly lower in post-COVID-19 pneumonia patients than in healthy subjects during the follow-up period. The percent predicted of maximal voluntary ventilation (%MVV), and locomotor muscle strength were not different between the two groups throughout the follow-up period. Among post-COVID-19 pneumonia patients, %FEV1, %FVC, %MVV, 5TSTS, locomotor muscle strength significantly improved at three months compared to baseline at 1 month. Conclusion: Pulmonary function, functional capacity, respiratory, and locomotor muscle strength of survivors from COVID-19 were impaired and recovery was observed after three to six months. These emphasized the need to evaluate the long-term consequences of COVID-19.

The Effect of Surfactant Therapy for Acute Lung Injury Induced by Intratracheal Endotoxin Instillation in Rats (기관내 내독소 투여로 유발된 흰쥐의 급성폐손상에서 surfactant의 치료효과)

  • Kang, Yun-Jung;Park, Yong-Bum;Jee, Hyun-Suk;Choi, Jae-Chol;Kim, Jae-Yeol;Park, In-Won;Choi, Byoung-Whui
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.4
    • /
    • pp.487-499
    • /
    • 2000
  • Background : Acute lung injury is an hypoxic respiratory failure resulting from damage to the alveolar-capillary membrane, which can be developed by a variety of systemic inflammatory diseases. In this study the therapeutic effects of intra-tracheal pulmonary surfactant instillation was evaluated in the intratracheal endotoxin induced acute lung injury model of a rat. Methods : Twenty Sprague-Dawley rats were divided into 4 groups, and normal saline (2 ml/kg, for group 1) or LPS (5 mg/kg, for group 2, 3, and 4) was instilled into the trachea respectively. Either normal saline (2 ml/kg, for group 1 & 2, 30 min later) or bovine surfactant (15 mg/kg, 30 min later for group 3, 5 hr later for group 5) was instilled into the trachea. The therapeutic effect of intratracheal surfactant therapy was evaluated with one chamber body plethysmography (respiratory frequency, tidal volume and enhanced pause), ABGA, BAL fluid analysis (cell count with differential, protein concentration) and pathologic examination of the lung. Results : Intratracheal endotoxin instillation increased the respiration rate decreased the tidal volume and int creased the Penh in all group of rats. Intratracheal instillation of surfactant decreased Penh, increased arterial oxygen tension, decreased protein concentration of BAL fluid and decreased lung inflammation at both times of administration (30 minute and 5 hour after endotoxin instillation). Conclusion : Intratracheal instillation of surfactant can be a beneficial therapeutic modality as discovered in the acute lung injury model of rats induced by intratracheal LPS intillation. It deserves to be evaluated for treatment of human acute lung injury.

  • PDF

Analysis of Greenhouse Thermal Environment by Model Simulation (시뮬레이션 모형에 의한 온실의 열환경 분석)

  • 서원명;윤용철
    • Journal of Bio-Environment Control
    • /
    • v.5 no.2
    • /
    • pp.215-235
    • /
    • 1996
  • The thermal analysis by mathematical model simulation makes it possible to reasonably predict heating and/or cooling requirements of certain greenhouses located under various geographical and climatic environment. It is another advantages of model simulation technique to be able to make it possible to select appropriate heating system, to set up energy utilization strategy, to schedule seasonal crop pattern, as well as to determine new greenhouse ranges. In this study, the control pattern for greenhouse microclimate is categorized as cooling and heating. Dynamic model was adopted to simulate heating requirements and/or energy conservation effectiveness such as energy saving by night-time thermal curtain, estimation of Heating Degree-Hours(HDH), long time prediction of greenhouse thermal behavior, etc. On the other hand, the cooling effects of ventilation, shading, and pad ||||&|||| fan system were partly analyzed by static model. By the experimental work with small size model greenhouse of 1.2m$\times$2.4m, it was found that cooling the greenhouse by spraying cold water directly on greenhouse cover surface or by recirculating cold water through heat exchangers would be effective in greenhouse summer cooling. The mathematical model developed for greenhouse model simulation is highly applicable because it can reflects various climatic factors like temperature, humidity, beam and diffuse solar radiation, wind velocity, etc. This model was closely verified by various weather data obtained through long period greenhouse experiment. Most of the materials relating with greenhouse heating or cooling components were obtained from model greenhouse simulated mathematically by using typical year(1987) data of Jinju Gyeongnam. But some of the materials relating with greenhouse cooling was obtained by performing model experiments which include analyzing cooling effect of water sprayed directly on greenhouse roof surface. The results are summarized as follows : 1. The heating requirements of model greenhouse were highly related with the minimum temperature set for given greenhouse. The setting temperature at night-time is much more influential on heating energy requirement than that at day-time. Therefore It is highly recommended that night- time setting temperature should be carefully determined and controlled. 2. The HDH data obtained by conventional method were estimated on the basis of considerably long term average weather temperature together with the standard base temperature(usually 18.3$^{\circ}C$). This kind of data can merely be used as a relative comparison criteria about heating load, but is not applicable in the calculation of greenhouse heating requirements because of the limited consideration of climatic factors and inappropriate base temperature. By comparing the HDM data with the results of simulation, it is found that the heating system design by HDH data will probably overshoot the actual heating requirement. 3. The energy saving effect of night-time thermal curtain as well as estimated heating requirement is found to be sensitively related with weather condition: Thermal curtain adopted for simulation showed high effectiveness in energy saving which amounts to more than 50% of annual heating requirement. 4. The ventilation performances doting warm seasons are mainly influenced by air exchange rate even though there are some variations depending on greenhouse structural difference, weather and cropping conditions. For air exchanges above 1 volume per minute, the reduction rate of temperature rise on both types of considered greenhouse becomes modest with the additional increase of ventilation capacity. Therefore the desirable ventilation capacity is assumed to be 1 air change per minute, which is the recommended ventilation rate in common greenhouse. 5. In glass covered greenhouse with full production, under clear weather of 50% RH, and continuous 1 air change per minute, the temperature drop in 50% shaded greenhouse and pad & fan systemed greenhouse is 2.6$^{\circ}C$ and.6.1$^{\circ}C$ respectively. The temperature in control greenhouse under continuous air change at this time was 36.6$^{\circ}C$ which was 5.3$^{\circ}C$ above ambient temperature. As a result the greenhouse temperature can be maintained 3$^{\circ}C$ below ambient temperature. But when RH is 80%, it was impossible to drop greenhouse temperature below ambient temperature because possible temperature reduction by pad ||||&|||| fan system at this time is not more than 2.4$^{\circ}C$. 6. During 3 months of hot summer season if the greenhouse is assumed to be cooled only when greenhouse temperature rise above 27$^{\circ}C$, the relationship between RH of ambient air and greenhouse temperature drop($\Delta$T) was formulated as follows : $\Delta$T= -0.077RH+7.7 7. Time dependent cooling effects performed by operation of each or combination of ventilation, 50% shading, pad & fan of 80% efficiency, were continuously predicted for one typical summer day long. When the greenhouse was cooled only by 1 air change per minute, greenhouse air temperature was 5$^{\circ}C$ above outdoor temperature. Either method alone can not drop greenhouse air temperature below outdoor temperature even under the fully cropped situations. But when both systems were operated together, greenhouse air temperature can be controlled to about 2.0-2.3$^{\circ}C$ below ambient temperature. 8. When the cool water of 6.5-8.5$^{\circ}C$ was sprayed on greenhouse roof surface with the water flow rate of 1.3 liter/min per unit greenhouse floor area, greenhouse air temperature could be dropped down to 16.5-18.$0^{\circ}C$, whlch is about 1$0^{\circ}C$ below the ambient temperature of 26.5-28.$0^{\circ}C$ at that time. The most important thing in cooling greenhouse air effectively with water spray may be obtaining plenty of cool water source like ground water itself or cold water produced by heat-pump. Future work is focused on not only analyzing the feasibility of heat pump operation but also finding the relationships between greenhouse air temperature(T$_{g}$ ), spraying water temperature(T$_{w}$ ), water flow rate(Q), and ambient temperature(T$_{o}$).

  • PDF

The Effect of Using Two Different Type of Dose Calibrators on In Vivo Standard Uptake Value of FDG PET (FDG 사용 시 Dose Calibrator에 따른 SUV에 미치는 영향)

  • Park, Young-Jae;Bang, Seong-Ae;Lee, Seung-Min;Kim, Sang-Un;Ko, Gil-Man;Lee, Kyung-Jae;Lee, In-Won
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.115-121
    • /
    • 2010
  • Purpose: The purpose of this study is to measure F-18 FDG with two different types of dose calibrator measuring radionuclide and radioactivity and investigate the effect of F-18 FDG on SUV (Standard Uptake Value) in human body. Materials and Methods: Two different dose calibrators used in this study are CRC-15 Dual PET (Capintec) and CRC-15R (Capintec). Inject 1 mL, 2 mL, 3 mL of F-18 FDG into three 2 mL syringes, respectively, and measure initial radioactivity from each dose calibrator. Then measure and record radioactivity at 30 minute interval for 270 minutes. According to the initial radioactivity, linearity between decay factor driven from radioactive decay formula and the values measured by dose calibrator have been analyzed by simple linear regression. Fine linear regression line optimizing values measured with CRC-15 through regression analysis on the basis of the volume of which the measured value is close to the most ideal one in CRC-15 Dual PET. Create ROI on lung, liver, and region part of 50 persons who has taken PET/CT test, applying values from linear regression equation, and find SUV. We have also performed paired t-test to examine statistically significant difference in the radioactivity measured with CRC-15 Dual PET, CRC-15R and its SUV. Results: Regression analysis of radioactivity measured with CRC-15 Dual PET and CRC-15R shows results as follows: in the case 1 mL, the r statistic representing correlation was 0.9999 and linear regression equation was y=1.0345x+0.2601; in 2 mL case, r=0.9999, linear regression equation y=1.0226x+0.1669; in 3 mL case, r=0.9999, linear regression equation y=1.0094x+0.1577. Based on the linear regression equation from each volume, t-test results show significant difference in SUV of ROI in lung, liver, region part in all three case. P-values in each case are as follows: in 1 mL case, lung, liver and region (p<0.0001); in 2 mL case, lung (p<0.002), liver and region (p<0.0001); in 3 mL case, lung (p<0.044), liver and region (p<0.0001). Conclusion: Radioactivity measured with CRC-15 Dual PET, CRC-15R, dose calibrator for F-18 FDG test, do not show difference correlation, while these values infer that SUV has significant differences in the aspect of uptake in human body. Therefore, it is necessary to consider the difference of SUV in human body when using these dose calibrator.

  • PDF