Adaptive DC-link Voltage Control for Shunt Active Power Filter

  • Wang, Yu;Xie, Yun-Xiang
    • Journal of Power Electronics
    • /
    • 제14권4호
    • /
    • pp.764-777
    • /
    • 2014
  • This study analyzes the mathematical relationship between DC-link voltage and system parameters for shunt active power filters (APFs). Analysis and mathematical deduction are used to determine the required minimum DC-link voltage for APF. A novel adaptive DC-link voltage controller for the three-phase four-wire shunt APF is then proposed. In this controller, the DC-link voltage reference value will be maintained at the required minimum voltage level. Therefore, power consumption and switching loss will effectively decrease. The DC-link voltage can also adaptively yield different DC-link voltage levels based on different harmonic currents and grid voltage levels and thus avoid the effects of harmonic current and grid voltage fluctuation on compensation performance. Finally, representative simulation and experimental results in a three-phase four-wire center-split shunt APF are presented to verify the validity and effectiveness of the minimum DC-link voltage design and the proposed adaptive DC-link voltage controller.

최소 손실 불연속 변조 기법에 따른 2레벨 3상 전압원 인버터의 직류단 전압 맥동 분석 (DC-Link Voltage Ripple Analysis of Minimum Loss Discontinuous PWM Strategy in Two-Level Three-Phase Voltage Source Inverters)

  • 이준혁;박정욱
    • 전력전자학회논문지
    • /
    • 제26권2호
    • /
    • pp.120-126
    • /
    • 2021
  • DC-link capacitors are one of the main components in two-level three-phase voltage source inverters (VSIs); they provide the pulsating input current and stabilize the vacillating DC-link voltage. Ideally, the larger the capacitance of DC-link capacitors, the better the DC-link voltage stabilizes. However, high capacitance increases the cost and decreases the power density of VSI systems. Therefore, the capacitance should be chosen carefully on the basis of the DC-link voltage ripple requirement. However, the DC-link voltage ripple is dependent on the pulse-width modulation (PWM) strategy. This study especially presents a DC-link voltage ripple analysis when the minimum loss discontinuous PWM strategy is applied. Furthermore, an equation for the selection of the minimum capacitance of DC-link capacitors is proposed. Experimental results with R-L loads are also provided to verify the effectiveness of the presented analysis.

DC-링크 전압균형과 소자의 최소 온/오프 시간을 고려한 3-레벨 인버터의 PWM 기법 및 구현 (A New PWM Method and its Implementation for a 3-Level Inverter Considering DC-Link Voltage Balancing and Minimum ON/Off Time)

  • 이요한;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1998년도 전력전자학술대회 논문집
    • /
    • pp.35-38
    • /
    • 1998
  • In this paper, we present a new SVPWM strategy for a 3-level inverter. This SVPWM method is easily implemented without switching table like SVPWM. In addition, with proposed method, we can also keep the voltage balancing of DC-link capacitors and guarantee minimum on/off time of the devices. The principle of the proposed SVPWM method is described in detail, and its implementation method is also proposed. The usefulness of the proposed SVPWM method is verified through the simulation using MATLAB/Simulink.

  • PDF

유도 전동기 구동 시스템을 위한 PWM전압원 인버터 DC-링크 필터 설계 (Minimum DC-Link Filter in Three-phase PWM Voltage Source Inverter for Induction Motor Drive)

  • 김광섭;서범석;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.495-497
    • /
    • 1994
  • Given the constraint of the AC input power factor and the DC-link voltage and current ripple in voltage source inverter, minimizing the size and cost of the DC-link fitter components is very important. This paper presents a procedure for the selection of DC-link filler element values in a three-phase PWM voltage source inverter-fed induction motor drive system, which can not only satisfy the requirements for the system performance but also minimize the filter size.

  • PDF

DC-링크 전압균형과 최소 온-오프 시간을 고려한 새로운 3-레벨 GTO 인버터 제어기법 (A New Switching Method for 3-level GTO Inverter Considering DC-link Voltage Balancing and Minimum on/off time)

  • 이요한;현동석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.373-375
    • /
    • 1994
  • In realizing a three-level GTO inverter, we should keep the voltage balancing of DC-link capacitors and consider minimum on/off time of GTO thyristors in order to make the same blocking voltage across each device and to minimize the harmonic components of the output voltage and current. In this raper, a new PWM scheme based on space voltage vectors, by which it is possible to keep neutral-point voltage and avoid narrow pulse, is presented. Experimental results verify that the proposed PWM control scheme is suitable fur hish power and high voltage three-level GTO inverters applied to induction motor drives.

  • PDF

DC링크 전류센서를 이용한 삼상전류 측정 방식에서 최소 스위칭 시간의 단축 (Reduction of Minimum Switching Duration in the Measurement of Three Phase Current with DC-Link Current Sensor)

  • 김경서
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제52권12호
    • /
    • pp.649-654
    • /
    • 2003
  • The simplest method for measuring output currents of the three phase inverters is to measure them with three current sensors such as hall sensors. This method requires at least two current sensors, and these types of sensors are somewhat expensive. More economical method is measuring DC link current with a simple shunt resistor, then, reconstructing output current using the DC link current value and the switching status. However, in low speed region, the measurement becomes difficult and even impossible due to the requirement of minimum switching duration for A/D conversion. These problems can be overcome by limitation of switching duration. Limitation of switching, however, causes voltage and current distortion. Owing to compensation, distortion can be effectively suppressed. However these increase acoustic noise due to increment of current ripple. In this paper, a current measurement method is proposed, which can reduce minimum switching duration resulting in reduction of acoustic noise. The validity of proposed method is confirmed through experiment.

3상 인버터 시스템에서 주파수 특성을 고려한 필름 콘덴서의 DC-link 적용 방법에 관한 연구 (The study on DC-link Film Capacitor in 3 Phase Inverter System for the Consideration of Frequency Response)

  • 박현수
    • 한국산학기술학회논문지
    • /
    • 제19권4호
    • /
    • pp.117-122
    • /
    • 2018
  • 대용량 3상 시스템 에어컨은 최근 들어 소비 전력 저감을 위해 인버터 회로를 포함하고 있다. 인버터 회로는 교류를 다이오드를 통해 정류하고 DC-link 전원부 콘덴서에 의해 평활된 직류를 사용한다. 이 때 평활에 사용되는 DC-link 전원부 콘덴서는 전압 리플, 전류 리플 조건을 만족하기 위해 전해 콘덴서가 일반적으로 사용된다. 콘덴서의 용량을 줄이게 되면 회로부의 크기 및 무게, 비용을 줄일 수 있게 된다. 본 논문에서는 최소점 추정 PPL(Phase Locked Loop) 위상 제어와 평균 전압 d축 전류제어 기법을 조합하여 입력 리플 전류를 약 90% 저감하는 알고리즘을 제안한다. 입력 리플 전류의 감소로 인해 DC-link 콘덴서의 전류 리플도 감소하므로 콘덴서의 용량을 줄일 수 있지만 전해 콘덴서의 경우 등가 직렬 저항(ESR : Equivalent Series Resistance)이 크기 때문에 발열로 인한 수명이 한계를 가진다. 본 논문에서는 전해 콘덴서 대신 DC-link 단에 전류 리플을 고려한 필름 콘덴서를 선정하는 방법을 제안한다. 필름 콘데서의 정전 용량 선정, 내압 선정, RMS(Root Mean Square) 전류 용량, RMS 전류 주파수 해석을 고려해 콘덴서의 용량을 선정할 경우 1680uF의 전해 콘덴서를 20uF로 용량을 낮추어 설계함으로써 전원부 콘덴서의 크기 및 무게, 비용을 줄였으며 전동기 구동을 통해 동작을 확인하였다.

DVR(Dynamic Voltage Restorer)에서의 직류에너지 제어 방법 (The DC Link Energy Control Method of Dynamic Voltage Restorer System)

  • 정일엽;박상영;원동준;문승일;박종근;한병문
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제50권12호
    • /
    • pp.575-583
    • /
    • 2001
  • Dynamic Voltage Restorer(DVR) which is installed between the supply and a critical load can restore voltage disturbances in distribution system. The restoration is based on injecting the same voltages as voltage sags. The ideal restoration is compensation to make the load voltages be unchanged. But voltage restoration involves real power or energy injection and the capability of energy storage is limited. So it must be considered how injection energy can be minimized and voltages can be made close to the voltages before fault. This paper describes conventional restoration techniques, which draw minimum energy from the DVR in order to correct a given voltage sag or swell. And this paper proposes a new concept of restoration technique to inject minimum energy. The proposed method is based on the definition of voltage tolerance in load side. Hence using the proposed method a particular disturbance can be corrected with less amount of storage energy compared to those of conventional methods.

  • PDF

예측제어를 이용한 T-형 3-레벨 인버터의 중성점 전압제어 (The DC-link Voltage Balancing of the Three-Level T-type Inverter Using the Predictive Control)

  • 김태훈;이우철
    • 전기학회논문지
    • /
    • 제65권2호
    • /
    • pp.311-318
    • /
    • 2016
  • This paper is a study on the neutral point voltage balancing of the three-phase 3-level T-type inverter using the predictive control techniques. Recently, multi-level inverter has been attracting attention as the advantages such as efficiency improving and harmonic reduction. Especially, the T-type inverter topology is advantageous in low DC-link voltage. However, in case of the prediction control, it takes a lot of time, because there exist 27 voltage vectors and it has to be calculated according to the respective voltage vectors. Therefore, in this paper, we propose a method to implement predictive control techniques while reducing the operation time. In order to reduce the operation time, the predictive control is implemented by using the minimum voltage vector except for the unnecessary voltage vector. The result of the implemented predictive control is added to the SPWM by using the offset voltage. It was verified through simulation and experimental results.

Variable-magnitude Voltage Signal Injection for Current Reconstruction in an IPMSM Sensorless Drive with a Single Sensor

  • Im, Jun-Hyuk;Kim, Sang-Il;Kim, Rae-Young
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권4호
    • /
    • pp.1558-1565
    • /
    • 2018
  • Three-phase current is reconstructed from the dc-link current in an AC machine drive with a single current sensor. Switching pattern modification methods, in which the magnitude of the effective voltage vector is secured over its minimum, are investigated to accurately reconstruct the three-phase current. However, the existing methods that modify the switching pattern cause voltage and current distortions that degrade sensorless performance. This paper proposes a variable-magnitude voltage signal injection method based on a high frequency voltage signal injection. The proposed method generates a voltage reference vector that ensures the minimum magnitude of the effective voltage vector by varying the magnitude of the injection signal. This method can realize high quality current reconstruction without switching pattern modification. The proposed method is verified by experiments in a 600W Interior permanent magnet synchronous machine (IPMSM) drive system.