고온 강판의 분무냉각에 있어서 MHF 점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 춘계학술대회논문집D
    • /
    • pp.175-180
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about $900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the experimental results show that the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

고온 평판의 분무냉각에 있어서 MHF점에 관한 연구 (Study on Minimum Heat Flux Point in Spray Cooling of Hot Plate)

  • 김영찬
    • 설비공학논문집
    • /
    • 제13권10호
    • /
    • pp.974-981
    • /
    • 2001
  • In this study, the minimum heat flux conditions are experimentally investigated for the spray cooling of hot plate. The hot plates are cooled down from the initial temperature of about$ 900^{\circ}C$, and the local heat flux and surface temperatures are calculated from the measured temperature-time history. The results show that the minimum heat flux point temperatures increase linearly resulting from the propagation of wetting front with the increase of the distance from the stagnation point of spray flow. However, in the wall region, the minimum heat flux point temperature becomes independent of the distance. Also, the velocity of wetting front increases with the increase of the droplet flow rate.

  • PDF

액체용 중량식 유량계 교정장치의 일방향 Diverter 특성연구 (Characteristics of Uni-directional Diverter for Gravimetric Calibration Facility)

  • 남기한;박종호;김홍집
    • 한국유체기계학회 논문집
    • /
    • 제20권1호
    • /
    • pp.59-64
    • /
    • 2017
  • Diverter is an essential element in gravimetric calibration method of flowmeter. Error of diverter are influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. That's why, time detection position of diverter is tuned through repetitive test for minimizing error of diverter. Further the diverter must be compared with the other institutions test since the influence on the accuracy of the flow meter used in the test. In this paper, errors (flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location) of diverter are decreased by produced uni-direction diverter and error of gravimetric calibration system is decreased. Uni-direction diverter is calibrated by gravimetric calibration system with precision flowmeter, the flowmeter is calibrated by pipe prover and other institutions and uni-direction diverter is evaluated. Uni-direction diverter is not influenced by flow velocity profile of nozzle outlet, motion velocity of diverter and detecting location. As a result, Uni-direction diverter can calibrate in wider scope since increasing ratio of maximum and minimum flow rate of uni-direction diverter.

Is There a Difference in Blood Flow Velocity between Bilateral Common Carotid Arterises in Community-Dwelling Elderly with Unilateral Chewing Habit and Forward Head Posture?: An Observational Cross-Sectional Study

  • Bae, Youngsook
    • 국제물리치료학회지
    • /
    • 제11권1호
    • /
    • pp.1954-1959
    • /
    • 2020
  • Background: Due to aging, blood flow rate decreases, also posture and chewing habit may be changed. Objective: To identify that changes in blood velocity in the common carotid arteries (CCAs) in old persons with unilateral chewing habit (UCH) and forward head posture (FHP) in the elderly. Design: An observational cross-sectional study. Methods: Chewing habits, FHP, and CCAs velocities were assessed in 85 elderly subjects. Chewing habits were measured by visual observation. CCAs measured the peak systolic velocity (PSV), end-diastolic velocity (EDV), minimum diastolic velocity, and resistivity index. The subjects were divided into UCH and bilateral chewing habit groups depending on chewing habit. The subjects were also divided into >49 degrees and <49 degrees for comparison of blood flow between the left and right CCAs. Results: In the UCH, the chewing side had significantly higher EDV (P=.003), PSV (P=.023) than the non-chewing side. There was no significant difference in velocity between the CCAs in the FHP. Conclusion: This study shows that the blood flow velocity of the chewing side of UCH was higher, and unilateral chewing affects the CCAs velocity and thus highlight the importance of chewing habit in the elderly than head posture.

유속과 유동교란인자에 의한 전자식 및 초음파식 유량계의 오차특성 연구 (A Study on Error Characteristic of Flow Disturbance and Velocity for Electromagnetic and Ultrasonic Flowmeters)

  • 이동근;박종호
    • 한국유체기계학회 논문집
    • /
    • 제12권5호
    • /
    • pp.33-38
    • /
    • 2009
  • In this study, the effect of flow disturbance such as contraction, expansion pipe and velocity deviation from low velocity of $0.1\;^m/s$ to $2.5\;^m/s$ on the error characteristics of the flowmeter was studied. Flow experiments using flowmeter calibration facility of K-water were undertaken for the cases of ultrasonic flowmeter based on transit-time method and electromagnetic flowmeter. Experimental results are presented that measurement error of expansion pipe are larger than contraction pipe. It is shown that the minimum straight length were required to remain of ${\pm}0.5%$ error for electromagnetic flowmeter and ${\pm}2.0%$ error for ultrasonic flowmeter.

표면 거칠기에 따른 마이크로 채널의 유속에 관한 연구 (A Study on the Flow Velocity of Micro Channels Depending on Surface Roughness)

  • 박현기;김종민;홍민성
    • 한국공작기계학회논문집
    • /
    • 제17권1호
    • /
    • pp.59-64
    • /
    • 2008
  • Micro machining can manufacture complex shapes with high accuracy. Especially, this enables wide application of micro technology in various fields. For example, micro channels allow fluid transfer, which is a widely used technology. Therefore, liquidity research of flow in micro channels and micro channel manufacturing with use of various materials and cutting conditions has very important meaning. In this study, to find out correlation between fluid velocity in micro channels and surface roughness, we manufactured micro channels using micro end-mill and dropped ethanol into micro channels. We compared several surface roughness and fluid velocity in micro channels that were created by various processing conditions. Finally, we found out relationship between fluid velocity and surface roughness in micro channels of different materials.

헵탄 풀화재에서 불활성기체 소화농도 (Extinguishing Concentration of Inert Gases in Heptane Pool Fires)

  • 정태희;이의주
    • 한국안전학회지
    • /
    • 제27권3호
    • /
    • pp.71-76
    • /
    • 2012
  • The coflow velocity effect on the minimum extinguishing concentration(MEC) was investigated experimentally in heptane cup-burner flames. Various inert gases($N_2$, Ar, $CO_2$, He) were added into the oxidizer to find the critical concentration and the effectiveness of the agents on flame extinction. The experimental results showed that the MECs were increased with increasing coflow velocity for most inert gases except helium, but the higher coflow velocity induced the lower burning rates of heptane. This indicated that the increase of coflow velocity resulted in the decrease of fuel velocity evaporated from fuel surface, and hence the stain rate on the reaction zone was also decreased. In the case of helium as a additive, the extinguishing concentration was independent of the coflow velocity because the heat conductivity was ten times larger than the other inert gases and flow effect by a strain rate might be compensated for heat loss to the surroundings.

플라즈마 피치에 따른 150mm 샤워헤드에 대한 CFD 유동해석 (CFD flow analysis of 150mm shower heads depending on plasma pitch)

  • 김동화;김호범;조종두;정대교
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회A
    • /
    • pp.585-589
    • /
    • 2008
  • This study is performed to analyze the fluid flow about 150mm shower heads of semiconductor device. Under the air pressure, the ideal gas of moving fluid is injected as 5m/s velocity into inlet of shower heads and the flow distribution in shower heads is measured according to pitch of plasma distribution device. As results, the maximum and minimum value of fluid velocity are investigated with their position. The velocity values at outlet are also studied. From two experiment using the plasma distribution device, the results of CFD are compared with the experimental results. That results shows stable flow of fluid in that case of corrected design from CFD.

  • PDF

클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 유동해석에 관한 연구 (A Study on Fluid Flow Analysis of High Pressure Positive Displacement Pump without Clearance)

  • 민세홍;김호철
    • 한국화재소방학회논문지
    • /
    • 제29권2호
    • /
    • pp.33-38
    • /
    • 2015
  • 고압과 정량 흡상을 목적으로 클리어런스가 없는 초고압 회전용적형 헬리컬기어 펌프의 개발을 진행하였다. 펌프의 내부 압력과 토출 유속을 검증하기 위해 CFD 해석을 수행하였다. 이에 따라 FVM 기법으로 유동해석을 수행하였는데 클리어런스가 없는 완전히 밀폐된 형태의 FVM 유동해석은 격자가 연속하게 구성되지 않아 유체영역이 분리되어 정상적인 결과를 얻어낼 수 없었다. 이러한 문제로 격자 구성이 필요치 않은 MPS 기법으로 유동해석을 수행하였고, MPS 유동해석을 통해 펌프의 내부 압력과 토출 유속을 확인할 수 있었다. 로터의 회전속도 1,000 rpm에서 펌프 내부의 압력은 최소일 때 19.5 bar, 최대일 때 44.6 bar이고, 평균 압력은 33.9 bar로 확인되었다. 토출 유속은 최소일 때 64.5 m/s, 최대일 때 84.8 m/s이고, 평균 유속은 76.1 m/s로 확인되었다. 본 연구를 통해 클리어런스가 없는 해석 모델의 유동해석은 FVM 기법보다는 MPS 기법이 더 적합하였음을 확인할 수 있었다. 또한 초고압 회전 용적형 헬리컬기어 펌프의 압력의 변화에 따른 유속과의 관계를 본 연구를 통해 규명할 수 있었다.