• Title/Summary/Keyword: Miniplates

Search Result 39, Processing Time 0.027 seconds

COMPLICATIONS ASSOCIATED WITH OPEN REDUCTION OF MANDIBULAR FRACTURES (관혈적 정복술로 치료한 하악골 골절에서의 합병증)

  • Park, Young-Ah;Sohn, Woo-Ill;Chang, Ic-Jun;Song, Jae-Chul;Chin, Byung-Rho
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.27 no.5
    • /
    • pp.474-480
    • /
    • 2001
  • Purpose: The aim of this study was to evaluate the complications of open reduction and internal fixation of mandibular fracture with miniplates. Patients and Methods: A total of 134 patients who presented with 196 fractures were analyzed retrospectively. Complications were evaluated for factors such as age, the site of fracture, the severity of fracture, delayed operation, preoperative wound contamination, the site and disposition of teeth in the fracture line and midfacial fractures. Statistical analysis was used to compare complications to risk factors. Results: Of the 134 patients, 20 patients had some form of postoperative complications and complication rate was 14.9%. These complications included infection, plate fracture, malocclusion, wound dehiscence, nerve injury and nonunion. There was a significant correlation between complication rate and the severity of fracture, preoperative wound contamination and the site of the fracture and disposition of teeth(p<0.05). Conclusion: The occurrence of postoperative complications in the treatment of mandibular fractures was related to the severity of fracture, preoperative wound contamination and the site of the fracture and disposition of teeth.

  • PDF

Safe and Effective Reduction Malarplasty (안전하고 효과적인 광대축소술)

  • Kang, Young Ho
    • The Journal of the Korean dental association
    • /
    • v.58 no.2
    • /
    • pp.103-113
    • /
    • 2020
  • Background: Reduction malarplasty is one of the most popular facial contouring surgeries in east Asia for making patients' faces smaller. Currently in Korea, reduction malarplasty surgeries are performed mostly at plastic surgery clinics, but few cases are done at oral and maxillofacial surgery clinics. The reason might be because of post-operative complications after reduction malarplasty, such as undercorrection, overcorrection, asymmetry, cheek drooping, malunion, pain and noise. Those complications should be uneasy to be handled by oral and maxillofacial surgeons, however, they can be prevented by knowing the effective and safe reduction malarplasty techniques. Therefore, in this article the author as an oral and maxillofacial surgeon, would like to suggest safe and effective surgical methods for reduction malarplasty customized for Korean patients. Method: L- shape osteotomy of zygomatic body was performed with intraoral approach via vestibular incision, and the zygomatic arch was osteotomized with extraoral approach via sideburn incision. Then zygomatic complex was separated and rotated mesio-superiorly without removal of a bony strip and fixed with miniplates and microplates without making a bony gap. Conclusion: Surgical results were favorable and satisfied by the patients without cheek drooping, malunion, undercorrection and asymmetry.

  • PDF

Osteotomy and iliac bone graft for the treatment of malunion caused by failed mandibular fracture reduction

  • Hwang, Kun;Ma, Sung Hwan
    • Archives of Craniofacial Surgery
    • /
    • v.21 no.6
    • /
    • pp.384-386
    • /
    • 2020
  • This report describes osteotomy and iliac bone graft for malunion caused by failed mandibular fracture reduction. A 27-year-old man was referred 3 months after a motor vehicle accident. At another hospital, two operations had been performed for symphyseal fracture using two resorbable plates. Malocclusion was noted, and panoramic radiography and computed tomography revealed a misaligned dental arch, with a 9.37-mm gap between the central and the lateral incisor of the left mandible. A wafer was made from the patient's dental model, and a maxillary arch bar was applied. Through a lower gingivolabial incision, osteotomy was performed between the malunited symphyseal fracture segments. Both segments were reduced to their original position using the wafer and fixed with titanium miniplates via intermaxillary fixation (IMF). The intersegmental gap was filled with cancellous bone from the iliac crest. The gingival defect was covered with a mucosal transposition flap from the gingivolabial sulcus. IMF and the wafer were maintained for 5 and 9 weeks, respectively. At postoperative week 13, the screws were removed from the mandible and satisfactory occlusion was noted. His mouth opening improved from 2.5 to 3 finger breadths (40 mm). This case demonstrates the need for sufficient IMF when using resorbable plates.

The Clinical Study of Maxillofacial Bone Fracture (안면골 골절에 관한 임상적 연구)

  • Cho, Byoung-Ouck;Lee, Yong-Chan;Nam, Jong-Hun;Kim, Tae-Young;Koh, Back-Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.11 no.1
    • /
    • pp.32-40
    • /
    • 1989
  • This study is based on 247 patients(348 cases) with facial bone fracture who were admitted to the department of oral and maxillofacial surgery, Kangnam sacred heart Hospital during the period of Jan. 1983 through sep. 1988. The patients with mandible fracture were analysed with the following items such as complications with treatment method undertaken : Bicortical osteosynthesis vs Monocortical osteosynthesis, advantages and Disadvantages. The results obtained are as follows : 1) The most common age groups for the facial bone fracture were 20 years 2) The ratio of Men to women was 5 : 1 3) The most frequent location of facial bone fractures was the Mandible(76.7%), Maxillae(10.6%), Zygoma(9.5%), Nasal bone(3.2%) 4) The ratio of Mandible to Maxillae was 7.2 : 1 5) In mandible fractures, the most frequent fracture site was Symphysis(48.7%) 6) In maxilla fractures, the most frequent case was Le fort III fracture(51.4%), followed by Le fort I fracture(29.7%), Le fort II fracture(18.9%) 7) The main contributing causes of facial bone fractures were Traffic Accident(37.7%), Fight(31.6%), Accident(27.5%) 8) In open reduction methods of mandible fracture, the frequency of postop, malocclusion was 15% in interosseous wiring, 7% in Bicortical osteosynthesis, 3% in Monocortical osteosynthesis. The miniplates show advantages over other forms of fixation, in that they are malleable and easy to insert, they achieve rigid fixation and stability.

  • PDF

CLINICAL AND RADIOLOGICAL COMPARISON BETWEEN TITANIUM AND BIODEGRADABLE MINIPLATE MONOCORTICAL OSTEOSYNTHESIS IN MANDIBULAR ANGLE FRACTURES (Monocortical Osteosynthesis 이론에 따른 하악골 우각부 골절 수술시 Titanium miniplate와 Biodegradable miniplate의 임상적, 방사선학적 비교 연구)

  • Choi, Eun-Joo;Nam, Woong;Jung, Young-Soo;Kim, Ki-Ho;Kim, Hyung-Jun
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.32 no.3
    • /
    • pp.222-225
    • /
    • 2006
  • The treatment objective of mandibular fracture is a return to normal function. According to Champy, a rigid fixation of mandibular angle fracture is performed by using 4 or 6 holes titanium miniplates on the external oblique ridge of mandible. However, the limitations of metal plate such as hypersensitivity, interference with the cranio-facial growth of growing child, secondary bone resorption around the plate, foreign body reaction, declination of primary callus formation, and bone atrophy due to the lack of normal stress reaction of the bone have been reported. Recently, biodegradable miniplate has been introduced and used as an alternative to the metal plate despite its lower strength than that of the titanium plate and the side effect caused by the resorption in the body. In this study, 61 patients diagnosed as mandibular angle fracture and treated from Jan. 1998 to Dec. 2004 in our department have been reviewed. Metal plate fixation was used in 50 patients and biodegradable plate fixation in 11 patients on the external oblique ridge around the fractured mandibular angle according to the principle of monocortical osteosynthesis by Champy. We compared the incidence of side effects and the degree of bony union at the mandibular inferior border in two different fixation methods. In conclusion, we have found that one miniplate regardless of matter could provide enough strength to grasp bony fragments of the tension site and compress the inferior border of mandible without any complications.

TREATMENT OF CONDYLE FRACTURE WITH RESORBABLE SCREW (흡수성 스크류를 이용한 하악과두 골절의 치료)

  • Yeo, In-Bum;Min, Seung-Ki;Oh, Sung-Hwan;Kwan, Kyung-Hwan;Choi, Sang-Moon;Park, Sang-Kyu
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.28 no.6
    • /
    • pp.559-564
    • /
    • 2006
  • According to the development of operation technique and biologic materials, oromaxillofacial surgery department have used many kinds of metal and biologic materials in ORIF and plastic surgery. In maxillofacial fracture, ORIF with metal plate and screw have short healing period and good prognosis. But ORIF with metal materials have many complications as maxillofacial abnormal growth, screw loosening, bone malunion. And metal materials have not used in infection site. The purpose of this study is to evaluate the clinical value of 10 condylar fracture patients operated with absorbable screw at Wonkwang university. Ten patients(8 males, 2 female, mean aged 28) who had mandibular condyle process fracture treated with PLLA implants(poly-l-lactide) was recalled for follow-up clinical and radiologic examination for 10 years. Mouth opening recorvered to more than 35mm and occlusion was stable in all patients. All fractured mandibular condyles showed anatomic good reduction and long-term stability with the use of resorbable miniplates and screw. Bone healing was satisfactory in all patients, and there was no evidence of abnormal resorption of condylar process.

Treatment of extensive comminuted mandibular fracture between both mandibular angles with bilateral condylar fractures using a reconstruction plate: a case report

  • Lee, Kwonwoo;Yoon, Kyuho;Park, Kwan-Soo;Cheong, Jeongkwon;Shin, Jaemyung;Bae, Jungho;Ko, Inchan;Park, Hyungkoo
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.40 no.3
    • /
    • pp.135-139
    • /
    • 2014
  • This following case report describes the open reduction, internal fixation and the reconstruction of an extensive comminuted mandibular fracture with bilateral condylar fractures in a 19-year-old male patient with an intellectual disability and autistic disorder. He suffered fall trauma, resulting in shattered bony fragments of the alveolus and mandibular body between both mandibular rami, the fracture of both condyles and the avulsion or dislocation of every posterior tooth of the mandible. The patient underwent open reduction and internal fixation between both mandibular rami using a reconstruction plate, open reduction and internal fixation of the shattered fragments using miniplates and screws, and the closed reduction of the bilateral condylar fractures.

The Utility of a Three-Dimensional Approach with T-Shaped Osteotomy in Osseous Genioplasty

  • Jegal, Jung Jae;Kang, Seok Joo;Kim, Jin Woo;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • v.40 no.4
    • /
    • pp.433-439
    • /
    • 2013
  • Background Facial beauty depends on the form, proportion, and position of various units of the face. In terms of the frontal view and facial profile, the chin is the most prominent aesthetic element of the lower third of the face. Many methods have been implemented to obtain good proportions of the lower face. In this study, we applied the T-shaped genioplasty method to correcting chin deformities. Methods All of the procedures in 9 cases were performed under general anesthesia. For genioplasty, a horizontal cutting line and 1 or 2 vertical cutting lines were drawn 5 mm below the mental foramen. Osteotomed bone segments of the chin were used for horizontal widening using bone grafts or for horizontal shortening. Likewise, they were used as bone grafts for vertical lengthening or vertical shortening. The bone segments were approximated in the midline and held in place using miniplates. Results The postoperative appearance of the 9 cases showed that the lower third of the face had been naturally changed. At the same time, vertical lengthening or shortening, and horizontal widening or shortening could be implemented during the operation. Satisfactory results were obtained based on reviews of the patients' preoperative and postoperative photographs. The patients were also satisfied with the outcomes. Conclusions Using T-shaped genioplasty, we efficiently adjusted the shape and position of the chin to obtain good proportions of the lower face and change its contour to obtain an aesthetically appealing oval face in accordance with East Asians' aesthetic preferences.

Easy Molding Technique of Methylmethacrylate Implant Using Plaster and Rapid Prototyping Model in Cranioplasty (두개골 성형술에서 석고와 신속조형모델을 이용한 간단한 Methylmethacrylate 삽입물 제작법)

  • Park, Ki Rin;Kim, Yong-Ha;Kim, Tae Gon;Lee, Jun Ho;Ha, Ju Ho
    • Archives of Craniofacial Surgery
    • /
    • v.13 no.2
    • /
    • pp.125-129
    • /
    • 2012
  • Purpose: Methylmethacrylate is the most commonly used alloplastic material in cranioplasty. However during the polymerization of methylmethacrylate, a significant exothermic reaction takes place. This reaction may result in thermal injury to the brain tissue and other soft tissues. Also it is difficult to make three-dimensional methylmethacrylate implant that is perfectly matched to the defect during the operation time. We report on the molding technique of methylmethacrylate implant using plaster mold and the rapid prototyping model in cranioplasty. Methods: A 44-year-old male was referred to the department for severe frontal hollowness. He was involved in an automobile accident resulting in large frontal bone defect with irregular margin. The preformed patient-specific methylmethacrylate implant was made using plaster mold and the rapid prototyping model before the operative day. The methylmethacrylate implant was placed in the frontal defect and rigidly fixed with miniplates and screws on the operative day. Results: The operation was performed in an hour. In the 6 months follow-up period, there were no complications. Patient was satisfied with the results of cranioplasty. Conclusion: Safe cranioplasty was performed with the preformed patient-specific methylmethacrylate implant using plaster mold and the rapid prototyping model. The result of this method was satisfactory, aesthetically and functionally.

Forehead Reconstruction with Hydroxyapatite Cement(MimixTM) and the Check Framework (Hydroxyapatite Cement(MimixTM)와 격자틀을 이용한 전두부 재건술)

  • Cho, Hyun Woo;Park, Beyoung Yun
    • Archives of Plastic Surgery
    • /
    • v.35 no.2
    • /
    • pp.219-222
    • /
    • 2008
  • Purpose: The purpose of this study is to develop hydroxyapatite cement simplified procedures for reconstruction of craniofacial deformities. Due to its expense and characteristics of quick hardening time, it may be inappropriate for forehead reconstruction or augmentation. Therefore we hear by introduce a more precise, easy and cheap method. The authors report forehead reconstruction with hydroxyapatite cement for a patient who suffered from craniofacial deformity. Methods: Case report and literature review. Results: A 35 year old man came to us with forehead and temporal area depression. He had a history of brain operations due to traumatic epidural hematoma. A physical exam showed an evidence of right side forehead weakness sign. Authors made RP model of his skull and applied check framework with Kirschner's wires for measuring accurate volume and contour on the depressed right side forehead area on the RP model. After complete exposure of defect area by bicoronary insicion, absorbable plate which applied on skull area was removed. Using three Kirschner's wires, authors made check framework on the right forehead lively and fixed with 2-hole miniplates on the boundary of the defect. After checking asymmetry, hydroxyapatite was applied on check shape framework just above Kirschner's wire. After removing Kirschner's wire, we corrected minimal unbalance and contour with bur. Conclusion: Check framework with Kirschner's wire was very convenient and cost saving methods for forehead reconstruction with hydroxyapatite cement.