• 제목/요약/키워드: Minimum electric loss

검색결과 23건 처리시간 0.02초

특성 손실 평가를 통한 하이브리드 자동차 동력전달장치의 빠른 설계 최적화 (Computationally Effective Optimization of Hybrid Vehicle Powertrain Design Using Characteristic Loss Evaluation)

  • 박세호;안창선
    • 한국자동차공학회논문집
    • /
    • 제23권6호
    • /
    • pp.591-600
    • /
    • 2015
  • The efficiency of a powertrain system of hybrid vehicle is highly dependent on the design and control of the hybrid powertrain system. In other words, the optimal design of the powertrain systems is coupled with optimal control of the powertrain system. Therefore, the solution of an optimal design problem for hybrid vehicles is computationally and timely very expensive. For example, dynamic programming, which is a recursive optimization method, is usually used to evaluate the best fuel economy of certain hybrid vehicle design, and, thus, the evaluation takes tens of minutes to several hours. This research aims to accelerate the speed of efficiency evaluation of hybrid vehicles. We suggest a mathematical treat and a methodological treat to reduce the computational load. The mathematical treat is that the dynamics of system is discretized with sparse sampling time without loss of energy balance. The methodological treat is that the efficiency of the hybrid vehicle is inferred by characteristic loss evaluation that is computationally inexpensive. With the suggested methodology, evaluating a design candidate of hybrid powertrain system is taken few minutes, which was taken several hours when dynamic programming is used.

Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

끝이 둥근 슬롯의 분극률에 대한 다항 근사식을 이용한 Ku-Band용 도파관 십자형 방향성 결합기 제작 (Implementation of a Waveguide Cross Guide directional Coupler for Ku-Band using Polynomial Approximations for the Polarizabilities of the Rounded End Slot)

  • 유경완;이재현;박광량;김재명
    • 전자공학회논문지A
    • /
    • 제31A권8호
    • /
    • pp.7-15
    • /
    • 1994
  • In this paper, the directional coupler for Ku-band, which is designed is of the crossguide type with a coupling value of about 3-dB. The apertures chosen for this design are crosses. We used polynomial approximations of rounded end slot to obtain the electric and magnetic polarizability of crossed-slot and compared the results with Cohn's experimental results. The optimized dimensions and positions of the cross aperture are obtained by a trial-and-error reiteration of the program. This paper presents the measurement results for the designed coupler. The very flat coupling shows a total variation of only 29.80$\pm$0.04dB for the design frequency ranges of 12.25GHz-12.75GHz. The measured minimum directivity is 25dB. The aperture attenuation for the finite diaphragm thickness is about 2dB pr 0.5mm, which is in agreement with the theoretical value. The transmission loss and input return loss at center frequency are 0.0564dB and 48.16dB respectively. We obtained the measured minimum directivity of the coupler. Whose apertures are both circles is better than that containing holes in the performance of directivity.

  • PDF

Research on Line Overload Emergency Control Strategy Based on the Source-Load Synergy Coefficient

  • Ma, Jing;Kang, Wenbo;Thorp, James S.
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권3호
    • /
    • pp.1079-1088
    • /
    • 2018
  • A line overload emergency control strategy based on the source-load synergy coefficient is proposed in this paper. First, the definition of the source-load synergy coefficient is introduced. When line overload is detected, the source-load branch synergy coefficient and source-load distribution synergy coefficient are calculated according to the real-time operation mode of the system. Second, the generator tripping and load shedding control node set is determined according to the source-load branch synergy coefficient. And then, according to the line overload condition, the control quantity of each control node is determined using the Double Fitness Particle Swarm Optimization (DFPSO), with minimum system economic loss as the objective function. Thus load shedding for the overloaded line could be realized. On this basis, in order to guarantee continuous and reliable power supply, on the condition that no new line overload is caused, some of the untripped generators are selected according to the source-load distribution synergy coefficient to increase power output. Thus power supply could be restored to some of the shedded loads, and the economic loss caused by emergency control could be minimized. Simulation tests on the IEEE 10-machine 39-bus system verify the effectiveness and feasibility of the proposed strategy.

Cr+Fe 첨가시 PAN-PZT계 세라믹의 전기적 특성에 미치는 영향 (The effect on the electric characteristics of PAN-PZT ceramics dopped with Cr+Fe)

  • 신혜경;김현철;허석현;김진섭;배선기
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 추계학술대회 논문집
    • /
    • pp.251-254
    • /
    • 2000
  • This paper was to measure the structure, electric characteristics of 0.05Pb($(Al_{0.5}Nb_{0.5})$) - 0.95Pb$(Zr_{0.52}Ti_{0.48})O_3$ ceramics dopped with Cr+Fe. The results of this paper were gotten such as follows; The dielectric constants were decreased with Cr+Fe. The dielectric loss was minimum value of 1.008[%], dopped with Cr+Fe O.9[wt%] at 1200[$^{\circ}C$], In case of sintering at 1150[$^{\circ}C$], electromechanical factodkp) was maximum value of kp 42.73[%], at Cr+Fe 0.9[wt%]. The mechanical quality factor(Qm) was maximum value at Cr+Fe 1.2 [wt%], Also, in case of dopped with Cr+Fe, it make a improvement in temperature coefficient of resonant frequency at 0.3[wt%], 1150[$^{\circ}C$].

  • PDF

Evaluation of slip coefficient of slip critical joints with high strength bolts

  • Nah, Hwan-Seon;Lee, Hyeon-Ju;Kim, Kang-Seok;Kim, Woo-Bum
    • Structural Engineering and Mechanics
    • /
    • 제32권4호
    • /
    • pp.477-488
    • /
    • 2009
  • A slip critical joint has various values to adopt the proper slip coefficient in various conditions of faying surfaces in the following codes: AISC, AIJ and Eurocode 3. However, the Korean Building Code still regulates the unique slip coefficient, 0.45, regardless of the diverse faying conditions. In this study, the slip resistance test, including five kinds of surface treatments were conducted to obtain the proper slip coefficients available to steel plate KS SM490A. The faying surfaces were comprised of a clean mill, rust, red lead paint, zinc primer, and shot blast treatment. The candidates for high strength bolts were torque-shear bolts, torque-shear bolts with zinc coating, and ASTM A490 bolts. Based on the test results, the specimens with a shot blasted surface and rusted surface exhibited $k_s$, 0.61, and 0.5, respectively. It is recommended that the specimens with zinc primer exhibit $k_s{\geq}0.40$. The clean mill treated surface had prominently lower values, 0.27. For red lead painted treatment, the thickness of the coating affects the determinant of slip coefficient, so it is necessary to establish a minimum $k_s$ of 0.2, with a coating thickness of 65 ${\mu}m$. During 1,000 hours of relaxation, the uncoated surfaces exhibited the loss of clamping force behind 3%, while the coated surfaces within a certain limited thickness exhibited the loss of clamping within a range of 4.71% and 8.37%.

음향방출을 이용한 발전용 밸브 누설 진단 현장 적용 연구 (In-Situ Application Study on the Power Plant Valve Leak Diagnosis Using Acoustic Emission Technology)

  • 이상국
    • 비파괴검사학회지
    • /
    • 제28권4호
    • /
    • pp.315-322
    • /
    • 2008
  • 발전소 밸브는 장시간 동안 고온고압하의 기혹한 조건으로 운전됨에 따라 밸브 시트(seat)면의 이물질 삽입, 시트의 균열, 스템(stem) 패킹(parking) 또는 용접부위 결함 및 피로균열 둥에 의해 누설손상이 발생하고 있다. 이러한 밸브 내부누설 상태를 정밀하게 진단하고 평가하기 위해서는 음향방출기술의 적용이 필요하며, 본 논문은 현장적용이 가능한 연구를 수행하고 그 결과를 소개하고자 한다. 또한 실제 발전소에서 운전되는 다양한 밸브 조건을 토대로 실험실 실험에 의해 주변잡음, 밸브누설시의 음향레벨 및 스펙트럼 특성을 분석하고, 발전소 현장실험 결과와의 비교분석을 통하여, 밸브 누설상태에 따른 주변잡음, 음향신호 및 측정 가능한 최소 누설검출량 등의 평가방법에 대해 고찰하였다. 실험실 실험 및 현장적용 연구결과로부터 밸브누설 여부를 포함한 상태 평가와 최소 측정가능 누설검출량 평가가 가능하였으며, 향후 본 연구는 발전설비 안전운전과 밸브누설로 인한 에너지 손실 예방에 크게 기여할 것으로 기대된다.

방사상 배전계통의 손실감소 및 전압보상을 위한 커패시터 최적 배치 및 운용 (Optimal Capacitor Placement and Operation for Loss reduction and Improvement of Voltage Profile in Radial Distribution Systems)

  • 김태균;백영기;김규호;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 D
    • /
    • pp.1009-1011
    • /
    • 1997
  • This paper presents an optimization method which determines locations and size of capacitors simultaneously while minimizing power losses and improving voltage profile in radial distribution systems. Especially, the cost function associated with capacitor placement is considered as step function due to banks of standard discrete capacities. Genetic algorithms(GA) are used to obtain efficiently the solution of the cost function associated with capacitors which is non-continuous and non-differentiable function. The strings in GA consist of the node number index and size of capacitors to be installed. The length mutation operator, which is able to change the length of strings in each generation, is used. The proposed method which determines locations and size of capacitors simultaneously can reduce power losses and improve' voltage profile with capacitors of minimum size. Its efficiency is proved through the application in radial distribution systems.

  • PDF

한국형 틸팅열차의 틸팅 판토그래프 동특성 측정시스템 개발 (Development of measuring system of dynamic characteristics for tilting pantograph on the Korean Tilting Train)

  • 목진용;김석원;김영국;김기환
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.692-697
    • /
    • 2007
  • The current collection system, pantograph, is one of the important subsystems in electric train system, because of it's fatal function and role of supplying power to the train system. Generally, the function of current collection system is evaluated by loss of contact rate between pantograph and contact wire in catenary by measuring arcs, or by statistical method of evaluating minimum mean contact force. The Korean Tiling Train(TTX) has been manufactured by KRRI and Korean domestic companies and is preparing the trial running test of itself. In this paper, we introduce our successful achievement, measuring system and applied methods of dynamic characteristics for the tilting pantograph, developed of by our own technology.

  • PDF

(1+1) Evolution Strategy를 이용한 유도전동기의 최적 설계 (High-Efficiency Light-Weight Motor Design Technique for Electric Vehicle Using Evolution Strategy)

  • 김민규;이철균;박정태;이향범;정현교;한송엽
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.9-11
    • /
    • 1995
  • In this paper, tile squirrel case induction motors required multi-objective function are designed. As the objective function of the optimization program, we select the linear combination of loss and mass of motors by using weighting factors. Optimization process is performed by using the evolution strategy (ES). ES is the algorithm that can find the global minimum. To verify validity of the proposed method, a sample design is tried.

  • PDF