• Title/Summary/Keyword: Minute Dust

Search Result 20, Processing Time 0.025 seconds

A Study on Changes in Indoor Air Pollution by Educational Activities -Centering on Newly-Established Elementary Schools- (교육활동에 따른 실내오염도 변화에 관한 연구 -신설 초등학교를 중심으로-)

  • Jeon, Seok-Jin
    • The Journal of Sustainable Design and Educational Environment Research
    • /
    • v.6 no.2
    • /
    • pp.66-90
    • /
    • 2007
  • The purpose of this study is to measure and analyze primary causes of indoor air pollution, including carbon dioxide, minute dust, and total volatile organic compounds, for each room before the beginning of a class through the time of discharge after the end of the class in general classrooms, computer rooms, and science rooms of three newly-established schools that opened in 2006, examine properties of indoor air environment in each room by educational activities at school, and determine effective management schemes; the results of this study can be summarized as follows: 1) As for implications for each item found in the mean for each place, since minute dust (PM10) was more likely to occur in time slots full of students' activities, such as a traveling class and a recess, than in the middle of a class and could be expected fully, it is necessary to make a scheme for cleaning in order to reduce minute dust within a room, for example, by usually using a vacuum cleaner indoors. 2) While carbon dioxide was expected to vary with the differences in the amount of breath between higher-graders and lower-graders in a general classroom but showed insignificant difference by grades, showing differences in pollution by four times at a maximum according to the opening of a window as expected, it is necessary to implement artificial or natural ventilation and take a positive measure, for example, by presenting a concrete ventilation scheme, in order to improve indoor air pollution at a room practice. 3) Total volatile organic compounds were found to exceed the standard by more than twice in general classrooms, science rooms, and computer rooms of the schools because of building materials, furnitures including desks and chairs, panels and boards for environment beautification, and items which could be detected even from students' clothes; while a field directly-reading tool was used, obtaining high reliability for the results, it is necessary to apply an analytical method based on process test separately for actual correct measurement if a significantly great amount of total volatile organic compounds appear as compared with other schools due to measuring expenses and consecutive measurements. 4) Since formaldehyde (HCHO) was generally found to exceed the standard in general classrooms, science rooms, and computer rooms, it is necessary to establish and operate a ventilator during a class in a computer room which requires airtightness and a science room in which an organic compound should be used for a class.

  • PDF

Chemical Transformation of Individual Asian Dust Particles Estimated by the Novel Double Detector System of Micro-PIXE

  • Ma, Chang-Jin
    • Asian Journal of Atmospheric Environment
    • /
    • v.4 no.2
    • /
    • pp.106-114
    • /
    • 2010
  • By the application of novel double detector system of micro-PIXE that can detect light elements (Z<14), we made an attempt to provide a thorough discussion on the aging processes of Asian dust (hereafter called "AD") particle by reaction with sea-slat. The elemental spectra and maps obtained from the microbeam radiation of micro-PIXE to individual AD particles were useful for fractionating AD particles into both internally and externally mixed particles. A spatial distribution of elements in a minute domain of single particle obtained by scanning the microbeam irradiation enabled us not only to estimate the chemical mixing state of individual AD particles but also to presume their aging processes in both ambient air and cloud. By calculating the normalized micro-PIXE net count of elements, it was possible to classify individual AD particles into three distinct groups (i.e., (1) Aging type 1: AD particle coated by the gaseous Cl evaporated by the reaction between artificial acids and sea salt; (2) Aging type 2: AD particle mixed with sea salt but no additional reaction with artificial acids; and (3) Non-aged type) A relatively high transformation rate (63.3-75.9%) was shown in large particles (greater than $5.1\;{\mu}m$ in diameter).

Radioactive Nuclide Identification of a Fall-Out Sample in Korea (放射能 落塵의 核種檢出의 一例)

  • Kim, Chong-Kuk
    • Journal of the Korean Chemical Society
    • /
    • v.6 no.2
    • /
    • pp.155-157
    • /
    • 1962
  • A tiny dust found at the balcony of the Institute indicated about 8,0000 counts per minute by T.G.C.-2 Geiger-Muller tube (1.8mg/$cm^2$ window-thickness) at the distance of 2cm from the window. The main fission fragments, as identified by the present analysis, are 12.5day Ba-140 and 33.1 day Ce-141. The gamma energies were determined using $2"{\times}2"$ NaI(Tl) scintillation detector connected to RCL-256 channel pulse heigt analyzer. The beta energies were evaluated by Feather plot.

  • PDF

A Study on the Reduction of Environmental Civil Appeals for In-site Crusher Facilities (현장파쇄시설의 환경민원 발생 저감방안 연구)

  • Jung, Jong-Suk;Lee, Jae-Sung;Lee, Kyoung-Hee;Jun, Myoung-Hoon;Bae, Kee-Sun
    • Korean Journal of Construction Engineering and Management
    • /
    • v.9 no.5
    • /
    • pp.176-185
    • /
    • 2008
  • Recently, the construction wastes rapidly increase because of redevelopment, the development of new urbanization of large housing development, the expansion of social infrastructure. With increase of the construction noise, vibration, and dust caused by these developments, environmental conflicts and civil appeals increase. Moreover, the Government will reduce environmental level in the near future. Therefore, it will be expected to increase environmental conflicts and civil appels related to construction noise, vibration, and dust. To minimize environmental conflicts and civil appels, this study suggest the plan of prevention of environmental confliction and civil appeal by analyzing and measuring vibration, noise level, and dust of in-site crusher facilities at large and development district.

A study on the air pollutant emission trends in Gwangju (광주시 대기오염물질 배출량 변화추이에 관한 연구)

  • Seo, Gwang-Yeob;Shin, Dae-Yewn
    • Journal of environmental and Sanitary engineering
    • /
    • v.24 no.4
    • /
    • pp.1-26
    • /
    • 2009
  • We conclude the following with air pollution data measured from city measurement net administered and managed in Gwangju for the last 7 years from January in 2001 to December in 2007. In addition, some major statistics governed by Gwangju city and data administered by Gwangju as national official statistics obtained by estimating the amount of national air pollutant emission from National Institute of Environmental Research were used. The results are as follows ; 1. The distribution by main managements of air emission factory is the following ; Gwangju City Hall(67.8%) > Gwangsan District Office(13.6%) > Buk District Office(9.8%) > Seo District Office(5.5%) > Nam District Office(3.0%) > Dong District Office(0.3%) and the distribution by districts of air emission factory ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%). That by types(Year 2004~2007 average) is also following ; Type 5(45.2%) > Type 4(40.7%) > Type 3(8.6%) > Type 2(3.2%) > Type 1(2.2%) and the most of them are small size of factory, Type 4 and 5. 2. The distribution by districts of the number of car registrations is the following ; Buk District(32.8%) > Gwangsan District(22.4%) > Seo District(21.8%) > Nam District(14.9%) > Dong District(8.1%) and the distribution by use of car fuel in 2001 ; Gasoline(56.3%) > Diesel(30.3%) > LPG(13.4%) > etc.(0.2%). In 2007, there was no ranking change ; Gasoline(47.8%) > Diesel(35.6%) > LPG(16.2%) >etc.(0.4%). The number of gasoline cars increased slightly, but that of diesel and LPG cars increased remarkably. 3. The distribution by items of the amount of air pollutant emission in Gwangju is the following; CO(36.7%) > NOx(32.7%) > VOC(26.7%) > SOx(2.3%) > PM-10(1.5%). The amount of CO and NOx, which are generally generated from cars, is very large percentage among them. 4. The distribution by mean of air pollutant emission(SOx, NOx, CO, VOC, PM-10) of each county for 5 years(2001~2005) is the following ; Buk District(31.0%) > Gwangsan District(28.2%) > Seo District(20.4%) > Nam District(12.5%) > Dong District(7.9%). The amount of air pollutant emission in Buk District, which has the most population, car registrations, and air pollutant emission businesses, was the highest. On the other hand, that of air pollutant emission in Dong District, which has the least population, car registrations, and air pollutant emission businesses, was the least. 5. The average rates of SOx for 5 years(2001~2005) in Gwangju is the following ; Non industrial combustion(59.5%) > Combustion in manufacturing industry(20.4%) > Road transportation(11.4%) > Non-road transportation(3.8%) > Waste disposal(3.7%) > Production process(1.1%). And the distribution of average amount of SOx emission of each county is shown as Gwangsan District(33.3%) > Buk District(28.0%) > Seo District(19.3%) > Nam District(10.2%) > Dong District(9.1%). 6. The distribution of the amount of NOx emission in Gwangju is shown as Road transportation(59.1%) > Non-road transportation(18.9%) > Non industrial combustion(13.3%) > Combustion in manufacturing industry(6.9%) > Waste disposal(1.6%) > Production process(0.1%). And the distribution of the amount of NOx emission from each county is the following ; Buk District(30.7%) > Gwangsan District(28.8%) > Seo District(20.5%) > Nam District(12.2%) > Dong District(7.8%). 7. The distribution of the amount of carbon monoxide emission in Gwangju is shown as Road transportation(82.0%) > Non industrial combustion(10.6%) > Non-road transportation(5.4%) > Combustion in manufacturing industry(1.7%) > Waste disposal(0.3%). And the distribution of the amount of carbon monoxide emission from each county is the following ; Buk District(33.0%) > Seo District(22.3%) > Gwangsan District(21.3%) > Nam District(14.3%) > Dong District(9.1%). 8. The distribution of the amount of Volatile Organic Compound emission in Gwangju is shown as Solvent utilization(69.5%) > Road transportation(19.8%) > Energy storage & transport(4.4%) > Non-road transportation(2.8%) > Waste disposal(2.4%) > Non industrial combustion(0.5%) > Production process(0.4%) > Combustion in manufacturing industry(0.3%). And the distribution of the amount of Volatile Organic Compound emission from each county is the following ; Gwangsan District(36.8%) > Buk District(28.7%) > Seo District(17.8%) > Nam District(10.4%) > Dong District(6.3%). 9. The distribution of the amount of minute dust emission in Gwangju is shown as Road transportation(76.7%) > Non-road transportation(16.3%) > Non industrial combustion(6.1%) > Combustion in manufacturing industry(0.7%) > Waste disposal(0.2%) > Production process(0.1%). And the distribution of the amount of minute dust emission from each county is the following ; Buk District(32.8%) > Gwangsan District(26.0%) > Seo District(19.5%) > Nam District(13.2%) > Dong District(8.5%). 10. According to the major source of emission of each items, that of oxides of sulfur is Non industrial combustion, heating of residence, business and agriculture and stockbreeding. And that of NOx, carbon monoxide, minute dust is Road transportation, emission of cars and two-wheeled vehicles. Also, that of VOC is Solvent utilization emission facilities due to Solvent utilization. 11. The concentration of sulfurous acid gas has been 0.004ppm since 2001 and there has not been no concentration change year by year. It is considered that the use of sulfurous acid gas is now reaching to the stabilization stage. This is found by the facts that the use of fuel is steadily changing from solid or liquid fuel to low sulfur liquid fuel containing very little amount of sulfur element or gas, so that nearly no change in concentration has been shown regularly. 12. Concerning changes of the concentration of throughout time, the concentration of NO has been shown relatively higher than that of $NO_2$ between 6AM~1PM and the concentration of $NO_2$ higher during the other time. The concentration of NOx(NO, $NO_2$) has been relatively high during weekday evenings. This result shows that there is correlation between the concentration of NOx and car traffics as we can see the Road transportation which accounts for 59.1% among the amount of NOx emission. 13. 49.1~61.2% of PM-10 shows PM-2.5 concerning the relationship between PM-10 and PM-2.5 and PM-2.5 among dust accounts for 45.4%~44.5% of PM-10 during March and April which is the lowest rates. This proves that particles of yellow sand that are bigger than the size $2.5\;{\mu}m$ are sent more than those that are smaller from China. This result shows that particles smaller than $2.5\;{\mu}m$ among dust exist much during July~August and December~January and 76.7% of minute dust is proved to be road transportation in Gwangju.

Small-scale structures in the dust cloud associated with 17P/Holmes outburst

  • Ham, Ji-Beom;Ishiguro, Masateru;Kuroda, Daisuke;Fukushima, Hideo;Watanabe, Jun-Ichi
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.35 no.1
    • /
    • pp.92-92
    • /
    • 2010
  • A short-period comet, 17P/Holmes, is one of the most outstanding comets because of the outburs in 2007. It orbits the sun at the distance between 2.1AU and 5.2 AU with the orbital period of 6.9 year. On 2007 October 23, its brightness was suddenly increased by about a million times from 17 mag to 2.5 mag. We made observations of 17P/Holmes soon after the outburst on October 25, 27 and 28, using a 105cm telescope at the Ishigakijima Astronomical observatory, Japan. We took the images with V, R and I-band filters simultaneously. Total exposure times are 15 (October 25), 69 (October 27), and 37 (October 28) minute in each filter. The composite images provide good signal to noise ratio and help us to recognize faint structures embedded in the dust cloud. We examined a sequence of images using a digital filter that enhances the small-scale structures. As the result of the data analysis, we confirm (1) the radial expanded structure coming out from the nucleus of comet, and (2) dozens of blobs that moved radially away from the nucleus. In this presentation, we introduce the observations and the data reductions, and consider the origins of these fine structure.

  • PDF

Seasonal Dust Concentration and Characteristics of Windowless Broiler Building (무창 육계사의 계절별 먼지 농도와 특성 연구)

  • Choi H. C.;Yeon G. Y.;Song J. I.;Kang H. S.;Kwon D. J.;Yoo Y. H.;Barroga A. J.;Yang C. B.;Chun S. S.;Kim Y. K.
    • Journal of Animal Environmental Science
    • /
    • v.11 no.3
    • /
    • pp.197-206
    • /
    • 2005
  • This study was carried out to investigate the concentration and characteristics of dust originating from windowless broiler building in each season. 12.0m width and 46m tenth with side wall height of 3.0m was investigated and capacity was 12,800 birds at a stock density of 23.2 birds per square meter. Dust concentrations in terms of total suspended particles (TSP), and particulate matter of sizes $10{\mu}m(PM10),\;2.5{\mu}m (PM2.5),\;and\;1{\mu}m(PM1)$ were measured at 30-minute intervals. On the basis of broiler age, the average dust concentration in summer in TSP as follows: 1,229 904.5 558.8 and $1,053{\mu}g/m^3$ on the broilers' first to fourth week of age, respectively. But during winter, the average dust concentration showed an increasing pattern, as follows: 465.4, 1,401, 4,497, 5,097 and $6,873{\mu}g/m^3$ on the broilers' first to fifth week of age, respectively. The maximum dust concentration of $11,132{\mu}g/m^3$ was observed on the fifth week. On a daily basis, the maximum dust concentration during summer was detected in early morning, and the minimum in the afternoon. The aerial dust particle size of $0.05\~0.35{\mu}m$ was the highest in number. But on volume basis, particle size of 16~99 un had the largest percentage in the broiler house. Crude protein of the dust $(42.8\~65.2\%)$, on dry matter basis, was higher than that $(20.5\~24.5\%)$ fed to the broilers. Heavy metal concentration of the dust also had high levels compared with that of the feed.

  • PDF

A preliminary study of Standardization Plan on Underground Air filtration Facility (지하역사 공기여과장치 표준화방안 사전연구)

  • Bae, Sung-Joon;Hwang, Sun-Ho;Shin, Chang-Hun
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.919-929
    • /
    • 2009
  • 2008, Seoulmetro transports an average of 3,952,000 passengers every day with a 0.8% increase of the daily ridership compared to last year.(Korean Economics '09.01.21) Seoul subway systems ridden by a considerable number of Seoul citizens place their top priority on swiftness, safety and clean underground air quality so as to meet the customer satisfaction. One of the most important problems is to eliminate minute dust(PM10) among the pollutants such as the gas attributable to air pollution and floating particulate matter defined by the ordinance of the Ministry of Environment. Seoulmetro install and operate many kinds of air filtration facilities, however we've launched a research on "Standardization Plan on Underground Air Filtration Facility" for the installation and improvement of optimum standardized air filtration system. As a preliminary study, we're going to consider ventilation system and air filter to supply filtered metropolitan outdoor air aimed at ensuring clean underground environment.

  • PDF

Study on Wet Electric Precipitation with Electrospray for Removal of PM1.0 in Exhaust Gas (배가스 내 PM1.0 미세먼지 제거를 위한 정전분무 습식 전기집진기에 대한 연구)

  • Cho, Yeonjoo;Lim, Hyunjeong;Kim, Soyeon;Choi, Sangmi;Jeong, Min Kyu;Kim, Minsung
    • Plant Journal
    • /
    • v.16 no.1
    • /
    • pp.34-37
    • /
    • 2020
  • The need to improve the performance of the dust collector by increasing the fine dust pollution in Korea is eminent. In this study, electrostatic spray wet electrostatic precipitator is used to remove Particulate Matter (PM). In order to enter the Cone-jet mode, which is the most stable spray mode among the various modes of electrostatic spraying, an appropriate voltage-flow condition must be satisfied, and a voltage-flow interval enabling this can be expressed as Stability Island. The voltage at which the conduit mode starts in the Stability Island section is referred to as the electrostatic spray minimum voltage (Onset Voltage). However, the conventional electrostatic spray is uses a very low flowrate, at most few millilitres per minute. The use of much higher flowrates has introduced different patterns of electrospray modes. In this study, the different spray modes will be studied in detail.

Development and Assessment of Real-Time Quality Control Algorithm for PM10 Data Observed by Continuous Ambient Particulate Monitor (부유분진측정기(PM10) 관측 자료 실시간 품질관리 알고리즘 개발 및 평가)

  • Kim, Sunyoung;Lee, Hee Choon;Ryoo, Sang-Boom
    • Atmosphere
    • /
    • v.26 no.4
    • /
    • pp.541-551
    • /
    • 2016
  • A real-time quality control algorithm for $PM_{10}$ concentration measured by Continuous Ambient Particulate Monitor (FH62C14, Thermo Fisher Scientific Inc.) has been developed. The quality control algorithm for $PM_{10}$ data consists of five main procedures. The first step is valid value check. The values should be within the acceptable range limit. Upper ($5,000{\mu}g\;m^{-3}$) and lower ($0{\mu}g\;m^{-3}$) values of instrument detectable limit have to be eliminated as being unrealistic. The second step is valid error check. Whenever unusual condition occurs, the instrument will save error code. Value having an error code is eliminated. The third step is persistence check. This step checks on a minimum required variability of data during a certain period. If the $PM_{10}$ data do not vary over the past 60 minutes by more than the specific limit ($0{\mu}g\;m^{-3}$) then the current 5-minute value fails the check. The fourth step is time continuity check, which is checked to eliminate gross outlier. The last step is spike check. The spikes in the time series are checked. The outlier detection is based on the double-difference time series, using the median. Flags indicating normal and abnormal are added to the raw data after quality control procedure. The quality control algorithm is applied to $PM_{10}$ data for Asian dust and non-Asian dust case at Seoul site and dataset for the period 2013~2014 at 26 sites in Korea.