• Title/Summary/Keyword: Minimum detectable concentration

Search Result 48, Processing Time 0.024 seconds

Optimization of Acquisition Time of Beta-Gamma Coincidence Counting System for Radioxenon Measurement (방사성제논 탐지를 위한 베타-감마 동시 계측시스템의 측정시간 최적화)

  • Byun, Jong-In;Park, Hong-Mo;Choi, Hee-Yeoul;Song, Myeong-Han;Yun, Ju-Yong
    • Journal of Radiation Protection and Research
    • /
    • v.40 no.3
    • /
    • pp.181-186
    • /
    • 2015
  • Measurement of xenon radioisotopes from nuclear fission is a key element for monitoring underground nuclear weapon tests. $^{131m}Xe$, $^{133}Xe$, $^{133}mXe$ and $^{135}Xe$ in the air can be detected via low background systems such as a beta-gamma coincidence counting system. Radioxenon monitoring is performed through air sampling, xenon extraction, measurement and spectrum analysis. The minimum detectable concentration of $^{135}Xe$ can be significantly variable depending on the sampling time, extraction time and data acquisition time due to its short half-life. In order to optimize the acquisition time with respect to certain experimental parameters such as sampling and xenon extraction, theoretical approach and experiment using SAUNA system were performed to determine the time to minimize the minimum detectable concentration, which the results were discussed.

Overestimation of Radioactivity Concentration of Difficult-To-Measure Radionuclides in Scaling Factor Methodology

  • Park, Junghwan;Kim, Tae-Hyeong;Lee, Jeongmook;Kim, Junhyuck;Kim, Jong-Yun;Lim, Sang Ho
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.19 no.3
    • /
    • pp.367-386
    • /
    • 2021
  • The overestimation and underestimation of the radioactivity concentration of difficult-to-measure radionuclides can occur during the implementation of the scaling factor (SF) method because of the uncertainties associated with sampling, radiochemical analysis, and application of SFs. Strict regulations ensure that the SF method as an indirect method does not underestimate the radioactivity of nuclear wastes; however, there are no clear regulatory guidelines regarding the overestimation. This has been leading to the misuse of the SF methodology by stakeholders such as waste disposal licensees and regulatory bodies. Previous studies have reported instances of overestimation in statistical implementation of the SF methodology. The analysis of the two most popular linear models of the SF methodology showed that severe overestimation may occur and radioactivity concentration data must be dealt with care. Since one major source of overestimation is the use of minimum detectable activity (MDA) values as true activity values, a comparative study of instrumental techniques that could reduce the MDAs was also conducted. Thermal ionization mass spectrometry was recommended as a suitable candidate for the trace level analysis of long-lived beta-emitters such as iodine-129. Additionally, the current status of the United States and Korea was reviewed from the perspective of overestimation.

Minimum Detectable Radioactivity Concentration of Atmospheric Particulate Measurement System for Nuclear Test Monitoring (핵활동 감시를 위한 대기 입자 측정시스템의 최소검출 방사능 농도 결정)

  • Kim, Jong-Soo;Yoon, Suk-Chul;Shin, Jang-Soo;Kwack, Eun-Ho;Choi, Jong-Seo
    • Journal of Radiation Protection and Research
    • /
    • v.22 no.2
    • /
    • pp.111-117
    • /
    • 1997
  • Recently, the conclusion of Comprehensive Test Ban Treaty(CTBT) is globally constructing a network system for nuclear test monitoring. The radionuclide experts of the Conference on Disarmament recommended that the detection of nuclear debris in the atmosphere was an essential factor of nuclear test monitoring and proposed the technical requirements. Based on those requirements, atmospheric radionuclide monitoring system to detect nuclear debris generated from the nuclear explosion test was composed. The system is comprised of high volume air sampler(HVAS), filter paper presser and high purity germanium detector(HPGe). Minimum detectable concentrations(MDCs) of the key nuclides requiring in CTBT monitoring strategies are determined by considering of decay time, counting time and flow rate of the high volume air sampler for the rapid explosion and the optimum measurement condition. The results were selected $10{\pm}$2h, $20{\pm}$2h and $850{\pm}50m^3$/h as parameters, respectively. The relation between the natural air-borne radionuclide concentration of $^{212}Pb$ and MDC were calculated which gave effect in the Compton continuum baseline due to those nuclides in the gamma-ray spectroscopy. These results can be used as an actually tool in the CTBT monitoring strategies.

  • PDF

Comparision of TTC-II and disk assay method for the detection of antibiotic residues in milk (우유내 잔류물질 검사방법인 TTC-II법 및 Disk assay법의 비교시험)

  • 이정아;이은미;이성해;도재철;박영구
    • Korean Journal of Veterinary Service
    • /
    • v.22 no.1
    • /
    • pp.93-101
    • /
    • 1999
  • This test process on screening method for the detection of residual antibiotics in milk is simple, economic, sensitive to residual antibiotics and was given approval international organs. Thus, this study was carried out the comparison of Disk assay method and TTC-II method for sensitivity and minimum detectable range of antibiotics in raw milk. The results of this study was summarized as follows ; 1. The number of samples requested for treatment of mastitis was 198 samples. Comparison or analytical results among the methods of TTC-II, disk assay and Delve sp was that TTC-II 37 samples(18.6% ), Disk assay 125samples(63.1%), Delve SP 130 samples(65.7% ) reacted positively. Conformity rate of Delve SP and Disk assay was 70%. 2. Detectable limits of disk assay method in some antibiotics were more sensitive than those of official method(0.05-0.0025ppm in the $\beta$-lactams, 1ppm in two aminoglycoside, 0.2 ppm in one tetracycline, similar in one macrolide) 3. For sensitivity of residual sulfonamides TTC-II was much more sensitive than disk assay. Detectable limits of sulfamethazine and sulfadimethoxine were 30 to 50ppm levels. 4. The best medium preservation period is 1-2 days. 5. Concentration of brome cresol purple related to resistance for B stearothermophilus culture was 24ppm/ml. These results show that disk assay method for screening detection of antibiotics residuces in milk is worthy of use.

  • PDF

Significant Parameters for Assessing Soil Contaminant-Leaching to Groundwater and Determining Soil Sample Size in Field Survey

  • Jeong, Seung-Woo;An, Youn-Joo
    • Environmental Engineering Research
    • /
    • v.13 no.2
    • /
    • pp.73-78
    • /
    • 2008
  • For a given soil-contaminated site, a level of soil contamination is characterized and decisions on risk may be made from the risk assessment. The study evaluated critical design factors for the determination of sample size in the sampling design plan and the assessment of soil contaminant- leaching to groundwater. Two variables, the minimum relative detectable difference (T) and coefficient of variation (CV) were evaluated for the sample size determination. The minimum number of samples can be appropriately determined by CV under a T value greater than or equal to 0.2. Soil-contaminant leaching to groundwater was evaluated by using the Soil Screening Level equation of U.S. Environmental Protection Agency and the Risk Based Screening Level equation of American Society for Testing and Materials, with the same input parameters. The groundwater concentrations estimated from soil contaminant concentrations were significantly affected by the Darcy velocity of groundwater and the organic content of soil.

Performance Characteristics of In-Situ Particle Monitors at Sub-Atmospheric Pressure (감압상태에서의 In-Situ Particle Monitor의 성능특성)

  • Bae, Gwi-Nam
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.22 no.11
    • /
    • pp.1564-1570
    • /
    • 1998
  • In-situ particle monitors(ISPMs) are widely used for monitoring contaminant particles in vacuum-based semiconductor manufacturing equipment. In the present research, the performance of a Particle Measuring Systems(PMS) Vaculaz-2 ISPM at subatmospheric pressures has been studied. We created uniform upstream conditions of particle concentration and measured the detection efficiency, the lower detection limit, and the size response of the ISPM using uniform sized methylene blue aerosol particles. The effect of particle size, particle velocity, particle concentration, and system pressure on the detection efficiency was examined. Results show that the detection efficiency of the ISPM decreases with decreasing chamber pressure, and with increasing mass flow rate. The lower detection limit of the ISPM, determined at 50 % of the measured maximum detection efficiency, was found to be about $0.15{\sim}0.2{\mu}m$, which is similar to the minimum detectable size of $0.17{\mu}$ given by the manufacturer.

Bioequivalence Study of Ranitidine Tablet

  • Shim, Chang-Koo;Hong, Jae-Sung;Lee, Chang-Ki;Han, Ik-Soo;Choi, Kwang-Sik
    • Archives of Pharmacal Research
    • /
    • v.13 no.2
    • /
    • pp.180-186
    • /
    • 1990
  • A bioequivalence study of ranitidine tablets was conducted according to the Korean Guidine for the Bioequivalence Test using twelve healthy male subjects. The plasma concentration-timecurves of ranitidine from the test and reference tablets showed profound multiple peak phenomenon in each subject as reported earlier. However, the area under the plasma concentration-time curve (AUC) and the maximum ploasma concentration at the first peak ($C_{max1}$) of the two preparations was proven to be equal when analyzed satistically according to the criteria of the guidline;i. e., statistical power (1-$\beta$)was calculated to be over 0.8 under the condition of $\alpha$ = 5% and $\Delta$(minimum detectable difference) = 20%, and the confidence interval of the difference in AUC at 95% confidence level was in the range of $\pm$ 20%, which statisfied the criteria of bioequivalence. Equivalence of the peak concentration of ranitidine at the second peak ($C_{max2}$), and the time to reach the first ($T_{max1}$) and second verify the bioequivalence of $c_{max2}$ , $T_{max1}$ and $T_{max2}$ between the two tablets. However, we conclude that the test and reference tablets are bioequivalent taking the therapeutic characteristics of the ranitidine preparations into consideration.

  • PDF

Bioequivalence Evaluation of the Tiropramide hydrochloride (염산티로프라미드제제의 생물학적 동등성 평가)

  • 명승운;김동현;김명수;강태경;민혜기;장윤정;손동렬;홍영훈;신창식
    • Biomolecules & Therapeutics
    • /
    • v.8 no.3
    • /
    • pp.262-268
    • /
    • 2000
  • The bioequivalence of two tiropramide products was evaluated in 18 health male volunteers following oral administration. Test product was Tira $m^{R}$ tablet (Shin Poong SP-102) (Shin Poong Pharm. Co., Ltd.) and reference product was Tirop $a^{R}$ tablet (Dae Woong Pharm. Co., Ltd.) One capsule of the test and reference product containing 100 mg of tropramide.hydrochloride was administered to the volunteers by randomized two period cross-over study (2 $\times$ 2 Latin square method). The drug concentration in plasma was determined by GC/MS for over a period of 12hours after administration. Analysis of variance reveal that there are no differences in AUC (area under the plasma concentration-time curve from time zero to infinity), Cmax (maximum plasma concentration) and Tmax (time to reach Cmax). The differences of mean AUC, Cmax and Tmax between two products were 3.85, 1.47 and -3.6%, respectively. Minimum detectable differences (%) at $\alpha$=0.1 were all less than 20% given as a guideline (18.07, 17.00 and 20.69% for AUC, Cmax and Tmax, respectively). From these results, the two products are bioequivalent.ent.

  • PDF

Genotoxicity Assay Using Chromosomally-Integrated Bacterial recA::Lux

  • Min, Ji-Ho;Gu, Man-Bock
    • Journal of Microbiology and Biotechnology
    • /
    • v.13 no.1
    • /
    • pp.99-103
    • /
    • 2003
  • An Escherichia coli strain containing the recA promoter that fused to the luxCDABE operon originating from Photorhabdus luminescens was shown to respond sensitively to genotoxic stresses. Two different recombinant bacteria, one (DPDI 657) harboring a plasmid with the recA promoter that fused to the luxCDABE operon, and the other (DPD1710) containing a chromosomally-integrated recA promoter that fused with luxCDABE, were compared and it was found that the sensitivity of 'the two strains was significantly different in terms of their bioluminescent level, response time, and the minimum detectable concentration of a chemical causing DNA damaging stress. DPDI 710, with a chromosomally-integrated single copy, generally led to lower basal luminescence levels, faster responses, increased response ratios, and an enhanced sensitivity to mutagens, when compared to DPD 1657 with a multi-copy plasmid.

Noise Equivalent Differential Temperature of Passive FTIR Sensor System (수동형 퓨리에변환 적외선 분광기의 잡음등가온도지수)

  • Kang, Young-Il;Park, Byeong-Hwang;Choi, Myung-Jin;Hong, Dea-Sik;Choi, Soo;Kim, Dong-Hwan;Park, Do-Hyun
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.14 no.2
    • /
    • pp.161-166
    • /
    • 2011
  • The passive open-path Fourier-Transform-Infrared system was implemented for the toxic gas monitoring. Noise Equivalent Differential Temperature(NEDT) was investigated as a system performance evaluation figure and analyzed numerically with the designed parameters. Calculated NEDT was compared with the experimental value in the wavelength region of $700{\sim}1400cm^{-1}^$. The minimum detectable gas concentration was estimated from the obtained NEDT at the absorption wavelength of $SF_6$.